Potraži kabel

Select a cable or enter another designation.


UNIMA CABLE | DATA & COMMUNICATION CABLES

J-2Y(St)Y St III Bd – Screened ISDN & Telecommunication Cable

Screened indoor telecommunication and ISDN installation cable with solid bare copper conductors, polyethylene insulation, star-quad stranding, foil screening, drain wire and grey PVC outer sheath. Designed for analogue and digital signal transmission at data rates up to 16 Mbit/s.

100 Ohm Up to 16 Mbit/s 2–100 Pairs 0.6 mm Conductor Diameter Class 1 Solid Copper PE Insulation Foil Screen Drain Wire Star-Quad Stranding PVC Outer Sheath RAL 7032 IEC 60332-1-2 300 V Peak Operating Voltage

Product Overview

J-2Y(St)Y St III Bd is a screened telecommunication and ISDN installation cable designed for connecting computer units, ISDN sub-units, communication devices and data transmission equipment.

The cable incorporates solid bare copper conductors with a nominal conductor diameter of 0.6 mm and polyethylene core insulation.

Four insulated conductors are twisted together to form a star-quad. Five star-quads form one sub-unit, with sub-units arranged in layers according to the cable configuration.

The cable construction includes foil screening and a drain wire. The outer sheath is manufactured from grey PVC, colour RAL 7032.

The specified characteristic impedance is 100 Ohm, with a maximum operating capacitance of 52 nF/km and a maximum peak operating voltage of 300 V.

J-2Y(St)Y St III Bd is intended for installation in dry and wet rooms, on and under plaster, and supports analogue and digital signal transmission at data rates up to 16 Mbit/s.

The reference range comprises 10 configurations from 2 to 100 pairs.

Key Technical Features

100 ΩCharacteristic Impedance
16 Mbit/sMaximum Specified Data Rate
2–100Number of Pairs
0.6 mmConductor Diameter
52 nF/kmMaximum Operating Capacitance
300 VPeak Operating Voltage
5,000Insulation Resistance MΩ·km
10Reference Configurations

Cable Construction & Technical Properties

Cable Construction

Materijal vodičaBare Copper
Conductor ConstructionClass 1, Solid
Nominal Conductor Diameter0.6 mm
Number of Pairs2–100
Core InsulationPolyethylene (PE)
Stranding UnitFour-Core Star-Quad
Sub-Unit ConstructionFive Star-Quads
Overall StrandingBundled Sub-Units in Layers
ScreeningFoil Screen
Drain WireYes
Outer Sheath MaterialPVC
Outer Sheath ColourGrey, RAL 7032

Electrical & Mechanical Properties

Characteristic Impedance100 Ohm
Maximum Operating Capacitance52 nF/km
Peak Operating Voltage300 V
Maximum Data Rate16 Mbit/s
Insulation Resistance5,000 MΩ·km
Coupling K1400 pF
Coupling K9–12100 pF
Fixed Temperature Range-30°C to +70°C
Temperature During Movement-5°C to +50°C
Minimum Fixed Bending Radius7.5 × Outer Diameter
Flame RetardancyIEC 60332-1-2
Approximate Outer Diameter5.5–25.0 mm
Copper Weight (GER)13–568 kg/km
Approximate Cable Weight42–861 kg/km

Star-Quad Stranding Technology

Four-Core Star-Quad Construction

Four individually insulated solid copper conductors are twisted together into a star-quad configuration.

Each star-quad comprises four conductors corresponding to two communication pairs.

The symmetrical arrangement is intended to support the electrical transmission and coupling characteristics required for telecommunication applications.

Bundled Sub-Unit Construction

Five star-quads are stranded together to form one sub-unit in the specified bundle construction.

Each complete sub-unit therefore contains 20 individual conductors, corresponding to 10 pairs.

Sub-units are arranged in layers for larger cable configurations.

Smaller configurations contain fewer star-quads.

Core Identification System

The star-quads within each complete bunch are identified by the following continuous colours:

Red Green Grey Yellow White

The four individual conductors within each star-quad are distinguished by ring markings.

Individual Conductor Identification

a-wire 1Without Ring
b-wire 1One Ring, Wide Spacing
a-wire 2Double Ring, Wide Spacing
b-wire 2Double Ring, Narrow Spacing

Screening & Signal Transmission

Foil Screen and Drain Wire

The reference cable construction incorporates a foil screen and a drain wire.

The screening arrangement is intended to reduce the influence of external electromagnetic interference on transmitted signals.

The drain wire facilitates electrical connection of the screening system during termination.

Screen material and drain wire dimensions must be confirmed in the final manufacturer specification.

100 Ohm Transmission Characteristics

The specified characteristic impedance is 100 Ohm.

The cable supports analogue and digital signal transmission at data rates up to 16 Mbit/s according to the reference documentation.

Maximum operating capacitance is specified as 52 nF/km.

Transmission distance, attenuation and system compatibility must be assessed according to the connected equipment and installation conditions.

PE Insulation & PVC Outer Sheath

Polyethylene Core Insulation

The solid copper conductors are individually insulated with polyethylene.

The specified insulation resistance is 5,000 MΩ·km.

The dielectric construction supports the documented capacitance and impedance characteristics of the communication cable.

Grey PVC Outer Sheath

The outer sheath is manufactured from polyvinyl chloride in grey RAL 7032.

The reference cable is suitable for installation in dry and wet rooms, on and under plaster.

Flame-retardant performance is specified according to VDE 0482-332-1-2 and IEC 60332-1-2.

Typical Applications

ISDN Communication Systems
ISDN Sub-Unit Connections
Telecommunication Devices
Computer Unit Connections
Analogue Signal Transmission
Digital Signal Transmission up to 16 Mbit/s
Indoor Telecommunication Infrastructure
Commercial Building Communication Systems
Legacy Communication Equipment
Indoor Installation On and Under Plaster

Installation Conditions

Specified Installation Parameters

Dry RoomsSuitable
Wet RoomsSuitable
Installation on PlasterSuitable
Installation under PlasterSuitable
Fixed Temperature Range-30°C to +70°C
Temperature During Movement-5°C to +50°C
Minimum Fixed Bending Radius7.5 × D

Additional Installation Considerations

Outdoor InstallationNot Specified
Direct BurialNot Specified
Permanent Water ImmersionNot Specified
UV ResistanceNot Specified
Continuous Dynamic FlexingNot Specified
Maximum Installation Tensile LoadNot Specified
Ethernet Category RatingNot Declared

Fire & Environmental Performance

Specified Properties

Single-Cable Flame RetardancyIEC 60332-1-2
German Flame Test ReferenceVDE 0482-332-1-2
Outer SheathPVC
Indoor Wet Room InstallationSpecified

Additional Fire Performance Requirements

CPR ClassificationNot Specified
Halogen-Free ConstructionNo – PVC Sheath
Low-Smoke PerformanceNot Declared
Fire-Resistant Circuit IntegrityNot Declared
Bunched Cable Flame RetardancyNot Declared

Applicable Standards

VDE 0482-332-1-2 – German reference for the vertical flame propagation test on a single insulated wire or cable.

IEC 60332-1-2 – Vertical flame propagation test for a single insulated wire or cable.

The reference datasheet identifies the conductor construction as Class 1 solid copper. A separate conductor or product design standard is not explicitly stated.

Data Transmission Note: J-2Y(St)Y St III Bd is a dedicated ISDN and telecommunication cable. Its 100 Ohm impedance does not constitute a declaration of Cat.5e, Cat.6, Cat.6A or other Ethernet category compliance.
Voltage Note: The specified 300 V value refers to peak operating voltage. It is not a declared power cable voltage rating U0/U.
Technical Note: Technical characteristics are based on the reference J-2Y(St)Y St III Bd datasheet. Final construction, electrical characteristics, conformity documentation and availability must be confirmed during quotation.

Technical Documentation

Technical Data Sheet

EU declaration of conformity

Core Identification

Send Us email - RFQ


KOLEKCIJA KABELA UNIMA

Istražite našu ponudu kabela

Otkrijte vrste kabela, tehničke specifikacije i rješenja za svoje projekte.

96 Cable Types Available