J-2Y(St)Y St III Bd – Screened ISDN & Telecommunication Cable
Screened indoor telecommunication and ISDN installation cable with solid bare copper conductors, polyethylene insulation, star-quad stranding, foil screening, drain wire and grey PVC outer sheath. Designed for analogue and digital signal transmission at data rates up to 16 Mbit/s.
Product Overview
J-2Y(St)Y St III Bd is a screened telecommunication and ISDN installation cable designed for connecting computer units, ISDN sub-units, communication devices and data transmission equipment.
The cable incorporates solid bare copper conductors with a nominal conductor diameter of 0.6 mm and polyethylene core insulation.
Four insulated conductors are twisted together to form a star-quad. Five star-quads form one sub-unit, with sub-units arranged in layers according to the cable configuration.
The cable construction includes foil screening and a drain wire. The outer sheath is manufactured from grey PVC, colour RAL 7032.
The specified characteristic impedance is 100 Ohm, with a maximum operating capacitance of 52 nF/km and a maximum peak operating voltage of 300 V.
J-2Y(St)Y St III Bd is intended for installation in dry and wet rooms, on and under plaster, and supports analogue and digital signal transmission at data rates up to 16 Mbit/s.
The reference range comprises 10 configurations from 2 to 100 pairs.
Key Technical Features
Cable Construction & Technical Properties
Cable Construction
Electrical & Mechanical Properties
Star-Quad Stranding Technology
Four-Core Star-Quad Construction
Four individually insulated solid copper conductors are twisted together into a star-quad configuration.
Each star-quad comprises four conductors corresponding to two communication pairs.
The symmetrical arrangement is intended to support the electrical transmission and coupling characteristics required for telecommunication applications.
Bundled Sub-Unit Construction
Five star-quads are stranded together to form one sub-unit in the specified bundle construction.
Each complete sub-unit therefore contains 20 individual conductors, corresponding to 10 pairs.
Sub-units are arranged in layers for larger cable configurations.
Smaller configurations contain fewer star-quads.
Core Identification System
The star-quads within each complete bunch are identified by the following continuous colours:
The four individual conductors within each star-quad are distinguished by ring markings.
Individual Conductor Identification
Screening & Signal Transmission
Foil Screen and Drain Wire
The reference cable construction incorporates a foil screen and a drain wire.
The screening arrangement is intended to reduce the influence of external electromagnetic interference on transmitted signals.
The drain wire facilitates electrical connection of the screening system during termination.
Screen material and drain wire dimensions must be confirmed in the final manufacturer specification.
100 Ohm Transmission Characteristics
The specified characteristic impedance is 100 Ohm.
The cable supports analogue and digital signal transmission at data rates up to 16 Mbit/s according to the reference documentation.
Maximum operating capacitance is specified as 52 nF/km.
Transmission distance, attenuation and system compatibility must be assessed according to the connected equipment and installation conditions.
PE Insulation & PVC Outer Sheath
Polyethylene Core Insulation
The solid copper conductors are individually insulated with polyethylene.
The specified insulation resistance is 5,000 MΩ·km.
The dielectric construction supports the documented capacitance and impedance characteristics of the communication cable.
Grey PVC Outer Sheath
The outer sheath is manufactured from polyvinyl chloride in grey RAL 7032.
The reference cable is suitable for installation in dry and wet rooms, on and under plaster.
Flame-retardant performance is specified according to VDE 0482-332-1-2 and IEC 60332-1-2.
Typical Applications
Installation Conditions
Specified Installation Parameters
Additional Installation Considerations
Fire & Environmental Performance
Specified Properties
Additional Fire Performance Requirements
Applicable Standards
VDE 0482-332-1-2 – German reference for the vertical flame propagation test on a single insulated wire or cable.
IEC 60332-1-2 – Vertical flame propagation test for a single insulated wire or cable.
The reference datasheet identifies the conductor construction as Class 1 solid copper. A separate conductor or product design standard is not explicitly stated.