N2XY-J / N2XY-O – Copper XLPE Power Cable 0.6/1 kV


Technical Specifications

  • N2XY-J / N2XY-O
  • Cable Type
  • Power Distribution, Buildings & Industrial Installations
  • Application
  • VDE 0276-603
  • Standard

Details

  • Insulation Material XLPE
  • Packaging Coils / Wooden Drums – On Request
  • Availability Stock
  • Cable Function Low Voltage Power Distribution
  • Conductor Material Bare Copper
  • Conductor Construction Class 2, RE / RM / SM Variants
  • Conductor Material Bare Copper, Class 2 Stranded
  • Cable Group EV Charging Cables, Power cables 1 - 30 kV
  • Insulation Material XLPE
  • Rated Voltage 0.6/1 kV
  • CPR Class Eca
  • Standard VDE 0276-603
UNIMA CABLE | LOW VOLTAGE POWER SOLUTIONS

N2XY-J / N2XY-O – Copper XLPE Power Cable

Copper power cable with cross-linked polyethylene insulation and a PVC outer sheath. Designed for fixed installation in buildings, industrial facilities, underground routes and outdoor power distribution networks.

0.6/1 kV XLPE Insulation Class 2 Copper CPR Eca UV Resistant VDE 0276-603

Product Overview

N2XY is a low-voltage power cable with bare copper conductors, XLPE insulation and a PVC outer sheath. It is suitable for fixed installation indoors, outdoors, in the ground and in water.

The cable is available in N2XY-J versions with a protective conductor and N2XY-O versions without a protective conductor.

XLPE insulation supports a maximum conductor operating temperature of 90°C and a short-circuit conductor temperature of up to 250°C. The cable is flame-retardant according to IEC 60332-1-2 and UV-resistant.

Key Technical Features

0.6/1 kV Rated Voltage
90°C Maximum Conductor Temperature
Eca CPR Classification
4 kV Test Voltage

Construction & Technical Properties

Cable Construction

ConductorBare Copper
Conductor ClassClass 2 Stranded
Core InsulationXLPE
Outer SheathPVC
Core IdentificationVDE 0293 / HD 308
N2XY-JWith Protective Conductor
N2XY-OWithout Protective Conductor

Electrical & Mechanical Data

Rated Voltage0.6/1 kV
Maximum System Voltage1.2 kV
Test Voltage4 kV
Conductor TemperatureMax. 90°C
Short Circuit TemperatureMax. 250°C
Outer Cable, FixedMax. +50°C
Outer Cable, Moved-5°C to +50°C
Bending Radius, Multicore12 × Ø
Bending Radius, Single-Core15 × Ø
UV ResistanceYes

Typical Applications

Low Voltage Power Distribution
Industrial Facilities
Commercial Buildings
Underground Power Cable Routes
Outdoor Electrical Installations
Fixed Installation in Water
Electrical Infrastructure
Building Power Supply Systems

Applicable Standards

VDE 0276-603 – Cable construction and technical requirements.
EN 50575 – CPR classification Eca.
IEC 60332-1-2 – Flame retardance.
VDE 0293 / HD 308 – Core identification.
Technical Notice: Current-carrying capacities depend on the installation method and ambient conditions. Cable diameters and weights are approximate. Product availability and packaging are subject to confirmation.

Technical Data & Cable Dimensions

N2XY-J / N2XY-O | 0.6/1 kV | VDE 0276-603

37Configurations
0.6/1 kVRated Voltage
90°CMax. Conductor Temp.
EcaCPR Classification
Type Size Conductor Resistance
Ω/km
Air
A
Ground
A
Outer Ø
mm
Copper
kg/km
Cable
kg/km
| Source: Klaus Faber AG, N2XY VDE
Technical notes: Air ampacity at 30°C ambient temperature. Ground ampacity at 20°C ground temperature. A dash indicates that the manufacturer has not supplied an ampacity value.

RE = round solid conductor; RM = round stranded conductor; SM = sector-shaped stranded conductor. The suffix "v" is retained from the manufacturer's conductor designation.

All diameters and weights are approximate. Current ratings must be corrected for actual installation conditions. The separate UNIMA weight calculator is not included in this HTML block.

Technical Documentation

Technical Data Sheet

EU declaration of conformity

Core Identification

Maximum 2 cross-sections per Data Sheet. 1 selected
UNIMA CABLE

N2XY-J / N2XY-O Cable Calculator

Copper XLPE Power Cable 0.6/1 kV

Calculate cable weight, copper content and approximate cable length.

m
Cable Weight 0 kg
Cable Length 0 m
Copper Content 0 kg
Copper Share 0 %
Cable weight: 0 kg/km
Copper: 0 kg/km
Approximate values based on technical cable data. Actual values may vary due to manufacturing tolerances.