Find Your Cable

Select a cable or enter another designation.


UNIMA CABLE | LOW VOLTAGE POWER CABLES

E-YCY 0.6/1 kV

PVC insulated and PVC sheathed power cable with bare copper conductors and a concentric copper conductor consisting of copper wires and a counter helix. Designed for fixed installation indoors, outdoors, underground, in water and in concrete. Available in E-YCY-O, E-YCY-OZ and E-YCY-J configurations.

E-YCY 0.6/1 kV Copper Conductor Concentric Copper PVC / PVC Black Sheath CPR Eca* HD 603 Reference
0.6/1 kV Rated Voltage
4 kV Test Voltage
70°C Maximum Conductor Temperature
12 × D Minimum Fixed Bending Radius
-30°C / +70°C Fixed Cable Temperature Range
Eca* CPR Classification

Construction

  • Conductor: Bare copper
  • Conductor class: Class 1; Class 2 from 25 mm²
  • Insulation: PVC DIV 4
  • Concentric conductor: Copper wires with counter helix
  • Outer sheath: PVC
  • Sheath colour: Black
  • Core identification: Colour-coded or numbered, depending on configuration
  • Meter marking: Yes

Applications

  • Fixed indoor electrical installations
  • Outdoor power cable installations
  • Direct burial in the ground
  • Installation in water
  • Installation in concrete
  • Power distribution with a concentric copper conductor

Technical Characteristics

Cable Designation E-YCY
Reference Standard ÖVE/ÖNORM E 8200-603 (HD 603), with reference to
Rated Voltage U₀/U 0.6/1 kV
Maximum System Voltage 1.2 kV
Test Voltage 4 kV
Conductor Construction Class 1 / Class 2 from 25 mm²
Conductor Temperature Max. +70°C
Short-Circuit Temperature Max. +160°C
Fixed Cable Temperature -30°C to +70°C
Moved Cable Temperature -5°C to +70°C
Fixed Bending Radius 12 × D
Moving Bending Radius 15 × D
Maximum Tensile Stress 50 N/mm²
Flame Retardance IEC 60332-1-2
UV Resistance Yes
Outer Sheath Colour Black

Available Configurations

Variant Core Identification Listed Sizes
E-YCY-O Without protective conductor 9
E-YCY-OZ Numbered cores, without protective conductor 15
E-YCY-J With green-yellow protective conductor 3
Technical Note: Technical values and listed configurations are based on the supplied E-YCY reference datasheet. Dimensions and weights are approximate. The Eca classification shown in the reference document must be confirmed for the actual supplied product by its applicable manufacturer Declaration of Performance (DoP). Availability and manufacturer-specific data are subject to confirmation.
UNIMA CABLE | CABLE DIMENSIONS

E-YCY – Technical Size Table

27 listed cable configurations. Click any table row to calculate the total cable and copper weight.

Technical Size Table

Cable Size Outer Diameter (mm) Copper Weight (kg/km) Cable Weight (kg/km)

Cable Weight Calculator

Selected Cable: –
– Total Cable Weight (kg)
– Copper Weight (kg)
– Selected Length (m)
Technical Note: Cable diameters and weights are approximate reference values. Copper weight includes the copper components of the cable. Actual values may vary by manufacturer. Select a cable size by clicking its row.

Technical Documentation

Technical Data Sheet

EU declaration of conformity

Core Identification

UNIMA CABLE

E-YCY 0.6/1 kV Cable Calculator

Calculate cable weight, copper content and approximate cable length.

m
Cable Weight 0 kg
Cable Length 0 m
Copper Content 0 kg
Copper Share 0 %
Cable weight: 0 kg/km
Copper: 0 kg/km
Approximate values based on technical cable data. Actual values may vary due to manufacturing tolerances.

Send Us email - RFQ


UNIMA CABLE COLLECTION

Explore Our Cable Range

Discover cable types, technical specifications and solutions for your projects.

80 Cable Types Available