N2XRH FE 180 Fire Resistant Armoured Cable

Unima Cable


Technical Specifications

  • N2XRH FE 180
  • Cable Type
  • Fire-resistant power distribution, industrial & infrastructure
  • Application
  • TS IEC 60502-1 / VDE 0276
  • Standard

Details

  • Insulation Material XLPE
  • Packaging Wooden Drums
  • Availability Stock
  • Fire Resistance FE 180
  • Armour Galvanized Steel Wire (SWA)
  • Fire Barrier Mica Tape
  • Outer Sheath LSZH
  • Halogen Free Yes
  • Low Smoke Yes
  • Conductor Material Copper
  • Cable Group Armoured Cables, Fire Performance Cables, Power cables 1 - 30 kV
  • Insulation Material XLPE
  • Rated Voltage 0.6/1 kV
  • CPR Class Eca
  • Standard TS IEC 60502-1 / VDE 0276

N2XRH FE 180 is a fire-resistant, armoured 0.6/1 kV power cable designed for fixed installations where circuit integrity, low smoke and halogen-free performance, and mechanical protection are required.

The cable combines a copper conductor, mica fire barrier, XLPE insulation, halogen-free filling, metallic wire armour and a halogen-free outer sheath. It is designed for power distribution in buildings and infrastructure where fire safety is particularly important.

0.6/1 kV
Rated Voltage
FE 180
Fire Resistant
Copper
Conductor
SWA / AWA
Wire Armour
HFFR
Halogen Free

N2XRH FE 180 Cable Construction

Conductor Solid / Stranded Copper Class 1 or Class 2
Fire Barrier Mica Tape Circuit integrity layer
Insulation XLPE Cross-linked polyethylene
Filler Halogen Free HFFR filling material
Armour SWA / AWA Steel wire / aluminium wire*
Outer Sheath Halogen Free HFFR outer sheath
* Round steel wire armour is used for multicore cables. Aluminium wire armour is used for single-core versions.

Technical Data

Rated Voltage U₀/U 0.6/1 kV
Conductor Copper – Class 1 solid / Class 2 stranded
Fire Barrier Mica Tape
Insulation XLPE – Cross-linked Polyethylene
Filler Halogen Free Filler
Armour – Multicore Round Steel Wire (SWA)
Armour – Single Core Aluminium Wire (AWA)
Outer Sheath Halogen Free Sheath
Maximum Operating Temperature 90°C
Maximum Short-Circuit Temperature 250°C – max. 5 seconds
Minimum Bending Radius 15 × D
Test Voltage 3.5 kV
Main Standard TS HD 604 S1 Part 5G / VDE 0276
Conductor Standard IEC 60228

Fire Performance

Circuit Integrity IEC 60331-21
Flame Retardant EN 60332-3 Category C
Flame Retardant EN 60332-1-2
Smoke Density EN 61034
Halogen Free EN 50267

Applications

Power Plants Fire-resistant power distribution in critical energy installations.
Industrial Facilities Suitable for refineries, mines and demanding industrial installations.
Hospitals Power installations where fire safety and circuit integrity are important.
Tunnels Halogen-free armoured cable for demanding infrastructure installations.
Data Centers Suitable for critical power distribution and data processing facilities.
Commercial Buildings Hotels, schools, high-rise buildings and business centres.
Wide Range of Configurations Available in single-core and multicore configurations, including standard power cable sizes, reduced-neutral configurations and multicore versions for control and auxiliary power applications.
Cable dimensions, net weights, conductor resistance, current carrying capacity and standard delivery lengths depend on the selected conductor configuration and cross-section. See the detailed technical table below for individual cable sizes.
N2XRH FE 180 · 0.6/1 kV

Dimensions & Technical Data

Standard cable configurations with nominal dimensions, weights, conductor resistance and current carrying capacity.

01

Single Core

N2XR(a)H FE 180 · Aluminium wire armour

Cross Section
mm²
Overall Ø
mm
Net Weight
kg/km
Delivery
m
Resistance 20°C
Ω/km
In Ground 20°C
A
In Air 30°C
A
1×1.510.5176.6100012.13327
1×2.510.9192.810007.414336
1×411.4217.910004.615547
1×611.8247.710003.086859
1×1013.1310.210001.839181
1×1614.2387.310001.15117109
1×2516.7551.210000.727150146
1×3517.8661.110000.524179179
1×5019.5820.310000.387211218
1×7022.01084.110000.268257275
1×9523.91365.810000.193304336
1×12025.61617.210000.153341388
1×15027.71957.210000.124377438
1×18530.02365.210000.0991418501
1×24033.83037.05000.0754469508
1×30036.93804.15000.0601514654
1×40040.94710.05000.0470565733
02

2 Core

N2XRH FE 180 · Steel wire armour

Cross Section
mm²
Overall Ø
mm
Net Weight
kg/km
Delivery
m
Resistance 20°C
Ω/km
In Ground 20°C
A
In Air 30°C
A
2×1.513.8358.1100012.13125
2×2.514.6405.810007.414033
2×416.4564.610004.615243
2×617.4650.110003.086554
2×1019.9830.810001.838775
2×1622.81164.410001.15113100
2×2526.01534.310000.727146136
2×3528.41870.710000.524176165
2×5031.92377.010000.387208201
2×7036.63204.05000.268256255
2×9541.14110.85000.193307314
2×12045.95144.85000.153349364
2×15050.76351.75000.124391416
2×18555.27506.12500.0991442480
2×24061.59183.42500.0754509565
2×30066.911012.72500.0601569643
2×40076.214541.82500.0470637737
03

3 Core

N2XRH FE 180 · Steel wire armour

Cross Section
mm²
Overall Ø
mm
Net Weight
kg/km
Delivery
m
Resistance 20°C
Ω/km
In Ground 20°C
A
In Air 30°C
A
3×1.514.3391.6100012.13125
3×2.515.2449.210007.414033
3×417.1614.710004.615243
3×4 rm17.6657.510004.615243
3×618.1738.510003.086554
3×1020.9958.910001.838775
3×1623.91360.810001.15113100
3×2527.41849.710000.727146136
3×3530.12238.110000.524176165
3×5034.73075.710000.387208201
3×7039.33998.410000.268256255
3×9543.75059.75000.193307314
3×12048.86407.55000.153349364
3×15053.97807.85000.124391416
3×18558.89335.32500.0991442480
3×24065.511423.12500.0754509565
3×30071.413859.02500.0601569643
3×40081.818162.62500.0470637737
3+

3 Core + Reduced Conductor

Power cable configurations with reduced conductor

Cross Section
mm²
Overall Ø
mm
Net Weight
kg/km
Delivery
m
Resistance 20°C
Ω/km
In Ground 20°C
A
In Air 30°C
A
3×16+1025.11579.810001.15 – 1.83113100
3×25+1628.82145.610000.727 – 1.15146136
3×35+1631.02526.710000.524 – 1.15176165
3×50+2536.03523.310000.387 – 0.727208201
3×70+3540.74441.55000.268 – 0.524256255
3×95+5046.56088.55000.193 – 0.387307314
3×120+7051.57375.75000.153 – 0.268349364
3×150+7055.58672.02500.124 – 0.268391416
3×185+9561.310389.32500.0991 – 0.193442480
3×240+12067.712645.72500.0754 – 0.153509565
3×300+15075.316355.62500.0601 – 0.124569643
3×400+18584.319966.32500.0470 – 0.0991637737
04

4 Core

N2XRH FE 180 · Steel wire armour

Cross Section
mm²
Overall Ø
mm
Net Weight
kg/km
Delivery
m
Resistance 20°C
Ω/km
In Ground 20°C
A
In Air 30°C
A
4×1.516.1518.7100012.13125
4×2.517.0600.610007.414033
4×418.2751.610004.615243
4×619.3879.210003.086554
4×1023.11306.110001.838775
4×1625.71695.910001.15113100
4×2529.82325.210000.727146136
4×3533.63061.610000.524176165
4×5038.34005.110000.387208201
4×7042.95169.25000.268256255
4×9548.97004.25000.193307314
4×12053.98442.25000.153349364
4×15059.210138.92500.124391416
4×18565.112186.82500.0991442480
4×24073.516058.02500.0754509565
4×30080.519349.12500.0601569643
4×40090.123406.72500.0470637737
4+

4 Core + Reduced Conductor

Power cable configurations with reduced conductor

Cross Section
mm²
Overall Ø
mm
Net Weight
kg/km
Delivery
m
Resistance 20°C
Ω/km
In Ground 20°C
A
In Air 30°C
A
4×16+1027.11905.510001.15 – 1.83113100
4×25+1631.52650.610000.727 – 1.15146136
4×35+1635.03404.210000.524 – 1.15176165
4×50+2540.14483.210000.387 – 0.727208201
4×70+3546.06179.45000.268 – 0.524256255
4×95+5051.77959.85000.193 – 0.387307314
4×120+7056.89711.25000.153 – 0.268349364
4×150+7062.011359.42500.124 – 0.268391416
4×185+9568.013719.32500.0991 – 0.193442480
4×240+12076.717994.72500.0754 – 0.153509565
4×300+15084.121793.82500.0601 – 0.124569643
4×400+18593.926486.42500.0470 – 0.0991637737
05

5 Core

N2XRH FE 180 · Steel wire armour

Cross Section
mm²
Overall Ø
mm
Net Weight
kg/km
Delivery
m
Resistance 20°C
Ω/km
In Ground 20°C
A
In Air 30°C
A
5×1.517.0593.6100012.13125
5×2.518.1695.310007.414033
5×419.3842.310004.615243
5×620.6999.410003.086554
5×1024.81540.010001.838775
5×1627.72013.010001.15113100
5×2533.32947.210000.727146136
5×3536.63699.110000.524176165
5×5041.74824.15000.387208201
5×7047.96591.65000.268256255
5×9553.98601.55000.193307314
5×12058.910309.72500.153349364
5×15065.312345.92500.124391416
5×18571.414845.62500.0991442480
5×24081.119615.02500.0754509565
5×30088.323745.02500.0601569643
5×40099.128929.92500.0470637737
MC

Multicore

6 to 24 core standard configurations

Cross Section
mm²
Overall Ø
mm
Net Weight
kg/km
Delivery
m
Resistance 20°C
Ω/km
In Ground 20°C
A
In Air 30°C
A
6×1.518.2649.4100012.1
7×1.518.2676.9100012.116.012.5
7×2.519.3793.610007.4121.517.0
8×1.518.9737.8100012.1
12×1.522.01007.1100012.1
12×2.523.51230.910007.41
12×2.5 rm24.51283.110007.41
16×2.525.81455.610007.41
19×2.527.31625.210007.4111.09.0
19×2.5 rm28.71734.510007.4114.511.5
24×2.529.82028.910007.41
Need another configuration? Additional conductor arrangements may be available on request. Contact UNIMA CABLE with your project specification.
Technical note Current carrying capacities are based on the stated installation conditions. Actual permissible current depends on installation method, ambient conditions, grouping and applicable project requirements. Dimensions and weights are nominal values.

Technical Documentation

UNIMA CABLE

N2XRH FE 180 Fire Resistant Armoured Cable Cable Calculator

Calculate cable weight, copper content and approximate cable length.

m
Cable Weight 0 kg
Cable Length 0 m
Copper Content 0 kg
Copper Share 0 %
Cable weight: 0 kg/km
Copper: 0 kg/km
Approximate values based on technical cable data. Actual values may vary due to manufacturing tolerances.
distributor wire and cable 35kv sourcing
Unima d.d.

Why Unima Cable?

B2B partner for cable distribution across Europe and global industrial projects

Years of Experience
0 +
Fast Delivery
0 +h
Technical Documentation Files
0 +
Markets Served
0 +