UNIMA CABLE | LOW VOLTAGE POWER CABLES
NYCWY – Power Cable with Concentric Copper Conductor
0.6/1 kV PVC-insulated copper power cable with a concentric copper conductor and UV-resistant black PVC outer sheath, designed for fixed installations.
NYCWY
0.6/1 kV
Copper
Concentric Cu
PVC
CPR Eca
Product Overview
NYCWY is a low-voltage power cable with bare copper conductors, PVC core insulation, a concentric copper conductor and a black PVC outer sheath.
Suitable for fixed installation indoors, outdoors, underground, in water and in concrete. The cable is UV-resistant and flame-retardant according to IEC 60332-1-2.
Key Technical Features
0.6/1 kV
Rated Voltage
+70°C
Max. Conductor Temperature
12 × D
Multicore Bending Radius
Eca
CPR Classification
Construction & Technical Properties
Cable Construction
Conductor
Bare Copper
Conductor Class
Class 1; Class 2 from 25 mm²
Core Insulation
PVC DIV 4
Concentric Conductor
Copper
Outer Sheath
PVC DMV 5
Sheath Colour
Black
Core Identification
VDE 0293 / HD 308
Electrical & Mechanical Data
Rated Voltage
0.6/1 kV
Max. System Voltage
1.2 kV
Nominal DC Voltage
1.8/1.8 kV
Test Voltage
4 kV
Max. Conductor Temp.
+70°C
Movement Temperature
-5°C to +70°C
Bending Radius
12 × D multicore / 15 × D single-core
UV Resistance
Yes
Flame Retardance
IEC 60332-1-2
Typical Applications
Fixed Indoor Installations
Outdoor Installations
Underground Cable Installations
Installation in Water
Installation in Concrete
Power Distribution Networks
Applicable Standards
VDE 0276-603 – Power Cable Standard
VDE 0293 / HD 308 – Core Identification
IEC 60332-1-2 – Flame Propagation Test
VDE 0482-332-1-2 – Flame Retardance
EN 50575 – CPR Classification: Eca
VDE 0293 / HD 308 – Core Identification
IEC 60332-1-2 – Flame Propagation Test
VDE 0482-332-1-2 – Flame Retardance
EN 50575 – CPR Classification: Eca
Technical Notice:
Dimensions, weights and current ratings depend on
the selected cable configuration and installation
conditions. Values are indicative and subject to
technical confirmation. CPR documentation and
availability should be confirmed before ordering.
UNIMA CABLE | NYCWY PRODUCT RANGE
Available Cable Dimensions
NYCWY 0.6/1 kV copper power cable with concentric copper conductor. Technical dimensions and weights for the available configurations.
40
Cable Configurations
0.6/1 kV
Rated Voltage
Cu
Concentric Conductor
Eca
CPR Class
| Cable Configuration (mm²) |
Outer Diameter (mm) |
Copper Weight (kg/km) |
Cable Weight (kg/km) |
|---|---|---|---|
| 1 × 95 / 50 | 24 | 1472 | 1761 |
| 1 × 240 / 120 | 32.6 | 3634 | 4067 |
| 2 × 10 / 10 | 19.4 | 312 | 610 |
| 2 × 16 / 16 | 20.4 | 489 | 840 |
| 2 × 16 RM / 16 | 21.3 | 489 | 896 |
| 2 × 25 / 16 | 24.4 | 662 | 1299 |
| 2 × 25 / 25 | 25.1 | 763 | 1340 |
| 2 × 50 / 25 | 30.3 | 1243 | 2045 |
| 3 × 10 / 10 | 19.4 | 408 | 750 |
| 3 × 16 / 16 | 21.4 | 643 | 1050 |
| 3 × 25 / 16 | 25.5 | 902 | 1600 |
| 3 × 35 / 16 | 27.6 | 1190 | 1700 |
| 3 × 50 / 25 | 28.7 | 1723 | 2300 |
| 3 × 70 / 35 | 32.8 | 2410 | 2900 |
| 3 × 95 / 50 | 37.8 | 3296 | 4000 |
| 3 × 120 / 70 | 40.8 | 4236 | 5000 |
| 3 × 150 / 70 | 45 | 5100 | 6000 |
| 3 × 185 / 95 | 50 | 6383 | 7500 |
| 3 × 240 / 120 | 57 | 8242 | 10000 |
| 3 × 25 / 25 | 25.5 | 1003 | 1600 |
| 3 × 35 / 35 | 25.7 | 1402 | 1850 |
| 3 × 50 / 50 | 28.7 | 2000 | 2400 |
| 3 × 70 / 70 | 33.8 | 2796 | 3300 |
| 3 × 95 / 95 | 37.8 | 3791 | 4500 |
| 3 × 120 / 120 | 41.8 | 4786 | 5500 |
| 3 × 150 / 150 | 46 | 5970 | 6750 |
| 3 × 300 / 150 | 60.5 | 10290 | 11615 |
| 4 × 10 / 10 | 20.4 | 504 | 870 |
| 4 × 16 / 16 | 23.4 | 796 | 1250 |
| 4 × 16 RM / 16 | 23.4 | 796 | 1250 |
| 4 × 25 / 16 | 27.6 | 1142 | 1800 |
| 4 × 35 / 16 | 28.6 | 1526 | 2050 |
| 4 × 50 / 25 | 32.8 | 2203 | 2700 |
| 4 × 70 / 35 | 36.8 | 3082 | 3750 |
| 4 × 95 / 50 | 43.9 | 4208 | 5000 |
| 4 × 120 / 70 | 47 | 5388 | 6300 |
| 4 × 150 / 70 | 51 | 6540 | 7600 |
| 4 × 185 / 95 | 56 | 8159 | 9300 |
| 4 × 240 / 120 | 63 | 10546 | 11600 |
| 4 × 300 / 150 | 69.6 | 13170 | 15331 |
Technical Notice:
Dimensions and weights are approximate and may vary
depending on production tolerances. Cable availability,
packaging and CPR documentation must be confirmed
before ordering.