N2XH-J / N2XH-O – Halogen-Free Power Cable 0.6/1 kV


Technical Specifications

  • N2XH-J / N2XH-O
  • Cable Type
  • Fixed indoor installations, buildings, public infrastructure and concrete installations
  • Application
  • VDE 0276-604, IEC 60332-3-24, IEC 60754, IEC 61034
  • Standard

Details

  • Insulation Material XLPE (2XI1), halogen-free FRNC outer sheath (HM4)
  • Packaging Wooden drums / coils, depending on cross-section
  • Availability Stock
  • Rated Voltage 0.6/1 kV
  • Conductor Copper, Class 1 / 2
  • Insulation XLPE
  • Outer Sheath Halogen-free FRNC
  • Sheath Colour Black
  • Max. Conductor Temperature +90°C
  • Test Voltage 4 kV
  • Halogen Free / Yes
  • Low Smoke Emission Yes
  • Protective Conductor J: With PE / O: Without PE
  • Conductor Material Copper – Class 1 / Class 2
  • Cable Group Power cables 1 - 30 kV
  • Insulation Material XLPE (2XI1), halogen-free FRNC outer sheath (HM4)
  • Rated Voltage 0.6/1 kV
  • CPR Class Cca / Dca / Eca – depending on variant and DoP
  • Standard VDE 0276-604, IEC 60332-3-24, IEC 60754, IEC 61034
0.6/1 kVRATED VOLTAGE
Class 1 / 2COPPER CONDUCTOR
1.5–500 mm²RANGE ACROSS J / O VARIANTS
12× / 15× ØMULTICORE / SINGLE-CORE BENDING
Cca / Dca / EcaCPR – VARIANT DEPENDENT

N2XH-J / N2XH-O Cable Technical Data

N2XH-J and N2XH-O are halogen-free, low-smoke, flame-retardant 0.6/1 kV copper power cables with XLPE insulation and black FRNC outer sheath. N2XH-J includes a green/yellow protective conductor; N2XH-O does not.

Applications: Fixed installation indoors, in air and in concrete. Not suitable for direct burial in the ground or installation in water. CPR classification must be confirmed for the specific product and declaration of performance.

N2XH-J – Standard Cable Configurations

Cable Formation
n × mm²
Conductor
Type
Outer Diameter
mm
Approx. Weight
kg/km
Conductor Resistance
Ω/km @ 20°C
Copper Weight
kg/km
03 × 1.5RE1217912.143
03 × 2.5RE132257.4172
03 × 4RE142914.61115
03 × 6RE153713.08173
03 × 10RE165231.83288
03 × 16RE207731.15461
03 × 25RM2212000.727720
03 × 35SM2516000.5241008
03 × 50SMv2618000.3871440
03 × 25/16RM2412000.727874
03 × 35/16SM2616400.5241162
03 × 50/25SMv3222000.3871680
03 × 70/35SMv3729500.2682352
03 × 95/50SMv4139000.1933216
03 × 120/70SMv4548000.1534128
03 × 150/70SMv4957500.1244992
03 × 185/95SMv5572000.09916240
03 × 240/120SMv6291500.07548064
04 × 1.5RE1320812.158
04 × 2.5RE142657.4196
04 × 4RE153524.61154
04 × 6RE164543.08230
04 × 10RE186471.83384
04 × 16RE209641.15614
04 × 25RM2614460.727960
04 × 35SM2919060.5241344
04 × 50SMv3225300.3871920
04 × 70SMv3734180.2682688
04 × 95SMv4145740.1933648
04 × 120SMv4853000.1534608
04 × 150SMv5063500.1245760
04 × 185SMv5378000.09917104
04 × 240SMv58103000.07549216
04 × 300SMv59122010.060111520
05 × 1.5RE1424312.172
05 × 2.5RE153107.41120
05 × 4RE164134.61192
05 × 6RE175363.08288
05 × 10RE197761.83480
05 × 16RE2211651.15768
05 × 25RM2517660.7271200
05 × 35RM2921550.5241680
05 × 50RMv3325690.3872400
05 × 95 SM (reference)SMv3748740.1934560
05 × 120RMv4867740.1535760
05 × 120 SM (reference)SMv4662170.1535760
05 × 150 SM (reference)SMv5177070.1247200
05 × 185 SM (reference)SMv5694670.09918880
07 × 1.5RE1420612.1101
07 × 6RE165693.08403.2
07 × 10RE188591.83672
10 × 1.5RE1728712.1144
12 × 1.5RE1732812.1173
14 × 1.5RE1738312.1202
19 × 1.5RE1948412.1274
24 × 1.5RE2260312.1346
30 × 1.5RE2373012.1432
40 × 1.5RE26120012.1576
07 × 2.5RE152877.41168
10 × 2.5RE184727.41240
12 × 2.5RE184727.41288
14 × 2.5RE196707.41336
19 × 2.5RE218407.41456
24 × 2.5RE2510507.41576
30 × 2.5RE2612307.41720
07 × 4RE155304.61269
12 × 4RE218204.61461
14 × 4RE207654.61538
17 × 4RE229474.61653
01 × 4RE91404.6138
01 × 6RE101603.0858
01 × 10RE112101.8396
01 × 16RE122701.15154
01 × 25RM143800.727240
01 × 35RMv154900.524336
01 × 50RMv166200.387480
01 × 70RMv188300.268672
01 × 95RMv2012000.193912
01 × 120RMv2212500.1531152
01 × 150RMv2417000.1241440
01 × 185RMv2622000.09911776
01 × 240RMv2927500.07542304
04 × 25/16RM26.115390.7271114
04 × 35/16SMv29.419650.5241498
04 × 50/25SMv30.824450.3872160
04 × 70/35SMv34.633420.2683024
04 × 185/95SMv52.885080.09918016

N2XH-O – Standard Cable Configurations

Cable Formation
n × mm²
Conductor
Type
Outer Diameter
mm
Approx. Weight
kg/km
Conductor Resistance
Ω/km @ 20°C
Copper Weight
kg/km
01 × 4RE91404.6138
01 × 6RE101603.0858
01 × 10RE112101.8396
01 × 16RE122701.15154
01 × 25RM143800.727240
01 × 35RM154900.524336
01 × 50RMv166200.387480
01 × 70RMv188300.268672
01 × 95RMv2012000.193912
01 × 120RMv2212500.1531152
01 × 150RMv2417000.1241440
01 × 185RMv2622000.09911776
01 × 240RMv2927500.07542304
01 × 300RMv3033000.06012880
01 × 400RMv3244200.0473840
01 × 500RMv3748660.03664800
02 × 1.5RE1218012.129
03 × 1.5RE1217912.143
02 × 2.5RE12.12107.4148
03 × 2.5RE132257.4172
02 × 4RE132704.6177
02 × 6RE143403.08115
02 × 10RE164501.83192
02 × 16RE186001.15307
02 × 25RM239800.727480
04 × 4RE153524.61154
04 × 6RE164543.08230
04 × 10RE186471.83384
04 × 16RE209641.15614
04 × 25RM2614460.727960
04 × 35SM2919060.5241344
04 × 50SMv3225300.3871920
04 × 70SMv3734180.2682688
04 × 95SMv4145740.1933648
04 × 120SMv4853000.1534608
04 × 150SMv5063500.1245760
04 × 185SMv5378000.09917104
04 × 240SMv58103000.07549216
10 × 1.5RE1728712.1144
Reading the tables: Dimensions and weights are approximate and depend on the specific cable configuration. Conductor types: RE = round solid, RM = round stranded, SM = sector-shaped stranded; “v” denotes compacted conductor. Resistance values and masses follow the supplied manufacturer's data. For mixed cross-sections, the displayed resistance refers to the main conductor.

Cable Construction

ConductorBare copper, Class 1; Class 2 from 25 mm²
InsulationXLPE, type 2XI1
Outer SheathHalogen-free FRNC compound HM4, black
N2XH-JWith green/yellow protective conductor
N2XH-OWithout green/yellow protective conductor
Bending RadiusMulticore 12 × Ø; single-core 15 × Ø (fixed)

Installation Conditions

Designed for fixed installation indoors, in air and in concrete. Not intended for direct burial in soil or use in water. Permitted cable outer temperature: -30°C to +70°C when fixed and -5°C to +70°C when moved.

Electrical & Temperature Characteristics

Rated VoltageU₀/U 0.6/1 kV
Maximum AC System Voltage1.2 kV (three-phase)
Test Voltage4 kV
Maximum Conductor Temperature+90°C
Fixed Cable Temperature-30°C to +70°C
Moved Cable Temperature-5°C to +70°C

Standards & Compliance

Product standard: VDE 0276-604
CPR: EN 50575 – Cca, Dca or Eca on request (subject to product variant and DoP)
Flame retardance: IEC 60332-3-24 (Category C)
Smoke density: IEC 61034
Halogen-free: IEC 60754
Core identification: VDE 0293 / HD 308 as applicable

Technical values are taken from the supplied Klaus Faber AG N2XH-J/-O datasheet. Actual availability, CPR rating and technical documentation must be confirmed for the ordered configuration. Flame-retardant performance does not imply FE180 or E30/E90 circuit integrity.

Technical Documentation

Technical Data Sheet

EU declaration of conformity

Core Identification

Maximum 2 cross-sections per Data Sheet. 1 selected
UNIMA CABLE

N2XH-J / N2XH-O Cable Calculator

Halogen-Free Power Cable 0.6/1 kV

Calculate cable weight, copper content and approximate cable length.

m
Cable Weight 0 kg
Cable Length 0 m
Copper Content 0 kg
Copper Share 0 %
Cable weight: 0 kg/km
Copper: 0 kg/km
Approximate values based on technical cable data. Actual values may vary due to manufacturing tolerances.
distributor wire and cable 35kv sourcing
Unima d.d.

Why Unima Cable?

B2B partner for cable distribution across Europe and global industrial projects

Years of Experience
0 +
Fast Delivery
0 +h
Technical Documentation Files
0 +
Markets Served
0 +