A-2YF(L)2Y – Water-Blocked Telecommunications Cable

PE-insulated copper telecommunications cable with star-quad construction, petrolatum gel filling, laminated aluminium screen and black polyethylene outer sheath. Designed for local communication networks, underground installations and low-frequency industrial communication systems.

2–150 Pairs Solid Copper 0.6 / 0.8 mm PE Insulation Gel Filled Star-Quad Construction Aluminium Screen PE Sheath Water Blocking DIN VDE 0816

Product Overview

A-2YF(L)2Y is a screened, polyethylene-insulated telecommunications cable designed for local communication networks and predominantly low-frequency installations.

The cable incorporates solid bare copper conductors with nominal diameters of 0.6 mm or 0.8 mm. Individual conductors are insulated with polyethylene and arranged in star quads.

The interstices of the cable core are continuously filled with petrolatum gel to provide longitudinal protection against water penetration.

A plastic-coated aluminium tape forms the electrostatic screen and contributes to transverse moisture protection. The outer sheath consists of black polyethylene.

The longitudinally and transversely water-blocked construction is suitable for underground installations, cable ducts, conduits and communication networks within industrial and operational facilities.

Key Technical Features

2–150Number of Pairs
0.6 / 0.8 mmConductor Diameter
225 VPeak Operating Voltage
+70°CMax. Fixed Installation Temperature

Cable Variants

0.6 mm Copper Conductor

2–100 pairs

Solid bare copper conductors with a nominal diameter of 0.6 mm.

Conductor loop resistance: 130.0 Ω/km.

Approximate outer diameter: 8.3–30.3 mm.

Eight reference configurations.

0.8 mm Copper Conductor

2–150 pairs

Solid bare copper conductors with a nominal diameter of 0.8 mm.

Conductor loop resistance: 73.2 Ω/km.

Approximate outer diameter: 8.8–42.2 mm.

Ten reference configurations.

Construction & Technical Properties

Cable Construction

Conductor MaterialBare Copper
Conductor ConstructionSolid, Class 1
Conductor Diameter0.6 / 0.8 mm
Number of Pairs2–150
Core InsulationPolyethylene (PE)
Core ArrangementStar Quads
Core FillingPetrolatum Gel
Wrapping LayerPlastic Foil
Electrostatic ScreenPlastic-Coated Aluminium Tape
Longitudinal Water BlockingYes
Transverse Water BlockingYes
Outer SheathPolyethylene (PE)
Sheath ColourBlack

Electrical & Mechanical Data

Peak Operating Voltage225 V
Test Voltage Core/Core500 V AC, 50 Hz
Test Voltage Core/Screen2000 V AC, 50 Hz
Loop Resistance Ø 0.6 mm130.0 Ω/km
Loop Resistance Ø 0.8 mm73.2 Ω/km
Min. Insulation Resistance1500 MΩ/km
Max. Operating Capacitance52 nF/km
Max. Capacitance Unbalance800 pF / 100 m
Temperature During Bending-20°C to +50°C
Fixed Installation Temperature-20°C to +70°C
Minimum Bending Radius15 x Cable Diameter
Approx. Outer Diameter8.3–42.2 mm
Approx. Cable Weight67–2553 kg/km

Water-Blocking Construction

Longitudinal Water Protection

The cable core interstices are continuously filled with petrolatum gel to restrict longitudinal water migration within the cable.

Transverse Water Protection

The plastic-coated aluminium tape and polyethylene outer sheath provide the transverse moisture-protection construction specified for this cable type.

Typical Applications

Local Telecommunications Networks
Underground Communication Networks
Industrial Communication Infrastructure
Low-Frequency Communication Systems
Cable Duct Installations
Conduit Installations
Operational Facility Networks
Utility Communication Infrastructure

Installation Methods

A-2YF(L)2Y telecommunications cables are suitable for installation directly in the ground, in conduits and in cable ducts.

The specified minimum bending radius during bending is 15 times the overall cable diameter.

The permitted temperature range during bending is -20°C to +50°C. For fixed installations, the specified temperature range is -20°C to +70°C.

Installation conditions and mechanical protection requirements must be assessed for the individual project.

Applicable Standards

DIN VDE 0816 – Reference standard for core identification.

DIN EN 60228, Class 1 – Reference standard for solid conductor construction.

Technical Note: Cable dimensions, copper content and weights depend on the selected configuration. The nominal conductor dimensions of 0.6 mm and 0.8 mm refer to conductor diameter, not conductor cross-sectional area. CPR classification, flame retardancy, UV resistance and maximum tensile load are not specified in the reference documentation. All technical characteristics must be confirmed for the supplied product.
UNIMA CABLE | TECHNICAL DIMENSIONS

A-2YF(L)2Y – Cable Sizes & Technical Data

Complete reference range of water-blocked copper telecommunications cables with 0.6 mm and 0.8 mm solid copper conductors, including cable dimensions, copper content, cable weights, electrical characteristics and installation parameters.

18Reference Configurations
2–150Number of Pairs
8.3–42.2 mmOuter Diameter
67–2553 kg/kmCable Weight

Available Cable Sizes & Construction Data

Cable Size Number of Pairs Conductor Diameter (mm) Copper Content (kg/km) Insulation Thickness* (mm) Approx. Outer Diameter (mm) Approx. Weight (kg/km)
A-2YF(L)2Y – 0.6 mm Solid Copper Conductors
2x2x0.620.612.51.88.367
6x2x0.660.634.61.811.0126
10x2x0.6100.656.61.812.5171
20x2x0.6200.6110.41.815.8287
30x2x0.6300.6165.11.819.0409
40x2x0.6400.6218.91.820.4503
50x2x0.6500.6273.61.822.2606
100x2x0.61000.6545.32.030.31155
A-2YF(L)2Y – 0.8 mm Solid Copper Conductors
2x2x0.820.821.11.88.883
4x2x0.840.839.41.811.2134
6x2x0.860.859.51.812.0165
10x2x0.8100.898.91.814.0232
20x2x0.8200.8194.91.819.1445
30x2x0.8300.8291.81.822.0588
40x2x0.8400.8387.82.024.0748
50x2x0.8500.8484.82.026.0910
100x2x0.81000.8967.72.236.01787
150x2x0.81500.81451.52.242.22553

Cable sizes are expressed as number of pairs x two conductors x nominal conductor diameter in millimetres. Cable diameters and weights are approximate.

*The thickness values of 1.8–2.2 mm are reproduced under the insulation thickness heading used in the reference documentation. The specific cable layer to which these values apply must be confirmed before technical approval.

Conductor Characteristics

Parameter 0.6 mm Conductor 0.8 mm Conductor
Conductor MaterialBare CopperBare Copper
Conductor ConstructionSolid, Class 1Solid, Class 1
Nominal Conductor Diameter0.6 mm0.8 mm
Calculated Geometric Cross-Section0.283 mm²0.503 mm²
Conductor Loop Resistance130.0 Ω/km73.2 Ω/km
Number of Pairs2–1002–150
Reference Configurations810
Core ArrangementStar QuadsStar Quads
Core InsulationPEPE

Geometric conductor cross-sections are calculated from the nominal conductor diameters using the circular area formula. They are not independently declared nominal cross-sections.

Electrical Characteristics

Parameter Reference Value
Peak Operating Voltage225 V
Test Voltage Core/Core at 50 Hz500 V AC
Test Voltage Core/Screen at 50 Hz2000 V AC
Loop Resistance – 0.6 mm130.0 Ω/km
Loop Resistance – 0.8 mm73.2 Ω/km
Minimum Insulation Resistance1500 MΩ/km
Maximum Operating Capacitance52 nF/km
Maximum Capacitance Unbalance per 100 m800 pF

Temperature & Mechanical Characteristics

Parameter Reference Value
Temperature During Bending-20°C to +50°C
Fixed Installation Temperature-20°C to +70°C
Minimum Bending Radius During Bending15 x D
Longitudinal Water BlockingYes
Transverse Water BlockingYes
Underground InstallationSuitable
Conduit InstallationSuitable
Cable Duct InstallationSuitable

Minimum Cable Bending Radius

Cable Size Approx. Outer Diameter (mm) Calculated Minimum Bending Radius – 15 x D (mm)
0.6 mm Conductor Diameter
2x2x0.68.3124.5
6x2x0.611.0165
10x2x0.612.5187.5
20x2x0.615.8237
30x2x0.619.0285
40x2x0.620.4306
50x2x0.622.2333
100x2x0.630.3454.5
0.8 mm Conductor Diameter
2x2x0.88.8132
4x2x0.811.2168
6x2x0.812.0180
10x2x0.814.0210
20x2x0.819.1286.5
30x2x0.822.0330
40x2x0.824.0360
50x2x0.826.0390
100x2x0.836.0540
150x2x0.842.2633

The minimum bending radii are calculated using the approximate outer diameters and the specified bending factor of 15 x D. Actual installation limits must be confirmed using the supplied cable dimensions.

Cable Construction Layers

Layer Component Material / Construction
1ConductorSolid Bare Copper, Ø 0.6 or 0.8 mm
2Core InsulationPolyethylene (PE)
3Core Filling and WrappingContinuous Petrolatum Gel Filling and Plastic Foil
4Electrostatic ScreenPlastic-Coated Aluminium Tape
5Outer SheathBlack Polyethylene (PE)

Applicable Standards

Standard Reference Application
DIN VDE 0816Core Identification
DIN EN 60228, Class 1Solid Conductor Construction
Technical Note: All cable dimensions, copper content and cable weights are indicative reference values. Cable sizes and technical configurations do not constitute a declaration of stock availability. Final technical specifications, installation conditions and applicable conformity documentation must be confirmed for the supplied product.
Data Verification: Conductor diameters are expressed in millimetres, not square millimetres. Geometric conductor cross-sections and minimum bending radii are calculated values. The thickness column and insulation resistance unit are reproduced as stated in the reference documentation and require confirmation for engineering calculations. CPR classification, UV resistance, maximum tensile load and detailed core colour sequences are not specified.