H05BQ-F – PUR Flexible Rubber Cable 300/500 V

Flexible rubber-insulated connection cable with Class 5 copper conductors and a durable orange polyurethane outer sheath. Designed for industrial facilities, construction sites and demanding working environments requiring high mechanical and abrasion resistance.

300/500 V 0.75–1 mm² 2–5 Cores Class 5 Copper EL6 Rubber Insulation PUR Outer Sheath Orange Sheath Oil Resistant Abrasion Resistant Outdoor Installation DIN VDE 0282-10

Product Overview

H05BQ-F is a flexible rubber-insulated connection and supply cable designed for demanding industrial and construction environments.

The cable incorporates fine-stranded bare or tinned copper conductors according to DIN EN 60228 Class 5, providing flexibility during installation and handling.

The individual conductors are insulated with EL6 rubber compound and protected by an orange polyurethane (PUR) outer sheath.

The polyurethane sheath provides high resistance to abrasion and mechanical stress, making the cable suitable for applications exposed to demanding working conditions.

H05BQ-F can be used in dry, damp and wet environments, as well as outdoors.

The reference product range includes conductor cross-sections of 0.75 and 1 mm², with configurations from 2 to 5 cores.

Key Technical Features

300/500 VRated Voltage
0.75–1 mm²Conductor Range
Class 5Flexible Copper
-40°C to +90°CTemperature During Bending

Cable Variants

H05BQ-F 0.75 mm²

2X0.75 / 3G0.75 / 4G0.75 / 5G0.75

Flexible cable configurations with 0.75 mm² copper conductors.

Approximate outer diameter: 6.8–8.8 mm.

Approximate cable weight: 51–97 kg/km.

H05BQ-F 1 mm²

2X1 / 3G1 / 4G1 / 5G1

Flexible cable configurations with 1 mm² copper conductors.

Approximate outer diameter: 7.4–9.4 mm.

Approximate cable weight: 61–116 kg/km.

Construction & Technical Properties

Cable Construction

Conductor MaterialBare or Tinned Copper
Conductor ConstructionFine-Stranded, Flexible
Conductor ClassClass 5
Conductor StandardDIN EN 60228
Conductor Cross-Section0.75–1 mm²
Number of Cores2–5
Core InsulationEL6 Rubber Compound
Core IdentificationHD 308 S2
Protective EarthG Versions
Overall ScreenNone in Reference Construction
ArmourNone in Reference Construction
Outer SheathPolyurethane (PUR)
Sheath ColourOrange

Electrical & Mechanical Data

Rated Voltage U0/U300/500 V
Test Voltage2000 V AC
Temperature During Bending-40°C to +90°C
Short-Circuit Temperature+200°C
Maximum Short-Circuit Duration5 Seconds
Bending Radius – Fixed4 x Cable Diameter
Bending Radius – During Bending5 x Cable Diameter
Oil ResistanceEN 60811-2-1
Flame PropagationEN 60332-1-2
Abrasion ResistanceHigh
Mechanical Stress ResistanceHigh
Outdoor InstallationSuitable
Approx. Outer Diameter6.8–9.4 mm
Approx. Cable Weight51–116 kg/km

PUR Outer Sheath & Mechanical Protection

Polyurethane Outer Sheath

The polyurethane outer sheath provides high abrasion resistance and protection against mechanical stress.

This construction is particularly suitable for industrial facilities and construction sites where cables are exposed to demanding working conditions.

The orange outer sheath provides a clearly identifiable cable appearance.

Rubber Insulation & Flexibility

The EL6 rubber insulation and fine-stranded Class 5 copper conductors provide a flexible cable construction.

The specified temperature range during bending is -40°C to +90°C.

The minimum bending radius is 4 times the cable diameter for one-time bending or fixed installation and 5 times the cable diameter during bending.

Oil Resistance & Flame Performance

Oil Resistance

The reference documentation specifies oil resistance according to EN 60811-2-1.

Suitability for specific oils, chemicals and prolonged exposure conditions must be confirmed for the selected product.

Flame Propagation

The reference documentation specifies EN 60332-1-2 for single-cable vertical flame propagation performance.

CPR Euroclass, low-smoke performance, halogen-free properties and fire-resistant circuit integrity are not specified.

Typical Applications

Construction Sites
Industrial Facilities
Industrial Equipment Connections
Portable Electrical Equipment
Workshop Equipment
Flexible Power Supply Connections
Indoor and Outdoor Installations
Commercial Building Maintenance
Mechanically Demanding Environments
Applications Requiring Abrasion Resistance
Dry, Damp and Wet Environments
Industrial Maintenance Operations

Installation Conditions

H05BQ-F is suitable for use in dry, damp and wet environments, as well as outdoor installations.

The cable is intended for connection and supply applications exposed to high mechanical stress and abrasion.

The specified temperature range during bending is -40°C to +90°C.

The minimum bending radius for one-time bending or fixed installation is 4 times the cable outer diameter.

The minimum bending radius during bending is 5 times the cable outer diameter.

Suitability for permanent water immersion, direct burial, continuous-flex drag chains, cable reels and torsional applications is not established by the reference documentation.

Applicable Standards

DIN VDE 0282-10 – Reference construction standard for flexible cables with elastomeric insulation and polyurethane sheathing.

DIN EN 60228, Class 5 – Flexible copper conductor construction.

HD 308 S2 – Identification of cable cores.

HD 22.10 S1+A1 – Reference harmonisation document for the specified cable construction.

EN 60811-2-1 – Reference standard cited for oil resistance.

EN 60332-1-2 – Vertical flame propagation test for a single insulated wire or cable.

Related Flexible Cable Types

Polyurethane Sheathed Cables

H05BQ-F – Flexible rubber-insulated cable with PUR sheath, rated 300/500 V.

H07BQ-F – Related polyurethane-sheathed flexible cable type rated 450/750 V.

Rubber Sheathed Cables

H05RR-F – Related flexible rubber-insulated and rubber-sheathed cable type.

H07RN-F – Related flexible rubber cable type for demanding supply and connection applications.

Technical Note: The reference product range includes eight cable configurations from 0.75 to 1 mm². Cable dimensions, conductor construction and weights depend on the selected configuration. Related cable types are provided for product orientation and are not declarations of technical equivalence. Legacy standard designations are retained as stated in the reference documentation. CPR classification, halogen-free performance, continuous-flex suitability and additional electrical characteristics must be confirmed for the supplied product.
UNIMA CABLE | TECHNICAL DIMENSIONS

H05BQ-F – Cable Sizes & Technical Data

Complete reference range of flexible rubber-insulated, polyurethane-sheathed cables rated 300/500 V, including conductor construction, copper content, cable dimensions, approximate weights and installation parameters.

8Reference Configurations
0.75–1 mm²Conductor Cross-Section
2–5Number of Cores
51–116 kg/kmCable Weight

Available Cable Sizes & Construction Data

Cable Size (mm²) Number of Cores Copper Content (kg/km) Approx. Conductor Stranding Approx. Outer Diameter (mm) Approx. Cable Weight (kg/km)
H05BQ-F – 0.75 mm²
2X0.75214.424 x 0.216.851
3G0.75321.624 x 0.217.466
4G0.75428.824 x 0.217.979
5G0.75536.024 x 0.218.897
H05BQ-F – 1 mm²
2X1219.230 x 0.217.461
3G1328.830 x 0.217.876
4G1438.430 x 0.218.492
5G1548.030 x 0.219.4116

The letter G indicates a cable configuration including a green/yellow protective earth conductor. The letter X indicates a configuration without a green/yellow protective earth conductor.

Conductor stranding is expressed as the approximate number of individual wires multiplied by their nominal diameter in millimetres. Copper content values are reference figures and must not be interpreted as independently verified recoverable copper mass.

Conductor Construction by Cross-Section

Nominal Cross-Section (mm²) Approx. Conductor Stranding Conductor Class Reference Configurations
0.7524 x 0.21 mmClass 54
130 x 0.21 mmClass 54

Electrical Characteristics

Parameter Reference Value
Rated Voltage U0/U300/500 V
Test Voltage2000 V AC
Conductor MaterialBare or Tinned Copper
Conductor ConstructionFine-Stranded, Flexible
Conductor ClassClass 5
Conductor StandardDIN EN 60228
Core InsulationEL6 Rubber Compound
Core IdentificationHD 308 S2
Conductor DC ResistanceNot Specified
Current-Carrying CapacityNot Specified
Insulation ResistanceNot Specified

Temperature Characteristics

Installation / Operating Condition Minimum Temperature Maximum Temperature
During Bending-40°C+90°C
Fixed InstallationNot Separately SpecifiedNot Separately Specified
Short-Circuit ConditionNot Specified+200°C

Maximum short-circuit duration: 5 seconds. The specified temperature range of -40°C to +90°C refers to the conditions stated in the reference documentation for bending.

Minimum Cable Bending Radius

Cable Size (mm²) Approx. Outer Diameter (mm) One-Time Bending / Fixed Installation 4 x D (mm) During Bending 5 x D (mm)
H05BQ-F – 0.75 mm²
2X0.756.827.234.0
3G0.757.429.637.0
4G0.757.931.639.5
5G0.758.835.244.0
H05BQ-F – 1 mm²
2X17.429.637.0
3G17.831.239.0
4G18.433.642.0
5G19.437.647.0

Minimum bending radii are calculated from the approximate cable outer diameter using the specified bending factors of 4 x D and 5 x D. Actual installation requirements must be confirmed using the dimensions of the supplied cable.

Cable Construction Layers

Layer Component Material / Construction
1ConductorFine-Stranded Bare or Tinned Copper, Class 5
2Core InsulationEL6 Rubber Compound
3Outer SheathOrange Polyurethane (PUR)

Core Identification & Cable Configurations

Configuration Number of Cores Protective Earth Identification Standard
2X2NoHD 308 S2
3G3YesHD 308 S2
4G4YesHD 308 S2
5G5YesHD 308 S2

Mechanical & Environmental Characteristics

Parameter Reference Value
Outer Sheath MaterialPolyurethane (PUR)
Outer Sheath ColourOrange
Mechanical Stress ResistanceHigh
Abrasion ResistanceHigh
Oil ResistanceEN 60811-2-1
Dry EnvironmentsSuitable
Damp EnvironmentsSuitable
Wet EnvironmentsSuitable
Outdoor InstallationSuitable
Construction Site ApplicationsSuitable
Industrial ApplicationsSuitable
Minimum Bending Radius – Fixed4 x Cable Diameter
Minimum Bending Radius – During Bending5 x Cable Diameter
UV Resistance TestNot Specified
Ozone ResistanceNot Specified
Direct BurialNot Specified
Permanent Water ImmersionNot Specified
Continuous-Flex ApplicationsNot Specified
Torsional ApplicationsNot Specified
Maximum Pulling ForceNot Specified

Fire Performance Characteristics

Parameter Reference Standard / Value
Single Cable Flame PropagationEN 60332-1-2
Bunched Cable Flame PropagationNot Specified
CPR EuroclassNot Specified
Halogen-Free PerformanceNot Specified
Low Smoke PerformanceNot Specified
Fire-Resistant Circuit IntegrityNot Specified

Applicable Standards

Standard Reference Application
DIN VDE 0282-10Reference Flexible Cable Construction
DIN EN 60228Flexible Copper Conductors, Class 5
HD 308 S2Core Identification
HD 22.10 S1+A1Reference Harmonisation Document for Cable Construction
EN 60811-2-1Reference Oil Resistance Standard
EN 60332-1-2Single Cable Vertical Flame Propagation Test
Technical Note: All cable dimensions, conductor stranding, copper content and cable weights are indicative reference values. Published configurations do not constitute a declaration of stock availability. Final technical characteristics and conformity documentation must be confirmed for the supplied product.
Installation Note: The reference documentation specifies bending factors of 4 x D for one-time bending or fixed installation and 5 x D during bending. These values do not establish suitability for continuous-flex applications, drag chains or cable reel systems.
Data Verification: All eight reference cable configurations are included. Minimum bending radii are calculated from the published approximate cable diameters. Legacy standard designations are retained as stated in the reference documentation. Compliance with current standard editions, CPR classification and additional electrical parameters must be confirmed separately.

Technical Documentation

Technical Data Sheet

EU declaration of conformity

Core Identification

Send Us email - RFQ


UNIMA CABLE COLLECTION

Explore Our Cable Range

Discover cable types, technical specifications and solutions for your projects.

96 Cable Types Available