A-2Y(L)2Y St III Bd – Outdoor Telecommunication Cable

Outdoor subscriber line cable with solid copper conductors, polyethylene insulation, star-quad stranding and a bonded polyethylene outer sheath. Designed for outdoor telecommunication networks, direct burial and installation in water or concrete under suitable project conditions.

225 V Peak 2–500 Pairs Solid Copper Class 1 0.6 / 0.8 mm PE Insulation Bonded PE Sheath Star-Quad Stranding UV Resistant Direct Burial VDE 0816

Product Overview

A-2Y(L)2Y St III Bd is an outdoor copper telecommunication cable intended for subscriber line networks and fixed communication infrastructure.

The cable features solid bare copper conductors with nominal diameters of 0.6 mm or 0.8 mm, insulated with polyethylene compound 2YI1.

Four insulated conductors are twisted together to form a star-quad. Five star-quads are stranded into one sub-unit, with sub-units arranged in layers according to the selected cable configuration.

A foil screen and bonded polyethylene outer sheath provide transverse water protection. The cable is not longitudinally watertight.

The robust black polyethylene sheath is UV-resistant and permits outdoor installation and direct burial. Installation in water and concrete is also identified in the reference technical documentation.

The reference product range comprises 29 configurations, covering 2 to 500 pairs with approximate outer diameters between 9 and 56 mm.

Key Technical Features

225 VPeak Operating Voltage
2–500Number of Pairs
2 kVTest Voltage
+70°CMaximum Fixed Installation Temperature

Cable Variants

A-2Y(L)2Y – 0.6 mm

Solid Copper Conductor Diameter: 0.6 mm

15 reference configurations from 2 to 500 pairs.

Conductor loop resistance: 130 Ω/km.

Maximum operating capacitance: 52 nF/km.

Approximate cable diameter: 9–56 mm.

A-2Y(L)2Y – 0.8 mm

Solid Copper Conductor Diameter: 0.8 mm

14 reference configurations from 2 to 200 pairs.

Conductor loop resistance: 73.2 Ω/km.

Maximum operating capacitance: 55 nF/km.

Approximate cable diameter: 9–44 mm.

Cable Designation

AOutdoor Telecommunication Cable
2YPolyethylene Core Insulation
(L)2YBonded Foil and Polyethylene Sheath Construction
St III BdStar-Quad Construction with Bunched Sub-Units

Construction & Technical Properties

Cable Construction

Conductor MaterialBare Copper
Conductor ClassClass 1, Solid
Conductor Diameter0.6 / 0.8 mm
Core InsulationPolyethylene (PE)
Insulation Compound2YI1
Stranding UnitFour Conductors per Star-Quad
Sub-Unit ConstructionFive Star-Quads
Stranding ArrangementBunched Star-Quads in Layers
Core IdentificationColours and Ring Marking
Overall ScreenFoil
Outer SheathPolyethylene (PE)
Sheath Compound2YM1
Bonded SheathYes
Sheath ColourBlack

Electrical & Mechanical Data

Peak Operating Voltage225 V
Test Voltage2 kV
Loop Resistance – 0.6 mm130 Ω/km
Loop Resistance – 0.8 mm73.2 Ω/km
Operating Capacitance – 0.6 mmMax. 52 nF/km
Operating Capacitance – 0.8 mmMax. 55 nF/km
Attenuation at 800 Hz – 0.6 mm1.04 (Unit Not Specified)
Attenuation at 800 Hz – 0.8 mm0.78 (Unit Not Specified)
Fixed Cable Temperature-30°C to +70°C
Temperature During Movement-20°C to +50°C
Minimum Fixed Bending Radius7.5 x Cable Diameter
Installation Tensile Load300–11500 N, Depending on Size
Approximate Outer Diameter9–56 mm
Net Cable Weight80–4050 kg/km

Environmental & Installation Properties

Environmental Resistance

UV ResistanceYes
Outdoor InstallationYes
Transverse WatertightnessYes
Longitudinal WatertightnessNo
Flame RetardancyNot Flame-Retardant

Installation Methods

Outdoor LayingSuitable
Direct BurialSuitable
Installation in WaterListed in Reference Documentation
Installation in ConcreteSuitable
Indoor InstallationAdditional Fire Protection May Be Required

Typical Applications

Outdoor Telecommunication Networks
Subscriber Line Networks
Copper Telephone Distribution Networks
Underground Communication Infrastructure
Direct Burial Installations
Outdoor Commercial Building Communications
Industrial Communication Infrastructure
Utility Communication Networks

Applicable Standards

VDE 0816 – Reference standard for the outdoor telecommunication cable construction specified in the technical documentation.

PE 2YI1 – Reference polyethylene insulation compound designation.

PE 2YM1 – Reference polyethylene outer sheath compound designation.

Installation Conditions

The bonded polyethylene sheath permits outdoor installation, including direct burial.

The cable is transversely watertight but does not incorporate declared longitudinal water blocking. Installation in water must therefore be assessed according to the actual project conditions and cable termination arrangements.

During cable movement, the specified outer cable temperature range is -20°C to +50°C. For fixed installation, the permitted outer cable temperature range is -30°C to +70°C.

The minimum bending radius for fixed installation is 7.5 times the cable outer diameter.

Additional fire protection measures may be required when the cable is installed indoors because the polyethylene sheath is not flame-retardant.

Technical Note: The 225 V value represents peak operating voltage and is not a rated power distribution voltage. Conductor sizes of 0.6 mm and 0.8 mm refer to nominal conductor diameter, not cross-sectional area. The cable is transversely watertight but not longitudinally watertight. The PE sheath is not flame-retardant. CPR classification, attenuation units, maximum water immersion depth and dynamic bending radius are not specified in the reference documentation. Final cable characteristics and installation suitability must be confirmed for the supplied product.
UNIMA CABLE | TECHNICAL DIMENSIONS

A-2Y(L)2Y St III Bd – Cable Sizes & Technical Data

Complete reference range of outdoor subscriber line cables with 0.6 mm and 0.8 mm solid copper conductors, including cable dimensions, installation tensile loads, German copper weight values, net cable weights and electrical characteristics.

29Reference Configurations
2–500Number of Pairs
9–56 mmOuter Diameter
80–4050 kg/kmNet Cable Weight

Available Cable Sizes & Dimensions

Cable Type Configuration Number of Pairs Conductor Diameter (mm) Approx. Outer Diameter (mm) Installation Tensile Load (N) Copper Weight GER* Net Cable Weight (kg/km)
A-2Y(L)2Y St III Bd – Solid Copper Conductor Ø 0.6 mm
A-2Y(L)2Y2x2x0.620.693001180
A-2Y(L)2Y4x2x0.640.61135023120
A-2Y(L)2Y6x2x0.660.61240034130
A-2Y(L)2Y10x2x0.6100.613.550057155
A-2Y(L)2Y20x2x0.6200.616700113240
A-2Y(L)2Y30x2x0.6300.618950170310
A-2Y(L)2Y40x2x0.6400.6201200226385
A-2Y(L)2Y50x2x0.6500.6211500283460
A-2Y(L)2Y70x2x0.6700.6252000396605
A-2Y(L)2Y100x2x0.61000.6282800565870
A-2Y(L)2Y150x2x0.61500.63341008481345
A-2Y(L)2Y200x2x0.62000.638520011311755
A-2Y(L)2Y250x2x0.62500.641.5640014142140
A-2Y(L)2Y300x2x0.63000.644.5740016962525
A-2Y(L)2Y500x2x0.65000.6561150028274050
A-2Y(L)2Y St III Bd – Solid Copper Conductor Ø 0.8 mm
A-2Y(L)2Y2x2x0.820.893102090
A-2Y(L)2Y4x2x0.840.81238040140
A-2Y(L)2Y6x2x0.860.81348060160
A-2Y(L)2Y8x2x0.880.814–81180
A-2Y(L)2Y10x2x0.8100.815600101205
A-2Y(L)2Y12x2x0.8120.815.2–123250
A-2Y(L)2Y20x2x0.8200.818.51000201355
A-2Y(L)2Y30x2x0.8300.8211500302475
A-2Y(L)2Y40x2x0.8400.8232000402600
A-2Y(L)2Y50x2x0.8500.8262500503745
A-2Y(L)2Y70x2x0.8700.82934007041100
A-2Y(L)2Y100x2x0.81000.834460010051425
A-2Y(L)2Y150x2x0.81500.840660015082200
A-2Y(L)2Y200x2x0.82000.844850020112900

Cable configuration is expressed as number of pairs x two conductors x nominal conductor diameter in millimetres. A dash indicates a value not specified in the reference documentation.

*Copper Weight GER values are reproduced from the original Cu column, which is identified as Copper Weight (GER). The source does not explicitly state the unit for this column. These figures must not be interpreted as independently verified physical copper content.

Electrical Characteristics

Parameter 0.6 mm Conductor 0.8 mm Conductor
Conductor MaterialBare CopperBare Copper
Conductor ConstructionClass 1, SolidClass 1, Solid
Nominal Conductor Diameter0.6 mm0.8 mm
Calculated Geometric Cross-Section0.283 mm²0.503 mm²
Loop Resistance130 Ω/km73.2 Ω/km
Maximum Operating Capacitance52 nF/km55 nF/km
Test Voltage2 kV2 kV
Peak Operating Voltage225 V225 V
Attenuation at 800 Hz1.040.78
Core IdentificationColours and RingsColours and Rings
Reference Configurations1514
Number of Pairs2–5002–200

The attenuation unit is not specified in the reference documentation. Geometric conductor cross-sections are calculated from nominal conductor diameters and are provided for reference only.

Mechanical & Environmental Characteristics

Parameter Reference Value
Core InsulationPE 2YI1
Stranding UnitFour Conductors per Star-Quad
Sub-UnitFive Star-Quads
Stranding ArrangementBunched Star-Quads, Sub-Units in Layers
Overall ScreenFoil
Outer SheathPE 2YM1
Bonded SheathYes
Sheath ColourBlack
UV ResistanceYes
Transverse WatertightnessYes
Longitudinal WatertightnessNo
Flame RetardancyNone
Outdoor InstallationYes
Direct BurialYes
Installation in WaterListed in Reference Documentation
Installation in ConcreteYes
Minimum Bending Radius7.5 x D, Fixed Installation
Specified Installation Tensile Load Range300–11500 N

Temperature Characteristics

Condition Minimum Temperature Maximum Temperature
Fixed Cable-30°C+70°C
Cable During Movement-20°C+50°C

Temperature values refer to the permitted outer cable temperature.

Minimum Bending Radius – Fixed Installation

Configuration Approx. Outer Diameter (mm) Calculated Minimum Bending Radius – 7.5 x D (mm)
Conductor Diameter 0.6 mm
2x2x0.6967.5
4x2x0.61182.5
6x2x0.61290
10x2x0.613.5101.25
20x2x0.616120
30x2x0.618135
40x2x0.620150
50x2x0.621157.5
70x2x0.625187.5
100x2x0.628210
150x2x0.633247.5
200x2x0.638285
250x2x0.641.5311.25
300x2x0.644.5333.75
500x2x0.656420
Conductor Diameter 0.8 mm
2x2x0.8967.5
4x2x0.81290
6x2x0.81397.5
8x2x0.814105
10x2x0.815112.5
12x2x0.815.2114
20x2x0.818.5138.75
30x2x0.821157.5
40x2x0.823172.5
50x2x0.826195
70x2x0.829217.5
100x2x0.834255
150x2x0.840300
200x2x0.844330

Bending radii are calculated from approximate outer cable diameters using the specified fixed installation factor of 7.5 x D. These values do not establish a permissible dynamic bending radius during cable pulling.

Star-Quad Colour Identification

Star-Quad Position Identification Colour
1Red
2Green
3Grey
4Yellow
5White

The five star-quads within each bunch follow the continuous colour sequence red, green, grey, yellow and white.

Core Identification Within Each Star-Quad

Conductor Identification Ring Marking
a-wire 1Without Ring
b-wire 1One Ring, Widely Spaced
a-wire 2Double Ring, Widely Spaced
b-wire 2Double Ring, Narrowly Spaced

Applicable Technical Standards & Material Designations

Standard / Designation Reference Application
VDE 0816Outdoor Telecommunication Cable Construction
2YI1Polyethylene Insulation Compound
2YM1Polyethylene Outer Sheath Compound
Class 1Solid Copper Conductor Construction
Technical Note: All outer cable diameters and net cable weights are indicative. Reference configurations do not constitute a declaration of stock availability. The cable is transversely watertight but not longitudinally watertight. The polyethylene outer sheath is not flame-retardant. Additional fire protection measures may be required for indoor installation.
Data Verification: Installation tensile loads for configurations 8x2x0.8 and 12x2x0.8 are not specified in the reference documentation and have not been estimated. Attenuation values at 800 Hz are reproduced without an assumed unit. German copper weight values are reproduced as reference figures; their units and calculation basis must be confirmed. Net cable weights are interpreted as kilograms per 1000 metres. Minimum fixed bending radii and geometric conductor cross-sections are calculated values. CPR classification and dynamic bending radius are not specified. Final technical specifications and delivery conditions must be confirmed for the supplied product.

Technical Documentation

Technical Data Sheet

EU declaration of conformity

Core Identification