A-2Y(L)2Y St III Bd – Outdoor Telecommunication Cable
Outdoor subscriber line cable with solid copper conductors, polyethylene insulation, star-quad stranding and a bonded polyethylene outer sheath. Designed for outdoor telecommunication networks, direct burial and installation in water or concrete under suitable project conditions.
Product Overview
A-2Y(L)2Y St III Bd is an outdoor copper telecommunication cable intended for subscriber line networks and fixed communication infrastructure.
The cable features solid bare copper conductors with nominal diameters of 0.6 mm or 0.8 mm, insulated with polyethylene compound 2YI1.
Four insulated conductors are twisted together to form a star-quad. Five star-quads are stranded into one sub-unit, with sub-units arranged in layers according to the selected cable configuration.
A foil screen and bonded polyethylene outer sheath provide transverse water protection. The cable is not longitudinally watertight.
The robust black polyethylene sheath is UV-resistant and permits outdoor installation and direct burial. Installation in water and concrete is also identified in the reference technical documentation.
The reference product range comprises 29 configurations, covering 2 to 500 pairs with approximate outer diameters between 9 and 56 mm.
Key Technical Features
Cable Variants
A-2Y(L)2Y – 0.6 mm
Solid Copper Conductor Diameter: 0.6 mm
15 reference configurations from 2 to 500 pairs.
Conductor loop resistance: 130 Ω/km.
Maximum operating capacitance: 52 nF/km.
Approximate cable diameter: 9–56 mm.
A-2Y(L)2Y – 0.8 mm
Solid Copper Conductor Diameter: 0.8 mm
14 reference configurations from 2 to 200 pairs.
Conductor loop resistance: 73.2 Ω/km.
Maximum operating capacitance: 55 nF/km.
Approximate cable diameter: 9–44 mm.
Cable Designation
Construction & Technical Properties
Cable Construction
Electrical & Mechanical Data
Environmental & Installation Properties
Environmental Resistance
Installation Methods
Typical Applications
Applicable Standards
VDE 0816 – Reference standard for the outdoor telecommunication cable construction specified in the technical documentation.
PE 2YI1 – Reference polyethylene insulation compound designation.
PE 2YM1 – Reference polyethylene outer sheath compound designation.
Installation Conditions
The bonded polyethylene sheath permits outdoor installation, including direct burial.
The cable is transversely watertight but does not incorporate declared longitudinal water blocking. Installation in water must therefore be assessed according to the actual project conditions and cable termination arrangements.
During cable movement, the specified outer cable temperature range is -20°C to +50°C. For fixed installation, the permitted outer cable temperature range is -30°C to +70°C.
The minimum bending radius for fixed installation is 7.5 times the cable outer diameter.
Additional fire protection measures may be required when the cable is installed indoors because the polyethylene sheath is not flame-retardant.
A-2Y(L)2Y St III Bd – Cable Sizes & Technical Data
Complete reference range of outdoor subscriber line cables with 0.6 mm and 0.8 mm solid copper conductors, including cable dimensions, installation tensile loads, German copper weight values, net cable weights and electrical characteristics.
Available Cable Sizes & Dimensions
| Cable Type | Configuration | Number of Pairs | Conductor Diameter (mm) | Approx. Outer Diameter (mm) | Installation Tensile Load (N) | Copper Weight GER* | Net Cable Weight (kg/km) |
|---|---|---|---|---|---|---|---|
| A-2Y(L)2Y St III Bd – Solid Copper Conductor Ø 0.6 mm | |||||||
| A-2Y(L)2Y | 2x2x0.6 | 2 | 0.6 | 9 | 300 | 11 | 80 |
| A-2Y(L)2Y | 4x2x0.6 | 4 | 0.6 | 11 | 350 | 23 | 120 |
| A-2Y(L)2Y | 6x2x0.6 | 6 | 0.6 | 12 | 400 | 34 | 130 |
| A-2Y(L)2Y | 10x2x0.6 | 10 | 0.6 | 13.5 | 500 | 57 | 155 |
| A-2Y(L)2Y | 20x2x0.6 | 20 | 0.6 | 16 | 700 | 113 | 240 |
| A-2Y(L)2Y | 30x2x0.6 | 30 | 0.6 | 18 | 950 | 170 | 310 |
| A-2Y(L)2Y | 40x2x0.6 | 40 | 0.6 | 20 | 1200 | 226 | 385 |
| A-2Y(L)2Y | 50x2x0.6 | 50 | 0.6 | 21 | 1500 | 283 | 460 |
| A-2Y(L)2Y | 70x2x0.6 | 70 | 0.6 | 25 | 2000 | 396 | 605 |
| A-2Y(L)2Y | 100x2x0.6 | 100 | 0.6 | 28 | 2800 | 565 | 870 |
| A-2Y(L)2Y | 150x2x0.6 | 150 | 0.6 | 33 | 4100 | 848 | 1345 |
| A-2Y(L)2Y | 200x2x0.6 | 200 | 0.6 | 38 | 5200 | 1131 | 1755 |
| A-2Y(L)2Y | 250x2x0.6 | 250 | 0.6 | 41.5 | 6400 | 1414 | 2140 |
| A-2Y(L)2Y | 300x2x0.6 | 300 | 0.6 | 44.5 | 7400 | 1696 | 2525 |
| A-2Y(L)2Y | 500x2x0.6 | 500 | 0.6 | 56 | 11500 | 2827 | 4050 |
| A-2Y(L)2Y St III Bd – Solid Copper Conductor Ø 0.8 mm | |||||||
| A-2Y(L)2Y | 2x2x0.8 | 2 | 0.8 | 9 | 310 | 20 | 90 |
| A-2Y(L)2Y | 4x2x0.8 | 4 | 0.8 | 12 | 380 | 40 | 140 |
| A-2Y(L)2Y | 6x2x0.8 | 6 | 0.8 | 13 | 480 | 60 | 160 |
| A-2Y(L)2Y | 8x2x0.8 | 8 | 0.8 | 14 | – | 81 | 180 |
| A-2Y(L)2Y | 10x2x0.8 | 10 | 0.8 | 15 | 600 | 101 | 205 |
| A-2Y(L)2Y | 12x2x0.8 | 12 | 0.8 | 15.2 | – | 123 | 250 |
| A-2Y(L)2Y | 20x2x0.8 | 20 | 0.8 | 18.5 | 1000 | 201 | 355 |
| A-2Y(L)2Y | 30x2x0.8 | 30 | 0.8 | 21 | 1500 | 302 | 475 |
| A-2Y(L)2Y | 40x2x0.8 | 40 | 0.8 | 23 | 2000 | 402 | 600 |
| A-2Y(L)2Y | 50x2x0.8 | 50 | 0.8 | 26 | 2500 | 503 | 745 |
| A-2Y(L)2Y | 70x2x0.8 | 70 | 0.8 | 29 | 3400 | 704 | 1100 |
| A-2Y(L)2Y | 100x2x0.8 | 100 | 0.8 | 34 | 4600 | 1005 | 1425 |
| A-2Y(L)2Y | 150x2x0.8 | 150 | 0.8 | 40 | 6600 | 1508 | 2200 |
| A-2Y(L)2Y | 200x2x0.8 | 200 | 0.8 | 44 | 8500 | 2011 | 2900 |
Cable configuration is expressed as number of pairs x two conductors x nominal conductor diameter in millimetres. A dash indicates a value not specified in the reference documentation.
*Copper Weight GER values are reproduced from the original Cu column, which is identified as Copper Weight (GER). The source does not explicitly state the unit for this column. These figures must not be interpreted as independently verified physical copper content.
Electrical Characteristics
| Parameter | 0.6 mm Conductor | 0.8 mm Conductor |
|---|---|---|
| Conductor Material | Bare Copper | Bare Copper |
| Conductor Construction | Class 1, Solid | Class 1, Solid |
| Nominal Conductor Diameter | 0.6 mm | 0.8 mm |
| Calculated Geometric Cross-Section | 0.283 mm² | 0.503 mm² |
| Loop Resistance | 130 Ω/km | 73.2 Ω/km |
| Maximum Operating Capacitance | 52 nF/km | 55 nF/km |
| Test Voltage | 2 kV | 2 kV |
| Peak Operating Voltage | 225 V | 225 V |
| Attenuation at 800 Hz | 1.04 | 0.78 |
| Core Identification | Colours and Rings | Colours and Rings |
| Reference Configurations | 15 | 14 |
| Number of Pairs | 2–500 | 2–200 |
The attenuation unit is not specified in the reference documentation. Geometric conductor cross-sections are calculated from nominal conductor diameters and are provided for reference only.
Mechanical & Environmental Characteristics
| Parameter | Reference Value |
|---|---|
| Core Insulation | PE 2YI1 |
| Stranding Unit | Four Conductors per Star-Quad |
| Sub-Unit | Five Star-Quads |
| Stranding Arrangement | Bunched Star-Quads, Sub-Units in Layers |
| Overall Screen | Foil |
| Outer Sheath | PE 2YM1 |
| Bonded Sheath | Yes |
| Sheath Colour | Black |
| UV Resistance | Yes |
| Transverse Watertightness | Yes |
| Longitudinal Watertightness | No |
| Flame Retardancy | None |
| Outdoor Installation | Yes |
| Direct Burial | Yes |
| Installation in Water | Listed in Reference Documentation |
| Installation in Concrete | Yes |
| Minimum Bending Radius | 7.5 x D, Fixed Installation |
| Specified Installation Tensile Load Range | 300–11500 N |
Temperature Characteristics
| Condition | Minimum Temperature | Maximum Temperature |
|---|---|---|
| Fixed Cable | -30°C | +70°C |
| Cable During Movement | -20°C | +50°C |
Temperature values refer to the permitted outer cable temperature.
Minimum Bending Radius – Fixed Installation
| Configuration | Approx. Outer Diameter (mm) | Calculated Minimum Bending Radius – 7.5 x D (mm) |
|---|---|---|
| Conductor Diameter 0.6 mm | ||
| 2x2x0.6 | 9 | 67.5 |
| 4x2x0.6 | 11 | 82.5 |
| 6x2x0.6 | 12 | 90 |
| 10x2x0.6 | 13.5 | 101.25 |
| 20x2x0.6 | 16 | 120 |
| 30x2x0.6 | 18 | 135 |
| 40x2x0.6 | 20 | 150 |
| 50x2x0.6 | 21 | 157.5 |
| 70x2x0.6 | 25 | 187.5 |
| 100x2x0.6 | 28 | 210 |
| 150x2x0.6 | 33 | 247.5 |
| 200x2x0.6 | 38 | 285 |
| 250x2x0.6 | 41.5 | 311.25 |
| 300x2x0.6 | 44.5 | 333.75 |
| 500x2x0.6 | 56 | 420 |
| Conductor Diameter 0.8 mm | ||
| 2x2x0.8 | 9 | 67.5 |
| 4x2x0.8 | 12 | 90 |
| 6x2x0.8 | 13 | 97.5 |
| 8x2x0.8 | 14 | 105 |
| 10x2x0.8 | 15 | 112.5 |
| 12x2x0.8 | 15.2 | 114 |
| 20x2x0.8 | 18.5 | 138.75 |
| 30x2x0.8 | 21 | 157.5 |
| 40x2x0.8 | 23 | 172.5 |
| 50x2x0.8 | 26 | 195 |
| 70x2x0.8 | 29 | 217.5 |
| 100x2x0.8 | 34 | 255 |
| 150x2x0.8 | 40 | 300 |
| 200x2x0.8 | 44 | 330 |
Bending radii are calculated from approximate outer cable diameters using the specified fixed installation factor of 7.5 x D. These values do not establish a permissible dynamic bending radius during cable pulling.
Star-Quad Colour Identification
| Star-Quad Position | Identification Colour |
|---|---|
| 1 | Red |
| 2 | Green |
| 3 | Grey |
| 4 | Yellow |
| 5 | White |
The five star-quads within each bunch follow the continuous colour sequence red, green, grey, yellow and white.
Core Identification Within Each Star-Quad
| Conductor Identification | Ring Marking |
|---|---|
| a-wire 1 | Without Ring |
| b-wire 1 | One Ring, Widely Spaced |
| a-wire 2 | Double Ring, Widely Spaced |
| b-wire 2 | Double Ring, Narrowly Spaced |
Applicable Technical Standards & Material Designations
| Standard / Designation | Reference Application |
|---|---|
| VDE 0816 | Outdoor Telecommunication Cable Construction |
| 2YI1 | Polyethylene Insulation Compound |
| 2YM1 | Polyethylene Outer Sheath Compound |
| Class 1 | Solid Copper Conductor Construction |