UNIMA CABLE | DATA & COMMUNICATION
Cat 6A S/FTP LS0H – Shielded Ethernet Cable
High-performance 500 MHz, 10 Gigabit Ethernet installation cable with individually screened twisted pairs, overall copper braid and halogen-free LS0H-3 outer jacket.
CAT 6AS/FTP500 MHz10 Gbit/sAWG 23/1Dca-s2,d2,a1
Product Overview
Cat 6A S/FTP LS0H-3 is a shielded installation cable designed for structured cabling systems and high-speed Ethernet transmission up to 500 MHz.
Four twisted pairs of solid copper AWG23/1 conductors are individually screened with laminated aluminium-polyester foil. An overall tinned copper braid provides additional electromagnetic shielding.
The black LS0H-3 flame-retardant, low-smoke, halogen-free jacket makes the cable suitable for building installations requiring CPR reaction-to-fire classification Dca-s2,d2,a1.
Key Technical Features
500 MHzFrequency
10 Gbit/sData Rate
7.2 mmOuter Diameter
DcaCPR razred
Construction & Technical Properties
Cable Construction
ConductorSolid Copper AWG23/1
Pair Arrangement4 Twisted Pairs
InsulationPolyethylene (PE)
Pair ScreensAl/PET Foil (PiMF)
Overall ScreenTinned Copper Braid, 30%
Outer JacketLS0H-3, Black
Electrical & Mechanical Data
FrequencyUp to 500 MHz
Data Transmission10 Gbit/s
Loop Resistance165 Ω/km
Insulation Resistance> 5000 MΩ/km
Operating Temperature-20°C to +60°C
Installation Temperature0°C to +50°C
Static Bending Radius3 × Outer Diameter
Dynamic Bending Radius8 × Outer Diameter
Maximum Tensile Force113 N
Typical Applications
10 Gigabit Ethernet
Structured Building Cabling
Data Centers & Server Rooms
Commercial Network Infrastructure
Industrial Data Networks
High-Speed LAN Connections
Applicable Standards
IEC 61156-5 – Symmetrical pair cables for digital communication.
EN 50288 – Multi-element metallic cables for analogue and digital communication.
EN 50575 – CPR reaction-to-fire requirements.
IEC 61034-1/2 – Smoke density.
IEC 60754-1/2 – Halogen and acidity testing.
IEC 60332-3-24 – Flame propagation.
EN 50288 – Multi-element metallic cables for analogue and digital communication.
EN 50575 – CPR reaction-to-fire requirements.
IEC 61034-1/2 – Smoke density.
IEC 60754-1/2 – Halogen and acidity testing.
IEC 60332-3-24 – Flame propagation.
Installation note: This is a communication cable, not a mains power cable. Operating voltage is below 72 V DC and below 50 V AC. Observe the specified installation temperature, bend radius and tensile-force limits.
Technical Data & Cable Dimensions
Cat 6A S/FTP | 4 × 2 × AWG23/1 | 500 MHz | LS0H-3
500 MHzBandwidth
10 Gbit/sData Rate
49 kg/kmCable Weight
24 kg/kmCopper Weight
Cable Configuration
| Configuration | Conductor | Jacket | Outer Ø (mm) | Copper (kg/km) | Cable (kg/km) | CPR |
|---|---|---|---|---|---|---|
| 4 × 2 × AWG23/1 | Solid Copper | Black LS0H-3 | 7.2 | 24 | 49 | Dca-s2,d2,a1 |
Transmission Performance – IEC 61156-5 Reference
| MHz | Attenuation dB/100m | NEXT dB/100m | PS NEXT dB/100m | ACR-F dB/100m | PS ACR-F dB/100m | ACR-N dB/100m |
|---|---|---|---|---|---|---|
| 1 | 2.1 | 75.3 | 72.3 | 68 | 65 | 73.2 |
| 10 | 5.9 | 60.3 | 57.3 | 48 | 45 | 54.4 |
| 16 | 7.5 | 57.2 | 54.2 | 43.9 | 40.9 | 49.8 |
| 20 | 8.4 | 55.8 | 52.8 | 42 | 39 | 47.4 |
| 31.25 | 10.5 | 52.9 | 49.9 | 38.1 | 35.1 | 42.4 |
| 62.5 | 15 | 48.4 | 45.4 | 32.1 | 29.1 | 33.4 |
| 100 | 19.1 | 45.3 | 42.3 | 28 | 25 | 26.2 |
| 250 | 31.1 | 39.3 | 36.3 | 20 | 17 | 8.3 |
| 500 | 45.3 | 34.8 | 31.8 | 14 | 11 | -10.4 |
Showing 9 of 9 frequencies
Typical Manufacturer Performance
| MHz | Attenuation dB/100m | NEXT dB/100m | PS NEXT dB/100m | ACR-F dB/100m | PS ACR-F dB/100m | ACR-N dB/100m |
|---|---|---|---|---|---|---|
| 1 | 1.8 | >100 | 98 | 93 | 90 | 98.2 |
| 10 | 5.3 | >100 | 98 | 93 | 90 | 94.7 |
| 16 | 6.8 | >100 | 98 | 93 | 90 | 93.2 |
| 20 | 7.6 | >100 | 98 | 93 | 90 | 92.4 |
| 31.25 | 9.6 | >100 | 98 | 90 | 87 | 90.4 |
| 62.5 | 13.6 | 97 | 95 | 86 | 83 | 83.4 |
| 100 | 17.3 | 95 | 93 | 83 | 80 | 77.7 |
| 250 | 27.7 | 90 | 88 | 70 | 67 | 62.3 |
| 500 | 41.9 | 83 | 81 | 57 | 54 | 41.1 |
Technical notes: The first table shows IEC 61156-5 reference values reproduced from the source datasheet. The second shows typical manufacturer values for information only. Values are not interchangeable. Approximate cable diameter 7.2 mm.