Bare copper wire 

Potraži kabel

Select a cable or enter another designation.


BARE COPPER STRANDED WIRE · BARE CONDUCTORS

Bare Copper Stranded Wire

Bare Copper Stranded Wire is an uninsulated copper conductor manufactured from seven or more copper wires concentrically stranded in layers.

Designed for earthing, equipotential bonding, electrical connections in distribution networks and overhead power lines. Available in nominal cross-sections from 10 to 500 mm², with different strand constructions depending on size.

Copper Conductor
10–500 mm² Cross-Sections
7–61 Strand Count
DIN 48201 Standard
Uninsulated Construction
01

Construction

BARE COPPER / CONCENTRIC STRANDING

1
Materijal vodiča

Uninsulated copper wires.

2
Stranding

Copper wires concentrically stranded in layers.

3
Number of Wires

7, 19, 37 or 61 wires, depending on cross-section.

4
Cross-Sections

Nominal sizes from 10 to 500 mm².

5
Insulation

None – bare conductor without insulation.

6
Outer Sheath

None – uninsulated conductor construction.

02

Technical Data

Conductor characteristics

Materijal vodiča Bare Copper
Construction Concentric Stranded
Nominal Cross-Section 10–500 mm²
Number of Strands 7 / 19 / 37 / 61
Conductor Resistance Specified at 20°C
Outer Diameter 4.1–29.1 mm
Nominal Weight 90–4,479 kg/km
Radni napon Not Applicable
Insulation / Sheath None
CPR Classification Not Applicable
03

Standardi

Applicable conductor standards

DIN 48201 Requirements for stranded conductors.
IEC 60228 Conductor characteristics and requirements.
04

Primjene

Electrical connections and earthing systems

Earthing Systems Grounding and earthing connections.
Equipotential Bonding Electrical bonding of metallic components.
Distribution Networks Electrical connections in distribution systems.
Overhead Power Lines Applications in overhead electrical networks.
Flexible Connections Stranded conductor connections where specified.
Electrical Infrastructure Uninsulated copper conductor applications.
BARE COPPER STRANDED WIRE · CU Uninsulated concentric stranded copper conductor. Available in multiple constructions and nominal sizes from 10 to 500 mm². Electrical resistance, dimensions and weights depend on conductor size. Not intended for permanent installation in occupied rooms as specified in the source technical documentation. Availability and packaging are subject to confirmation.
BARE COPPER STRANDED WIRE · TECHNICAL DIMENSIONS

Bare Copper Stranded Wire – Sizes & Technical Data

Technical specifications for all 17 conductor constructions, including nominal cross-sections, stranding, electrical resistance, tensile force and conductor weight.

10–500 mm² Nominal Sizes
7 / 19 / 37 / 61 Strand Counts
DIN 48201 Standard
17 Constructions

Technical Size Table

17 constructions
17 constructions
Nominal Size
mm²
Actual Section
mm²
Stranding
n × mm
Outer Ø
mm
Permissible Tensile Force
kN
Max. Resistance
Ω/km at 20°C
Nominal Weight
kg/km
1010.027x1.354.14.021.807290
1615.897x1.75.16.371.1385142
2524.257x2.16.39.720.746217
3534.367x2.57.513.770.5265308
5049.487x3.09.019.840.3656443
5048.3519x1.89.019.380.3759433
7065.8119x2.110.526.380.2762590
9593.2719x2.512.537.390.1949836
9593.1137x1.7912.537.390.1949834
120116.9919x2.814.046.900.15541048
120117.4037x2.0114.146.900.15541052
150147.1137x2.2515.858.980.12381318
185181.5237x2.517.572.810.10031627
240242.5461x2.2520.397.230.07532173
300299.4361x2.522.5120.040.0612683
400400.1461x2.8926.0160.420.04563585
500499.8361x3.2329.1200.380.03654479
Technical Notes

Actual conductor section and stranding construction vary according to nominal size. Resistance values represent maximum DC resistance at 20°C. Weights are nominal values and may vary within manufacturing tolerances. Tensile force values are taken from the source technical data. Bare conductors have no insulation or outer sheath.

Technical Documentation

Technical Data Sheet

EU declaration of conformity

Core Identification

UNIMA CABLE

Bare copper wire  Cable Calculator

Calculate cable weight, copper content and approximate cable length.

m
Cable Weight 0 kg
Cable Length 0 m
Copper Content 0 kg
Copper Share 0 %
Cable weight: 0 kg/km
Copper: 0 kg/km
Approximate values based on technical cable data. Actual values may vary due to manufacturing tolerances.