UNIMA CABLE | LOW VOLTAGE POWER CABLES

FG16M16 0.6/1 kV – Flexible Copper Power Cable

Single-core power cable with flexible Class 5 copper conductor, G16 rubber insulation and green M16 low-smoke, halogen-free sheath. CPR classification Cca-s1,d1,a1.

0.6/1 kV Copper Class 5 G16 Insulation LSZH M16 Sheath Green Sheath Cca-s1,d1,a1

Product Overview

FG16M16 is a 0.6/1 kV power cable featuring a flexible copper conductor according to EN 60228 Class 5, G16 rubber-compound insulation and a low-smoke, halogen-free M16 outer sheath.

It is particularly suitable for locations with increased fire risk or high occupancy, where limiting smoke and corrosive gas emissions is important. Typical environments include offices, schools, supermarkets, cinemas and theatres.

The cable is suitable for indoor and outdoor installation, including wet environments, mounting on walls or metal structures, installation in conduits, free-air routing and underground laying.

Key Technical Features

0.6/1 kVRadni napon
Class 5Copper Conductor
+90°CMax. Working Temperature
CcaCPR razred

Construction & Technical Properties

Cable Construction

ConductorFlexible Copper, Class 5
Conductor StandardEN 60228
InsulationG16 Rubber Compound
Insulation ColourCrna
Outer SheathLSZH / HFFR, M16
Sheath ColourGreen
Core ConfigurationSingle-Core
Size Range1x10 to 1x300 mm²

Electrical & Mechanical Data

Radni napon0.6/1 kV
Test Voltage4 kV
Min. Installation Temp.0°C
Min. Working Temp.-15°C
Max. Working Temp.+90°C
Short-Circuit Temp.+250°C
Min. Bending Radius4 × D
Max. Tensile Stress50 N/mm²
CPR ClassificationCca-s1,d1,a1

Typical Applications

Commercial Buildings & Offices
Schools & Public Facilities
Shopping Centres & Supermarkets
Cinemas & Theatres
Indoor & Outdoor Installations
Underground & Conduit Installations

Applicable Standards

CEI 20-13 – Power cable reference standard.
IEC 60502-1 – Extruded-insulation power cables.
EN 60228 – Class 5 copper conductors.
HD 308 S2 – Core identification.
CPR Cca-s1,d1,a1 – Reaction-to-fire classification stated in the reference technical sheet.
Technical Note: Dimensions, electrical ratings and weights depend on cable size. Current ratings in the reference documentation are given for underground installation in pipe at 20°C and installation in pipe in air at 30°C. Verify project-specific installation conditions, correction factors and the Declaration of Performance (DoP) for the cable supplied.
UNIMA CABLE | TECHNICAL DIMENSIONS

FG16M16 – Cable Dimensions & Weight Calculator

Explore 12 single-core cable sizes, electrical characteristics and reference weights. Enter the required length for any size to calculate its total cable weight.

Available Cable Sizes

Size (mm²) Max. Resistance at 20°C (Ω/km) Current, Ground Pipe 20°C (A) Current, Air Pipe 30°C (A) Outer Diameter (mm) Cable Weight (kg/km) Length (m) Total Weight (kg)
1x101.91059668.41450
1x161.21077889.32000
1x250.78010011711.02950
1x350.55412114412.13900
1x500.38615017513.95250
1x700.27218422215.47200
1x950.20621726917.39400
1x1200.16125931218.911650
1x1500.12928735521.214700
1x1850.10632341724.418900
1x2400.080137949027.523100
1x3000.0641429–30.529000
12 cable sizes | 1x10 to 1x300 mm²

Total Cable Weight

Combined weight of all entered cable lengths
0 kg
Technical Note: Values are reference data. Current ratings are specified for installation in underground pipe at 20°C and pipe in air at 30°C, under the reference conditions stated in the technical documentation. The 1x300 mm² air current rating is not specified. Copper weight is not separately provided in the source and is therefore not shown. Total weights exclude packaging and cable drums.

Technical Documentation

Technical Data Sheet

EU declaration of conformity

Core Identification

Send Us email - RFQ


KOLEKCIJA KABELA UNIMA

Istražite našu ponudu kabela

Otkrijte vrste kabela, tehničke specifikacije i rješenja za svoje projekte.

80 Cable Types Available