A-D(ZN)2Y

Potraži kabel

Select a cable or enter another designation.


UNIMA CABLE | FIBRE OPTIC CABLES

A-D(ZN)2Y (HT) – Optical Fibre Micro Cable

Compact metal-free singlemode optical fibre micro cable with a central loose tube, aramid strength members and HDPE outer sheath, designed for installation by blowing into microducts.

Singlemode G.657.A1 / G.652.D 4–24 Fibres HDPE Sheath Metal-Free Aramid Reinforcement Microduct Installation IEC 60794-5

Product Overview

A-D(ZN)2Y (HT) is a compact optical fibre micro cable designed for installation by blowing into microduct systems.

The cable contains a central loose tube accommodating up to 24 optical fibres, filled with a thixotropic compound. Aramid strength members provide mechanical reinforcement, while the HDPE outer sheath protects the cable during installation and operation.

The entirely metal-free construction makes the cable suitable for optical communication networks requiring lightweight and compact microduct solutions.

The reference configurations include 4, 6, 12 and 24 singlemode optical fibres with G.657.A1 / G.652.D designations.

Key Technical Features

4–24Optical Fibres
2.4–2.9 mmOuter Diameter
7–9 kg/kmCable Weight
100 NInstallation Tensile Load

Construction & Technical Properties

Cable Construction

Fibre TypeSinglemode
Fibre DesignationG.657.A1 / G.652.D
Number of Fibres4–24
Core ConstructionCentral Loose Tube
Tube FillingThixotropic Compound
Strength MembersAramid
Outer SheathHDPE
Sheath ColourCrna
Sheath Thickness0.35 mm
Metal-FreeYes
Meter MarkingYes

Mechanical & Thermal Data

Installation MethodMicroduct Blowing
Microduct Dimensions7/4 or 10/6 mm
Max. Installation Tensile Load100 N
Crush Resistance300 N
Bending Radius Under Tension20 × D
Bending Radius Without Tension10 × D
Operating Temperature-20°C to +70°C
Installation Temperature-5°C to +50°C
Storage Temperature-20°C to +70°C
Transport Temperature-20°C to +70°C
Printing MethodInkjet

Reference Optical Characteristics

ITU-T G.657.A1 Singlemode Fibre

Attenuation at 1310 nm≤0.36 dB/km
Attenuation at 1550 nm≤0.22 dB/km
Mode Field Diameter at 1310 nm9.2 ± 0.4 µm
Mode Field Diameter at 1550 nm10.4 ± 0.8 µm
Zero Dispersion Wavelength1300–1324 nm
Zero Dispersion Slope≤0.092 ps/(nm²·km)
Polarisation Mode Dispersion≤0.1 ps/√km
Cut-Off Wavelength≤1260 nm
Macrobending Loss (10 Turns, Ø30 mm)≤0.25 dB at 1550 nm
Macrobending Loss (1 Turn, Ø20 mm)≤0.75 dB at 1550 nm
Fibre Outer Diameter200 ± 10 / 250 ± 10 µm
Cladding Diameter125 ± 1.0 µm
Core/Cladding Concentricity Error≤0.6 µm
Cladding Non-Circularity≤1.0%

Typical Applications

Optical Microduct Networks
Fibre Optic Telecommunications
FTTH and FTTx Networks
Compact Optical Distribution Networks
Blown Fibre Cable Installations
Single Cable Microduct Installation

Applicable Standards

IEC 60793-1 – Optical fibre measurement methods and test procedures.
IEC 60793-2 – Optical fibre product specifications.
IEC 60794-5 – Microduct cabling for installation by blowing.
ITU-T G.657.A1 – Reference bend-insensitive singlemode fibre specification.
ITU-T G.652.D – Singlemode fibre designation listed for the reference configurations.
Technical Note: Optical characteristics are reference values listed for the G.657.A1 fibre specification. Actual fibre properties, microduct compatibility, mechanical performance and cable dimensions must be confirmed for the selected configuration. CPR classification is not specified.
UNIMA CABLE | TECHNICAL DIMENSIONS

A-D(ZN)2Y (HT) – Cable Sizes & Technical Data

Five reference singlemode optical micro cable configurations with fibre count, sheath thickness, outer diameter, mechanical characteristics and net cable weight per kilometre.

5Reference Configurations
4–24Optical Fibres
2.4–2.9 mmOuter Diameter
7–9 kg/kmCable Weight

Available Cable Sizes

Configuration Fibre Count Fibre Type Sheath Thickness (mm) Outer Diameter (mm) Installation Tensile Load (N) Crush Resistance (N) Cable Weight (kg/km)
A-D(ZN)2Y (HT) – Singlemode Optical Micro Cable
1x4 4 G.657.A1 / G.652.D 0.35 2.5 100 300 7
1x6 6 G.657.A1 / G.652.D 0.35 2.5 100 300 7
1x12 – OD 2.4 mm 12 G.657.A1 / G.652.D 0.35 2.4 100 300 7
1x12 – 200 µm 12 G.657.A1 / G.652.D 0.35 2.5 100 300 7
1x24 – 200 µm 24 G.657.A1 / G.652.D 0.35 2.9 100 300 9

Optical Fibre Colour Identification

1
Red
2
Green
3
Blue
4
Yellow
5
White
6
Grey
7
Brown
8
Violet
9
Cyan
10
Crna
11
Orange
12
Pink
13
Red / Marked
14
Green / Marked
15
Blue / Marked
16
Yellow / Marked
17
White / Marked
18
Grey / Marked
19
Brown / Marked
20
Violet / Marked
21
Cyan / Marked
22
Natural / Marked
23
Orange / Marked
24
Pink / Marked
Technical Note: Outer diameters are approximate. Cable weights are expressed in kg/km and exclude drums and packaging. The cable is entirely metal-free. The listed configurations are recommended for 7/4 mm microducts. General cable application also includes 10/6 mm microduct systems. Compatibility and fibre colour identification must be confirmed for the supplied product.

Technical Documentation

Technical Data Sheet

EU declaration of conformity

Core Identification

Send Us email - RFQ


KOLEKCIJA KABELA UNIMA

Istražite našu ponudu kabela

Otkrijte vrste kabela, tehničke specifikacije i rješenja za svoje projekte.

80 Cable Types Available