FG16R16 Flexible Power Cable 0.6/1 kV


Tehnički podaci

  • FG16R16
  • Tip kabela
  • Industrial, Construction & Power Distribution
  • Područje primjene
  • CEI 20-13 / IEC 60502-1
  • Standard

Detaljnije

  • Izolacijski materijal G16 Rubber
  • Pakiranje Wooden Drums
  • Dostupnost Stock
  • Conductor Class Class 5 Flexible
  • Insulation G16 Rubber
  • Outer Sheath R16 PVC
  • Max. Operating Temperature 90°C
  • Max. Short-Circuit Temperature 250°C
  • Minimum Laying Temperature -15°C
  • Minimum Bending Radius 6 × D
  • Materijal vodiča Copper
  • Grupa kabela Energetski kablovi 1 - 30 kV
  • Izolacijski materijal G16 Rubber
  • Radni napon 0.6/1 kV
  • CPR razred Cca-s3,d1,a3
  • Standard CEI 20-13 / IEC 60502-1
FG16R16 · FLEXIBLE POWER CABLE

FG16R16 Flexible Copper Power Cable

FG16R16 is a 0.6/1 kV power cable with flexible Class 5 copper conductor, G16 rubber insulation and R16 PVC outer sheath. It is designed for reliable energy supply in industrial, commercial and construction applications.

Suitable for fixed wiring indoors and outdoors, including wet environments, as well as direct and indirect underground installation. FG16R16 can also be installed in open air, on walls, metal structures, cable trays, pipes and similar cable support systems.

0.6/1 kV Radni napon
Class 5 Cu Conductor
G16 Rubber Insulation
R16 PVC Outer Sheath
Cca-s3,d1,a3 CPR razred
01

Construction

Cu / G16 Rubber / R16 PVC

1
Conductor

Flexible copper conductor, Class 5 according to EN 60228

2
Insulation

G16 quality rubber compound

3
Outer Sheath

R16 quality PVC compound

4
Sheath Colour

Grey · other colours available on request

02

Technical Data

Electrical, thermal and installation characteristics

Rated Voltage U₀/U 0.6/1 kV
Test Voltage 4 kV
CPR Classification Cca-s3,d1,a3
Maximum Conductor Temperature 90°C
Maximum Short-Circuit Temperature 250°C
Minimum Laying Temperature -15°C
Minimum Bending Radius 6 × D
Conductor Class Class 5
03

Standards

Applicable cable and conductor standards

CEI 20-13 Power cable reference standard
IEC 60502-1 Power cables with extruded insulation
EN 60228 Class 5 copper conductor
HD 308 S2 Core identification
04

Applications

Flexible power distribution for demanding installations

Industrial Installations Suitable for energy supply and fixed power distribution in industrial installations.
Construction Suitable for building sites and construction industry power installations.
Indoor & Outdoor Suitable for fixed wiring indoors and outdoors, including wet environments.
Underground Installation Suitable for direct and indirect underground cable installation.
Cable Trays & Structures Suitable for installation on walls, metal structures, cable trays, pipes and cable support systems.
Fire-Risk Environments CPR Cca-s3,d1,a3 cable suitable for bundle installations in environments at risk of fire.
FG16R16 · 0.6/1 kV · Cca-s3,d1,a3 Available in a wide range of single-core conductor cross-sections. Cable dimensions, weight and permissible current depend on the selected conductor size and installation conditions.
FG16R16 · 0.6/1 kV

Dimensions & Technical Data

Standard single-core FG16R16 cable sizes with conductor resistance, insulation and sheath thickness, current carrying capacity, outer diameter and approximate cable weight.

01

Single Core

FG16R16 · Flexible Class 5 copper conductor · G16 insulation · R16 sheath

Cross Section
mm²
Resistance 20°C
Ω/km
Insulation
mm
Sheath
mm
In Air 30°C
A
Pipe in Air 30°C
A
Buried K=1
A
Buried K=1.5
A
Buried Pipe K=1
A
Buried Pipe K=1.5
A
Outer Ø
mm
Cable Weight
kg/km
1×1.5 13.3 0.7 1.4 24 20 26 24 23 21 8.2 55
1×2.5 7.98 0.7 1.4 33 28 34 31 29 27 8.7 66
1×4 4.95 0.7 1.4 45 37 43 40 38 35 9.3 84
1×6 3.30 0.7 1.4 58 48 55 51 48 44 9.9 110
1×10 1.91 0.7 1.4 80 66 73 68 64 59 10.9 150
1×16 1.21 0.7 1.4 107 88 96 89 83 77 11.4 220
1×25 0.780 0.9 1.4 141 117 124 115 108 100 13.2 310
1×35 0.554 0.9 1.4 176 144 150 139 131 121 14.6 410
1×50 0.386 1.0 1.4 216 175 186 173 162 150 16.4 560
1×70 0.272 1.1 1.4 279 222 229 212 199 184 18.3 760
1×95 0.206 1.1 1.5 342 269 270 250 234 217 20.4 960
1×120 0.161 1.2 1.5 400 312 312 289 271 251 22.4 1210
1×150 0.129 1.4 1.6 464 355 356 330 310 287 24.8 1480
1×185 0.106 1.6 1.6 533 417 401 371 349 323 27.2 1790
1×240 0.0801 1.7 1.7 634 490 471 436 409 279 30.4 2320
1×300 0.0641 1.8 1.8 736 – 533 493 463 429 33.0 2840
1×400 0.0486 2.0 1.9 868 – 621 575 540 500 37.7 3735
1×500 0.0384 2.2 2.1 998 – 705 650 610 560 43.6 4660
Need another configuration? Additional FG16R16 cable configurations may be available on request. Contact UNIMA CABLE with the required conductor size, quantity and project specification.
Technical note Permissible current ratings are based on a three-phase circuit. Buried cable values are based on a laying depth of 0.8 m. K = 1 corresponds to ground thermal resistivity of 1.0 K·m/W and K = 1.5 corresponds to 1.5 K·m/W. Cable dimensions and weights are approximate.

Technical Documentation

Technical Data Sheet

EU declaration of conformity

Core Identification

Maximum 2 cross-sections per Data Sheet. 1 selected
UNIMA CABLE

FG16R16 Flexible Power Cable 0.6/1 kV Cable Calculator

Calculate cable weight, copper content and approximate cable length.

m
Cable Weight 0 kg
Cable Length 0 m
Copper Content 0 kg
Copper Share 0 %
Cable weight: 0 kg/km
Copper: 0 kg/km
Approximate values based on technical cable data. Actual values may vary due to manufacturing tolerances.
distributor wire and cable 35kv sourcing
Unima d.d.

Zašto odabrati Unima Cable?

B2B partner for cable distribution across Europe and global industrial projects

Years of Experience
0 +
Fast Delivery
0 +h
Technical Documentation Files
0 +
Markets Served
0 +