JE-H(St)H FE180/E30-E90 – Fire Resistant Signal Cable


Tehnički podaci

  • JE-H(St)H FE180/E30-E90
  • Tip kabela
  • Fire Alarm & Fire Signalisation Systems
  • Područje primjene
  • VDE 0815 / DIN 4102-12
  • Standard

Detaljnije

  • Izolacijski materijal FRNC Compound HI1
  • Pakiranje Coils / Wooden Drums
  • Dostupnost Stock
  • Cable Function Fire Alarm & Signal Transmission
  • Fire Resistance FE180
  • Circuit Integrity E30-E90 (Certified Installation System)
  • Operating Voltage 225 V Peak
  • Materijal vodiča Bare Copper
  • Conductor Construction Class 1 Solid, 0.8 mm
  • Screening Foil Screen with Drain Wire
  • Outer Sheath Halogen-Free FRNC HM2
  • Sheath Colour Red
  • Materijal vodiča Bare Copper, Class 1 Solid
  • Grupa kabela Fire Performance Cables
  • Izolacijski materijal FRNC Compound HI1
  • Radni napon 225 V Peak Operating Voltage
  • CPR razred According to Manufacturer DoP
  • Standard VDE 0815 / DIN 4102-12
UNIMA CABLE | Fire Performance Solutions

JE-H(St)H FE180/E30–E90

JE-H(St)H FE180/E30–E90 is a halogen-free, screened communication and fire signalisation cable designed for reliable signal transmission between electronic devices and within fire safety systems.

Featuring solid copper conductors, foil screening, FRNC insulation and a red outer sheath, the cable is intended for fixed installation in dry and damp indoor areas on certified carrier systems.

It provides FE180 fire resistance and E30–E90 circuit integrity when installed as part of an appropriately tested cable installation system in accordance with DIN 4102-12.

FE180 Fire Resistance
E30–E90 Circuit Integrity
225 V Peak Operating Voltage
120 nF/km Maximum Operating Capacitance
FRNC Halogen-Free Construction
Cable Design

Construction

01

Solid Copper Conductors

Bare copper, Class 1 solid conductors, with a nominal conductor diameter of 0.8 mm.

02

FRNC Core Insulation

Fire-resistant, halogen-free FRNC insulation compound, type HI1.

03

Paired Core Arrangement

Cores twisted into pairs. Four pairs are laid into sub-units, with sub-units stranded in layers. Two-pair versions are stranded as a star-quad.

04

Foil Screen & Drain Wire

Foil screening with an integrated drain wire for screened signal cable construction.

05

Outer Sheath

Halogen-free, flame-retardant FRNC compound, type HM2, with red outer sheath.

06

Core Identification

Colour-coded conductors according to VDE 0815. The cable is intended for fire signalisation systems.

Engineering Specifications

Technical Characteristics

Cable designationJE-H(St)H FE180/E30–E90
Product standardVDE 0815
Peak operating voltage225 V
Maximum operating capacitance120 nF/km
Conductor materialBare copper
Conductor constructionClass 1, solid
Conductor diameter0.8 mm
Core insulationFRNC compound HI1
ScreenFoil
Drain wireYes
Outer sheathFRNC compound HM2
Sheath colourRed
Fixed installation temperature-5°C to +50°C
Minimum bending radius7.5 × outer diameter
Fire resistanceFE180
Circuit integrityE30–E90 with tested cable systems
Core identificationVDE 0815
CPR classificationAccording to applicable manufacturer DoP
Where It Is Used

Typical Applications

Fire alarm and fire signalisation systems
Signal transmission between electronic devices
Process control communication systems
Public buildings with high fire safety requirements
Buildings with high occupancy
Facilities with valuable technical equipment
Fixed installations in dry and damp indoor areas
Certified cable support systems requiring E30/E90
Fire Safety

Fire Performance & Standards

VDE 0815 FE180 DIN 4102-12 | E30–E90 IEC 60332-3-24 IEC 61034 IEC 60754
Important installation information: E30/E90 circuit integrity applies to the complete appropriately tested cable installation system, including certified cable supports and fixings. The cable is designed for fixed installation in dry and damp indoor areas. Verify the applicable test certificates and Declaration of Performance before specifying the cable for a project.

Technical Data & Cable Dimensions

JE-H(St)H FE180/E30–E90 | Fire Resistant Signal Cable | VDE 0815

10 Cable Configurations
0.8 mm Conductor Diameter
225 V Peak Operating Voltage
FE180 Fire Resistance
Cable Dimensions & Weights
Configuration Conductor Ø
(mm)
Outer Ø
(mm)
Copper Weight
(kg/km)
Cable Weight
(kg/km)
Source: Klaus Faber AG | JE-H(St)H FE180/E30–E90
Technical information: Conductor and approximate outer diameters are expressed in millimetres. Copper and cable weights are expressed in kg/km. Values refer to manufacturer reference data.

Fire safety: FE180 describes fire resistance of the cable. E30–E90 circuit integrity applies to the complete tested installation system, including appropriate cable supports and fixings, in accordance with DIN 4102-12.

Technical Documentation

Technical Data Sheet

EU declaration of conformity

Core Identification

Maximum 2 cross-sections per Data Sheet. 1 selected
UNIMA CABLE

JE-H(St)H FE180/E30-E90 Cable Calculator

Fire Resistant Signal Cable

Calculate cable weight, copper content and approximate cable length.

m
Cable Weight 0 kg
Cable Length 0 m
Copper Content 0 kg
Copper Share 0 %
Cable weight: 0 kg/km
Copper: 0 kg/km
Approximate values based on technical cable data. Actual values may vary due to manufacturing tolerances.
distributor wire and cable 35kv sourcing
Unima d.d.

Zašto odabrati Unima Cable?

B2B partner for cable distribution across Europe and global industrial projects

Years of Experience
0 +
Fast Delivery
0 +h
Technical Documentation Files
0 +
Markets Served
0 +