Potraži kabel

Select a cable or enter another designation.


UNIMA CABLE | HALOGEN-FREE CONTROL CABLES

HSLH FRNC – Halogen-Free Control Cable 300/500 V

Flexible halogen-free multicore control and signal cable with Class 5 copper conductors, cross-linked polyolefin copolymer insulation and a grey halogen-free outer sheath. Designed for indoor fixed and movable installations requiring improved fire performance.

300/500 V 0.75–25 mm² 2–34 Cores Class 5 Copper FRNC Halogen-Free LSZH Cross-Linked Polyolefin JZ / OZ IEC 60332-3 Category C

Product Overview

HSLH FRNC is a flexible halogen-free control and signal cable with improved behaviour under fire conditions.

The cable incorporates fine-stranded bare copper conductors according to DIN EN 60228 Class 5, providing flexibility for installation and equipment connections.

Both the individual core insulation and the grey outer sheath are manufactured from halogen-free, cross-linked polyolefin copolymer compounds.

The FRNC designation refers to flame-retardant and non-corrosive cable characteristics. The construction is intended to limit flame propagation, smoke generation and corrosive combustion gases.

HSLH FRNC is intended for installation in dry, damp and wet indoor environments. It is suitable for fixed and movable installations without excessive tensile stress or forced bending.

The reference product range includes conductor cross-sections from 0.75 to 25 mm² and configurations from 2 to 34 cores, depending on the selected cross-section.

Key Technical Features

300/500 VRadni napon
0.75–25 mm²Conductor Range
Class 5Flexible Copper
+70°CMaximum Specified Temperature

Cable Variants

HSLH-JZ FRNC

With Protective Earth Conductor

One green/yellow protective earth conductor and remaining black cores with numerical identification.

Suitable for control circuits and equipment connections requiring a protective earth conductor.

HSLH-OZ FRNC

Without Protective Earth Conductor

All cores are black with numerical identification, without a green/yellow protective earth conductor.

Suitable for control and signal circuits where a protective earth conductor is not required within the cable.

Construction & Technical Properties

Cable Construction

Materijal vodičaBare Copper
Conductor ConstructionFine-Stranded, Flexible
Conductor ClassClass 5
Conductor StandardDIN EN 60228
Conductor Cross-Section0.75–25 mm²
Number of Cores2–34
Core InsulationHalogen-Free Cross-Linked Polyolefin Copolymer
Core Identification JZBlack Numbered Cores and Green/Yellow PE
Core Identification OZBlack Numbered Cores
Overall ScreenNone
ArmourNone
Outer SheathHalogen-Free Cross-Linked Polyolefin Copolymer
Sheath ColourGrey

Electrical & Mechanical Data

Rated Voltage U0/U300/500 V
Test Voltage2000 V AC
Temperature During Bending-5°C to +70°C
Fixed Installation Temperature-30°C to +70°C
Short-Circuit Temperature+150°C
Maximum Short-Circuit Duration5 Seconds
Minimum Bending Radius During Bending15 x Cable Diameter
Halogen-Free ConstructionYes
Fire PerformanceFRNC
Flame PropagationIEC 60332-3 Category C
Outdoor InstallationNot Permitted
Approx. Outer Diameter5.4–23.5 mm
Approx. Cable Weight47–1620 kg/km

Fire Performance & Halogen-Free Properties

Flame Retardancy

HSLH FRNC is designed to provide improved flame propagation performance compared with conventional cable constructions without equivalent fire performance characteristics.

The reference documentation specifies EN 50266-2-4, EN 60332-1 and IEC 60332-3 Category C.

Low Smoke & Halogen-Free Construction

The halogen-free cross-linked polyolefin insulation and outer sheath are intended to reduce smoke and corrosive gas generation under fire conditions.

The reference construction is adapted to DIN EN 50267-2-2 and DIN EN 50268-2.

Typical Applications

Industrial Control Systems
Industrial Automation
Signal Transmission
Measurement and Monitoring Systems
Commercial Building Automation
Indoor Equipment Connections
Data Center Control Systems
Control Cabinet Connections
Public Building Control Systems
Indoor Technical Installations
Industrial Production Facilities
Installations Requiring Halogen-Free Cables

Installation Conditions

HSLH FRNC is suitable for installation in dry, damp and wet indoor environments.

The cable can be used in fixed and movable installations, provided that it is not subjected to excessive tensile stress or forced bending.

The specified temperature range during bending is -5°C to +70°C.

For fixed installations, the specified temperature range is -30°C to +70°C.

The minimum bending radius during bending is 15 times the cable outer diameter.

Outdoor installation is not permitted. Suitability for direct burial, permanent immersion, drag chains and continuous-flex applications is not established by the reference documentation.

Applicable Standards

DIN EN 60228, Class 5 – Flexible copper conductor construction.

DIN EN 50266-2-4 – Reference standard for vertical flame propagation of vertically mounted bunched cables, Category C.

DIN EN 50267-2-2 – Reference standard for determining the acidity and conductivity of gases evolved during combustion.

DIN EN 50268-2 – Reference standard for smoke density measurement under defined combustion conditions.

EN 60332-1 – Vertical flame propagation test for a single insulated wire or cable.

IEC 60332-3 Category C – Vertical flame propagation performance of vertically mounted bunched cables.

FRNC and Fire-Resistant Cables

HSLH FRNC is a flame-retardant, halogen-free control cable. Improved fire behaviour does not automatically establish continued electrical circuit operation during a fire.

The reference documentation does not specify FE180, E30, E60, E90 or other circuit integrity classifications.

Where fire-resistant circuit integrity is required, a separately tested and certified cable system must be selected.

Technical Note: Cable dimensions, conductor stranding, copper content and weights depend on the selected configuration. The listed fire performance standards are reproduced from the reference documentation, including legacy standard designations. CPR Euroclass classification, circuit integrity, quantitative smoke density and current-carrying capacity are not specified. Final technical characteristics, current applicable standards and conformity documentation must be confirmed for the supplied product.
UNIMA CABLE | TECHNICAL DIMENSIONS

HSLH FRNC – Cable Sizes & Technical Data

Complete reference range of flexible halogen-free control and signal cables rated 300/500 V, including conductor construction, copper content, approximate cable dimensions, weights, electrical characteristics and installation parameters.

42Reference Configurations
0.75–25 mm²Conductor Cross-Section
2–34Number of Cores
47–1620 kg/kmCable Weight

Available Cable Sizes & Construction Data

Cable Size (mm²) Number of Cores Copper Content (kg/km) Approx. Conductor Stranding Approx. Outer Diameter (mm) Approx. Cable Weight (kg/km)
HSLH FRNC – 0.75 mm²
2x0.75214.424 x 0.215.447
3x0.75321.624 x 0.215.756
4x0.75428.824 x 0.216.269
5x0.75536.024 x 0.216.883
7x0.75750.424 x 0.217.4104
12x0.751286.424 x 0.219.9172
18x0.7518129.624 x 0.2112.4263
25x0.7525180.024 x 0.2114.4352
34x0.7534244.824 x 0.2115.9512
HSLH FRNC – 1 mm²
2x1219.232 x 0.215.755
3x1328.832 x 0.216.067
4x1438.432 x 0.216.683
5x1548.032 x 0.217.2100
7x1767.232 x 0.218.0130
12x112115.232 x 0.2110.6212
18x118172.832 x 0.2112.7314
25x125240.032 x 0.2115.3429
HSLH FRNC – 1.5 mm²
2x1.5228.830 x 0.266.372
3x1.5343.230 x 0.266.788
4x1.5457.630 x 0.267.3110
5x1.5572.030 x 0.268.1135
7x1.57100.830 x 0.268.9174
12x1.512172.830 x 0.2612.0289
18x1.518259.230 x 0.2614.4433
25x1.525360.030 x 0.2617.4596
34x1.534489.630 x 0.2619.6786
HSLH FRNC – 2.5 mm²
2x2.5248.050 x 0.267.6110
3x2.5372.050 x 0.268.1137
4x2.5496.050 x 0.268.9174
5x2.55120.050 x 0.2610.0217
7x2.57168.050 x 0.2612.7306
12x2.512288.050 x 0.2614.9467
HSLH FRNC – 4 mm²
4x44153.656 x 0.3110.8267
5x45192.056 x 0.3112.1331
7x47268.856 x 0.3113.4432
HSLH FRNC – 6 mm²
4x64230.484 x 0.3113.0388
5x65288.084 x 0.3114.5480
HSLH FRNC – 10 mm²
4x104384.080 x 0.4116.2616
5x105480.080 x 0.4118.1766
HSLH FRNC – 16 mm²
4x164614.4128 x 0.4118.9908
5x165768.0128 x 0.4121.21134
HSLH FRNC – 25 mm²
4x254960.0182 x 0.4123.51620

Cable sizes are expressed as the number of cores multiplied by the nominal conductor cross-section in mm². The table uses generic cable size notation. The required JZ or OZ version must be specified when ordering.

Conductor stranding is expressed as the approximate number of individual wires multiplied by their nominal diameter in millimetres. Copper content values are indicative reference figures and must not be interpreted as independently verified recoverable copper mass.

Conductor Construction by Cross-Section

Nominal Cross-Section (mm²) Approx. Conductor Stranding Conductor Class Reference Configurations
0.7524 x 0.21 mmClass 59
132 x 0.21 mmClass 58
1.530 x 0.26 mmClass 59
2.550 x 0.26 mmClass 56
456 x 0.31 mmClass 53
684 x 0.31 mmClass 52
1080 x 0.41 mmClass 52
16128 x 0.41 mmClass 52
25182 x 0.41 mmClass 51

Electrical Characteristics

ParameterReference Value
Rated Voltage U0/U300/500 V
Test Voltage2000 V AC
Materijal vodičaBare Copper
Conductor ConstructionFine-Stranded, Flexible
Conductor ClassClass 5
Conductor StandardDIN EN 60228
Core InsulationHalogen-Free Cross-Linked Polyolefin Copolymer
Overall ScreenNone
Current-Carrying CapacityNot Specified
Conductor ResistanceNot Specified

Temperature Characteristics

Installation / Operating Condition Minimum Temperature Maximum Temperature
During Bending-5°C+70°C
Fixed Installation-30°C+70°C
Short-Circuit ConditionNot Specified+150°C

Maximum short-circuit duration: 5 seconds.

Minimum Cable Bending Radius

Cable Size (mm²) Approx. Outer Diameter (mm) Minimum Radius During Bending 15 x D (mm)
0.75 mm²
2x0.755.481
3x0.755.785.5
4x0.756.293
5x0.756.8102
7x0.757.4111
12x0.759.9148.5
18x0.7512.4186
25x0.7514.4216
34x0.7515.9238.5
1 mm²
2x15.785.5
3x16.090
4x16.699
5x17.2108
7x18.0120
12x110.6159
18x112.7190.5
25x115.3229.5
1.5 mm²
2x1.56.394.5
3x1.56.7100.5
4x1.57.3109.5
5x1.58.1121.5
7x1.58.9133.5
12x1.512.0180
18x1.514.4216
25x1.517.4261
34x1.519.6294
2.5 mm²
2x2.57.6114
3x2.58.1121.5
4x2.58.9133.5
5x2.510.0150
7x2.512.7190.5
12x2.514.9223.5
4 mm²
4x410.8162
5x412.1181.5
7x413.4201
6 mm²
4x613.0195
5x614.5217.5
10 mm²
4x1016.2243
5x1018.1271.5
16 mm²
4x1618.9283.5
5x1621.2318
25 mm²
4x2523.5352.5

Minimum bending radii are calculated using the approximate cable outer diameters and the specified bending factor of 15 x D. A separate bending radius for fixed installation is not specified in the reference documentation.

Cable Construction Layers

Layer Component Material / Construction
1ConductorFine-Stranded Bare Copper, Class 5
2Core InsulationHalogen-Free Cross-Linked Polyolefin Copolymer
3Outer SheathGrey Halogen-Free Cross-Linked Polyolefin Copolymer

Core Identification & Cable Variants

Version Core Identification Protective Earth
HSLH-JZ FRNCBlack Numbered Cores and Green/Yellow CoreYes
HSLH-OZ FRNCBlack Numbered CoresNo

Fire Performance Characteristics

Parameter Reference Standard / Value
Halogen-Free ConstructionYes
Fire Performance DesignationFRNC
Single Cable Flame PropagationEN 60332-1
Bunched Cable Flame PropagationEN 50266-2-4
Bunched Cable Flame CategoryIEC 60332-3 Category C
Combustion Gas Acidity and ConductivityConstruction Adapted to DIN EN 50267-2-2
Smoke DensityConstruction Adapted to DIN EN 50268-2
CPR EuroclassNot Specified
FE180 Circuit IntegrityNot Specified
E30 / E60 / E90 Functional IntegrityNot Specified

Mechanical & Environmental Characteristics

Parameter Reference Value
Outer Sheath MaterialHalogen-Free Cross-Linked Polyolefin Copolymer
Outer Sheath ColourGrey
Dry Indoor EnvironmentsSuitable
Damp Indoor EnvironmentsSuitable
Wet Indoor EnvironmentsSuitable
Fixed InstallationSuitable
Movable InstallationSuitable Without Excessive Tensile Stress or Forced Bending
Outdoor InstallationNot Permitted
Forced BendingNot Permitted
High Tensile StressNot Permitted
Oil ResistanceNot Specified
UV ResistanceNot Specified
Direct BurialNot Specified
Permanent Water ImmersionNot Specified
Continuous-Flex ApplicationsNot Specified

Applicable Standards

Standard Reference Application
DIN EN 60228Flexible Copper Conductors, Class 5
DIN EN 50266-2-4Adapted Construction – Bunched Cable Flame Propagation, Category C
DIN EN 50267-2-2Adapted Construction – Acidity and Conductivity of Combustion Gases
DIN EN 50268-2Adapted Construction – Smoke Density Measurement
EN 60332-1Single Cable Vertical Flame Propagation
IEC 60332-3 Category CBunched Cable Vertical Flame Propagation
Technical Note: All cable dimensions, conductor stranding, copper content and cable weights are indicative reference values. The listed configurations do not constitute a declaration of stock availability. The required JZ or OZ version must be confirmed when ordering. Final technical characteristics and conformity documentation must be confirmed for the supplied product.
Data Verification: The conductor stranding of 182 x 0.41 mm for the 4x25 mm² configuration is reproduced from the reference documentation without modification. Minimum bending radii are calculated values. Legacy fire performance standard designations are retained as published. CPR classification, circuit integrity and compliance with current replacement standards must be confirmed separately.

Technical Documentation

Technical Data Sheet

EU declaration of conformity

Core Identification

Send Us email - RFQ


KOLEKCIJA KABELA UNIMA

Istražite našu ponudu kabela

Otkrijte vrste kabela, tehničke specifikacije i rješenja za svoje projekte.

96 Cable Types Available