MPRXCX / MPRXCX FLEXISHIP – Marine Power & Control Cable 0.6/1 kV
Screened and armoured marine power and control cables with copper conductors, XLPE insulation, bare copper braid and a halogen-free polyolefin outer sheath. Designed for fixed shipboard electrical installations requiring mechanical protection, electromagnetic screening and enhanced fire performance.
Product Overview
MPRXCX is a screened and armoured low-voltage marine cable intended for fixed electrical installations requiring additional mechanical protection and electromagnetic screening.
The cable incorporates stranded bare copper conductors, cross-linked polyethylene (XLPE) insulation, a lapped inner covering and bare copper braid armour.
The black halogen-free SHF1 polyolefin outer sheath provides the external protective layer. An SHF2 sheath is available on request according to the reference product documentation.
MPRXCX FLEXISHIP is the flexible version of the cable family, developed for installations and connections in confined spaces where cable flexibility and reduced installation space are important.
Selected multicore FLEXISHIP configurations incorporate sector-shaped conductors, reducing cable diameter and weight compared with corresponding circular-conductor versions.
The combined reference range covers power and control cable configurations from 1.5 to 300 mm² and from 1 to 37 cores, depending on the selected cable variant.
Key Technical Features
Cable Variants
MPRXCX – Standard Marine Cable
Class 2 Stranded Copper Conductors
Screened and armoured power and control cable for fixed marine electrical installations.
Reference conductor cross-sections: 1.5 and 2.5 mm².
Reference core configurations: 1, 2, 3, 4, 5, 7, 12, 19, 27 and 37 cores.
Configurations with and without green/yellow protective earth conductors are available within the reference range.
MPRXCX FLEXISHIP – Flexible Marine Cable
Flexible Class 5 Copper Conductors
Flexible marine power cable for installations and connections in confined spaces.
Reference conductor cross-sections: 4–300 mm².
Reference core configurations: 1–5 cores.
Circular and selected sector-shaped conductor configurations provide installation options for different cable routing requirements.
Construction & Technical Properties
Cable Construction
Electrical & Mechanical Data
Copper Braid Armour & Electromagnetic Screening
Mechanical Protection
The bare copper braid provides additional mechanical protection around the insulated cable assembly.
The armoured construction is intended for marine electrical installations requiring enhanced protection compared with unarmoured cable designs.
Electromagnetic Screening
The copper braid also provides electrical screening against electromagnetic interference.
Screen termination, bonding and earthing must be designed according to the requirements of the electrical installation.
FLEXISHIP Flexible Conductor Technology
Circular Copper Conductors
The FLEXISHIP range incorporates flexible copper conductor construction for installations and connections in confined spaces.
Circular conductor configurations are included throughout the reference single-core and multicore product range.
Sector-Shaped Copper Conductors
Selected three-core FLEXISHIP configurations incorporate sector-shaped conductors to reduce overall cable dimensions and weight.
Reference sector-shaped configurations include 3x70, 3x95, 3x120 and 3x150 mm².
For example, the reference 3x70 mm² sector-shaped version has a nominal diameter of 28.0 mm compared with 34.6 mm for the circular version.
Halogen-Free Sheath & Fire Performance
SHF1 / SHF2 Outer Sheath
The standard outer sheath is manufactured from halogen-free SHF1 polyolefin compound.
SHF2 is identified as an alternative sheath available on request.
Specific environmental resistance requirements must be confirmed for the selected sheath construction.
Flame Retardancy & Low Smoke
The reference documentation specifies single-cable flame propagation performance according to IEC 60332-1 and bunched-cable flame propagation performance according to IEC 60332-3-22 Category A.
Halogen content, gas corrosivity and smoke density are addressed by IEC 60754-1, IEC 60754-2 and IEC 61034.
Fire-resistant circuit integrity is not specified and must not be inferred from flame-retardant performance.
Typical Applications
Installation Conditions
MPRXCX is intended for fixed electrical installations requiring mechanical protection and electromagnetic screening.
The FLEXISHIP variant is particularly suitable for installations and connections where available routing space is limited.
The specified operating temperature range is -30°C to +80°C, with a maximum conductor temperature in service of +90°C.
Published current ratings refer to open-air installation conditions. Actual permissible current must be determined according to installation method, ambient temperature, cable grouping and applicable marine electrical regulations.
Numerical minimum bending radii, maximum pulling forces and short-circuit temperature limits are not provided in the reference documentation.
Suitability for continuous movement, permanent water immersion, direct burial and specific offshore environmental conditions must be confirmed separately.
Applicable Standards
IEC 60092-350 – General construction and test requirements for shipboard and offshore electrical cables.
IEC 60092-353 – Shipboard power cable requirements for the applicable voltage class.
IEC 60092-360 – Insulating and sheathing materials for shipboard and offshore cables.
IEC 60228 – Conductors of insulated cables.
IEC 60332-1 – Single-cable vertical flame propagation testing.
IEC 60332-3-22 Category A – Vertical flame spread testing of vertically mounted bunched cables.
IEC 60754-1 – Halogen acid gas content.
IEC 60754-2 – Acidity and conductivity of gases evolved during combustion.
IEC 61034 – Measurement of smoke density under defined combustion conditions.
Marine Classification & Project Documentation
Marine classification society approvals and project-specific certification requirements must be confirmed for the selected cable manufacturer, construction and production reference.
DNV, ABS, Bureau Veritas, Lloyd's Register, RINA and other classification approvals must not be assumed solely from compliance with IEC 60092 cable standards.
Required type approvals, test certificates and conformity documentation should be specified during the quotation process.
Related Marine Cable Types
Marine Power & Control Cables
MPRXCX – Screened and armoured marine power and control cable.
MPRXCX FLEXISHIP – Flexible screened and armoured marine cable.
MPRX – Related marine power cable designation.
Marine Cable Selection
Unarmoured marine power cables.
Screened marine instrumentation cables.
Fire-resistant marine safety circuit cables.
Marine medium-voltage power cables.
Each cable type must be selected according to its individual construction, voltage rating, fire performance and classification requirements.
MPRXCX / MPRXCX FLEXISHIP – Cable Sizes & Technical Data
Complete reference range of screened and armoured marine power and control cables rated 0.6/1 (1.2) kV, including circular and sector-shaped conductor configurations, cable dimensions, approximate weights, permissible open-air current ratings and protective earth identification.
MPRXCX – Standard Marine Power & Control Cables
| Cable Size (mm²) | Number of Cores | Conductor Shape | Nominal Diameter (mm) | Min. Diameter (mm) | Max. Diameter (mm) | Approx. Weight (kg/km) | Open-Air Current (A) | Green/Yellow Core |
|---|---|---|---|---|---|---|---|---|
| MPRXCX – Single-Core Cables | ||||||||
| 1x1.5 | 1 | Circular | 5.9 | 5.8 | 7.2 | 58 | 23 | No |
| 1x2.5 | 1 | Circular | 6.3 | 6.2 | 7.6 | 70 | 30 | No |
| MPRXCX – Two-Core Cables | ||||||||
| 2x1.5 | 2 | Circular | 9.3 | 8.3 | 12.0 | 111 | 20 | No |
| 2x2.5 | 2 | Circular | 10.0 | 9.1 | 13.0 | 136 | 26 | No |
| MPRXCX – Three-Core Cables | ||||||||
| 3x1.5 | 3 | Circular | 9.7 | 8.8 | 12.0 | 134 | 16 | No |
| 3G1.5 | 3 | Circular | 9.7 | 8.8 | 12.0 | 134 | 16 | Yes |
| 3x2.5 | 3 | Circular | 10.6 | 10.0 | 13.0 | 170 | 21 | No |
| 3G2.5 | 3 | Circular | 10.6 | 10.0 | 13.0 | 170 | 21 | Yes |
| MPRXCX – Four-Core Cables | ||||||||
| 4x1.5 | 4 | Circular | 10.3 | 9.8 | 13.5 | 162 | 16 | No |
| 4G1.5 | 4 | Circular | 10.3 | 9.8 | 13.5 | 162 | 16 | Yes |
| 4x2.5 | 4 | Circular | 11.4 | 11.0 | 14.5 | 207 | 21 | No |
| 4G2.5 | 4 | Circular | 11.4 | 11.0 | 14.5 | 207 | 21 | Yes |
| MPRXCX – Five-Core Cables | ||||||||
| 5x1.5 | 5 | Circular | 11.5 | 10.5 | 14.5 | 199 | 16 | No |
| 5G1.5 | 5 | Circular | 11.5 | 10.5 | 14.5 | 199 | 16 | Yes |
| 5x2.5 | 5 | Circular | 12.6 | 12.0 | 15.5 | 255 | 21 | No |
| 5G2.5 | 5 | Circular | 12.6 | 12.0 | 15.5 | 255 | 21 | Yes |
| MPRXCX – Seven-Core Cables | ||||||||
| 7x1.5 | 7 | Circular | 12.2 | 11.5 | 15.0 | 242 | 12 | No |
| 7G1.5 | 7 | Circular | 12.2 | 11.5 | 15.0 | 242 | 12 | Yes |
| 7x2.5 | 7 | Circular | 13.4 | 11.5 | 15.0 | 304 | 16 | No |
| 7G2.5 | 7 | Circular | 13.4 | 11.5 | 15.0 | 304 | 16 | Yes |
| MPRXCX – Twelve-Core Cables | ||||||||
| 12x1.5 | 12 | Circular | 16.2 | 15.3 | 18.5 | 405 | 10 | No |
| 12x2.5 | 12 | Circular | 18.1 | 16.8 | 19.4 | 537 | 13 | No |
| MPRXCX – Nineteen-Core Cables | ||||||||
| 19x1.5 | 19 | Circular | 18.8 | 18.0 | 22.0 | 575 | 9 | No |
| 19x2.5 | 19 | Circular | 21.0 | 20.0 | 25.0 | 775 | 11 | No |
| 19G2.5 | 19 | Circular | 21.0 | 20.0 | 25.0 | 775 | 11 | Yes |
| MPRXCX – Twenty-Seven-Core Cables | ||||||||
| 27x1.5 | 27 | Circular | 22.6 | 21.5 | 26.5 | 787 | 8 | No |
| 27x2.5 | 27 | Circular | 25.1 | 24.0 | 30.0 | 1075 | 10 | No |
| MPRXCX – Thirty-Seven-Core Cables | ||||||||
| 37x1.5 | 37 | Circular | 25.0 | 23.5 | 28.0 | 1033 | 7 | No |
| 37x2.5 | 37 | Circular | 28.0 | 27.0 | 33.0 | 1400 | 9 | No |
MPRXCX FLEXISHIP – Flexible Marine Power Cables
| Cable Size (mm²) | Number of Cores | Conductor Shape | Nominal Diameter (mm) | Min. Diameter (mm) | Max. Diameter (mm) | Approx. Weight (kg/km) | Open-Air Current (A) | Green/Yellow Core |
|---|---|---|---|---|---|---|---|---|
| FLEXISHIP – Single-Core Cables | ||||||||
| 1x4 | 1 | Circular | 6.8 | 6.6 | 8.4 | 89 | 51 | No |
| 1x6 | 1 | Circular | 7.6 | 7.4 | 9.6 | 108 | 52 | No |
| 1x10 | 1 | Circular | 8.4 | 8.6 | 11.0 | 151 | 72 | No |
| 1x16 | 1 | Circular | 9.8 | 9.2 | 11.0 | 222 | 96 | No |
| 1x25 | 1 | Circular | 11.1 | 10.5 | 14.0 | 319 | 127 | No |
| 1x35 | 1 | Circular | 13.3 | 12.5 | 15.5 | 429 | 157 | No |
| 1x50 | 1 | Circular | 15.4 | 14.5 | 17.0 | 628 | 196 | No |
| 1x70 | 1 | Circular | 17.9 | 16.5 | 19.0 | 846 | 242 | No |
| 1x95 | 1 | Circular | 19.7 | 18.5 | 21.0 | 1069 | 293 | No |
| 1x120 | 1 | Circular | 22.0 | 20.5 | 23.0 | 1326 | 339 | No |
| 1x150 | 1 | Circular | 24.4 | 23.0 | 27.0 | 1617 | 389 | No |
| 1x185 | 1 | Circular | 26.1 | 24.7 | 27.2 | 1945 | 444 | No |
| 1x240 | 1 | Circular | 29.5 | 28.5 | 31.5 | 2511 | 522 | No |
| 1x300 | 1 | Circular | 32.8 | 30.0 | 33.3 | 3069 | 601 | No |
| FLEXISHIP – Two-Core Cables | ||||||||
| 2x4 | 2 | Circular | 11.7 | 11.0 | 14.0 | 181 | 34 | No |
| 2x6 | 2 | Circular | 12.5 | 12.0 | 15.0 | 219 | 44 | No |
| 2x10 | 2 | Circular | 14.1 | 14.5 | 18.0 | 308 | 61 | No |
| 2x16 | 2 | Circular | 16.8 | 16.0 | 21.5 | 479 | 82 | No |
| 2x25 | 2 | Circular | 21.2 | 21.0 | 25.0 | 775 | 108 | No |
| FLEXISHIP – Three-Core Cables | ||||||||
| 3x4 | 3 | Circular | 11.7 | 11.5 | 14.5 | 223 | 28 | No |
| 3G4 | 3 | Circular | 11.7 | 11.5 | 14.5 | 223 | 34 | Yes |
| 3x6 | 3 | Circular | 12.8 | 12.5 | 16.0 | 286 | 36 | No |
| 3G6 | 3 | Circular | 12.8 | 12.5 | 16.0 | 286 | 44 | Yes |
| 3x10 | 3 | Circular | 15.6 | 14.0 | 18.0 | 473 | 50 | No |
| 3G10 | 3 | Circular | 15.6 | 14.0 | 18.0 | 473 | 61 | Yes |
| 3x16 | 3 | Circular | 18.2 | 18.5 | 22.5 | 645 | 67 | No |
| 3G16 | 3 | Circular | 18.2 | 18.5 | 22.5 | 645 | 67 | Yes |
| 3x25 | 3 | Circular | 21.5 | 22.0 | 26.5 | 986 | 89 | No |
| 3G25 | 3 | Circular | 21.5 | 22.0 | 26.5 | 986 | 108 | Yes |
| 3x35 | 3 | Circular | 25.9 | 24.0 | 27.0 | 1381 | 110 | No |
| 3x50 | 3 | Circular | 29.0 | 28.0 | 31.0 | 1887 | 137 | No |
| 3x70 | 3 | Circular | 34.6 | 32.0 | 36.0 | 2628 | 169 | No |
| 3x70 | 3 | Sector-Shaped | 28.0 | 27.5 | 31.5 | 2256 | 169 | No |
| 3x95 | 3 | Circular | 38.3 | 36.5 | 40.0 | 3263 | 205 | No |
| 3x95 | 3 | Sector-Shaped | 31.3 | 31.5 | 36.0 | 3013 | 205 | No |
| 3x120 | 3 | Circular | 43.3 | 38.0 | 45.0 | 4197 | 237 | No |
| 3x120 | 3 | Sector-Shaped | 35.2 | 34.0 | 39.5 | 3968 | 237 | No |
| 3x150 | 3 | Sector-Shaped | 39.7 | 39.5 | 45.5 | 4581 | 272 | No |
| FLEXISHIP – Four-Core Cables | ||||||||
| 4x4 | 4 | Circular | 13.2 | 12.5 | 15.0 | 280 | 28 | No |
| 4G4 | 4 | Circular | 13.2 | 12.5 | 15.0 | 280 | 28 | Yes |
| 4x6 | 4 | Circular | 15.0 | 14.5 | 16.0 | 401 | 36 | No |
| 4G6 | 4 | Circular | 15.0 | 14.5 | 16.0 | 401 | 36 | Yes |
| 4x10 | 4 | Circular | 17.0 | 17.0 | 20.5 | 589 | 50 | No |
| 4G10 | 4 | Circular | 17.0 | 17.0 | 20.5 | 589 | 50 | Yes |
| 4x16 | 4 | Circular | 20.1 | 18.7 | 21.5 | 838 | 67 | No |
| 4G16 | 4 | Circular | 19.0 | 20.5 | 23.0 | 849 | 67 | Yes |
| 4x25 | 4 | Circular | 25.0 | 24.0 | 27.0 | 1310 | 89 | No |
| 4x35 | 4 | Circular | 28.6 | 26.5 | 29.5 | 1776 | 110 | No |
| 4x50 | 4 | Circular | 31.9 | 31.0 | 34.5 | 2394 | 137 | No |
| 4x70 | 4 | Circular | 38.4 | 35.5 | 40.0 | 3381 | 169 | No |
| 4x95 | 4 | Circular | 42.9 | 41.5 | 45.0 | 4343 | 205 | No |
| FLEXISHIP – Five-Core Cables | ||||||||
| 5G4 | 5 | Circular | 13.8 | 14.5 | 18.0 | 336 | 28 | Yes |
| 5G6 | 5 | Circular | 16.3 | 15.5 | 19.5 | 487 | 36 | Yes |
| 5G10 | 5 | Circular | 18.2 | 18.0 | 20.0 | 717 | 50 | Yes |
| 5G16 | 5 | Circular | 21.9 | 22.5 | 27.0 | 1015 | 67 | Yes |
| 5G35 | 5 | Circular | 31.6 | 29.5 | 35.0 | 2098 | 110 | Yes |
| 5G50 | 5 | Circular | 35.4 | 34.0 | 40.5 | 2863 | 137 | Yes |
| 5G70 | 5 | Circular | 43.0 | 40.0 | 46.0 | 4158 | 169 | Yes |
The letter G identifies a configuration including a green/yellow protective earth conductor. The letter x identifies a configuration without a green/yellow protective earth conductor. All dimensions, weights and current ratings are reference values.
Cable Range Summary
| Cable Variant | Conductor Range | Conductor Class | Number of Cores | Configurations |
|---|---|---|---|---|
| MPRXCX | 1.5–2.5 mm² | Class 2 | 1–37 | 29 |
| MPRXCX FLEXISHIP | 4–300 mm² | Class 5 | 1–5 | 55 |
| Combined Range | 1.5–300 mm² | Class 2 / Class 5 | 1–37 | 84 |
Circular vs. Sector-Shaped Conductors
| Cable Size | Circular Diameter (mm) | Sector Diameter (mm) | Diameter Reduction | Circular Weight (kg/km) | Sector Weight (kg/km) | Weight Reduction | Current Rating (A) |
|---|---|---|---|---|---|---|---|
| 3x70 | 34.6 | 28.0 | 19.1% | 2628 | 2256 | 14.2% | 169 |
| 3x95 | 38.3 | 31.3 | 18.3% | 3263 | 3013 | 7.7% | 205 |
| 3x120 | 43.3 | 35.2 | 18.7% | 4197 | 3968 | 5.5% | 237 |
| 3x150 | Not Listed | 39.7 | Not Applicable | Not Listed | 4581 | Not Applicable | 272 |
Percentage reductions are calculated from the published nominal diameters and approximate cable weights. The reference documentation does not include a corresponding circular 3x150 mm² configuration.
Electrical Characteristics
| Parameter | Reference Value |
|---|---|
| Rated Voltage U0/U | 0.6/1 kV |
| Maximum System Voltage Um | 1.2 kV |
| Materijal vodiča | Bare Copper |
| Standard Conductor Class | Class 2 |
| FLEXISHIP Conductor Class | Class 5 |
| Conductor Standard | IEC 60228 |
| Core Insulation | Cross-Linked Polyethylene (XLPE) |
| Electromagnetic Screening | Bare Copper Braid |
| Permissible Open-Air Current | 7–601 A, Depending on Configuration |
| Test Voltage | Not Specified |
| Conductor DC Resistance | Not Specified |
| Insulation Resistance | Not Specified |
| Short-Circuit Current Rating | Not Specified |
Temperature Characteristics
| Installation / Operating Condition | Minimum Temperature | Maximum Temperature |
|---|---|---|
| Operating Temperature | -30°C | +80°C |
| Conductor Temperature in Service | Not Specified | +90°C |
| Installation Temperature | Not Separately Specified | Not Separately Specified |
| Short-Circuit Temperature | Not Specified | Not Specified |
Cable Construction Layers
| Layer | Component | Material / Construction |
|---|---|---|
| 1 | Conductor | Stranded Bare Copper Class 2 or Flexible Bare Copper Class 5 |
| 2 | Core Insulation | XLPE |
| 3 | Inner Covering | Lapped Covering, with Filler if Necessary |
| 4 | Armouring / Screen | Bare Copper Braid |
| 5 | Outer Sheath | Black Halogen-Free Polyolefin SHF1, SHF2 on Request |
Core Identification & Cable Configurations
| Configuration | Core Identification | Protective Earth |
|---|---|---|
| 1 Core | Crna | No |
| 2x | Brown, Blue | No |
| 3x | Brown, Black, Grey | No |
| 3G | Brown, Blue, Green/Yellow | Yes |
| 4x | Brown, Black, Grey, Blue | No |
| 4G | Brown, Black, Grey, Green/Yellow | Yes |
| 5x | White with Printed Numbers | No |
| 5G | Brown, Black, Grey, Blue, Green/Yellow | Yes |
| More than 5 Cores – nx | White with Printed Numbers | No |
| More than 5 Cores – nG | White with Printed Numbers and Green/Yellow Core | Yes |
Mechanical & Environmental Characteristics
| Parameter | Reference Value |
|---|---|
| Armour Material | Bare Copper Braid |
| Mechanical Protection | Enhanced by Copper Braid Armour |
| Electromagnetic Interference Resistance | Yes |
| Outer Sheath | SHF1 Polyolefin |
| Alternative Outer Sheath | SHF2 on Request |
| Sheath Colour | Crna |
| Fixed Marine Installation | Suitable |
| Confined Installation Spaces | FLEXISHIP Recommended |
| Minimum Bending Radius | Numerical Value Not Specified |
| Maximum Pulling Force | Not Specified |
| Oil Resistance Test | Not Separately Specified |
| UV Resistance | Not Specified |
| Permanent Water Immersion | Not Specified |
| Direct Burial | Not Specified |
| Continuous-Flex Applications | Not Specified |
| Torsional Applications | Not Specified |
Fire Performance Characteristics
| Parameter | Reference Standard / Value |
|---|---|
| Single Cable Flame Propagation | IEC 60332-1 |
| Bunched Cable Flame Propagation | IEC 60332-3-22 Category A |
| Halogen-Free Performance | IEC 60754-1 |
| Gas Corrosivity | IEC 60754-2 |
| Smoke Density | IEC 61034 |
| Gas Toxicity | Listed as No in Reference Documentation; Test Standard Not Specified |
| CPR Euroclass | Not Specified |
| Fire-Resistant Circuit Integrity | Not Specified |
| IEC 60331 Fire Resistance | Not Specified |
Applicable Standards
| Standard | Reference Application |
|---|---|
| IEC 60092-350 | General Marine Cable Construction and Test Requirements |
| IEC 60092-353 | Marine Power Cable Requirements |
| IEC 60092-360 | Marine Cable Insulation and Sheathing Materials |
| IEC 60228 | Conductors of Insulated Cables |
| IEC 60332-1 | Single Cable Flame Propagation |
| IEC 60332-3-22 | Bunched Cable Flame Propagation, Category A |
| IEC 60754-1 | Halogen Acid Gas Content |
| IEC 60754-2 | Gas Acidity and Conductivity |
| IEC 61034 | Smoke Density Measurement |
Marine Classification & Certification
| Classification / Documentation | Reference Status |
|---|---|
| DNV Type Approval | Subject to Manufacturer Confirmation |
| ABS Type Approval | Subject to Manufacturer Confirmation |
| Bureau Veritas Type Approval | Subject to Manufacturer Confirmation |
| Lloyd's Register Type Approval | Subject to Manufacturer Confirmation |
| RINA Type Approval | Subject to Manufacturer Confirmation |
| Declaration of Conformity | Confirm for Supplied Product |
| Declaration of Performance | Confirm Where Applicable |
| Manufacturer Test Certificate | Confirm During Quotation |