J-Y(ST)Y – Shielded Telecommunication Installation Cable
Shielded indoor telecommunication installation cable with solid bare copper conductors, PVC core insulation, aluminium foil static screen with drain wire and a grey PVC outer sheath. Designed for fixed indoor telecommunication installations.
Product Overview
J-Y(ST)Y is a shielded telecommunication installation cable designed for permanent fixed installation in indoor communication systems.
The cable incorporates solid bare copper conductors with nominal conductor diameters of 0.6 mm or 0.8 mm. Each conductor is insulated with polyvinyl chloride (PVC).
A static screen consisting of plastic-coated aluminium foil with a drain wire provides electrostatic shielding for the communication circuits.
The cable construction is completed with a grey PVC outer sheath suitable for the specified indoor installation conditions.
The reference product range includes configurations from 1 to 100 pairs, depending on the selected conductor diameter.
Key Technical Features
Cable Variants
J-Y(ST)Y – 0.6 mm
Solid Copper Conductor Diameter: 0.6 mm
Reference configurations from 1 to 100 pairs, with a conductor loop resistance of 130.0 Ω/km.
Approximate cable diameters range from 4.5 to 22.1 mm.
J-Y(ST)Y – 0.8 mm
Solid Copper Conductor Diameter: 0.8 mm
Reference configurations from 1 to 60 pairs, with a conductor loop resistance of 73.2 Ω/km.
Approximate cable diameters range from 5.5 to 25.8 mm.
Cable Designation
Construction & Technical Properties
Cable Construction
Electrical & Mechanical Data
Typical Applications
Applicable Standards
DIN VDE 0815 – Reference standard for core identification of telecommunication installation cables.
DIN EN 60228, Class 1 – Solid conductor construction, as referenced in the technical documentation.
EN 60332-1-2 – Vertical flame propagation test for a single insulated wire or cable.
EN 60332-2-2 – Vertical flame propagation test for small insulated wires or cables.
Installation Conditions
J-Y(ST)Y is intended for fixed telecommunication installations inside buildings.
The permitted temperature range during bending is -5°C to +50°C. Once installed in a fixed position, the specified temperature range is -30°C to +70°C.
A minimum bending radius of 15 times the cable outer diameter must be maintained during bending.
The cable is intended for communication applications and is not specified as a general-purpose power distribution cable.
J-Y(ST)Y – Cable Sizes & Technical Data
28 reference configurations of shielded telecommunication installation cables with solid copper conductors, nominal conductor diameters of 0.6 mm and 0.8 mm, copper content, insulation thickness, outer diameter and approximate cable weight.
Available Cable Sizes & Dimensions
| Tip kabela | Configuration | Number of Pairs | Conductor Diameter (mm) | Copper Content (kg/km) | Insulation Thickness (mm) | Approx. Outer Diameter (mm) | Approx. Cable Weight (kg/km) |
|---|---|---|---|---|---|---|---|
| J-Y(ST)Y – Solid Copper Conductor Ø 0.6 mm | |||||||
| J-Y(ST)Y | 1x2x0.6 | 1 | 0.6 | 6.7 | 1.1 | 4.5 | 26 |
| J-Y(ST)Y | 2x2x0.6 | 2 | 0.6 | 12.5 | 1.1 | 4.9 | 35 |
| J-Y(ST)Y | 3x2x0.6 | 3 | 0.6 | 18.2 | 1.1 | 6.2 | 49 |
| J-Y(ST)Y | 4x2x0.6 | 4 | 0.6 | 23.0 | 1.1 | 6.6 | 58 |
| J-Y(ST)Y | 5x2x0.6 | 5 | 0.6 | 28.8 | 1.1 | 7.1 | 59 |
| J-Y(ST)Y | 6x2x0.6 | 6 | 0.6 | 34.6 | 1.1 | 7.6 | 61 |
| J-Y(ST)Y | 10x2x0.6 | 10 | 0.6 | 56.6 | 1.1 | 9.3 | 113 |
| J-Y(ST)Y | 12x2x0.6 | 12 | 0.6 | 69.1 | 1.1 | 9.5 | 129 |
| J-Y(ST)Y | 20x2x0.6 | 20 | 0.6 | 111.4 | 1.1 | 10.9 | 191 |
| J-Y(ST)Y | 30x2x0.6 | 30 | 0.6 | 165.1 | 1.3 | 13.7 | 284 |
| J-Y(ST)Y | 40x2x0.6 | 40 | 0.6 | 218.9 | 1.3 | 14.5 | 358 |
| J-Y(ST)Y | 50x2x0.6 | 50 | 0.6 | 273.6 | 1.3 | 16.5 | 438 |
| J-Y(ST)Y | 60x2x0.6 | 60 | 0.6 | 328.3 | 1.3 | 17.5 | 512 |
| J-Y(ST)Y | 100x2x0.6 | 100 | 0.6 | 545.3 | 1.5 | 22.1 | 829 |
| J-Y(ST)Y – Solid Copper Conductor Ø 0.8 mm | |||||||
| J-Y(ST)Y | 1x2x0.8 | 1 | 0.8 | 10.6 | 1.1 | 5.5 | 38 |
| J-Y(ST)Y | 2x2x0.8 | 2 | 0.8 | 20.2 | 1.1 | 6.1 | 54 |
| J-Y(ST)Y | 3x2x0.8 | 3 | 0.8 | 29.8 | 1.1 | 8.0 | 77 |
| J-Y(ST)Y | 4x2x0.8 | 4 | 0.8 | 39.4 | 1.1 | 8.7 | 94 |
| J-Y(ST)Y | 5x2x0.8 | 5 | 0.8 | 49.9 | 1.1 | 9.4 | 114 |
| J-Y(ST)Y | 6x2x0.8 | 6 | 0.8 | 59.5 | 1.1 | 10.1 | 135 |
| J-Y(ST)Y | 10x2x0.8 | 10 | 0.8 | 98.9 | 1.3 | 13.1 | 205 |
| J-Y(ST)Y | 12x2x0.8 | 12 | 0.8 | 118.1 | 1.3 | 13.5 | 235 |
| J-Y(ST)Y | 16x2x0.8 | 16 | 0.8 | 157.4 | 1.3 | 14.8 | 299 |
| J-Y(ST)Y | 20x2x0.8 | 20 | 0.8 | 194.9 | 1.3 | 15.6 | 352 |
| J-Y(ST)Y | 30x2x0.8 | 30 | 0.8 | 291.8 | 1.5 | 19.4 | 522 |
| J-Y(ST)Y | 40x2x0.8 | 40 | 0.8 | 387.8 | 1.5 | 20.9 | 663 |
| J-Y(ST)Y | 50x2x0.8 | 50 | 0.8 | 484.8 | 1.7 | 23.7 | 832 |
| J-Y(ST)Y | 60x2x0.8 | 60 | 0.8 | 581.8 | 1.7 | 25.8 | 978 |
Cable configuration is expressed as number of pairs x two conductors x nominal conductor diameter in millimetres. All 28 configurations are reproduced from the reference technical documentation.
Conductor Characteristics
| Parameter | 0.6 mm Conductor | 0.8 mm Conductor |
|---|---|---|
| Materijal vodiča | Bare Copper | Bare Copper |
| Conductor Class | Class 1 | Class 1 |
| Nominal Conductor Diameter | 0.6 mm | 0.8 mm |
| Calculated Geometric Cross-Section | 0.283 mm² | 0.503 mm² |
| Conductor Loop Resistance | 130.0 Ω/km | 73.2 Ω/km |
| Reference Pair Range | 1–100 Pairs | 1–60 Pairs |
| Approximate Outer Diameter Range | 4.5–22.1 mm | 5.5–25.8 mm |
| Copper Content Range | 6.7–545.3 kg/km | 10.6–581.8 kg/km |
| Approximate Cable Weight Range | 26–829 kg/km | 38–978 kg/km |
Geometric conductor cross-sections are calculated from the nominal conductor diameters using the circular area formula. They are provided for reference only and do not replace the original diameter-based cable designation.
Electrical Characteristics
| Parameter | Reference Value | Condition |
|---|---|---|
| Peak Operating Voltage | 300 V | Telecommunication Applications |
| Test Voltage – Core/Core | 800 V AC | 50 Hz |
| Test Voltage – Core/Screen | 800 V AC | 50 Hz |
| Conductor Loop Resistance | 130.0 Ω/km | 0.6 mm Conductor |
| Conductor Loop Resistance | 73.2 Ω/km | 0.8 mm Conductor |
| Minimum Insulation Resistance | 100 MΩ/km | Unit as Stated in Reference |
| Maximum Operating Capacitance | 10 nF/km | To Be Confirmed |
| Maximum Capacitance Unbalance | 300 pF | Per 100 m |
Mechanical & Installation Characteristics
| Parameter | Reference Value |
|---|---|
| Minimum Bending Radius | 15 x Cable Outer Diameter |
| Installation Environment | Indoor |
| Installation Type | Fixed Installation |
| Conductor Construction | Solid Copper, Class 1 |
| Izolacijski materijal | PVC |
| Insulation Thickness Range | 1.1–1.7 mm (as labelled in reference) |
| Screen Construction | Plastic-Coated Aluminium Foil with Drain Wire |
| Outer Sheath Material | PVC |
| Outer Sheath Colour | Grey |
| Approximate Outer Diameter Range | 4.5–25.8 mm |
| Approximate Cable Weight Range | 26–978 kg/km |
Temperature Characteristics
| Condition | Minimum Temperature | Maximum Temperature |
|---|---|---|
| During Bending | -5°C | +50°C |
| Fixed Installation | -30°C | +70°C |
Minimum Bending Radius – Calculated Values
| Configuration | Approx. Outer Diameter (mm) | Minimum Bending Radius – 15 x D (mm) |
|---|---|---|
| Conductor Diameter 0.6 mm | ||
| 1x2x0.6 | 4.5 | 67.5 |
| 2x2x0.6 | 4.9 | 73.5 |
| 3x2x0.6 | 6.2 | 93.0 |
| 4x2x0.6 | 6.6 | 99.0 |
| 5x2x0.6 | 7.1 | 106.5 |
| 6x2x0.6 | 7.6 | 114.0 |
| 10x2x0.6 | 9.3 | 139.5 |
| 12x2x0.6 | 9.5 | 142.5 |
| 20x2x0.6 | 10.9 | 163.5 |
| 30x2x0.6 | 13.7 | 205.5 |
| 40x2x0.6 | 14.5 | 217.5 |
| 50x2x0.6 | 16.5 | 247.5 |
| 60x2x0.6 | 17.5 | 262.5 |
| 100x2x0.6 | 22.1 | 331.5 |
| Conductor Diameter 0.8 mm | ||
| 1x2x0.8 | 5.5 | 82.5 |
| 2x2x0.8 | 6.1 | 91.5 |
| 3x2x0.8 | 8.0 | 120.0 |
| 4x2x0.8 | 8.7 | 130.5 |
| 5x2x0.8 | 9.4 | 141.0 |
| 6x2x0.8 | 10.1 | 151.5 |
| 10x2x0.8 | 13.1 | 196.5 |
| 12x2x0.8 | 13.5 | 202.5 |
| 16x2x0.8 | 14.8 | 222.0 |
| 20x2x0.8 | 15.6 | 234.0 |
| 30x2x0.8 | 19.4 | 291.0 |
| 40x2x0.8 | 20.9 | 313.5 |
| 50x2x0.8 | 23.7 | 355.5 |
| 60x2x0.8 | 25.8 | 387.0 |
Minimum bending radii are calculated using the approximate outer diameters and the specified factor of 15 x D. Actual installation requirements must be based on the supplied cable dimensions.
Applicable Technical Standards
| Standard | Reference Application |
|---|---|
| DIN VDE 0815 | Core Identification |
| DIN EN 60228 | Class 1 Conductor Construction |
| EN 60332-1-2 | Vertical Flame Propagation Test for a Single Insulated Wire or Cable |
| EN 60332-2-2 | Vertical Flame Propagation Test for Small Insulated Wires or Cables |