A-DQ2Y – Optical Mini Cable G.657A1/G.652D (HT)
Compact single-mode optical fibre mini cable with stranded loose tubes, dielectric FRP strength member, dry water-blocking construction and a black HDPE outer sheath. Designed for installation by blowing into microducts.
Product Overview
A-DQ2Y Optical Mini Cable is a compact optical communication cable designed for installation by blowing into microduct systems.
The cable incorporates stranded loose tubes, each containing 12 optical fibres protected by a thixotropic filling compound.
A central fibre-reinforced plastic (FRP) strength member provides mechanical reinforcement. Depending on the cable configuration, the central strength member may include additional oversheathing. Dummy elements are incorporated where required.
The cable core features a dry water-blocking construction, while the black high-density polyethylene (HDPE) outer sheath provides external protection. A rip cord beneath the outer sheath facilitates cable preparation.
The reference cable range includes seven configurations from 12 to 288 single-mode optical fibres, with approximate outer diameters between 5.5 and 9.4 mm.
Key Technical Features
Cable Designation
Construction & Technical Properties
Cable Construction
Mechanical & Environmental Data
Optical Performance
Typical Applications
Applicable Standards
IEC 60793-1 – Optical fibre measurement methods and test procedures.
IEC 60793-2 – Optical fibre product specifications.
IEC 60794-5 – Microduct cabling systems for installation by blowing.
ITU-T G.657A1 – Reference optical fibre specification for bending-loss insensitive single-mode fibres.
G.652D – Additional fibre designation stated in the reference product name.
Installation Conditions
The A-DQ2Y optical mini cable is intended for single-cable installation in microducts using cable blowing equipment.
The required microduct dimensions depend on the selected cable diameter and fibre configuration.
Recommended microduct dimensions for selected 72, 96, 144 and 288 fibre configurations are provided in the technical data section.
The specified installation temperature, tensile load and minimum bending radius must be observed during installation.
A-DQ2Y – Cable Sizes & Technical Data
Seven reference single-mode optical mini cable configurations with 12–288 fibres, cable dimensions, mechanical characteristics, optical performance and recommended microduct dimensions.
Available Cable Sizes & Dimensions
| Tip kabela | Configuration | Number of Fibres | Sheath Thickness (mm) | Outer Diameter (mm) | Installation Tensile Load (N) | Crush Resistance (N) | Fibre Type | Cable Weight (kg/km) |
|---|---|---|---|---|---|---|---|---|
| Compact Mini Cables – 5.5 mm Outer Diameter | ||||||||
| A-DQ2Y | 1x12 | 12 | 0.5 | 5.5 | 500 | 300 | Single-Mode | 23 |
| A-DQ2Y | 2x12 | 24 | 0.5 | 5.5 | 500 | 300 | Single-Mode | 23 |
| A-DQ2Y | 4x12 | 48 | 0.5 | 5.5 | 500 | 300 | Single-Mode | 23 |
| A-DQ2Y | 6x12 | 72 | 0.5 | 5.5 | 500 | 300 | Single-Mode | 23 |
| Higher Fibre Count Mini Cables – 6.2–9.4 mm Outer Diameter | ||||||||
| A-DQ2Y | 8x12 | 96 | 0.5 | 6.2 | 1000 | 300 | Single-Mode | 34 |
| A-DQ2Y | 12x12 | 144 | 0.5 | 8.0 | 1000 | 300 | Single-Mode | 55 |
| A-DQ2Y | 24x12 | 288 | 0.5 | 9.4 | 1000 | 300 | Single-Mode | 80 |
Loose Tube & FRP Construction
| Configuration | Fibres | Loose Tubes – Layer 1 | Dummies – Layer 1 | Loose Tubes – Layer 2 | Dummies – Layer 2 | Loose Tube Diameter (mm) | FRP Dimension (mm) |
|---|---|---|---|---|---|---|---|
| 1x12 | 12 | 1 | 5 | – | – | 1.4 | 1.5 |
| 2x12 | 24 | 2 | 4 | – | – | 1.4 | 1.5 |
| 4x12 | 48 | 4 | 2 | – | – | 1.4 | 1.5 |
| 6x12 | 72 | 6 | 0 | – | – | 1.4 | 1.5 |
| 8x12 | 96 | 8 | 0 | – | – | 1.4 | 4.0 |
| 12x12 | 144 | 12 | 0 | – | – | 1.4 | 4.2 / 2.0 |
| 24x12 | 288 | 9 | 0 | 15 | 0 | 1.4 | 2.8 |
Recommended Microduct Dimensions
| Number of Fibres | Cable Diameter (mm) | Recommended Microduct OD/ID (mm) |
|---|---|---|
| 12 | 5.5 | Not specified |
| 24 | 5.5 | Not specified |
| 48 | 5.5 | Not specified |
| 72 | 5.5 | 12/8 |
| 96 | 6.2 | 12/8 or 14/10 |
| 144 | 8.0 | 14/10 or 16/12 |
| 288 | 9.4 | 16/12 or 20/15 |
OD/ID indicates the outer and inner diameter of the microduct. Recommendations are reproduced for the configurations specified in the reference documentation.
Minimum Bending Radius
| Fibre Configuration | Cable Diameter (mm) | Under Tension – 20 x D (mm) | Without Tension – 15 x D (mm) |
|---|---|---|---|
| 12 Fibres | 5.5 | 110 | 82.5 |
| 24 Fibres | 5.5 | 110 | 82.5 |
| 48 Fibres | 5.5 | 110 | 82.5 |
| 72 Fibres | 5.5 | 110 | 82.5 |
| 96 Fibres | 6.2 | 124 | 93 |
| 144 Fibres | 8.0 | 160 | 120 |
| 288 Fibres | 9.4 | 188 | 141 |
Bending radii are calculated using the approximate cable diameters and the specified bending radius factors. Actual minimum bending radii depend on the supplied cable diameter.
Optical Fibre Characteristics – G.657A1/G.652D
| Optical Parameter | Reference Value |
|---|---|
| Reference Fibre Standard | ITU-T G.657A1 |
| Fibre Type | Single-Mode |
| Cabled Fibre Attenuation at 1310 nm | ≤0.36 dB/km |
| Cabled Fibre Attenuation at 1550 nm | ≤0.22 dB/km |
| Mode Field Diameter at 1310 nm | 9.2 ± 0.4 µm |
| Mode Field Diameter at 1550 nm | 10.4 ± 0.8 µm |
| Zero Dispersion Wavelength | 1300–1324 nm |
| Zero Dispersion Slope | ≤0.092 ps/(nm²·km) |
| Polarisation Mode Dispersion (PMD) | ≤0.1 ps/√km |
| Cut-Off Wavelength | ≤1260 nm |
| Macrobending Loss at 1550 nm – 10 Turns, Ø30 mm | ≤0.25 dB |
| Macrobending Loss at 1550 nm – 1 Turn, Ø20 mm | ≤0.75 dB |
| Coated Fibre Outer Diameter | 200 ± 10 / 250 ± 10 µm |
| Cladding Diameter | 125 ± 1.0 µm |
| Core/Cladding Concentricity Error | ≤0.6 µm |
| Cladding Non-Circularity | ≤1.0% |
Mechanical Characteristics
| Parameter | Reference Value | Condition |
|---|---|---|
| Installation Tensile Load | 500 N | 12–72 Fibres |
| Installation Tensile Load | 1000 N | 96–288 Fibres |
| Crush Resistance | 300 N | All Configurations |
| Minimum Bending Radius | 20 x D | Under Tension |
| Minimum Bending Radius | 15 x D | Without Tension |
| Outer Sheath Thickness | 0.5 mm | All Configurations |
| Loose Tube Diameter | 1.4 mm | All Configurations |
| Installation Method | Cable Blowing | Single Cable in Microduct |
Temperature Characteristics
| Condition | Minimum Temperature | Maximum Temperature |
|---|---|---|
| Operation | -20°C | +60°C |
| Installation | -5°C | +50°C |
| Storage | -20°C | +70°C |
| Transport | -20°C | +70°C |
Optical Fibre Colour Identification
| Fibre No. | Colour | Fibre No. | Colour |
|---|---|---|---|
| 1 | Red | 13 | Red with Black Ring |
| 2 | Green | 14 | Green with Black Ring |
| 3 | Blue | 15 | Blue with Black Ring |
| 4 | Yellow | 16 | Yellow with Black Ring |
| 5 | White | 17 | White with Black Ring |
| 6 | Grey | 18 | Grey with Black Ring |
| 7 | Brown | 19 | Brown with Black Ring |
| 8 | Violet | 20 | Violet with Black Ring |
| 9 | Cyan | 21 | Cyan with Black Ring |
| 10 | Crna | 22 | Natural with Black Ring |
| 11 | Orange | 23 | Orange with Black Ring |
| 12 | Pink | 24 | Pink with Black Ring |
The reference documentation includes a general 24-position fibre colour sequence. The listed A-DQ2Y configurations contain 12 fibres per loose tube.
Loose Tube Colour Identification
| Loose Tube No. | Colour Sequence – Variant 1 | Colour Sequence – Variant 2 |
|---|---|---|
| 1 | Red | Red |
| 2 | Green | Green |
| 3 | Blue | Blue |
| 4 | Yellow | Yellow |
| 5 | White | White |
| 6 | Grey | Grey |
| 7 | Brown | Brown |
| 8 | Violet | Violet |
| 9 | Cyan | Cyan |
| 10 | Crna | Crna |
| 11 | Orange | Orange |
| 12 | Pink | Pink |
| 13 | White | Red with Black Ring |
| 14 | White | Green with Black Ring |
| 15 | White | Blue with Black Ring |
Each loose tube layer begins with position 1. In Variant 1, loose tubes from position 13 are white. In Variant 2, loose tubes from position 13 use ring marking. Dummy elements are natural coloured in both variants.
Applicable Technical Standards
| Standard | Description |
|---|---|
| IEC 60793-1 | Optical Fibre Measurement Methods and Test Procedures |
| IEC 60793-2 | Optical Fibre Product Specifications |
| IEC 60794-5 | Microduct Cabling Systems for Installation by Blowing |
| ITU-T G.657A1 | Bending-Loss Insensitive Single-Mode Optical Fibre Specification |