N2XH FE180 – Fire-Resistant LSZH Power Cable 0.6/1 kV
Halogen-free, flame-retardant power cable with copper conductors, XLPE insulation, mica fire barrier and HFFR outer sheath, designed for electrical installations with enhanced fire safety requirements.
Product Overview
N2XH FE180 is a halogen-free, flame-retardant and fire-resistant low-voltage power cable intended for electrical energy distribution in commercial buildings, industrial facilities and infrastructure projects.
The cable incorporates solid or stranded copper conductors, a mica tape fire barrier, cross-linked polyethylene insulation and a halogen-free flame-retardant outer sheath.
The mica fire barrier is designed to provide additional electrical insulation protection under fire exposure.
The reference product range includes single-core and multicore configurations suitable for different electrical distribution requirements.
Key Technical Features
Cable Construction & Technical Properties
Cable Construction
Electrical & Thermal Properties
Fire-Resistant Cable Construction
The fire-resistant cable design combines copper conductors with a mica tape barrier and XLPE insulation.
The mica layer provides additional protection of the electrical insulation when exposed to elevated temperatures during a fire.
The FE180 designation refers to insulation integrity under specified fire test conditions. The applicable test standard and certified performance must be confirmed using the corresponding manufacturer documentation.
Halogen-Free Flame-Retardant Materials
XLPE Insulation
Cross-linked polyethylene insulation provides electrical insulation and thermal performance for low-voltage power distribution.
The reference maximum operating temperature is +90°C.
HFFR Outer Sheath
Halogen-free flame-retardant materials are used for the outer sheath and applicable filler layers.
The cable construction is intended for installations where fire behaviour and smoke characteristics are important selection criteria.
Typical Project Applications
Installation & Engineering Considerations
Cable selection must consider the rated voltage, conductor cross-section, installation method, ambient temperature, grouping conditions and required fire performance.
Applications involving emergency lighting, fire alarm systems, smoke extraction equipment and other safety-related circuits require verification of the applicable system-level fire resistance requirements.
Current-carrying capacities, bending radii, pulling forces and installation temperatures must be confirmed for the selected cable configuration.
Fire Performance & Certification
N2XH FE180 – Cable Sizes & Technical Data
Fire-resistant, halogen-free, XLPE-insulated copper power cables with mica fire barrier and HFFR outer sheath for low-voltage electrical distribution systems.
Single-Core Cable Sizes
Reference single-core cable configurations. Detailed dimensional and electrical values are subject to manufacturer confirmation.
| Cable Size | Number of Cores | Nominal Cross-Section (mm²) | Materijal vodiča | Radni napon |
|---|---|---|---|---|
| Single-Core Power Cables | ||||
| 1 × 4 | 1 | 4 | Cu | 0.6/1 kV |
| 1 × 6 | 1 | 6 | Cu | 0.6/1 kV |
| 1 × 10 | 1 | 10 | Cu | 0.6/1 kV |
| 1 × 16 | 1 | 16 | Cu | 0.6/1 kV |
| 1 × 25 | 1 | 25 | Cu | 0.6/1 kV |
| 1 × 35 | 1 | 35 | Cu | 0.6/1 kV |
| 1 × 50 | 1 | 50 | Cu | 0.6/1 kV |
| 1 × 70 | 1 | 70 | Cu | 0.6/1 kV |
| 1 × 95 | 1 | 95 | Cu | 0.6/1 kV |
| 1 × 120 | 1 | 120 | Cu | 0.6/1 kV |
| 1 × 150 | 1 | 150 | Cu | 0.6/1 kV |
| 1 × 185 | 1 | 185 | Cu | 0.6/1 kV |
| 1 × 240 | 1 | 240 | Cu | 0.6/1 kV |
| 1 × 300 | 1 | 300 | Cu | 0.6/1 kV |
| 1 × 400 | 1 | 400 | Cu | 0.6/1 kV |
| 1 × 500 | 1 | 500 | Cu | 0.6/1 kV |
Multicore Cable Configurations
| Configuration | Number of Cores | Materijal vodiča | Insulation | Outer Sheath |
|---|---|---|---|---|
| Two-core | 2 | Copper | XLPE | HFFR |
| Three-core | 3 | Copper | XLPE | HFFR |
| Four-core | 4 | Copper | XLPE | HFFR |
| Five-core | 5 | Copper | XLPE | HFFR |
| Reduced additional conductor | Configuration dependent | Copper | XLPE | HFFR |
Electrical Characteristics
| Parameter | Technical Specification |
|---|---|
| Rated Voltage U0/U | 0.6/1 kV |
| Materijal vodiča | Copper |
| Conductor Construction | Solid or stranded |
| Core Insulation | Cross-linked polyethylene (XLPE) |
| Fire Barrier | Mica tape |
| DC Conductor Resistance at 20°C | Configuration-specific value |
| AC Conductor Resistance | Configuration-specific value |
| Current-Carrying Capacity | According to cable size and installation conditions |
| Voltage Drop | According to cable configuration and electrical load |
Cable Construction Layers
| Layer | Material | Function |
|---|---|---|
| 1. Conductor | Solid or stranded copper | Electrical energy transmission |
| 2. Fire Barrier | Mica tape | Additional insulation protection under fire exposure |
| 3. Core Insulation | XLPE | Electrical insulation |
| 4. Filler | HFFR compound | Multicore cable assembly, where applicable |
| 5. Outer Sheath | HFFR compound | External cable protection |
Thermal Characteristics
| Parameter | Reference Value |
|---|---|
| Maximum Continuous Operating Temperature | +90°C |
| Maximum Short-Circuit Temperature | +250°C |
| Minimum Installation Temperature | Subject to manufacturer specification |
| Ambient Temperature Correction | According to installation calculation |
Mechanical & Dimensional Characteristics
| Parameter | Technical Specification |
|---|---|
| Outer Sheath Colour | Orange reference construction |
| Overall Cable Diameter | Configuration dependent |
| Net Cable Weight | Configuration dependent |
| Minimum Bending Radius | Subject to manufacturer specification |
| Maximum Pulling Force | Subject to manufacturer specification |
| Standard Delivery Length | According to selected cable configuration |
| Pakiranje | According to order requirements |
Fire Performance & Certification
| Characteristic | Performance |
|---|---|
| Fire Resistance Designation | FE180 |
| Fire Barrier | Mica tape |
| Halogen-Free Construction | HFFR materials |
| Flame Retardancy | According to applicable test documentation |
| CPR Classification | According to applicable Declaration of Performance |
| Functional Integrity E30/E60/E90 | Separate system certification required |
| Fire Resistance Test Standard | Subject to manufacturer test documentation |
Technical Documentation
| Document | Description |
|---|---|
| TDS | Tehnički list |
| DoP | Declaration of Performance, where applicable |
| DoC | Declaration of Conformity, where applicable |
| Fire Test Report | Verification of declared fire resistance performance |
| CoCP | Certificate of Constancy of Performance, where applicable |