NGFLGöu – Flexible Flat Rubber Cable 300/500 V
Flexible flat rubber power and signal cable designed for medium mechanical stress, moving machine components, material handling equipment and large industrial machinery. Suitable for dry, damp and wet locations as well as outdoor installations involving bending in a single plane.
Product Overview
NGFLGöu is a flexible flat rubber-insulated and rubber-sheathed cable rated at 300/500 V, designed for power supply and signal transmission applications under medium mechanical stress.
The cable incorporates fine-stranded bare copper conductors with Class 5 and Class 6 construction referenced according to DIN EN 60228.
The individual cores are insulated with a rubber compound and arranged in parallel. The cores are grouped, with individual groups separated by connecting webs.
A black 5GM3 rubber outer sheath provides mechanical protection and specified flame-retardant performance.
NGFLGöu is suitable for dry, damp and wet locations, as well as outdoor installations. It is particularly intended for moving machine tool components, material handling equipment and large industrial machinery where bending occurs in one plane only.
The reference product range includes 24 cable configurations, with nominal conductor cross-sections from 1.5 mm² to 35 mm² and configurations containing between 4 and 24 cores.
Key Technical Features
Cable Construction & Technical Properties
Cable Construction
Electrical & Mechanical Properties
Flat Cable Construction
Parallel Core Arrangement
Unlike conventional round cables, NGFLGöu features a flat construction with insulated conductors arranged in parallel.
The individual cores are organised into groups, with connecting webs separating the groups where applicable.
This construction is intended for applications involving controlled bending in one plane.
Flexible Copper Conductors
The cable incorporates fine-stranded bare copper conductors with Class 5 and Class 6 construction referenced according to DIN EN 60228.
The published conductor constructions include individual wire diameters of approximately 0.16 mm, 0.21 mm and 0.41 mm, depending on the conductor cross-section.
The exact conductor class for each cable size must be confirmed in the final manufacturer specification.
Rubber Insulation & Outer Sheath
Rubber Core Insulation
Each copper conductor is insulated with a rubber compound identified as 3GI3 in the reference technical documentation.
The insulation is designed for the specified rated voltage of 300/500 V and an AC test voltage of 2 kV.
The specified maximum short-circuit temperature is +200°C for a duration not exceeding five seconds.
5GM3 Rubber Outer Sheath
The black rubber outer sheath is manufactured from a 5GM3 rubber compound.
The reference construction is intended for medium mechanical stress in dry, damp and wet locations, including outdoor applications.
Single-cable flame propagation performance is specified according to EN 60332-1-2.
Moving Machinery & Material Handling Applications
NGFLGöu is intended for flexible electrical connections to moving components of machine tools, material handling equipment and large industrial machinery.
The flat construction is suitable for installations where the cable movement and bending direction are controlled within a single plane.
Potential applications include travelling machinery, moving industrial equipment and selected material handling systems, subject to verification of mechanical loads and installation conditions.
Applications involving torsion, multidirectional bending, high tensile loads or continuous high-cycle operation require separate technical confirmation.
Typical Applications
Installation Conditions
Specified Installation Parameters
Additional Installation Considerations
Fire & Environmental Performance
Specified Properties
Additional Performance Requirements
Applicable Standards
DIN VDE 0250-809 – Reference product standard for flat rubber cable construction.
DIN EN 60228 Class 5 and 6 – Flexible and highly flexible conductors of insulated cables.
HD 308 S2 – Identification of cores in cables and flexible cords.
EN 60332-1-2 – Vertical flame propagation test for a single insulated wire or cable.
NGFLGöu 300/500 V – Cable Sizes & Technical Data
Complete reference range of flexible flat rubber power and signal cables for medium mechanical stress, including conductor construction, copper figures, flat cable dimensions, cable weights and installation characteristics.
Complete Cable Size Range
| Cable Size (mm²) | Copper Figure (kg/km) | Approx. Conductor Construction (n × mm) | Approx. Outer Dimensions (mm) | Approx. Cable Weight (kg/km) |
|---|---|---|---|---|
| 1.5 mm² Conductor Cross-Section | ||||
| 4x1.5 | 57.6 | 84 × 0.16 | 6.2 × 17.5 | 200 |
| 5x1.5 | 72.0 | 84 × 0.16 | 6.2 × 21.5 | 240 |
| 7x1.5 | 100.8 | 84 × 0.16 | 6.2 × 29.0 | 360 |
| 8x1.5 | 115.2 | 84 × 0.16 | 6.2 × 31.5 | 370 |
| 12x1.5 | 172.8 | 84 × 0.16 | 6.5 × 47.0 | 620 |
| 24x1.5 | 345.6 | 84 × 0.16 | 13.5 × 56.0 | 1010 |
| 2.5 mm² Conductor Cross-Section | ||||
| 4x2.5 | 96.0 | 140 × 0.16 | 7.5 × 21.0 | 280 |
| 5x2.5 | 120.0 | 140 × 0.16 | 7.5 × 27.0 | 400 |
| 7x2.5 | 168.0 | 140 × 0.16 | 7.5 × 35.0 | 520 |
| 8x2.5 | 192.0 | 140 × 0.16 | 7.5 × 39.0 | 550 |
| 12x2.5 | 288.0 | 140 × 0.16 | 8.0 × 56.0 | 800 |
| 24x2.5 | 576.0 | 140 × 0.16 | 17.0 × 72.5 | 1690 |
| 4 mm² Conductor Cross-Section | ||||
| 4x4 | 153.6 | 224 × 0.16 | 9.0 × 26.0 | 410 |
| 5x4 | 192.0 | 224 × 0.16 | 9.0 × 32.0 | 560 |
| 7x4 | 268.8 | 224 × 0.16 | 9.0 × 42.0 | 700 |
| 6 mm² Conductor Cross-Section | ||||
| 4x6 | 230.4 | 192 × 0.21 | 9.5 × 29.0 | 600 |
| 5x6 | 288.0 | 192 × 0.21 | 9.5 × 35.0 | 650 |
| 7x6 | 403.2 | 192 × 0.21 | 9.5 × 44.5 | 850 |
| 10 mm² Conductor Cross-Section | ||||
| 4x10 | 384.0 | 320 × 0.21 | 11.0 × 33.0 | 800 |
| 7x10 | 672.0 | 320 × 0.21 | 12.1 × 63.5 | 1350 |
| 16 mm² Conductor Cross-Section | ||||
| 4x16 | 614.4 | 512 × 0.21 | 13.0 × 38.0 | 1150 |
| 5x16 | 768.0 | 512 × 0.21 | 13.0 × 50.0 | 1450 |
| 25 mm² Conductor Cross-Section | ||||
| 4x25 | 960.0 | 800 × 0.21 | 15.0 × 49.5 | 1700 |
| 35 mm² Conductor Cross-Section | ||||
| 4x35 | 1344.0 | 280 × 0.41 | 17.0 × 55.0 | 2200 |
All 24 cable configurations, copper figures, conductor constructions, outer dimensions and cable weights are reproduced from the reference technical documentation. Copper figures are published reference metal factors and should not automatically be interpreted as measured net copper mass.
Available Core & Cross-Section Configurations
| Cross-Section (mm²) | 4 Cores | 5 Cores | 7 Cores | 8 Cores | 12 Cores | 24 Cores |
|---|---|---|---|---|---|---|
| 1.5 | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
| 2.5 | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
| 4 | ✓ | ✓ | ✓ | — | — | — |
| 6 | ✓ | ✓ | ✓ | — | — | — |
| 10 | ✓ | — | ✓ | — | — | — |
| 16 | ✓ | ✓ | — | — | — | — |
| 25 | ✓ | — | — | — | — | — |
| 35 | ✓ | — | — | — | — | — |
A check mark indicates a configuration listed in the reference datasheet, not confirmed stock availability. Other configurations are subject to separate enquiry.
Conductor Construction Overview
| Nominal Cross-Section (mm²) | Approx. Number of Wires | Approx. Wire Diameter (mm) | Materijal vodiča |
|---|---|---|---|
| 1.5 | 84 | 0.16 | Bare Copper |
| 2.5 | 140 | 0.16 | Bare Copper |
| 4 | 224 | 0.16 | Bare Copper |
| 6 | 192 | 0.21 | Bare Copper |
| 10 | 320 | 0.21 | Bare Copper |
| 16 | 512 | 0.21 | Bare Copper |
| 25 | 800 | 0.21 | Bare Copper |
| 35 | 280 | 0.41 | Bare Copper |
DIN EN 60228 Class 5 and Class 6 are referenced in the original datasheet. The exact conductor class applicable to each cross-section is not individually specified.
Electrical Characteristics
| Parameter | Reference Value |
|---|---|
| Rated Voltage U0 | 300 V |
| Rated Voltage U | 500 V |
| Rated Voltage U0/U | 300/500 V |
| AC Test Voltage | 2,000 V AC |
| Materijal vodiča | Fine-Stranded Bare Copper |
| Conductor Class | Class 5 and Class 6 Referenced |
| Conductor Standard | DIN EN 60228 |
| Nominal Cross-Section Range | 1.5–35 mm² |
| Maximum Short-Circuit Temperature | +200°C |
| Maximum Short-Circuit Duration | 5 Seconds |
| Current Carrying Capacity | Not Specified |
| DC Conductor Resistance at 20°C | Not Specified |
| Insulation Resistance | Not Specified |
| Test Voltage Duration | Not Specified |
| Capacitance | Not Specified |
| Inductance | Not Specified |
Temperature Characteristics
| Operating Condition | Minimum Temperature | Maximum Temperature |
|---|---|---|
| Fixed Installation | -40°C | +80°C |
| During Bending | -25°C | +60°C |
| Short-Circuit Temperature | Not Applicable | +200°C |
| Short-Circuit Duration | Not Applicable | 5 Seconds |
| Continuous Conductor Operating Temperature | Not Separately Specified | Not Separately Specified |
Bending Radius & Mechanical Conditions
| Parameter | Reference Value |
|---|---|
| Fixed / Single Bend | 3 × Reference Cable Dimension |
| During Bending | 5 × Reference Cable Dimension |
| Bending Direction | Single Plane Only |
| Mechanical Stress | Medium |
| Maximum Travel Speed | Not Specified |
| Maximum Tensile Load | Not Specified |
| Maximum Acceleration | Not Specified |
| Maximum Bending Cycles | Not Specified |
| Torsional Movement | Not Specified |
| Multidirectional Bending | Outside Specified Application |
Cable Construction Layers
| Layer | Component | Material / Construction |
|---|---|---|
| 1 | Conductor | Fine-Stranded Bare Copper |
| 2 | Core Insulation | Rubber Compound 3GI3, Parallel Core Arrangement |
| 3 | Outer Sheath | Black Rubber Compound 5GM3, Flame Retardant |
Core Identification & Cable Geometry
| Parameter | Reference Specification |
|---|---|
| Core Identification Standard | HD 308 S2 |
| Number of Cores | 4, 5, 7, 8, 12 or 24 |
| Core Arrangement | Parallel |
| Core Grouping | Grouped Cores with Separating Webs |
| Cable Geometry | Flat |
| Approximate First Outer Dimension | 6.2–17.0 mm |
| Approximate Second Outer Dimension | 17.5–72.5 mm |
| Outer Sheath Colour | Crna |
| Protective Earth Core Configuration | Confirm for Selected Cable Size |
Mechanical & Environmental Properties
| Property | Reference Specification | Status |
|---|---|---|
| Dry Locations | Specified Application | Suitable |
| Damp Locations | Specified Application | Suitable |
| Wet Locations | Specified Application | Suitable |
| Outdoor Installation | Specified Application | Suitable |
| Mechanical Stress | Medium | Specified |
| Single-Plane Bending | Specified Application | Suitable |
| Oil Resistance Test | Not Specified | Requires Verification |
| Ozone Resistance | Not Specified | Requires Verification |
| UV Resistance Test | Not Specified | Requires Verification |
| Permanent Water Immersion | Not Specified | Requires Verification |
| Direct Burial | Not Specified | Requires Verification |
| Continuous Drag Chain Operation | Not Specified | Requires Verification |
Fire Performance & Certification
| Property | Standard / Reference | Declared Performance |
|---|---|---|
| Single-Cable Flame Retardancy | EN 60332-1-2 | Specified |
| Bunched Cable Flame Retardancy | IEC 60332-3 Series | Not Declared |
| CPR Reaction to Fire | EN 50575 / EN 13501-6 | Not Specified |
| Low-Smoke Performance | EN IEC 61034-2 | Not Declared |
| Halogen-Free Performance | EN IEC 60754 Series | Not Declared |
| Fire-Resistant Circuit Integrity | IEC 60331 Series | Not Declared |
Installation & Application Conditions
| Područje primjene | Reference Status |
|---|---|
| Moving Machine Tool Components | Specified Application |
| Material Handling Equipment | Specified Application |
| Large Industrial Machinery | Specified Application |
| Flexible Power Connections | Specified Application |
| Flexible Signal Connections | Specified Application |
| Outdoor Industrial Installations | Specified Application |
| Crane and Hoist Cable Systems | Project-Specific Verification Required |
| Festoon Cable Systems | Project-Specific Verification Required |
| Cable Reel Systems | Not Specified |
| Elevator Travelling Cable Applications | Not Specified |
| High-Speed Continuous Movement | Not Specified |
Applicable Standards
| Standard | Područje primjene |
|---|---|
| DIN VDE 0250-809 | Flat Rubber Cable Construction |
| DIN EN 60228 | Conductors of Insulated Cables, Class 5 and Class 6 Referenced |
| HD 308 S2 | Core Identification |
| EN 60332-1-2 | Vertical Flame Propagation Test for a Single Insulated Wire or Cable |