Potraži kabel

Select a cable or enter another designation.


UNIMA CABLE | CONTROL & INSTRUMENTATION CABLES

YSLCY – Screened PVC Control Cable 300/500 V

Flexible multicore control, measurement and signal cable with fine-stranded copper conductors, PVC insulation, tinned copper wire braid and a grey PVC outer sheath with enhanced oil resistance. Designed for applications requiring protection against external electromagnetic interference.

300/500 V 0.5–25 mm² 2–50 Cores Class 5 Copper Tinned Copper Braid EMC Screening Oil Resistant PVC Insulation PVC Sheath JZ / OZ EN 60332-1-2

Product Overview

YSLCY is a flexible screened PVC control and signal cable designed for control, measurement, signalling and impulse transmission applications.

The cable incorporates fine-stranded bare copper conductors according to DIN EN 60228 Class 5, providing flexibility for installation and equipment connections.

Individual conductors are insulated with polyvinyl chloride (PVC). The assembled cable core is covered with plastic foil and an overall braid of round tinned copper wires.

The copper braid improves protection against external electromagnetic fields and signal interference, supporting reliable signal transmission in industrial control and measurement systems.

The outer sheath consists of grey PVC with enhanced oil resistance.

YSLCY is available in reference configurations ranging from 0.5 to 25 mm², with between 2 and 50 cores depending on the selected conductor cross-section.

Key Technical Features

300/500 VRadni napon
0.5–25 mm²Conductor Range
Class 5Flexible Copper
+70°CMaximum Installation Temperature

Cable Variants

YSLCY-JZ

With Protective Earth Conductor

One green/yellow protective conductor and remaining black cores with numerical identification.

Suitable for control and equipment connections requiring a protective earth conductor.

YSLCY-OZ

Without Protective Earth Conductor

Black cores with numerical identification, without a green/yellow protective conductor.

Suitable for control, signal and measurement circuits where a protective earth conductor is not required within the cable.

Colour-Coded Versions

Selected YSLCY configurations are also available with coloured cores according to HD 308 S2.

These configurations are identified with an asterisk in the technical dimensions table.

The required core identification and protective conductor arrangement must be specified when ordering.

Construction & Technical Properties

Cable Construction

Materijal vodičaBare Copper
Conductor ConstructionFine-Stranded, Flexible
Conductor ClassClass 5
Conductor StandardDIN EN 60228
Conductor Cross-Section0.5–25 mm²
Number of Cores2–50
Core InsulationPolyvinyl Chloride (PVC)
Core Identification JZBlack Numbered Cores and Green/Yellow PE
Core Identification OZBlack Numbered Cores
Colour-Coded VersionsSelected Sizes, HD 308 S2
Wrapping LayerPlastic Foil
Overall ScreenTinned Copper Wire Braid
ArmourNone
Outer SheathPVC with Enhanced Oil Resistance
Sheath ColourGrey

Electrical & Mechanical Data

Rated Voltage U0/U300/500 V
Test Voltage2000 V AC
Temperature During Bending-5°C to +70°C
Fixed Installation Temperature-30°C to +70°C
Short-Circuit Temperature+150°C
Maximum Short-Circuit Duration5 Seconds
Fixed Bending Radius10 x Cable Diameter
Radius During Bending20 x Cable Diameter
Electromagnetic ScreeningTinned Copper Braid
Oil ResistanceEnhanced
Flame Propagation TestEN 60332-1-2
Approx. Outer Diameter5.6–27.5 mm
Approx. Cable Weight45–1840 kg/km

Electromagnetic Compatibility & Screening

Tinned Copper Wire Braid

The overall tinned copper wire braid provides screening against external electromagnetic interference.

This construction is particularly relevant for control, measurement and signal circuits operating in environments containing electrical equipment and industrial machinery.

Screen coverage and transfer impedance are not specified in the reference documentation.

Industrial Signal Protection

The screened construction helps reduce the influence of external electromagnetic fields on transmitted signals.

Effective electromagnetic compatibility depends on cable routing, screen termination, grounding arrangements and the electrical characteristics of the complete installation.

Oil Resistance & Flame Performance

Enhanced Oil Resistance

The grey PVC outer sheath provides enhanced resistance to oils.

Compatibility with specific oils, chemicals, concentrations and exposure conditions must be confirmed for the intended application.

Flame Propagation Performance

The reference documentation specifies EN 60332-1-2 for vertical flame propagation testing of a single insulated wire or cable.

This test does not establish fire-resistant circuit integrity or a CPR Euroclass classification.

Typical Applications

Industrial Control Systems
Industrial Automation
Measurement Technology
Instrumentation Systems
Signal Transmission
Impulse Transmission Circuits
Machine Control Connections
Industrial Production Lines
Screened Equipment Connections
Building Automation Systems
Industrial Monitoring Systems
Control Cabinet Connections

Installation Conditions

YSLCY cables are intended for control, measurement and signal transmission installations requiring flexible conductors and overall electromagnetic screening.

The permitted temperature range during bending is -5°C to +70°C.

For fixed installations, the specified temperature range is -30°C to +70°C.

The minimum bending radius for fixed or one-time installation is 10 times the cable outer diameter.

During bending, the minimum radius is 20 times the cable outer diameter.

Suitability for outdoor installation, direct burial, permanent immersion, continuous-flex operation and drag-chain applications is not established by the reference documentation.

Applicable Standards

DIN VDE 0281 – Cable construction adapted to this reference standard.

DIN EN 60228, Class 5 – Flexible copper conductor construction.

HD 308 S2 – Core identification for selected colour-coded cable configurations.

EN 60332-1-2 – Vertical flame propagation test for a single insulated wire or cable.

Technical Note: Cable construction, dimensions, conductor stranding and weights depend on the selected configuration. The reference documentation describes the cable construction as adapted to DIN VDE 0281, which does not independently establish VDE certification. CPR classification, screen coverage, transfer impedance, UV resistance and continuous-flex service life are not specified. Final technical characteristics and conformity documentation must be confirmed for the supplied product.
UNIMA CABLE | TECHNICAL DIMENSIONS

YSLCY – Cable Sizes & Technical Data

Complete reference range of flexible screened PVC control and signal cables rated 300/500 V, including conductor stranding, copper content, cable dimensions, approximate weights, electrical characteristics and installation parameters.

54Reference Configurations
0.5–25 mm²Conductor Cross-Section
2–50Number of Cores
45–1840 kg/kmCable Weight

Available Cable Sizes & Construction Data

Cable Size (mm²) Number of Cores Copper Content (kg/km) Approx. Conductor Stranding Approx. Outer Diameter (mm) Approx. Cable Weight (kg/km)
YSLCY – 0.5 mm²
2x0.5234.616 x 0.215.645
3x0.5341.316 x 0.215.955
4x0.5447.016 x 0.216.473
5x0.5554.716 x 0.217.091
12x0.51299.816 x 0.219.8208
25x0.525202.616 x 0.2113.7354
YSLCY – 0.75 mm²
2x0.75241.324 x 0.216.256
3x0.75349.924 x 0.216.570
4x0.75458.624 x 0.217.096
5x0.75569.124 x 0.217.8157
7x0.75785.424 x 0.218.4168
10x0.7510116.224 x 0.2110.4217
12x0.7512132.524 x 0.2110.9231
18x0.7518202.624 x 0.2112.8314
25x0.7525268.824 x 0.2115.2434
34x0.7534332.224 x 0.2117.1529
YSLCY – 1 mm²
2x1249.032 x 0.216.583
3x1359.532 x 0.216.7111
4x1471.032 x 0.217.4131
5x1584.532 x 0.218.1155
7x17107.532 x 0.218.8190
12x112177.632 x 0.2111.5286
18x118257.332 x 0.2113.8393
25x125339.832 x 0.2116.0658
34x134439.732 x 0.2118.4759
50x150644.232 x 0.2122.0994
YSLCY – 1.5 mm²
2x1.5 *262.430 x 0.267.197
3x1.5 *378.730 x 0.267.6124
4x1.5 *496.030 x 0.268.2166
5x1.5 *5114.230 x 0.269.0192
7x1.57147.830 x 0.269.8245
12x1.512257.330 x 0.2613.0365
18x1.518358.130 x 0.2615.5556
25x1.525508.830 x 0.2618.0737
27x1.527537.630 x 0.2620.0750
34x1.534658.230 x 0.2620.9966
50x1.550961.030 x 0.2624.81342
YSLCY – 2.5 mm²
2x2.5288.350 x 0.268.5161
3x2.5 *3113.350 x 0.269.0187
4x2.54141.150 x 0.269.9241
5x2.55169.050 x 0.2611.0274
7x2.57242.950 x 0.2612.0344
12x2.512391.750 x 0.2615.9407
YSLCY – 4 mm²
4x44238.156 x 0.3111.6307
5x45276.550 x 0.3112.8370
YSLCY – 6 mm²
2x62163.284 x 0.3112.5180
4x64329.384 x 0.3114.0402
5x65386.984 x 0.3115.5506
YSLCY – 10 mm²
4x10 *4513.680 x 0.4117.2747
5x105609.680 x 0.4119.3861
YSLCY – 16 mm²
4x164768.0128 x 0.4120.01041
5x165921.6128 x 0.4122.21289
YSLCY – 25 mm²
4x2541228.8200 x 0.4124.71460
5x2551468.8200 x 0.4127.51840

* Also available with colour-coded cores according to HD 308 S2.

Cable sizes are expressed as the number of cores multiplied by the nominal conductor cross-section in mm². The table uses generic size notation as listed in the reference documentation. The required JZ, OZ or colour-coded version must be specified when ordering.

Conductor stranding is expressed as the approximate number of individual wires multiplied by their nominal diameter in millimetres. Copper content values are reference figures and must not be interpreted as independently verified recoverable copper mass.

Conductor Construction by Cross-Section

Nominal Cross-Section (mm²) Approx. Conductor Stranding Conductor Class Reference Configurations
0.516 x 0.21 mmClass 56
0.7524 x 0.21 mmClass 510
132 x 0.21 mmClass 510
1.530 x 0.26 mmClass 511
2.550 x 0.26 mmClass 56
456 x 0.31 / 50 x 0.31 mmClass 52
684 x 0.31 mmClass 53
1080 x 0.41 mmClass 52
16128 x 0.41 mmClass 52
25200 x 0.41 mmClass 52

The reference documentation specifies different conductor stranding for 4x4 mm² and 5x4 mm². These values are retained as published and must be confirmed for the supplied cable.

Electrical Characteristics

ParameterReference Value
Rated Voltage U0/U300/500 V
Test Voltage2000 V AC
Materijal vodičaBare Copper
Conductor ConstructionFine-Stranded, Flexible
Conductor ClassClass 5
Conductor StandardDIN EN 60228
Core InsulationPVC
Overall ScreenTinned Copper Wire Braid
Screen CoverageNot Specified
Transfer ImpedanceNot Specified

Temperature Characteristics

Installation / Operating Condition Minimum Temperature Maximum Temperature
During Bending-5°C+70°C
Fixed Installation-30°C+70°C
Short-Circuit ConditionNot Specified+150°C

Maximum short-circuit duration: 5 seconds.

Minimum Cable Bending Radius

Cable Size (mm²) Outer Diameter (mm) Fixed Installation 10 x D (mm) During Bending 20 x D (mm)
0.5 mm²
2x0.55.656112
3x0.55.959118
4x0.56.464128
5x0.57.070140
12x0.59.898196
25x0.513.7137274
0.75 mm²
2x0.756.262124
3x0.756.565130
4x0.757.070140
5x0.757.878156
7x0.758.484168
10x0.7510.4104208
12x0.7510.9109218
18x0.7512.8128256
25x0.7515.2152304
34x0.7517.1171342
1 mm²
2x16.565130
3x16.767134
4x17.474148
5x18.181162
7x18.888176
12x111.5115230
18x113.8138276
25x116.0160320
34x118.4184368
50x122.0220440
1.5 mm²
2x1.5 *7.171142
3x1.5 *7.676152
4x1.5 *8.282164
5x1.5 *9.090180
7x1.59.898196
12x1.513.0130260
18x1.515.5155310
25x1.518.0180360
27x1.520.0200400
34x1.520.9209418
50x1.524.8248496
2.5 mm²
2x2.58.585170
3x2.5 *9.090180
4x2.59.999198
5x2.511.0110220
7x2.512.0120240
12x2.515.9159318
4 mm²
4x411.6116232
5x412.8128256
6 mm²
2x612.5125250
4x614.0140280
5x615.5155310
10 mm²
4x10 *17.2172344
5x1019.3193386
16 mm²
4x1620.0200400
5x1622.2222444
25 mm²
4x2524.7247494
5x2527.5275550

Minimum bending radii are calculated from the approximate outer diameters and the specified bending factors of 10 x D for fixed or one-time installation and 20 x D during bending. Actual installation limits must be confirmed using the supplied cable dimensions.

Cable Construction Layers

Layer Component Material / Construction
1ConductorFine-Stranded Bare Copper, Class 5
2Core InsulationPolyvinyl Chloride (PVC)
3Wrapping LayerPlastic Foil
4Overall ScreenBraid of Round Tinned Copper Wires
5Outer SheathGrey PVC with Enhanced Oil Resistance

Core Identification & Cable Variants

Version Core Identification Protective Earth
YSLCY-JZBlack Numbered Cores and Green/Yellow CoreYes
YSLCY-OZBlack Numbered CoresNo
Colour-Coded VersionAccording to HD 308 S2Depending on Configuration

Colour-Coded Cable Configurations

Cable Size (mm²) Additional Core Identification Option
2x1.5Coloured Cores According to HD 308 S2
3x1.5Coloured Cores According to HD 308 S2
4x1.5Coloured Cores According to HD 308 S2
5x1.5Coloured Cores According to HD 308 S2
3x2.5Coloured Cores According to HD 308 S2
4x10Coloured Cores According to HD 308 S2

Mechanical & Environmental Characteristics

ParameterReference Value
Outer Sheath MaterialPVC
Outer Sheath ColourGrey
Oil ResistanceEnhanced
Oil Resistance Test StandardNot Specified
Electromagnetic ScreeningOverall Tinned Copper Wire Braid
Flame Propagation TestEN 60332-1-2
Outdoor InstallationNot Specified
UV ResistanceNot Specified
Direct BurialNot Specified
Continuous-Flex ApplicationsNot Specified
Maximum Tensile LoadNot Specified
CPR ClassificationNot Specified

Applicable Standards

StandardReference Application
DIN VDE 0281Adapted Cable Construction
DIN EN 60228Flexible Copper Conductors, Class 5
HD 308 S2Core Identification for Colour-Coded Versions
EN 60332-1-2Vertical Flame Propagation Test on a Single Cable
Technical Note: All cable dimensions, conductor stranding, copper content and cable weights are indicative reference values. Reference configurations do not constitute a declaration of stock availability. JZ, OZ and colour-coded versions must be confirmed individually. Cable construction adapted to DIN VDE 0281 does not independently establish VDE certification.
Data Verification: The conductor stranding values of 56 x 0.31 mm for 4x4 mm² and 50 x 0.31 mm for 5x4 mm² are reproduced from the reference documentation without modification. Bending radii are calculated values. Current-carrying capacity, conductor resistance, screen coverage, transfer impedance, CPR classification and detailed environmental performance must be confirmed for the supplied product.

Technical Documentation

Technical Data Sheet

EU declaration of conformity

Core Identification

Send Us email - RFQ


KOLEKCIJA KABELA UNIMA

Istražite našu ponudu kabela

Otkrijte vrste kabela, tehničke specifikacije i rješenja za svoje projekte.

96 Cable Types Available