H05VV5-F – Oil-Resistant PVC Control Cable 300/500 V

Flexible multicore control and signal cable with fine-stranded copper conductors, PVC core insulation and an oil-resistant grey PVC outer sheath. Designed for industrial machinery, production lines, measurement systems and control installations.

300/500 V 0.75–6 mm² 2–50 Cores Class 5 Copper Fleksibilni Oil Resistant PVC Insulation PVC Sheath EN 60332-1-2 DIN VDE 0281

Product Overview

H05VV5-F is a flexible, oil-resistant PVC control cable intended for connection and interconnection in control, measurement and signalling systems.

The cable incorporates fine-stranded bare copper conductors according to DIN EN 60228 Class 5, providing flexibility for fixed installations and applications involving bending within the specified limits.

Individual conductors are insulated with PVC compound YI2. The overall protection consists of a grey PVC outer sheath made from compound YM2.

The oil-resistant construction makes the cable suitable for industrial machinery, manufacturing facilities, production lines and equipment control systems where exposure to oils may occur.

H05VV5-F is intended for dry and damp indoor environments under low to medium mechanical stress. It is not intended for outdoor installation.

The reference product range includes 40 cable configurations with nominal conductor cross-sections from 0.75 to 6 mm² and between 2 and 50 cores.

Key Technical Features

300/500 VRadni napon
0.75–6 mm²Conductor Range
Class 5Flexible Copper Conductor
+70°CMaximum Operating Temperature

Cable Designation

HHarmonised Cable Designation
05Rated Voltage 300/500 V
VPVC Core Insulation
V5Oil-Resistant PVC Outer Sheath
FFlexible Fine-Stranded Conductor

Cable Variants

H05VV5-F – G Versions

With Protective Earth Conductor

Multicore construction incorporating a green/yellow protective conductor. The remaining cores are black with numerical identification.

Reference configurations include 3 to 50 cores, depending on the conductor cross-section.

H05VV5-F – X Versions

Without Protective Earth Conductor

Two-core configurations without a green/yellow protective conductor.

Reference sizes include 2x0.75 mm², 2x1 mm² and 2x1.5 mm².

Construction & Technical Properties

Cable Construction

Materijal vodičaBare Copper
Conductor ConstructionFine-Stranded, Flexible
Conductor ClassClass 5
Conductor StandardDIN EN 60228
Conductor Cross-Section0.75–6 mm²
Number of Cores2–50
Core InsulationPolyvinyl Chloride (PVC)
Insulation CompoundYI2
Core IdentificationBlack Cores with Numbers
Protective ConductorGreen/Yellow in G Versions
ScreenNone
ArmourNone
Outer SheathOil-Resistant PVC
Sheath CompoundYM2
Sheath ColourGrey

Electrical & Mechanical Data

Rated Voltage U0/U300/500 V
Test Voltage2000 V AC
Temperature During Bending-5°C to +70°C
Fixed Installation Temperature-40°C to +70°C
Short-Circuit Temperature+150°C
Fixed Bending Radius12.5 x Cable Diameter
Radius During Bending15 x Cable Diameter
Oil ResistanceEN 60811-2-1
Flame Propagation TestEN 60332-1-2
Mechanical StressLow to Medium
Dry Indoor InstallationSuitable
Damp Indoor InstallationSuitable
Outdoor InstallationNot Suitable
Outer Diameter6.1–29.0 mm
Approx. Cable Weight55–1584 kg/km

Oil Resistance & Flame Performance

Oil-Resistant Construction

The special PVC outer sheath provides oil resistance according to the EN 60811-2-1 test reference listed in the technical documentation.

The cable is suitable for indoor industrial environments where contact with oils may occur. Compatibility with specific oils, chemicals and exposure conditions must be confirmed.

Flame Propagation Performance

The reference documentation lists EN 60332-1-2 for flame propagation performance of a single insulated wire or cable.

This test does not establish fire-resistant circuit integrity or a CPR Euroclass classification.

Typical Applications

Industrial Control Systems
Production Lines
Machine Control Connections
Industrial Automation
Measurement Technology
Signal Transmission
Impulse and Control Circuits
Industrial Equipment Connections
Manufacturing Facilities
Indoor Building Control Systems

Installation Conditions

H05VV5-F is designed for installation in dry and damp indoor environments under low to medium mechanical stress.

For fixed or one-time installation, the minimum bending radius is 12.5 times the cable outer diameter.

During bending, the minimum radius is 15 times the cable outer diameter.

The permitted temperature range during bending is -5°C to +70°C. For fixed installations, the specified range is -40°C to +70°C.

The cable is not intended for outdoor installation. Suitability for continuous movement, drag chains, torsional applications or direct burial is not established by the reference documentation.

Applicable Standards

DIN VDE 0281-13 – Reference cable construction standard.

DIN EN 60228, Class 5 – Flexible copper conductor construction.

EN 60811-2-1 – Reference test standard for oil resistance.

EN 60332-1-2 – Vertical flame propagation test for a single insulated wire or cable.

Selected cable configurations are identified in the reference documentation as adapted to the DIN VDE standard. Their exact conformity and approval status must be confirmed before ordering.

Technical Note: Cable construction, dimensions, conductor stranding and weights depend on the selected configuration. The cable is intended for indoor installation and is not suitable for outdoor use. CPR classification, halogen-free performance, continuous-flex service life and maximum tensile load are not specified in the reference documentation. The applicable standard editions and conformity status must be confirmed for the supplied product.
UNIMA CABLE | TECHNICAL DIMENSIONS

H05VV5-F – Cable Sizes & Technical Data

Complete reference range of flexible oil-resistant PVC control cables rated 300/500 V, including conductor construction, copper weight, cable dimensions, approximate cable weights and installation characteristics.

40Reference Configurations
0.75–6 mm²Conductor Cross-Section
2–50Number of Cores
55–1584 kg/kmCable Weight

Available Cable Sizes & Construction Data

Cable Size (mm²) Number of Cores Protective Earth Copper Weight (kg/km) Approx. Conductor Stranding Outer Diameter (mm) Approx. Cable Weight (kg/km)
H05VV5-F – 0.75 mm²
2X0.752No14.424 x 0.216.155
3G0.753Yes21.624 x 0.216.666
4G0.754Yes28.824 x 0.217.383
5G0.755Yes36.024 x 0.218.1102
7G0.757Yes50.424 x 0.218.9129
12G0.7512Yes86.424 x 0.2111.9227
18G0.7518Yes129.624 x 0.2114.2329
25G0.7525Yes180.024 x 0.2116.5449
34G0.7534Yes244.824 x 0.2119.2609
50G0.75 *50Yes360.024 x 0.2123.2893
H05VV5-F – 1 mm²
2X12No19.232 x 0.216.563
3G13Yes28.832 x 0.216.977
4G14Yes38.432 x 0.217.797
5G15Yes48.032 x 0.218.5120
7G17Yes67.232 x 0.219.4152
12G112Yes115.232 x 0.2112.6268
18G118Yes172.832 x 0.2115.0389
25G125Yes240.032 x 0.2117.5533
34G134Yes326.432 x 0.2120.4721
H05VV5-F – 1.5 mm²
2X1.5 *2No28.830 x 0.267.690
3G1.53Yes43.230 x 0.268.2110
4G1.54Yes57.630 x 0.269.1138
5G1.55Yes72.030 x 0.2610.1172
7G1.57Yes100.830 x 0.2611.1219
12G1.512Yes172.830 x 0.2614.9388
18G1.518Yes259.230 x 0.2617.9565
25G1.525Yes360.030 x 0.2620.9775
34G1.534Yes489.630 x 0.2624.31051
H05VV5-F – 2.5 mm²
3G2.53Yes72.050 x 0.269.7162
4G2.54Yes96.050 x 0.2610.7205
5G2.55Yes120.050 x 0.2612.0256
7G2.57Yes168.050 x 0.2613.2328
12G2.512Yes288.050 x 0.2617.8581
18G2.518Yes432.050 x 0.2621.3848
34G2.534Yes816.050 x 0.2629.01584
H05VV5-F – 4 mm²
4G4 *4Yes153.656 x 0.3111.6280
5G4 *5Yes192.056 x 0.3114.1340
7G4 *7Yes268.856 x 0.3115.1445
H05VV5-F – 6 mm²
4G6 *4Yes230.484 x 0.3116.8450
5G6 *5Yes288.084 x 0.3118.4550

G = Cable incorporating a green/yellow protective earth conductor.
X = Cable without a green/yellow protective earth conductor.
* = Configuration identified in the reference documentation as adapted to the DIN VDE standard.

Conductor stranding is expressed as the approximate number of individual wires multiplied by their nominal diameter in millimetres. Copper weight values are reproduced from the reference documentation and must not be interpreted as independently verified recoverable copper content.

Conductor Construction by Cross-Section

Nominal Cross-Section (mm²) Approx. Conductor Stranding Conductor Class Number of Reference Sizes
0.7524 x 0.21 mmClass 510
132 x 0.21 mmClass 59
1.530 x 0.26 mmClass 59
2.550 x 0.26 mmClass 57
456 x 0.31 mmClass 53
684 x 0.31 mmClass 52

Electrical Characteristics

Parameter Reference Value
Rated Voltage U0/U300/500 V
Test Voltage2000 V AC
Materijal vodičaBare Copper
Conductor ConstructionFlexible, Fine-Stranded
Conductor ClassClass 5
Conductor StandardDIN EN 60228
Core InsulationPVC YI2
Protective Earth ConductorIncluded in G Versions

Temperature Characteristics

Installation / Operating Condition Minimum Temperature Maximum Temperature
During Bending-5°C+70°C
Fixed Installation-40°C+70°C
Short-Circuit ConditionNot Specified+150°C

Minimum Bending Radius

Cable Size (mm²) Outer Diameter (mm) Fixed / One-Time Installation 12.5 x D (mm) During Bending 15 x D (mm)
0.75 mm²
2X0.756.176.2591.5
3G0.756.682.599
4G0.757.391.25109.5
5G0.758.1101.25121.5
7G0.758.9111.25133.5
12G0.7511.9148.75178.5
18G0.7514.2177.5213
25G0.7516.5206.25247.5
34G0.7519.2240288
50G0.75 *23.2290348
1 mm²
2X16.581.2597.5
3G16.986.25103.5
4G17.796.25115.5
5G18.5106.25127.5
7G19.4117.5141
12G112.6157.5189
18G115.0187.5225
25G117.5218.75262.5
34G120.4255306
1.5 mm²
2X1.5 *7.695114
3G1.58.2102.5123
4G1.59.1113.75136.5
5G1.510.1126.25151.5
7G1.511.1138.75166.5
12G1.514.9186.25223.5
18G1.517.9223.75268.5
25G1.520.9261.25313.5
34G1.524.3303.75364.5
2.5 mm²
3G2.59.7121.25145.5
4G2.510.7133.75160.5
5G2.512.0150180
7G2.513.2165198
12G2.517.8222.5267
18G2.521.3266.25319.5
34G2.529.0362.5435
4 mm²
4G4 *11.6145174
5G4 *14.1176.25211.5
7G4 *15.1188.75226.5
6 mm²
4G6 *16.8210252
5G6 *18.4230276

Bending radii are calculated using the listed cable outer diameters and the specified factors of 12.5 x D for fixed or one-time installation and 15 x D during bending. These values do not establish suitability for continuous-flex applications.

Mechanical & Environmental Characteristics

Parameter Reference Value
Outer Sheath MaterialPVC YM2
Outer Sheath ColourGrey
Oil ResistanceEN 60811-2-1
Flame Propagation TestEN 60332-1-2
Mechanical StressLow to Medium
Dry Indoor EnvironmentsSuitable
Damp Indoor EnvironmentsSuitable
Outdoor InstallationNot Suitable
Direct BurialNot Specified
Continuous-Flex ApplicationsNot Specified
UV ResistanceNot Specified
CPR ClassificationNot Specified

Cable Construction Layers

Layer Component Material / Construction
1ConductorFine-Stranded Bare Copper, Class 5
2Core InsulationPVC Compound YI2
3Outer SheathOil-Resistant Grey PVC Compound YM2

Core Identification

Core Type Identification
Protective Earth ConductorGreen/Yellow, G Versions
Remaining ConductorsBlack with Numerical Marking
X VersionsWithout Green/Yellow Protective Earth Conductor

Applicable Standards

Standard Reference Application
DIN VDE 0281-13Reference Cable Construction Standard
DIN EN 60228Flexible Copper Conductors, Class 5
EN 60811-2-1Reference Oil Resistance Test Standard
EN 60332-1-2Vertical Flame Propagation Test on a Single Cable

Special Configurations

Cable Size Reference Standard Status
50G0.75Adapted to DIN VDE Standard
2X1.5Adapted to DIN VDE Standard
4G4Adapted to DIN VDE Standard
5G4Adapted to DIN VDE Standard
7G4Adapted to DIN VDE Standard
4G6Adapted to DIN VDE Standard
5G6Adapted to DIN VDE Standard
Technical Note: All cable dimensions, conductor stranding, copper weight and total cable weight values are indicative. Reference configurations do not constitute a declaration of stock availability. Configurations marked with an asterisk are described as adapted to the DIN VDE standard and require individual confirmation of conformity and approval status.
Data Verification: Bending radii are calculated from the listed cable outer diameters. Current-carrying capacity, conductor resistance, voltage drop, maximum tensile load, short-circuit duration and CPR classification are not specified in the reference documentation. Applicable standard editions, actual conductor construction and final technical specifications must be confirmed for the supplied product.

Technical Documentation

Technical Data Sheet

EU declaration of conformity

Core Identification

Send Us email - RFQ


KOLEKCIJA KABELA UNIMA

Istražite našu ponudu kabela

Otkrijte vrste kabela, tehničke specifikacije i rješenja za svoje projekte.

96 Cable Types Available