H05VV5-F – Oil-Resistant PVC Control Cable 300/500 V
Flexible multicore control and signal cable with fine-stranded copper conductors, PVC core insulation and an oil-resistant grey PVC outer sheath. Designed for industrial machinery, production lines, measurement systems and control installations.
Product Overview
H05VV5-F is a flexible, oil-resistant PVC control cable intended for connection and interconnection in control, measurement and signalling systems.
The cable incorporates fine-stranded bare copper conductors according to DIN EN 60228 Class 5, providing flexibility for fixed installations and applications involving bending within the specified limits.
Individual conductors are insulated with PVC compound YI2. The overall protection consists of a grey PVC outer sheath made from compound YM2.
The oil-resistant construction makes the cable suitable for industrial machinery, manufacturing facilities, production lines and equipment control systems where exposure to oils may occur.
H05VV5-F is intended for dry and damp indoor environments under low to medium mechanical stress. It is not intended for outdoor installation.
The reference product range includes 40 cable configurations with nominal conductor cross-sections from 0.75 to 6 mm² and between 2 and 50 cores.
Key Technical Features
Cable Designation
Cable Variants
H05VV5-F – G Versions
With Protective Earth Conductor
Multicore construction incorporating a green/yellow protective conductor. The remaining cores are black with numerical identification.
Reference configurations include 3 to 50 cores, depending on the conductor cross-section.
H05VV5-F – X Versions
Without Protective Earth Conductor
Two-core configurations without a green/yellow protective conductor.
Reference sizes include 2x0.75 mm², 2x1 mm² and 2x1.5 mm².
Construction & Technical Properties
Cable Construction
Electrical & Mechanical Data
Oil Resistance & Flame Performance
Oil-Resistant Construction
The special PVC outer sheath provides oil resistance according to the EN 60811-2-1 test reference listed in the technical documentation.
The cable is suitable for indoor industrial environments where contact with oils may occur. Compatibility with specific oils, chemicals and exposure conditions must be confirmed.
Flame Propagation Performance
The reference documentation lists EN 60332-1-2 for flame propagation performance of a single insulated wire or cable.
This test does not establish fire-resistant circuit integrity or a CPR Euroclass classification.
Typical Applications
Installation Conditions
H05VV5-F is designed for installation in dry and damp indoor environments under low to medium mechanical stress.
For fixed or one-time installation, the minimum bending radius is 12.5 times the cable outer diameter.
During bending, the minimum radius is 15 times the cable outer diameter.
The permitted temperature range during bending is -5°C to +70°C. For fixed installations, the specified range is -40°C to +70°C.
The cable is not intended for outdoor installation. Suitability for continuous movement, drag chains, torsional applications or direct burial is not established by the reference documentation.
Applicable Standards
DIN VDE 0281-13 – Reference cable construction standard.
DIN EN 60228, Class 5 – Flexible copper conductor construction.
EN 60811-2-1 – Reference test standard for oil resistance.
EN 60332-1-2 – Vertical flame propagation test for a single insulated wire or cable.
Selected cable configurations are identified in the reference documentation as adapted to the DIN VDE standard. Their exact conformity and approval status must be confirmed before ordering.
H05VV5-F – Cable Sizes & Technical Data
Complete reference range of flexible oil-resistant PVC control cables rated 300/500 V, including conductor construction, copper weight, cable dimensions, approximate cable weights and installation characteristics.
Available Cable Sizes & Construction Data
| Cable Size (mm²) | Number of Cores | Protective Earth | Copper Weight (kg/km) | Approx. Conductor Stranding | Outer Diameter (mm) | Approx. Cable Weight (kg/km) |
|---|---|---|---|---|---|---|
| H05VV5-F – 0.75 mm² | ||||||
| 2X0.75 | 2 | No | 14.4 | 24 x 0.21 | 6.1 | 55 |
| 3G0.75 | 3 | Yes | 21.6 | 24 x 0.21 | 6.6 | 66 |
| 4G0.75 | 4 | Yes | 28.8 | 24 x 0.21 | 7.3 | 83 |
| 5G0.75 | 5 | Yes | 36.0 | 24 x 0.21 | 8.1 | 102 |
| 7G0.75 | 7 | Yes | 50.4 | 24 x 0.21 | 8.9 | 129 |
| 12G0.75 | 12 | Yes | 86.4 | 24 x 0.21 | 11.9 | 227 |
| 18G0.75 | 18 | Yes | 129.6 | 24 x 0.21 | 14.2 | 329 |
| 25G0.75 | 25 | Yes | 180.0 | 24 x 0.21 | 16.5 | 449 |
| 34G0.75 | 34 | Yes | 244.8 | 24 x 0.21 | 19.2 | 609 |
| 50G0.75 * | 50 | Yes | 360.0 | 24 x 0.21 | 23.2 | 893 |
| H05VV5-F – 1 mm² | ||||||
| 2X1 | 2 | No | 19.2 | 32 x 0.21 | 6.5 | 63 |
| 3G1 | 3 | Yes | 28.8 | 32 x 0.21 | 6.9 | 77 |
| 4G1 | 4 | Yes | 38.4 | 32 x 0.21 | 7.7 | 97 |
| 5G1 | 5 | Yes | 48.0 | 32 x 0.21 | 8.5 | 120 |
| 7G1 | 7 | Yes | 67.2 | 32 x 0.21 | 9.4 | 152 |
| 12G1 | 12 | Yes | 115.2 | 32 x 0.21 | 12.6 | 268 |
| 18G1 | 18 | Yes | 172.8 | 32 x 0.21 | 15.0 | 389 |
| 25G1 | 25 | Yes | 240.0 | 32 x 0.21 | 17.5 | 533 |
| 34G1 | 34 | Yes | 326.4 | 32 x 0.21 | 20.4 | 721 |
| H05VV5-F – 1.5 mm² | ||||||
| 2X1.5 * | 2 | No | 28.8 | 30 x 0.26 | 7.6 | 90 |
| 3G1.5 | 3 | Yes | 43.2 | 30 x 0.26 | 8.2 | 110 |
| 4G1.5 | 4 | Yes | 57.6 | 30 x 0.26 | 9.1 | 138 |
| 5G1.5 | 5 | Yes | 72.0 | 30 x 0.26 | 10.1 | 172 |
| 7G1.5 | 7 | Yes | 100.8 | 30 x 0.26 | 11.1 | 219 |
| 12G1.5 | 12 | Yes | 172.8 | 30 x 0.26 | 14.9 | 388 |
| 18G1.5 | 18 | Yes | 259.2 | 30 x 0.26 | 17.9 | 565 |
| 25G1.5 | 25 | Yes | 360.0 | 30 x 0.26 | 20.9 | 775 |
| 34G1.5 | 34 | Yes | 489.6 | 30 x 0.26 | 24.3 | 1051 |
| H05VV5-F – 2.5 mm² | ||||||
| 3G2.5 | 3 | Yes | 72.0 | 50 x 0.26 | 9.7 | 162 |
| 4G2.5 | 4 | Yes | 96.0 | 50 x 0.26 | 10.7 | 205 |
| 5G2.5 | 5 | Yes | 120.0 | 50 x 0.26 | 12.0 | 256 |
| 7G2.5 | 7 | Yes | 168.0 | 50 x 0.26 | 13.2 | 328 |
| 12G2.5 | 12 | Yes | 288.0 | 50 x 0.26 | 17.8 | 581 |
| 18G2.5 | 18 | Yes | 432.0 | 50 x 0.26 | 21.3 | 848 |
| 34G2.5 | 34 | Yes | 816.0 | 50 x 0.26 | 29.0 | 1584 |
| H05VV5-F – 4 mm² | ||||||
| 4G4 * | 4 | Yes | 153.6 | 56 x 0.31 | 11.6 | 280 |
| 5G4 * | 5 | Yes | 192.0 | 56 x 0.31 | 14.1 | 340 |
| 7G4 * | 7 | Yes | 268.8 | 56 x 0.31 | 15.1 | 445 |
| H05VV5-F – 6 mm² | ||||||
| 4G6 * | 4 | Yes | 230.4 | 84 x 0.31 | 16.8 | 450 |
| 5G6 * | 5 | Yes | 288.0 | 84 x 0.31 | 18.4 | 550 |
G = Cable incorporating a green/yellow protective earth conductor.
X = Cable without a green/yellow protective earth conductor.
* = Configuration identified in the reference documentation as adapted to the DIN VDE standard.
Conductor stranding is expressed as the approximate number of individual wires multiplied by their nominal diameter in millimetres. Copper weight values are reproduced from the reference documentation and must not be interpreted as independently verified recoverable copper content.
Conductor Construction by Cross-Section
| Nominal Cross-Section (mm²) | Approx. Conductor Stranding | Conductor Class | Number of Reference Sizes |
|---|---|---|---|
| 0.75 | 24 x 0.21 mm | Class 5 | 10 |
| 1 | 32 x 0.21 mm | Class 5 | 9 |
| 1.5 | 30 x 0.26 mm | Class 5 | 9 |
| 2.5 | 50 x 0.26 mm | Class 5 | 7 |
| 4 | 56 x 0.31 mm | Class 5 | 3 |
| 6 | 84 x 0.31 mm | Class 5 | 2 |
Electrical Characteristics
| Parameter | Reference Value |
|---|---|
| Rated Voltage U0/U | 300/500 V |
| Test Voltage | 2000 V AC |
| Materijal vodiča | Bare Copper |
| Conductor Construction | Flexible, Fine-Stranded |
| Conductor Class | Class 5 |
| Conductor Standard | DIN EN 60228 |
| Core Insulation | PVC YI2 |
| Protective Earth Conductor | Included in G Versions |
Temperature Characteristics
| Installation / Operating Condition | Minimum Temperature | Maximum Temperature |
|---|---|---|
| During Bending | -5°C | +70°C |
| Fixed Installation | -40°C | +70°C |
| Short-Circuit Condition | Not Specified | +150°C |
Minimum Bending Radius
| Cable Size (mm²) | Outer Diameter (mm) | Fixed / One-Time Installation 12.5 x D (mm) | During Bending 15 x D (mm) |
|---|---|---|---|
| 0.75 mm² | |||
| 2X0.75 | 6.1 | 76.25 | 91.5 |
| 3G0.75 | 6.6 | 82.5 | 99 |
| 4G0.75 | 7.3 | 91.25 | 109.5 |
| 5G0.75 | 8.1 | 101.25 | 121.5 |
| 7G0.75 | 8.9 | 111.25 | 133.5 |
| 12G0.75 | 11.9 | 148.75 | 178.5 |
| 18G0.75 | 14.2 | 177.5 | 213 |
| 25G0.75 | 16.5 | 206.25 | 247.5 |
| 34G0.75 | 19.2 | 240 | 288 |
| 50G0.75 * | 23.2 | 290 | 348 |
| 1 mm² | |||
| 2X1 | 6.5 | 81.25 | 97.5 |
| 3G1 | 6.9 | 86.25 | 103.5 |
| 4G1 | 7.7 | 96.25 | 115.5 |
| 5G1 | 8.5 | 106.25 | 127.5 |
| 7G1 | 9.4 | 117.5 | 141 |
| 12G1 | 12.6 | 157.5 | 189 |
| 18G1 | 15.0 | 187.5 | 225 |
| 25G1 | 17.5 | 218.75 | 262.5 |
| 34G1 | 20.4 | 255 | 306 |
| 1.5 mm² | |||
| 2X1.5 * | 7.6 | 95 | 114 |
| 3G1.5 | 8.2 | 102.5 | 123 |
| 4G1.5 | 9.1 | 113.75 | 136.5 |
| 5G1.5 | 10.1 | 126.25 | 151.5 |
| 7G1.5 | 11.1 | 138.75 | 166.5 |
| 12G1.5 | 14.9 | 186.25 | 223.5 |
| 18G1.5 | 17.9 | 223.75 | 268.5 |
| 25G1.5 | 20.9 | 261.25 | 313.5 |
| 34G1.5 | 24.3 | 303.75 | 364.5 |
| 2.5 mm² | |||
| 3G2.5 | 9.7 | 121.25 | 145.5 |
| 4G2.5 | 10.7 | 133.75 | 160.5 |
| 5G2.5 | 12.0 | 150 | 180 |
| 7G2.5 | 13.2 | 165 | 198 |
| 12G2.5 | 17.8 | 222.5 | 267 |
| 18G2.5 | 21.3 | 266.25 | 319.5 |
| 34G2.5 | 29.0 | 362.5 | 435 |
| 4 mm² | |||
| 4G4 * | 11.6 | 145 | 174 |
| 5G4 * | 14.1 | 176.25 | 211.5 |
| 7G4 * | 15.1 | 188.75 | 226.5 |
| 6 mm² | |||
| 4G6 * | 16.8 | 210 | 252 |
| 5G6 * | 18.4 | 230 | 276 |
Bending radii are calculated using the listed cable outer diameters and the specified factors of 12.5 x D for fixed or one-time installation and 15 x D during bending. These values do not establish suitability for continuous-flex applications.
Mechanical & Environmental Characteristics
| Parameter | Reference Value |
|---|---|
| Outer Sheath Material | PVC YM2 |
| Outer Sheath Colour | Grey |
| Oil Resistance | EN 60811-2-1 |
| Flame Propagation Test | EN 60332-1-2 |
| Mechanical Stress | Low to Medium |
| Dry Indoor Environments | Suitable |
| Damp Indoor Environments | Suitable |
| Outdoor Installation | Not Suitable |
| Direct Burial | Not Specified |
| Continuous-Flex Applications | Not Specified |
| UV Resistance | Not Specified |
| CPR Classification | Not Specified |
Cable Construction Layers
| Layer | Component | Material / Construction |
|---|---|---|
| 1 | Conductor | Fine-Stranded Bare Copper, Class 5 |
| 2 | Core Insulation | PVC Compound YI2 |
| 3 | Outer Sheath | Oil-Resistant Grey PVC Compound YM2 |
Core Identification
| Core Type | Identification |
|---|---|
| Protective Earth Conductor | Green/Yellow, G Versions |
| Remaining Conductors | Black with Numerical Marking |
| X Versions | Without Green/Yellow Protective Earth Conductor |
Applicable Standards
| Standard | Reference Application |
|---|---|
| DIN VDE 0281-13 | Reference Cable Construction Standard |
| DIN EN 60228 | Flexible Copper Conductors, Class 5 |
| EN 60811-2-1 | Reference Oil Resistance Test Standard |
| EN 60332-1-2 | Vertical Flame Propagation Test on a Single Cable |
Special Configurations
| Cable Size | Reference Standard Status |
|---|---|
| 50G0.75 | Adapted to DIN VDE Standard |
| 2X1.5 | Adapted to DIN VDE Standard |
| 4G4 | Adapted to DIN VDE Standard |
| 5G4 | Adapted to DIN VDE Standard |
| 7G4 | Adapted to DIN VDE Standard |
| 4G6 | Adapted to DIN VDE Standard |
| 5G6 | Adapted to DIN VDE Standard |