A-DQ2Y – Optical Mini Cable G.657A1/G.652D (HT)

Compact single-mode optical fibre mini cable with stranded loose tubes, dielectric FRP strength member, dry water-blocking construction and a black HDPE outer sheath. Designed for installation by blowing into microducts.

12–288 Fibres Single-Mode G.657A1/G.652D HDPE Sheath FRP Strength Member Dry Water Blocking IEC 60794-5 Microduct Installation

Product Overview

A-DQ2Y Optical Mini Cable is a compact optical communication cable designed for installation by blowing into microduct systems.

The cable incorporates stranded loose tubes, each containing 12 optical fibres protected by a thixotropic filling compound.

A central fibre-reinforced plastic (FRP) strength member provides mechanical reinforcement. Depending on the cable configuration, the central strength member may include additional oversheathing. Dummy elements are incorporated where required.

The cable core features a dry water-blocking construction, while the black high-density polyethylene (HDPE) outer sheath provides external protection. A rip cord beneath the outer sheath facilitates cable preparation.

The reference cable range includes seven configurations from 12 to 288 single-mode optical fibres, with approximate outer diameters between 5.5 and 9.4 mm.

Key Technical Features

12–288Optical Fibres
5.5–9.4 mmOuter Diameter
1000 NMaximum Installation Tensile Load
+60°CMaximum Operating Temperature

Cable Designation

AOutdoor Optical Cable
DCompound-Filled Loose Tubes
QWater-Blocking Construction
2YPolyethylene Outer Sheath
n x 12Number of Loose Tubes with 12 Fibres Each
G.657A1/G.652DSingle-Mode Fibre Designation
HTReference Product Variant

Construction & Technical Properties

Cable Construction

Optical Fibre TypeSingle-Mode
Fibre DesignationG.657A1/G.652D
Number of Fibres12–288
Fibres per Loose Tube12
Loose Tube FillingThixotropic Compound
Loose Tube Diameter1.4 mm
Tube ArrangementStranded Loose Tubes
Central Strength MemberFibre-Reinforced Plastic (FRP)
Dummy ElementsWhere Required
Cable CoreDry Water-Blocking Construction
Outer SheathHDPE
Sheath Thickness0.5 mm
Sheath ColourCrna
Rip Cord1
Printing MethodInk Jet
Metre MarkingYes

Mechanical & Environmental Data

Outer Diameter5.5–9.4 mm
Cable Weight23–80 kg/km
Installation Tensile Load500–1000 N
Crush Resistance300 N
Bending Radius Under Tension20 x Cable Diameter
Bending Radius Without Tension15 x Cable Diameter
Operating Temperature-20°C to +60°C
Installation Temperature-5°C to +50°C
Storage Temperature-20°C to +70°C
Transport Temperature-20°C to +70°C
Installation MethodCable Blowing
Installation EnvironmentMicroducts
Microduct ConfigurationSingle Cable Installation

Optical Performance

≤0.36Attenuation at 1310 nm (dB/km)
≤0.22Attenuation at 1550 nm (dB/km)
125 µmNominal Cladding Diameter
≤1260 nmCut-Off Wavelength

Typical Applications

Optical Fibre Microduct Systems
Telecommunications Infrastructure
FTTH – Fibre to the Home
FTTB – Fibre to the Building
Broadband Access Networks
Optical Distribution Networks
Outdoor Fibre Optic Infrastructure
Cable Blowing Installations

Applicable Standards

IEC 60793-1 – Optical fibre measurement methods and test procedures.

IEC 60793-2 – Optical fibre product specifications.

IEC 60794-5 – Microduct cabling systems for installation by blowing.

ITU-T G.657A1 – Reference optical fibre specification for bending-loss insensitive single-mode fibres.

G.652D – Additional fibre designation stated in the reference product name.

Installation Conditions

The A-DQ2Y optical mini cable is intended for single-cable installation in microducts using cable blowing equipment.

The required microduct dimensions depend on the selected cable diameter and fibre configuration.

Recommended microduct dimensions for selected 72, 96, 144 and 288 fibre configurations are provided in the technical data section.

The specified installation temperature, tensile load and minimum bending radius must be observed during installation.

Technical Note: Cable dimensions and weights are indicative and subject to manufacturing tolerances. The HT designation is retained from the reference product name. CPR classification, UV resistance, direct burial suitability and crush test conditions are not specified in the reference documentation. Final fibre specifications, cable construction, installation suitability and availability must be confirmed for the supplied product.
UNIMA CABLE | TECHNICAL DIMENSIONS

A-DQ2Y – Cable Sizes & Technical Data

Seven reference single-mode optical mini cable configurations with 12–288 fibres, cable dimensions, mechanical characteristics, optical performance and recommended microduct dimensions.

7Reference Configurations
12–288Optical Fibres
5.5–9.4 mmOuter Diameter
23–80 kg/kmCable Weight

Available Cable Sizes & Dimensions

Tip kabela Configuration Number of Fibres Sheath Thickness (mm) Outer Diameter (mm) Installation Tensile Load (N) Crush Resistance (N) Fibre Type Cable Weight (kg/km)
Compact Mini Cables – 5.5 mm Outer Diameter
A-DQ2Y1x12120.55.5500300Single-Mode23
A-DQ2Y2x12240.55.5500300Single-Mode23
A-DQ2Y4x12480.55.5500300Single-Mode23
A-DQ2Y6x12720.55.5500300Single-Mode23
Higher Fibre Count Mini Cables – 6.2–9.4 mm Outer Diameter
A-DQ2Y8x12960.56.21000300Single-Mode34
A-DQ2Y12x121440.58.01000300Single-Mode55
A-DQ2Y24x122880.59.41000300Single-Mode80

Loose Tube & FRP Construction

Configuration Fibres Loose Tubes – Layer 1 Dummies – Layer 1 Loose Tubes – Layer 2 Dummies – Layer 2 Loose Tube Diameter (mm) FRP Dimension (mm)
1x121215––1.41.5
2x122424––1.41.5
4x124842––1.41.5
6x127260––1.41.5
8x129680––1.44.0
12x12144120––1.44.2 / 2.0
24x12288901501.42.8

Recommended Microduct Dimensions

Number of Fibres Cable Diameter (mm) Recommended Microduct OD/ID (mm)
125.5Not specified
245.5Not specified
485.5Not specified
725.512/8
966.212/8 or 14/10
1448.014/10 or 16/12
2889.416/12 or 20/15

OD/ID indicates the outer and inner diameter of the microduct. Recommendations are reproduced for the configurations specified in the reference documentation.

Minimum Bending Radius

Fibre Configuration Cable Diameter (mm) Under Tension – 20 x D (mm) Without Tension – 15 x D (mm)
12 Fibres5.511082.5
24 Fibres5.511082.5
48 Fibres5.511082.5
72 Fibres5.511082.5
96 Fibres6.212493
144 Fibres8.0160120
288 Fibres9.4188141

Bending radii are calculated using the approximate cable diameters and the specified bending radius factors. Actual minimum bending radii depend on the supplied cable diameter.

Optical Fibre Characteristics – G.657A1/G.652D

Optical Parameter Reference Value
Reference Fibre StandardITU-T G.657A1
Fibre TypeSingle-Mode
Cabled Fibre Attenuation at 1310 nm≤0.36 dB/km
Cabled Fibre Attenuation at 1550 nm≤0.22 dB/km
Mode Field Diameter at 1310 nm9.2 ± 0.4 µm
Mode Field Diameter at 1550 nm10.4 ± 0.8 µm
Zero Dispersion Wavelength1300–1324 nm
Zero Dispersion Slope≤0.092 ps/(nm²·km)
Polarisation Mode Dispersion (PMD)≤0.1 ps/√km
Cut-Off Wavelength≤1260 nm
Macrobending Loss at 1550 nm – 10 Turns, Ø30 mm≤0.25 dB
Macrobending Loss at 1550 nm – 1 Turn, Ø20 mm≤0.75 dB
Coated Fibre Outer Diameter200 ± 10 / 250 ± 10 µm
Cladding Diameter125 ± 1.0 µm
Core/Cladding Concentricity Error≤0.6 µm
Cladding Non-Circularity≤1.0%

Mechanical Characteristics

Parameter Reference Value Condition
Installation Tensile Load500 N12–72 Fibres
Installation Tensile Load1000 N96–288 Fibres
Crush Resistance300 NAll Configurations
Minimum Bending Radius20 x DUnder Tension
Minimum Bending Radius15 x DWithout Tension
Outer Sheath Thickness0.5 mmAll Configurations
Loose Tube Diameter1.4 mmAll Configurations
Installation MethodCable BlowingSingle Cable in Microduct

Temperature Characteristics

Condition Minimum Temperature Maximum Temperature
Operation-20°C+60°C
Installation-5°C+50°C
Storage-20°C+70°C
Transport-20°C+70°C

Optical Fibre Colour Identification

Fibre No. Colour Fibre No. Colour
1Red 13Red with Black Ring
2Green 14Green with Black Ring
3Blue 15Blue with Black Ring
4Yellow 16Yellow with Black Ring
5White 17White with Black Ring
6Grey 18Grey with Black Ring
7Brown 19Brown with Black Ring
8Violet 20Violet with Black Ring
9Cyan 21Cyan with Black Ring
10Crna 22Natural with Black Ring
11Orange 23Orange with Black Ring
12Pink 24Pink with Black Ring

The reference documentation includes a general 24-position fibre colour sequence. The listed A-DQ2Y configurations contain 12 fibres per loose tube.

Loose Tube Colour Identification

Loose Tube No. Colour Sequence – Variant 1 Colour Sequence – Variant 2
1RedRed
2GreenGreen
3BlueBlue
4YellowYellow
5WhiteWhite
6GreyGrey
7BrownBrown
8VioletViolet
9CyanCyan
10CrnaCrna
11OrangeOrange
12PinkPink
13WhiteRed with Black Ring
14WhiteGreen with Black Ring
15WhiteBlue with Black Ring

Each loose tube layer begins with position 1. In Variant 1, loose tubes from position 13 are white. In Variant 2, loose tubes from position 13 use ring marking. Dummy elements are natural coloured in both variants.

Applicable Technical Standards

Standard Description
IEC 60793-1Optical Fibre Measurement Methods and Test Procedures
IEC 60793-2Optical Fibre Product Specifications
IEC 60794-5Microduct Cabling Systems for Installation by Blowing
ITU-T G.657A1Bending-Loss Insensitive Single-Mode Optical Fibre Specification
Technical Note: Cable diameters and net weights are indicative. Cable weights are expressed in kg/km and exclude drums and packaging. The calculated bending radii are based on approximate outer diameters. Crush resistance is stated as 300 N; the reference documentation does not specify the associated test length or duration.
Data Verification: The FRP dimension of 4.2 / 2.0 mm for the 144-fibre configuration is reproduced as stated in the reference documentation. The 96-fibre configuration is identified as 8x12 based on the stated fibre count and loose tube arrangement. Missing values are marked with a dash or Not specified. Fibre coating diameter, loose tube colour variant, final construction, delivery lengths and availability must be confirmed for the supplied product.

Technical Documentation

Technical Data Sheet

EU declaration of conformity

Core Identification

Send Us email - RFQ


KOLEKCIJA KABELA UNIMA

Istražite našu ponudu kabela

Otkrijte vrste kabela, tehničke specifikacije i rješenja za svoje projekte.