UNIMA CABLE | FLEXIBLE RUBBER CABLES
H05RN-F – Flexible Rubber Cable
Fine-stranded copper cable with EPR rubber insulation and CR rubber sheath, designed for flexible appliance connections under low mechanical stress.
300/500 VClass 5 CopperEPR EI4CR EM260°CEN 50525-2-21
Product Overview
H05RN-F is a flexible rubber insulated cable with bare copper Class 5 fine-stranded conductors, EPR rubber EI4 insulation and a CR rubber EM2 outer sheath.
Designed for connecting vacuum cleaners, kitchen appliances, soldering irons and similar electrical devices under low mechanical stress in household, kitchen and office environments.
The cable is flame-retardant according to IEC 60332-1-2. It is not intended for permanent outdoor installation.
Key Technical Features
300/500 VRadni napon
60°CMaximum Conductor Temperature
Class 5Flexible Copper
3 × ØFixed Bending Radius
Construction & Technical Properties
Cable Construction
ConductorBare Copper
Conductor ClassClass 5 Fine Stranded
Core InsulationEPR Rubber EI4
Outer SheathCR Rubber EM2
Core IdentificationVDE 0293 / HD 308
Sheath ColourCrna
Technical Properties
Radni napon300/500 V
Maximum Conductor Temp.60°C
Fixed Cable Temperature-25°C to +60°C
Fixed Bending Radius3 × Outer Diameter
Moving Bending Radius4 × Outer Diameter
Flame RetardanceIEC 60332-1-2
Permanent Outdoor UseNot Suitable
Typical Applications
Household Electrical Appliances
Vacuum Cleaners
Kitchen Equipment
Office Electrical Devices
Soldering Irons
Low Mechanical Stress Connections
Applicable Standards
DIN EN 50525-2-21 – Rubber insulated flexible cables.
DIN EN IEC 60228 – Class 5 conductors.
IEC 60332-1-2 – Flame propagation test.
VDE 0293 / HD 308 – Core identification.
DIN EN IEC 60228 – Class 5 conductors.
IEC 60332-1-2 – Flame propagation test.
VDE 0293 / HD 308 – Core identification.
Installation Notice: H05RN-F is intended for low mechanical stress appliance connections. It is not suitable for permanent outdoor use. Selection must consider actual mechanical and environmental conditions.
Technical Data & Cable Dimensions
H05RN-F | Flexible Rubber Cable | 300/500 V | DIN EN 50525-2-21
6Configurations
300/500 VRadni napon
60°CMax. Conductor Temp.
Class 5Copper Conductor
| Part No. | Size | Sheath | Resistance Ω/km |
Outer Ø mm |
Copper kg/km |
Cable kg/km |
|---|---|---|---|---|---|---|
| 050168 | 02X0.75 | Crna | 26 | 6.2 | 14.4 | 60 |
| 050167 | 02X1 | Crna | 19.5 | 6.8 | 19 | 70 |
| 050166 | 03G0.75 | Crna | 26 | 6.6 | 21.6 | 80 |
| 050169 | 03G1 | Crna | 19.5 | 7.2 | 29 | 90 |
| 051065 | 04X0.75 | Crna | 26 | 8.8 | 29 | 76 |
| 051066 | 04G0.75 | Crna | 26 | 8.8 | 29 | 76 |
Showing 6 of 6 configurations
| Source: Klaus Faber AG
Technical notes:
Resistance values are in Ω/km. Outer diameters are approximate.
Copper and total cable weights are expressed in kg/km.
G = with protective conductor; X = without protective conductor.
BK = black sheath.
Current-carrying capacities are not specified in the manufacturer datasheet.