(N)HXH-J / (N)HXH-O FE180/E90 – Fire Resistant Power Cable 0.6/1 kV


Tehnički podaci

  • (N)HXH-J / (N)HXH-O FE180/E90
  • Tip kabela
  • Fire-Resistant Power Cable for Safety Installations
  • Područje primjene
  • VDE 0266 / DIN 4102-12 (E90)
  • Standard

Detaljnije

  • Izolacijski materijal FRNC Compound HI1
  • Pakiranje Wooden Drums / Coils
  • Dostupnost Stock
  • Cable Designation (N)HXH-J / (N)HXH-O FE180/E90
  • Fire Resistance FE180 – 180 minutes
  • Circuit Integrity E90 – 90 minutes
  • Radni napon 0.6/1 kV
  • Halogen-Free Yes
  • Low Smoke Emission IEC 61034
  • Flame Retardant IEC 60332-3-24 (Cat. C)
  • Protective Conductor J with PE / O without PE
  • Materijal vodiča Bare Copper (Class 1 / Class 2)
  • Grupa kabela Fire Performance Cables
  • Izolacijski materijal FRNC Compound HI1
  • Radni napon 0.6/1 kV
  • CPR razred According to manufacturer DoP
  • Standard VDE 0266 / DIN 4102-12 (E90)
UNIMA CABLE | Fire Performance Solutions

(N)HXH-J / (N)HXH-O FE180/E90

(N)HXH FE180/E90 is a halogen-free, fire-resistant power cable rated 0.6/1 kV, designed for fixed electrical installations in buildings with elevated fire safety requirements.

The cable provides FE180 fire resistance and E90 circuit integrity in appropriately tested installation systems. Its flame-retardant, low-smoke and halogen-free construction helps reduce smoke and corrosive gas emissions during a fire.

Available as (N)HXH-J with a protective conductor and (N)HXH-O without a protective conductor.

0.6/1 kV Radni napon
FE180 Fire Resistance
E90 Circuit Integrity
90°C Max. Conductor Temperature
FRNC Halogen-Free Construction
Cable Design

Construction

01

Copper Conductor

Bare copper conductor, Class 1 solid (RE); from 25 mm², Class 2 stranded (RM).

02

Core Insulation

Fire-resistant, halogen-free FRNC insulation compound, type HI1.

03

Core Identification

Core colours according to HD 308 / VDE 0293. The J version includes a green-yellow protective conductor; the O version has no protective conductor.

04

Outer Sheath

Flame-retardant, halogen-free FRNC compound, type HM1, with orange outer sheath.

Engineering Specifications

Technical Characteristics

Product designation(N)HXH-J / (N)HXH-O FE180/E90
Rated voltage U₀/U0.6/1 kV
Maximum operating voltage1.2 kV (three-phase systems)
Test voltage4 kV
Product standardVDE 0266
ConductorBare copper, Class 1 / Class 2
InsulationFRNC compound HI1
Outer sheathFRNC compound HM1
Sheath colourOrange
Maximum conductor temperature+90°C
Fixed installation temperature-30°C to +90°C
Minimum temperature during movement-5°C
Minimum bending radius, multicore12 × outer diameter
Minimum bending radius, single-core15 × outer diameter
Fire resistanceFE180
Circuit integrityE90, with tested installation systems
CPR classificationAccording to the applicable Declaration of Performance (DoP)
Where It Is Used

Typical Applications

Public and commercial buildings
Hospitals and healthcare facilities
Schools and educational facilities
Emergency power supply circuits
Fire safety electrical systems
Fixed installations in dry and wet rooms
Installation directly in concrete
Installations requiring E90 circuit integrity
Fire Safety

Fire Performance & Standards

VDE 0266 FE180 DIN 4102-12 | E90 IEC 60331-11 IEC 60332-3-24 IEC 61034 IEC 60754 HD 308
Important installation information: E90 circuit integrity applies only when the cable is installed as part of a suitably tested installation system, including the appropriate supports and fixing arrangements. The cable is not intended for direct burial in soil or use in water. Product-specific certificates and the applicable DoP should be checked before final project approval.

Technical Data & Cable Dimensions

(N)HXH-J / (N)HXH-O FE180/E90 | 0.6/1 kV | VDE 0266

68Listed Cable Variants
0.6/1 kVRadni napon
FE180Fire Resistance
E90Circuit Integrity
Cross-Section
(mm²)
Conductor
Class
Resistance
(Ω/km)
Current
(A)
Bending
Radius (mm)
Outer Ø
(mm)
Copper
(kg/km)
Cable Weight
(kg/km)
Source: Klaus Faber AG | (N)HXH FE180/E90
Technical information:
Resistance values refer to conductors at 20°C. Current ratings are specified for air at 30°C. Outer diameters are approximate. Copper and cable weights are expressed in kg/km. A dash indicates data not specified in the manufacturer's table.

Fire safety: E90 circuit integrity requires an appropriately tested installation system. Verify project-specific certificates and the applicable Declaration of Performance before installation.

Technical Documentation

Technical Data Sheet

EU declaration of conformity

Core Identification

Maximum 2 cross-sections per Data Sheet. 1 selected
UNIMA CABLE

(N)HXH-J / (N)HXH-O FE180/E90 Cable Calculator

Fire Resistant Power Cable 0.6/1 kV

Calculate cable weight, copper content and approximate cable length.

m
Cable Weight 0 kg
Cable Length 0 m
Copper Content 0 kg
Copper Share 0 %
Cable weight: 0 kg/km
Copper: 0 kg/km
Approximate values based on technical cable data. Actual values may vary due to manufacturing tolerances.