NSHXAFö – Halogen-Free Special Rubber Single-Core Cable 1.8/3 kV

Special flexible single-core rubber cable with a fine-stranded bare or tinned copper conductor, EPR rubber insulation and a black halogen-free polymer outer sheath. Designed for railway vehicles, trolleybuses, switchboards and electrical distribution equipment requiring short-circuit and earth fault protection.

1.8/3 kV 2.5–300 mm² Single Core Class 5 Copper EPR Insulation Halogen-Free Sheath Flame Retardant Oil Resistant Ozone Resistant Abrasion Resistant DIN VDE 0250-602 6 kV AC Test Voltage 250°C Short-Circuit Temperature

Product Overview

NSHXAFö is a special halogen-free single-core rubber cable with a rated voltage of 1.8/3 kV, designed with reference to DIN VDE 0250 Part 602.

The cable incorporates a fine-stranded bare or tinned copper conductor according to DIN EN 60228 Class 5, providing flexibility for routing and termination within electrical equipment.

The conductor is insulated with an ethylene propylene rubber (EPR) compound and protected by a black halogen-free polymer outer sheath.

The outer sheath is specified as resistant to ozone, abrasion and oil, with flame-retardant performance according to EN 60332-1-2.

NSHXAFö is intended for railway vehicles, trolleybuses and installations in dry locations, including switchboards and distribution equipment up to 1,000 V, where short-circuit and earth fault protection cable construction is required.

The reference product range covers 15 nominal conductor cross-sections from 2.5 mm² to 300 mm².

Key Technical Features

1.8/3 kVRated Voltage U0/U
2.5–300 mm²Conductor Range
Class 5Flexible Copper Conductor
6 kVAC Test Voltage
+250°CShort-Circuit Temperature
5 secMaximum Short-Circuit Duration
-40°CMinimum Fixed Temperature
15Reference Cable Sizes

Cable Construction & Technical Properties

Cable Construction

Conductor MaterialBare or Tinned Copper
Conductor ConstructionFine-Stranded, Class 5
Conductor StandardDIN EN 60228
Number of Cores1
Conductor Cross-Section2.5–300 mm²
Insulation MaterialEthylene Propylene Rubber (EPR)
Outer Sheath MaterialHalogen-Free Polymer
Outer Sheath ColourBlack
Sheath PropertiesOzone, Oil and Abrasion Resistant
Flame RetardancyEN 60332-1-2
Cable GeometryRound, Single-Core

Electrical & Mechanical Properties

Rated Voltage U0/U1.8/3 kV
AC Test Voltage6,000 V
Temperature in Motion-25°C to +70°C
Fixed Temperature Range-40°C to +70°C
Maximum Short-Circuit Temperature+250°C
Maximum Short-Circuit Duration5 Seconds
Minimum Fixed Bending Radius6 × Outer Diameter
Minimum Bending Radius in Motion10 × Outer Diameter
Oil Resistance StandardEN 60811-2-1
Current Rating in Air41–898 A
Approximate Outer Diameter7.5–34.5 mm
Copper Figure25–3,000 kg/km
Approximate Cable Weight70–3,050 kg/km

Flexible Copper Conductor

Class 5 Fine-Stranded Construction

The conductor consists of multiple fine copper wires arranged in a flexible stranded construction according to DIN EN 60228 Class 5.

The flexible construction facilitates routing and termination in electrical cabinets, distribution equipment and vehicle electrical installations.

Individual conductor wire diameters range from approximately 0.26 mm to 0.51 mm, depending on the nominal conductor cross-section.

Bare or Tinned Copper

The reference construction allows either bare copper or tinned copper conductors.

The required conductor finish should be specified according to the installation conditions and project requirements.

The final conductor material and finish must be confirmed during quotation.

EPR Insulation & Halogen-Free Outer Sheath

Ethylene Propylene Rubber Insulation

EPR rubber insulation provides the dielectric insulation required for the specified rated voltage of 1.8/3 kV.

The reference AC test voltage is 6 kV.

The specified maximum short-circuit temperature is +250°C for a maximum duration of five seconds.

The flexible rubber construction supports the documented installation and bending conditions.

Halogen-Free Polymer Outer Sheath

The black halogen-free polymer outer sheath provides mechanical protection and resistance to ozone, oil and abrasion.

Flame-retardant performance is specified according to EN 60332-1-2.

Oil resistance is specified according to EN 60811-2-1.

Additional smoke density and combustion gas performance classifications are not stated in the reference documentation.

Short-Circuit & Earth Fault Protection

NSHXAFö is designed for electrical installations requiring a short-circuit and earth fault protection cable construction.

The combination of flexible copper conductors, EPR insulation and a protective halogen-free sheath is intended for the documented applications in vehicle electrical systems, switchboards and distribution equipment.

The maximum specified short-circuit temperature is +250°C, with a maximum duration of five seconds.

The permissible short-circuit current must be determined according to conductor cross-section, prospective fault current, protective device operating time and the applicable installation requirements.

Typical Applications

Railway Vehicle Electrical Installations
Track-Bound Transportation Systems
Trolleybus Electrical Installations
Electrical Switchboards
Low-Voltage Distribution Equipment
Industrial Electrical Cabinets
Short-Circuit Protection Connections
Earth Fault Protection Applications
High-Current Equipment Connections
Electrical Installations in Dry Locations

Installation Conditions

Specified Installation Parameters

Dry LocationsSpecified Application
Railway VehiclesSpecified Application
TrolleybusesSpecified Application
Switchboards and DistributorsUp to 1,000 V
Fixed Temperature Range-40°C to +70°C
Temperature in Motion-25°C to +70°C
Fixed / Single Bend Radius6 × D
Bending Radius in Motion10 × D

Additional Installation Considerations

Continuous Drag Chain OperationNot Specified
Outdoor InstallationNot Specified
Direct BurialNot Specified
Permanent Water ImmersionNot Specified
UV ResistanceNot Specified
Maximum Installation Tensile LoadNot Specified
Minimum Bending RadiusBased on Actual Cable Diameter
Project RequirementsSubject to Technical Verification

Fire & Environmental Performance

Specified Properties

Halogen-Free ConstructionSpecified
Single-Cable Flame RetardancyEN 60332-1-2
Oil ResistanceEN 60811-2-1
Ozone ResistanceSpecified
Abrasion ResistanceSpecified

Additional Fire Performance Requirements

CPR ClassificationNot Specified
Low-Smoke Test ClassificationNot Declared
Halogen Gas Test StandardNot Specified
Fire-Resistant Circuit IntegrityNot Declared
EN 45545-2 Railway ClassificationNot Specified

Applicable Standards

DIN VDE 0250-602 – Reference product standard for special rubber cable construction.

DIN EN 60228 Class 5 – Flexible stranded conductors of insulated cables.

EN 60811-2-1 – Oil resistance test standard as referenced in the original technical documentation.

EN 60332-1-2 – Vertical flame propagation test for a single insulated wire or cable.

Technical Note: Technical characteristics are based on the reference NSHXAFö datasheet. Cable dimensions, copper figures and weights are reference values. Final construction, conformity documentation and availability must be confirmed during quotation.
Fire Performance Note: Halogen-free construction and flame retardancy do not constitute a declaration of low-smoke performance, CPR classification or fire-resistant circuit integrity. Railway-specific approvals must be verified separately.
UNIMA CABLE | TECHNICAL DIMENSIONS

NSHXAFö 1.8/3 kV – Cable Sizes & Technical Data

Complete reference range of halogen-free special single-core rubber cables with Class 5 copper conductors, EPR insulation and halogen-free polymer outer sheath, including copper figures, conductor construction, cable dimensions, current ratings and bending radii.

15Reference Cable Sizes
2.5–300 mm²Conductor Cross-Section
41–898 AReference Current Rating in Air
25–3,000Copper Figure kg/km

Complete Cable Size Range

Cable Size (mm²) Copper Figure (kg/km) Approx. Conductor Construction (n × mm) Approx. Outer Diameter (mm) Current Rating in Air (A) Approx. Cable Weight (kg/km)
Small Cross-Section Single-Core Cables
1x2.52550 × 0.267.54170
1x44056 × 0.319.05590
1x66084 × 0.319.570120
1x1010080 × 0.4111.098180
Medium Cross-Section Single-Core Cables
1x16160126 × 0.4113.0132250
1x25250196 × 0.4115.0176390
1x35350276 × 0.4116.5218470
1x50500396 × 0.4118.0276625
1x70700360 × 0.5120.5347880
1x95950475 × 0.5124.04161190
Large Cross-Section Single-Core Cables
1x1201200608 × 0.5126.04881430
1x1501500756 × 0.5128.05661750
1x1851850925 × 0.5131.06442160
1x24024001221 × 0.5134.57752718
1x30030001530 × 0.5130.6*8983050

All conductor construction values, copper figures, cable dimensions, current ratings and weights are reproduced from the reference technical documentation. Copper figures are published reference metal factors and should not automatically be interpreted as measured net copper mass.

Dimensional Verification: The original reference datasheet lists an approximate outer diameter of 30.6 mm for the 300 mm² cable, compared with 34.5 mm for the 240 mm² cable. The original values have been retained. The 300 mm² diameter must be confirmed before installation design or cable accessory selection.

Minimum Bending Radius by Cable Size

Cable Size (mm²) Approx. Outer Diameter (mm) Fixed / Single Bend 6 × D (mm) In Motion 10 × D (mm)
1x2.57.54575
1x49.05490
1x69.55795
1x1011.066110
1x1613.078130
1x2515.090150
1x3516.599165
1x5018.0108180
1x7020.5123205
1x9524.0144240
1x12026.0156260
1x15028.0168280
1x18531.0186310
1x24034.5207345
1x30030.6*183.6*306*

Bending radii are calculated from the published approximate outer diameters using the specified factors of 6 × D and 10 × D. Values marked with an asterisk require dimensional verification. Actual cable diameter must be used for final installation calculations.

Electrical Characteristics

ParameterReference Value
Rated Voltage U01,800 V
Rated Voltage U3,000 V
Rated Voltage U0/U1.8/3 kV
AC Test Voltage6,000 V AC
Conductor MaterialBare or Tinned Copper
Conductor ClassClass 5 Flexible
Conductor StandardDIN EN 60228
Nominal Cross-Section Range2.5–300 mm²
Current Rating in Air41–898 A
Maximum Short-Circuit Temperature+250°C
Maximum Short-Circuit Duration5 Seconds
DC Conductor Resistance at 20°CNot Specified
Insulation ResistanceNot Specified
CapacitanceNot Specified
InductanceNot Specified
Test Voltage DurationNot Specified

Temperature Characteristics

Operating Condition Minimum Temperature Maximum Temperature
In Motion-25°C+70°C
Fixed Installation-40°C+70°C
Short-Circuit TemperatureNot Applicable+250°C
Maximum Short-Circuit DurationNot Applicable5 Seconds
Continuous Conductor Operating TemperatureNot Separately SpecifiedNot Separately Specified

Cable Construction Layers

Layer Component Material / Construction
1ConductorFine-Stranded Bare or Tinned Copper, Class 5
2InsulationEthylene Propylene Rubber Compound (EPR)
3Outer SheathBlack Halogen-Free Polymer, Ozone, Oil and Abrasion Resistant

Conductor Stranding Overview

Nominal Cross-Section Range Approx. Individual Wire Diameter Conductor Construction
2.5 mm²0.26 mmClass 5 Copper
4–6 mm²0.31 mmClass 5 Copper
10–50 mm²0.41 mmClass 5 Copper
70–300 mm²0.51 mmClass 5 Copper

Mechanical & Environmental Properties

Property Standard / Reference Value Status
Conductor FlexibilityDIN EN 60228 Class 5Specified
Oil ResistanceEN 60811-2-1Specified
Ozone ResistanceHalogen-Free Polymer SheathSpecified
Abrasion ResistanceHalogen-Free Polymer SheathSpecified
Minimum Fixed Bending Radius6 × DSpecified
Minimum Bending Radius in Motion10 × DSpecified
Fixed Temperature Range-40°C to +70°CSpecified
Temperature in Motion-25°C to +70°CSpecified
UV ResistanceNot SpecifiedRequires Verification
Water Immersion ResistanceNot SpecifiedRequires Verification
Continuous Drag Chain OperationNot SpecifiedRequires Verification
Maximum Installation Tensile LoadNot SpecifiedRequires Verification
Outer Sheath ColourBlackSpecified

Fire Performance & Certification

Property Standard / Reference Declared Performance
Halogen-Free ConstructionReference Product DescriptionSpecified
Single-Cable Flame RetardancyEN 60332-1-2Specified
Bunched Cable Flame RetardancyIEC 60332-3 SeriesNot Declared
CPR Reaction to FireEN 50575 / EN 13501-6Not Specified
Low-Smoke PerformanceEN IEC 61034-2Not Declared
Halogen Gas Test PerformanceEN IEC 60754 SeriesTest Standard Not Specified
Fire-Resistant Circuit IntegrityIEC 60331 SeriesNot Declared
Railway Fire Safety ClassificationEN 45545-2Not Specified

Installation & Application Conditions

Application / Installation Method Reference Status
Railway Vehicle Electrical InstallationsSpecified Application
Trolleybus Electrical InstallationsSpecified Application
Dry LocationsSpecified Application
Electrical SwitchboardsSpecified Application
Distribution Equipment up to 1,000 VSpecified Application
Short-Circuit Protection ApplicationsSpecified Application
Earth Fault Protection ApplicationsSpecified Application
Outdoor InstallationNot Specified
Directly Buried InstallationNot Specified
Permanent Water ImmersionNot Specified
Battery Energy Storage SystemsProject-Specific Verification Required
Continuous Dynamic FlexingDuty Cycle Not Specified

Applicable Standards

StandardApplication
DIN VDE 0250-602Special Rubber Cable Construction
DIN EN 60228Conductors of Insulated Cables, Class 5
EN 60811-2-1Oil Resistance Test, as Referenced in Original Datasheet
EN 60332-1-2Vertical Flame Propagation Test for a Single Insulated Wire or Cable
Technical Note: All 15 cable sizes from the original NSHXAFö reference datasheet are included. Copper figures, conductor construction, outer diameters, current ratings and cable weights may vary according to the final manufacturer specification.
Current Rating Note: Published current ratings apply to the stated reference condition of installation in air. Actual permissible current must be determined according to installation method, ambient temperature, grouping, termination conditions and applicable electrical regulations.
Calculated Values: Minimum bending radii have been calculated using the published approximate cable diameters and the specified bending factors. These values are not separately measured manufacturer data.
Availability & Documentation: The reference cable range does not constitute a declaration of stock availability. Final construction, technical documentation, conductor finish and project-specific approvals must be confirmed during quotation.

Technical Documentation

Technical Data Sheet

EU declaration of conformity

Core Identification

Send Us email - RFQ