Find Your Cable

Select a cable or enter another designation.


UNIMA CABLE | SPECIAL APPLICATION & FLEXIBLE INDUSTRIAL CABLES

NGFLGöu – Flexible Flat Rubber Cable 300/500 V

Flexible flat rubber power and signal cable designed for medium mechanical stress, moving machine components, material handling equipment and large industrial machinery. Suitable for dry, damp and wet locations as well as outdoor installations involving bending in a single plane.

300/500 V 1.5–35 mm² 4–24 Cores Flat Cable Design Class 5 & 6 Copper Rubber Insulation 5GM3 Rubber Sheath Medium Mechanical Stress Outdoor Installation Single-Plane Bending Flame Retardant DIN VDE 0250-809 2 kV AC Test Voltage

Product Overview

NGFLGöu is a flexible flat rubber-insulated and rubber-sheathed cable rated at 300/500 V, designed for power supply and signal transmission applications under medium mechanical stress.

The cable incorporates fine-stranded bare copper conductors with Class 5 and Class 6 construction referenced according to DIN EN 60228.

The individual cores are insulated with a rubber compound and arranged in parallel. The cores are grouped, with individual groups separated by connecting webs.

A black 5GM3 rubber outer sheath provides mechanical protection and specified flame-retardant performance.

NGFLGöu is suitable for dry, damp and wet locations, as well as outdoor installations. It is particularly intended for moving machine tool components, material handling equipment and large industrial machinery where bending occurs in one plane only.

The reference product range includes 24 cable configurations, with nominal conductor cross-sections from 1.5 mm² to 35 mm² and configurations containing between 4 and 24 cores.

Key Technical Features

300/500 VRated Voltage U0/U
1.5–35 mm²Conductor Cross-Section
4–24Number of Cores
24Reference Configurations
2 kVAC Test Voltage
+200°CShort-Circuit Temperature
-40/+80°CFixed Installation
-25/+60°CTemperature During Bending

Cable Construction & Technical Properties

Cable Construction

Conductor MaterialBare Copper
Conductor ConstructionFine-Stranded, Class 5 and 6
Conductor StandardDIN EN 60228
Number of Cores4, 5, 7, 8, 12 or 24
Nominal Cross-Section1.5–35 mm²
Core InsulationRubber Compound (3GI3)
Core ArrangementParallel, Grouped Cores
Group SeparationConnecting Webs
Core IdentificationHD 308 S2
Outer SheathRubber Compound 5GM3
Outer Sheath ColourBlack
Cable GeometryFlat

Electrical & Mechanical Properties

Rated Voltage U0/U300/500 V
AC Test Voltage2,000 V
Temperature During Bending-25°C to +60°C
Fixed Temperature Range-40°C to +80°C
Maximum Short-Circuit Temperature+200°C
Maximum Short-Circuit Duration5 Seconds
Fixed / Single Bend Radius3 × Reference Cable Dimension
Radius During Bending5 × Reference Cable Dimension
Mechanical StressMedium
Bending DirectionSingle Plane Only
Flame RetardancyEN 60332-1-2
Approximate Cable Weight200–2,200 kg/km

Flat Cable Construction

Parallel Core Arrangement

Unlike conventional round cables, NGFLGöu features a flat construction with insulated conductors arranged in parallel.

The individual cores are organised into groups, with connecting webs separating the groups where applicable.

This construction is intended for applications involving controlled bending in one plane.

Flexible Copper Conductors

The cable incorporates fine-stranded bare copper conductors with Class 5 and Class 6 construction referenced according to DIN EN 60228.

The published conductor constructions include individual wire diameters of approximately 0.16 mm, 0.21 mm and 0.41 mm, depending on the conductor cross-section.

The exact conductor class for each cable size must be confirmed in the final manufacturer specification.

Rubber Insulation & Outer Sheath

Rubber Core Insulation

Each copper conductor is insulated with a rubber compound identified as 3GI3 in the reference technical documentation.

The insulation is designed for the specified rated voltage of 300/500 V and an AC test voltage of 2 kV.

The specified maximum short-circuit temperature is +200°C for a duration not exceeding five seconds.

5GM3 Rubber Outer Sheath

The black rubber outer sheath is manufactured from a 5GM3 rubber compound.

The reference construction is intended for medium mechanical stress in dry, damp and wet locations, including outdoor applications.

Single-cable flame propagation performance is specified according to EN 60332-1-2.

Moving Machinery & Material Handling Applications

NGFLGöu is intended for flexible electrical connections to moving components of machine tools, material handling equipment and large industrial machinery.

The flat construction is suitable for installations where the cable movement and bending direction are controlled within a single plane.

Potential applications include travelling machinery, moving industrial equipment and selected material handling systems, subject to verification of mechanical loads and installation conditions.

Applications involving torsion, multidirectional bending, high tensile loads or continuous high-cycle operation require separate technical confirmation.

Typical Applications

Moving Machine Tool Components
Material Handling Equipment
Large Industrial Machinery
Flexible Industrial Power Connections
Industrial Signal Transmission
Single-Plane Moving Cable Systems
Travelling Industrial Equipment
Selected Crane and Hoist Cable Systems
Industrial Production Equipment
Outdoor Industrial Installations

Installation Conditions

Specified Installation Parameters

Dry LocationsSuitable
Damp LocationsSuitable
Wet LocationsSuitable
Outdoor InstallationSuitable
Mechanical StressMedium
Bending DirectionSingle Plane
Fixed Temperature Range-40°C to +80°C
Temperature During Bending-25°C to +60°C

Additional Installation Considerations

Fixed / Single Bend Radius3 × Reference Dimension
Radius During Bending5 × Reference Dimension
Torsional MovementNot Specified
Multidirectional BendingOutside Specified Application
Maximum Travel SpeedNot Specified
Maximum Tensile LoadNot Specified
Continuous Flexing CyclesNot Specified
Permanent Water ImmersionNot Specified

Fire & Environmental Performance

Specified Properties

Single-Cable Flame RetardancyEN 60332-1-2
Wet Location InstallationSpecified
Outdoor InstallationSpecified
Mechanical Stress ResistanceMedium

Additional Performance Requirements

CPR ClassificationNot Specified
Halogen-Free PerformanceNot Declared
Low-Smoke PerformanceNot Declared
Oil Resistance TestNot Specified
UV Resistance TestNot Specified
Fire-Resistant Circuit IntegrityNot Declared

Applicable Standards

DIN VDE 0250-809 – Reference product standard for flat rubber cable construction.

DIN EN 60228 Class 5 and 6 – Flexible and highly flexible conductors of insulated cables.

HD 308 S2 – Identification of cores in cables and flexible cords.

EN 60332-1-2 – Vertical flame propagation test for a single insulated wire or cable.

Installation Note: NGFLGöu is intended for bending in one plane only. The original reference datasheet specifies bending factors of 3 and 5 but does not explicitly identify which flat cable dimension must be used for calculating the bending radius. Confirm the applicable dimension with the manufacturer before installation.
Technical Note: Technical characteristics are based on the reference NGFLGöu datasheet. Cable dimensions, copper figures and weights are reference values. Final construction, conductor identification, conformity documentation and availability must be confirmed during quotation.
UNIMA CABLE | TECHNICAL DIMENSIONS

NGFLGöu 300/500 V – Cable Sizes & Technical Data

Complete reference range of flexible flat rubber power and signal cables for medium mechanical stress, including conductor construction, copper figures, flat cable dimensions, cable weights and installation characteristics.

24Reference Configurations
1.5–35 mm²Conductor Cross-Section
4–24Number of Cores
57.6–1,344Copper Figure kg/km

Complete Cable Size Range

Cable Size (mm²) Copper Figure (kg/km) Approx. Conductor Construction (n × mm) Approx. Outer Dimensions (mm) Approx. Cable Weight (kg/km)
1.5 mm² Conductor Cross-Section
4x1.557.684 × 0.166.2 × 17.5200
5x1.572.084 × 0.166.2 × 21.5240
7x1.5100.884 × 0.166.2 × 29.0360
8x1.5115.284 × 0.166.2 × 31.5370
12x1.5172.884 × 0.166.5 × 47.0620
24x1.5345.684 × 0.1613.5 × 56.01010
2.5 mm² Conductor Cross-Section
4x2.596.0140 × 0.167.5 × 21.0280
5x2.5120.0140 × 0.167.5 × 27.0400
7x2.5168.0140 × 0.167.5 × 35.0520
8x2.5192.0140 × 0.167.5 × 39.0550
12x2.5288.0140 × 0.168.0 × 56.0800
24x2.5576.0140 × 0.1617.0 × 72.51690
4 mm² Conductor Cross-Section
4x4153.6224 × 0.169.0 × 26.0410
5x4192.0224 × 0.169.0 × 32.0560
7x4268.8224 × 0.169.0 × 42.0700
6 mm² Conductor Cross-Section
4x6230.4192 × 0.219.5 × 29.0600
5x6288.0192 × 0.219.5 × 35.0650
7x6403.2192 × 0.219.5 × 44.5850
10 mm² Conductor Cross-Section
4x10384.0320 × 0.2111.0 × 33.0800
7x10672.0320 × 0.2112.1 × 63.51350
16 mm² Conductor Cross-Section
4x16614.4512 × 0.2113.0 × 38.01150
5x16768.0512 × 0.2113.0 × 50.01450
25 mm² Conductor Cross-Section
4x25960.0800 × 0.2115.0 × 49.51700
35 mm² Conductor Cross-Section
4x351344.0280 × 0.4117.0 × 55.02200

All 24 cable configurations, copper figures, conductor constructions, outer dimensions and cable weights are reproduced from the reference technical documentation. Copper figures are published reference metal factors and should not automatically be interpreted as measured net copper mass.

Available Core & Cross-Section Configurations

Cross-Section (mm²) 4 Cores 5 Cores 7 Cores 8 Cores 12 Cores 24 Cores
1.5✓✓✓✓✓✓
2.5✓✓✓✓✓✓
4✓✓✓———
6✓✓✓———
10✓—✓———
16✓✓————
25✓—————
35✓—————

A check mark indicates a configuration listed in the reference datasheet, not confirmed stock availability. Other configurations are subject to separate enquiry.

Conductor Construction Overview

Nominal Cross-Section (mm²) Approx. Number of Wires Approx. Wire Diameter (mm) Conductor Material
1.5840.16Bare Copper
2.51400.16Bare Copper
42240.16Bare Copper
61920.21Bare Copper
103200.21Bare Copper
165120.21Bare Copper
258000.21Bare Copper
352800.41Bare Copper

DIN EN 60228 Class 5 and Class 6 are referenced in the original datasheet. The exact conductor class applicable to each cross-section is not individually specified.

Electrical Characteristics

ParameterReference Value
Rated Voltage U0300 V
Rated Voltage U500 V
Rated Voltage U0/U300/500 V
AC Test Voltage2,000 V AC
Conductor MaterialFine-Stranded Bare Copper
Conductor ClassClass 5 and Class 6 Referenced
Conductor StandardDIN EN 60228
Nominal Cross-Section Range1.5–35 mm²
Maximum Short-Circuit Temperature+200°C
Maximum Short-Circuit Duration5 Seconds
Current Carrying CapacityNot Specified
DC Conductor Resistance at 20°CNot Specified
Insulation ResistanceNot Specified
Test Voltage DurationNot Specified
CapacitanceNot Specified
InductanceNot Specified

Temperature Characteristics

Operating Condition Minimum Temperature Maximum Temperature
Fixed Installation-40°C+80°C
During Bending-25°C+60°C
Short-Circuit TemperatureNot Applicable+200°C
Short-Circuit DurationNot Applicable5 Seconds
Continuous Conductor Operating TemperatureNot Separately SpecifiedNot Separately Specified

Bending Radius & Mechanical Conditions

Parameter Reference Value
Fixed / Single Bend3 × Reference Cable Dimension
During Bending5 × Reference Cable Dimension
Bending DirectionSingle Plane Only
Mechanical StressMedium
Maximum Travel SpeedNot Specified
Maximum Tensile LoadNot Specified
Maximum AccelerationNot Specified
Maximum Bending CyclesNot Specified
Torsional MovementNot Specified
Multidirectional BendingOutside Specified Application
Bending Radius Note: The original datasheet expresses bending radius as a multiple of cable diameter, although NGFLGöu has a flat construction. The applicable reference dimension must be confirmed with the manufacturer. Numerical bending radii are therefore not calculated from the published flat cable dimensions.

Cable Construction Layers

Layer Component Material / Construction
1ConductorFine-Stranded Bare Copper
2Core InsulationRubber Compound 3GI3, Parallel Core Arrangement
3Outer SheathBlack Rubber Compound 5GM3, Flame Retardant

Core Identification & Cable Geometry

ParameterReference Specification
Core Identification StandardHD 308 S2
Number of Cores4, 5, 7, 8, 12 or 24
Core ArrangementParallel
Core GroupingGrouped Cores with Separating Webs
Cable GeometryFlat
Approximate First Outer Dimension6.2–17.0 mm
Approximate Second Outer Dimension17.5–72.5 mm
Outer Sheath ColourBlack
Protective Earth Core ConfigurationConfirm for Selected Cable Size

Mechanical & Environmental Properties

Property Reference Specification Status
Dry LocationsSpecified ApplicationSuitable
Damp LocationsSpecified ApplicationSuitable
Wet LocationsSpecified ApplicationSuitable
Outdoor InstallationSpecified ApplicationSuitable
Mechanical StressMediumSpecified
Single-Plane BendingSpecified ApplicationSuitable
Oil Resistance TestNot SpecifiedRequires Verification
Ozone ResistanceNot SpecifiedRequires Verification
UV Resistance TestNot SpecifiedRequires Verification
Permanent Water ImmersionNot SpecifiedRequires Verification
Direct BurialNot SpecifiedRequires Verification
Continuous Drag Chain OperationNot SpecifiedRequires Verification

Fire Performance & Certification

Property Standard / Reference Declared Performance
Single-Cable Flame RetardancyEN 60332-1-2Specified
Bunched Cable Flame RetardancyIEC 60332-3 SeriesNot Declared
CPR Reaction to FireEN 50575 / EN 13501-6Not Specified
Low-Smoke PerformanceEN IEC 61034-2Not Declared
Halogen-Free PerformanceEN IEC 60754 SeriesNot Declared
Fire-Resistant Circuit IntegrityIEC 60331 SeriesNot Declared

Installation & Application Conditions

Application Reference Status
Moving Machine Tool ComponentsSpecified Application
Material Handling EquipmentSpecified Application
Large Industrial MachinerySpecified Application
Flexible Power ConnectionsSpecified Application
Flexible Signal ConnectionsSpecified Application
Outdoor Industrial InstallationsSpecified Application
Crane and Hoist Cable SystemsProject-Specific Verification Required
Festoon Cable SystemsProject-Specific Verification Required
Cable Reel SystemsNot Specified
Elevator Travelling Cable ApplicationsNot Specified
High-Speed Continuous MovementNot Specified

Applicable Standards

StandardApplication
DIN VDE 0250-809Flat Rubber Cable Construction
DIN EN 60228Conductors of Insulated Cables, Class 5 and Class 6 Referenced
HD 308 S2Core Identification
EN 60332-1-2Vertical Flame Propagation Test for a Single Insulated Wire or Cable
Technical Note: All 24 configurations from the original NGFLGöu reference datasheet are included. Copper figures, conductor constructions, cable dimensions and cable weights are reference values and may vary according to the final manufacturer specification.
Electrical Design Note: Current carrying capacities are not specified in the reference datasheet. Actual permissible current must be determined according to installation conditions, ambient temperature, conductor loading and applicable electrical regulations.
Mechanical Installation Note: NGFLGöu is intended for medium mechanical stress and bending in a single plane. Maximum movement speed, tensile load, bending cycles and suitability for specific moving cable systems must be confirmed separately.
Availability & Documentation: The published reference range does not constitute a declaration of stock availability. Final cable construction, protective conductor configuration, conformity documentation and project-specific requirements must be confirmed during quotation.

Technical Documentation

Technical Data Sheet

EU declaration of conformity

Core Identification

Send Us email - RFQ


UNIMA CABLE COLLECTION

Explore Our Cable Range

Discover cable types, technical specifications and solutions for your projects.

96 Cable Types Available