H05BQ-F – PUR Flexible Rubber Cable 300/500 V
Flexible rubber-insulated connection cable with Class 5 copper conductors and a durable orange polyurethane outer sheath. Designed for industrial facilities, construction sites and demanding working environments requiring high mechanical and abrasion resistance.
Product Overview
H05BQ-F is a flexible rubber-insulated connection and supply cable designed for demanding industrial and construction environments.
The cable incorporates fine-stranded bare or tinned copper conductors according to DIN EN 60228 Class 5, providing flexibility during installation and handling.
The individual conductors are insulated with EL6 rubber compound and protected by an orange polyurethane (PUR) outer sheath.
The polyurethane sheath provides high resistance to abrasion and mechanical stress, making the cable suitable for applications exposed to demanding working conditions.
H05BQ-F can be used in dry, damp and wet environments, as well as outdoors.
The reference product range includes conductor cross-sections of 0.75 and 1 mm², with configurations from 2 to 5 cores.
Key Technical Features
Cable Variants
H05BQ-F 0.75 mm²
2X0.75 / 3G0.75 / 4G0.75 / 5G0.75
Flexible cable configurations with 0.75 mm² copper conductors.
Approximate outer diameter: 6.8–8.8 mm.
Approximate cable weight: 51–97 kg/km.
H05BQ-F 1 mm²
2X1 / 3G1 / 4G1 / 5G1
Flexible cable configurations with 1 mm² copper conductors.
Approximate outer diameter: 7.4–9.4 mm.
Approximate cable weight: 61–116 kg/km.
Construction & Technical Properties
Cable Construction
Electrical & Mechanical Data
PUR Outer Sheath & Mechanical Protection
Polyurethane Outer Sheath
The polyurethane outer sheath provides high abrasion resistance and protection against mechanical stress.
This construction is particularly suitable for industrial facilities and construction sites where cables are exposed to demanding working conditions.
The orange outer sheath provides a clearly identifiable cable appearance.
Rubber Insulation & Flexibility
The EL6 rubber insulation and fine-stranded Class 5 copper conductors provide a flexible cable construction.
The specified temperature range during bending is -40°C to +90°C.
The minimum bending radius is 4 times the cable diameter for one-time bending or fixed installation and 5 times the cable diameter during bending.
Oil Resistance & Flame Performance
Oil Resistance
The reference documentation specifies oil resistance according to EN 60811-2-1.
Suitability for specific oils, chemicals and prolonged exposure conditions must be confirmed for the selected product.
Flame Propagation
The reference documentation specifies EN 60332-1-2 for single-cable vertical flame propagation performance.
CPR Euroclass, low-smoke performance, halogen-free properties and fire-resistant circuit integrity are not specified.
Typical Applications
Installation Conditions
H05BQ-F is suitable for use in dry, damp and wet environments, as well as outdoor installations.
The cable is intended for connection and supply applications exposed to high mechanical stress and abrasion.
The specified temperature range during bending is -40°C to +90°C.
The minimum bending radius for one-time bending or fixed installation is 4 times the cable outer diameter.
The minimum bending radius during bending is 5 times the cable outer diameter.
Suitability for permanent water immersion, direct burial, continuous-flex drag chains, cable reels and torsional applications is not established by the reference documentation.
Applicable Standards
DIN VDE 0282-10 – Reference construction standard for flexible cables with elastomeric insulation and polyurethane sheathing.
DIN EN 60228, Class 5 – Flexible copper conductor construction.
HD 308 S2 – Identification of cable cores.
HD 22.10 S1+A1 – Reference harmonisation document for the specified cable construction.
EN 60811-2-1 – Reference standard cited for oil resistance.
EN 60332-1-2 – Vertical flame propagation test for a single insulated wire or cable.
Related Flexible Cable Types
Polyurethane Sheathed Cables
H05BQ-F – Flexible rubber-insulated cable with PUR sheath, rated 300/500 V.
H07BQ-F – Related polyurethane-sheathed flexible cable type rated 450/750 V.
Rubber Sheathed Cables
H05RR-F – Related flexible rubber-insulated and rubber-sheathed cable type.
H07RN-F – Related flexible rubber cable type for demanding supply and connection applications.
H05BQ-F – Cable Sizes & Technical Data
Complete reference range of flexible rubber-insulated, polyurethane-sheathed cables rated 300/500 V, including conductor construction, copper content, cable dimensions, approximate weights and installation parameters.
Available Cable Sizes & Construction Data
| Cable Size (mm²) | Number of Cores | Copper Content (kg/km) | Approx. Conductor Stranding | Approx. Outer Diameter (mm) | Approx. Cable Weight (kg/km) |
|---|---|---|---|---|---|
| H05BQ-F – 0.75 mm² | |||||
| 2X0.75 | 2 | 14.4 | 24 x 0.21 | 6.8 | 51 |
| 3G0.75 | 3 | 21.6 | 24 x 0.21 | 7.4 | 66 |
| 4G0.75 | 4 | 28.8 | 24 x 0.21 | 7.9 | 79 |
| 5G0.75 | 5 | 36.0 | 24 x 0.21 | 8.8 | 97 |
| H05BQ-F – 1 mm² | |||||
| 2X1 | 2 | 19.2 | 30 x 0.21 | 7.4 | 61 |
| 3G1 | 3 | 28.8 | 30 x 0.21 | 7.8 | 76 |
| 4G1 | 4 | 38.4 | 30 x 0.21 | 8.4 | 92 |
| 5G1 | 5 | 48.0 | 30 x 0.21 | 9.4 | 116 |
The letter G indicates a cable configuration including a green/yellow protective earth conductor. The letter X indicates a configuration without a green/yellow protective earth conductor.
Conductor stranding is expressed as the approximate number of individual wires multiplied by their nominal diameter in millimetres. Copper content values are reference figures and must not be interpreted as independently verified recoverable copper mass.
Conductor Construction by Cross-Section
| Nominal Cross-Section (mm²) | Approx. Conductor Stranding | Conductor Class | Reference Configurations |
|---|---|---|---|
| 0.75 | 24 x 0.21 mm | Class 5 | 4 |
| 1 | 30 x 0.21 mm | Class 5 | 4 |
Electrical Characteristics
| Parameter | Reference Value |
|---|---|
| Rated Voltage U0/U | 300/500 V |
| Test Voltage | 2000 V AC |
| Conductor Material | Bare or Tinned Copper |
| Conductor Construction | Fine-Stranded, Flexible |
| Conductor Class | Class 5 |
| Conductor Standard | DIN EN 60228 |
| Core Insulation | EL6 Rubber Compound |
| Core Identification | HD 308 S2 |
| Conductor DC Resistance | Not Specified |
| Current-Carrying Capacity | Not Specified |
| Insulation Resistance | Not Specified |
Temperature Characteristics
| Installation / Operating Condition | Minimum Temperature | Maximum Temperature |
|---|---|---|
| During Bending | -40°C | +90°C |
| Fixed Installation | Not Separately Specified | Not Separately Specified |
| Short-Circuit Condition | Not Specified | +200°C |
Maximum short-circuit duration: 5 seconds. The specified temperature range of -40°C to +90°C refers to the conditions stated in the reference documentation for bending.
Minimum Cable Bending Radius
| Cable Size (mm²) | Approx. Outer Diameter (mm) | One-Time Bending / Fixed Installation 4 x D (mm) | During Bending 5 x D (mm) |
|---|---|---|---|
| H05BQ-F – 0.75 mm² | |||
| 2X0.75 | 6.8 | 27.2 | 34.0 |
| 3G0.75 | 7.4 | 29.6 | 37.0 |
| 4G0.75 | 7.9 | 31.6 | 39.5 |
| 5G0.75 | 8.8 | 35.2 | 44.0 |
| H05BQ-F – 1 mm² | |||
| 2X1 | 7.4 | 29.6 | 37.0 |
| 3G1 | 7.8 | 31.2 | 39.0 |
| 4G1 | 8.4 | 33.6 | 42.0 |
| 5G1 | 9.4 | 37.6 | 47.0 |
Minimum bending radii are calculated from the approximate cable outer diameter using the specified bending factors of 4 x D and 5 x D. Actual installation requirements must be confirmed using the dimensions of the supplied cable.
Cable Construction Layers
| Layer | Component | Material / Construction |
|---|---|---|
| 1 | Conductor | Fine-Stranded Bare or Tinned Copper, Class 5 |
| 2 | Core Insulation | EL6 Rubber Compound |
| 3 | Outer Sheath | Orange Polyurethane (PUR) |
Core Identification & Cable Configurations
| Configuration | Number of Cores | Protective Earth | Identification Standard |
|---|---|---|---|
| 2X | 2 | No | HD 308 S2 |
| 3G | 3 | Yes | HD 308 S2 |
| 4G | 4 | Yes | HD 308 S2 |
| 5G | 5 | Yes | HD 308 S2 |
Mechanical & Environmental Characteristics
| Parameter | Reference Value |
|---|---|
| Outer Sheath Material | Polyurethane (PUR) |
| Outer Sheath Colour | Orange |
| Mechanical Stress Resistance | High |
| Abrasion Resistance | High |
| Oil Resistance | EN 60811-2-1 |
| Dry Environments | Suitable |
| Damp Environments | Suitable |
| Wet Environments | Suitable |
| Outdoor Installation | Suitable |
| Construction Site Applications | Suitable |
| Industrial Applications | Suitable |
| Minimum Bending Radius – Fixed | 4 x Cable Diameter |
| Minimum Bending Radius – During Bending | 5 x Cable Diameter |
| UV Resistance Test | Not Specified |
| Ozone Resistance | Not Specified |
| Direct Burial | Not Specified |
| Permanent Water Immersion | Not Specified |
| Continuous-Flex Applications | Not Specified |
| Torsional Applications | Not Specified |
| Maximum Pulling Force | Not Specified |
Fire Performance Characteristics
| Parameter | Reference Standard / Value |
|---|---|
| Single Cable Flame Propagation | EN 60332-1-2 |
| Bunched Cable Flame Propagation | Not Specified |
| CPR Euroclass | Not Specified |
| Halogen-Free Performance | Not Specified |
| Low Smoke Performance | Not Specified |
| Fire-Resistant Circuit Integrity | Not Specified |
Applicable Standards
| Standard | Reference Application |
|---|---|
| DIN VDE 0282-10 | Reference Flexible Cable Construction |
| DIN EN 60228 | Flexible Copper Conductors, Class 5 |
| HD 308 S2 | Core Identification |
| HD 22.10 S1+A1 | Reference Harmonisation Document for Cable Construction |
| EN 60811-2-1 | Reference Oil Resistance Standard |
| EN 60332-1-2 | Single Cable Vertical Flame Propagation Test |