Cat.6 U/FTP


Technical Specifications

  • Cat.6 U/FTP
  • Cable Type
  • Structured LAN Cabling & Gigabit Ethernet Networks
  • Application
  • ISO/IEC 11801 / IEC 61156-5 / EN 50173
  • Standard

Details

  • Insulation Material Foam-Skin Polyethylene (PE)
  • Packaging On Request
  • Availability Stock
  • Cable Category Category 6
  • Screening Type U/FTP
  • Number of Pairs 4
  • Conductor Material Solid Bare Copper
  • Conductor Size AWG23 / 0.56 mm
  • Insulation Foam-Skin PE
  • Conductor Material Solid Bare Copper, AWG23
  • Cable Group Data & Communication Cables
  • Insulation Material Foam-Skin Polyethylene (PE)
  • Rated Voltage 125 V Maximum Operating Voltage
  • CPR Class Eca
  • Standard ISO/IEC 11801 / IEC 61156-5 / EN 50173
UNIMA CABLE | DATA & COMMUNICATION CABLES

Cat.6 U/FTP – Shielded LAN Data Cable

Four-pair Category 6 Ethernet cable with individually foil-screened twisted pairs, AWG23 solid copper conductors and high-speed transmission performance up to 250 MHz.

CAT 6U/FTP250 MHz4 PairsAWG23CPR Eca

Product Overview

Cat.6 U/FTP is a screened data communication cable designed for structured local area networks, voice and data transmission and Gigabit Ethernet applications.

The cable consists of four twisted pairs of solid bare copper conductors, insulated with foam-skin polyethylene. Each pair is individually protected by laminated aluminium foil with a tinned copper contact wire. No overall screen is used.

Available sheath constructions include PVC and halogen-free LSHF/LSOH/FRNC options. The blue outer jacket is specified as RAL 5012.

Key Technical Features

250 MHzCategory 6 Bandwidth
100 ΩNominal Impedance
AWG23Solid Copper
EcaCPR Classification

Construction & Technical Properties

Cable Construction

ConductorSolid Bare Copper, 0.56 mm
Conductor SizeAWG23
InsulationFoam-Skin PE, Ø 1.35 mm
Pair Arrangement4 Twisted Pairs
Pair ScreensLaminated Aluminium Foil
Contact WireTinned Copper, AWG26
Overall ScreenNone
SheathPVC / LSHF / FRNC Options
Sheath ColourBlue, RAL 5012

Electrical & Mechanical Data

FrequencyUp to 250 MHz
DC Loop ResistanceMax. 176 Ω/km
Insulation ResistanceMin. 2000 MΩ·km
Capacitance43 nF/km at 800 Hz
Velocity Factor0.79
Operating VoltageMax. 125 V
Test Voltage1000 V DC, 1 min.
Operating Temperature-20°C to +60°C
Installation Temperature0°C to +50°C
Min. Bend Radius4D Fixed / 8D Installing
Max. Tensile Force100 N

Typical Applications

Structured LAN Cabling
Gigabit Ethernet Networks
Office & Commercial Networks
Data & Voice Transmission
Industrial Network Infrastructure
Horizontal & Vertical Cabling

Applicable Standards

ISO/IEC 11801 – Generic cabling systems.
IEC 61156-5 – Symmetrical pair cables.
EN 50173 – Information technology cabling.
EN 50288-5-1 – Metallic communication cables.
EN 50575 – CPR reaction-to-fire classification.
IEC 60332-1 – Flame propagation.
Installation note: Category 6 performance is specified up to 250 MHz. Gigabit Ethernet channel length is up to 100 m under appropriate installation conditions. For 10GBASE-T, the manufacturer indicates a maximum of 55 m. Halogen-free and enhanced flame-retardant characteristics depend on the selected sheath variant.

Technical Data & Cable Dimensions

Cat.6 U/FTP | 4 × 2 × AWG23 | 250 MHz | PVC / LSHF

250 MHzRated Bandwidth
4 PairsIndividually Screened
24 kg/kmCopper Weight
EcaCPR Class

Available Sheath Variants

ConfigurationSheathOuter Ø (mm)Copper (kg/km)Cable (kg/km)Colour
4x2xAWG23 PVCPVC6.5–7.62441Blue RAL 5012
4x2xAWG23 LSHFHalogen-Free6.5–7.62444Blue RAL 5012

Transmission Performance at 20°C

Frequency
MHz
Attenuation
dB/100m
NEXT
dB
PS-NEXT
dB
ACR
dB/100m
PS-ACR
dB/100m
ELFEXT
dB/100m
PS-ELFEXT
dB/100m
Return Loss
dB
11.8100979895105105—
43.410097979410510227
105.4100979592979430
166.8100979390939030
207.7100979289918830
31.29.6100979087878430
62.513.7100978683817830
10017.4100978380777430
12519.595927572757226
155.521.994917269737026
17523.393907067726925
2002592896764716825
25028.190876259696624
30030.989865855676424
40038.387844845646123
Showing 15 of 15 frequencies
Technical notes: Values above are nominal transmission characteristics from the source catalogue. Category 6 is specified up to 250 MHz; the 300 and 400 MHz rows are additional manufacturer reference measurements, not an extension of the Cat.6 rating. Outer diameter is given as a range because individual sheath constructions may vary.

Technical Documentation

Technical Data Sheet

EU declaration of conformity

Core Identification

Maximum 2 cross-sections per Data Sheet. 1 selected
UNIMA CABLE

Cat.6 U/FTP Cable Calculator

Calculate cable weight, copper content and approximate cable length.

m
Cable Weight 0 kg
Cable Length 0 m
Copper Content 0 kg
Copper Share 0 %
Cable weight: 0 kg/km
Copper: 0 kg/km
Approximate values based on technical cable data. Actual values may vary due to manufacturing tolerances.
distributor wire and cable 35kv sourcing
Unima d.d.

Why Unima Cable?

B2B partner for cable distribution across Europe and global industrial projects

Years of Experience
0 +
Fast Delivery
0 +h
Technical Documentation Files
0 +
Markets Served
0 +