XRUHKXS / 2XS(FL)2Y / N2XS(FL)2Y – 76/132 (145) kV

Potraži kabel

Select a cable or enter another designation.


UNIMA CABLE | HIGH VOLTAGE POWER CABLES

XRUHKXS / 2XS(FL)2Y / N2XS(FL)2Y – 76/132 (145) kV

Single-core copper conductor high-voltage power cable with XLPE insulation, metallic screening and protective outer sheath for high-voltage transmission and distribution networks.

76/132 (145) kV Copper Conductor XLPE Insulation 95 mm² Metallic Screen 15 Reference Sizes IEC 60840

Product Overview

XRUHKXS / 2XS(FL)2Y / N2XS(FL)2Y is a single-core high-voltage power cable with a copper conductor, rated 76/132 (145) kV.

The reference construction features a stranded copper conductor, semiconductive conductor screen, XLPE insulation, semiconductive insulation screen, metallic screen and protective outer sheath.

The reference range covers 15 conductor sizes from 185 to 3000 mm², including RM and RMS conductor configurations. Cable dimensions, insulation thickness, weight and mechanical properties vary according to the selected size.

Key Technical Features

76/132 (145)Rated Voltage (kV)
185–3000Conductor Size (mm²)
15Reference Sizes
95 mm²Metallic Screen

Construction & Technical Properties

Cable Construction

Number of Cores1
Materijal vodičaCopper
Conductor DesignationRM / RMS
Conductor ScreenSemiconductive Layer
InsulationXLPE
Nominal Insulation Thickness16.0–18.0 mm
Insulation ScreenSemiconductive Layer
Metallic Screen95 mm²
Outer SheathProtective PE Sheath

Reference Technical Data

Radni napon76/132 (145) kV
Conductor Size Range185–3000 mm²
Nominal Insulation Thickness16.0–18.0 mm
Metallic Screen95 mm²
Conductor ResistanceAt 90°C
Outer DiameterSize Dependent
Cable WeightSize Dependent
Minimum Bending RadiusSize Dependent

Typical Applications

High-Voltage Transmission Networks
Utility Power Infrastructure
High-Voltage Substation Connections
Industrial High-Voltage Power Systems

Referenced Standards

IEC 60840 – Referenced for XRUHKXS and 2XS(FL)2Y.
DIN VDE 0276-632 – Referenced for N2XS(FL)2Y.
Technical Note: Values are based on the supplied reference catalogue. Dimensions, electrical characteristics and installation parameters vary by conductor size. Final specifications and compliance must be confirmed with the supplying manufacturer. CPR classification is not specified in the supplied excerpt.
UNIMA CABLE | TECHNICAL DIMENSIONS

XRUHKXS / 2XS(FL)2Y / N2XS(FL)2Y – Cable Sizes

76/132 (145) kV copper conductor high-voltage cable. Reference dimensions, metallic screen, mechanical properties and cable weight per kilometre.

15Reference Sizes
185–3000Conductor Size (mm²)
69–124Outer Diameter (mm)
5730–38520Cable Weight (kg/km)

Available Cable Sizes

Conductor (mm²) Conductor Diameter (mm) Insulation Thickness (mm) Metallic Screen (mm²) Outer Diameter (mm) Cable Weight (kg/km) Max. Pulling Force (kN) Min. Bending Radius (m)
185 RM15.818.0956957309.31.7
240 RM18.518.09570622012.01.7
300 RM20.518.09570677015.01.8
400 RM23.618.09572782020.01.8
500 RM26.418.09575880025.01.9
630 RM30.318.095801038031.52.0
800 RM34.718.095841225040.02.1
1000 RM38.318.095881439050.02.2
1200 RMS41.818.095941687060.02.3
1400 RMS45.818.095981882070.02.5
1600 RMS49.818.0951022091080.02.6
1800 RMS53.218.0951062335090.02.7
2000 RMS54.618.09510724900100.02.7
2500 RMS60.018.09511530050100.02.9
3000 RMS68.418.09512438520100.03.1
Technical Note: Values are based on the supplied reference catalogue. Cable weights are expressed in kg/km and exclude drums and packaging. Metallic screen cross-section is 95 mm². Separate copper weight is not specified. Final technical specifications must be confirmed with the supplying manufacturer.