UNIMA CABLE | HEAVY DUTY REELING CABLES
(N)SHTOEU-J – Heavy Duty Reeling Cable 0.6/1 kV
Extra heavy-duty flexible rubber power cable engineered for reeling and hoisting applications involving high mechanical stress, simultaneous tensile loads and torsional forces.
0.6/1 kV
Copper Class 5
HEPR Insulation
5GM5 Rubber
Torsion Protection
240 m/min
UV Resistant
Oil Resistant
Product Overview
(N)SHTOEU-J is an extra heavy-duty flexible power cable designed for demanding reeling and hoisting applications involving combined tensile and torsional stresses.
The construction incorporates fine-stranded bare copper conductors, HEPR insulation, split protective conductors positioned in the outer interstices, a 5GM5 rubber inner sheath, synthetic torsion protection braid and a yellow 5GM5 rubber outer sheath.
Suitable for motor-driven cable reels, spring-operated reels and hoisting systems, with a reference operating speed of up to 240 m/min.
The outer sheath provides resistance to UV radiation, oil and ozone. The cable is flame retardant according to IEC 60332-1-2.
Key Technical Features
0.6/1 kVRadni napon
240 m/minOperating Speed
+90°CMax. Conductor Temperature
30 N/mm²Max. Conductor Tensile Stress
Construction & Technical Properties
Cable Construction
ConductorBare Copper
Conductor ClassClass 5, Fine Stranded
Conductor StandardEN IEC 60228
InsulationHEPR
Protective ConductorSplit in Outer Interstices
Inner SheathRubber 5GM5
Torsion ProtectionSynthetic Braid
Outer SheathRubber 5GM5
Sheath ColourYellow
Core IdentificationVDE 0293 / HD 308
Electrical & Mechanical Data
Radni napon0.6/1 kV
Max. Operating Voltage1.2 kV (Three-Phase)
Test Voltage3.5 kV
Max. Conductor Temp.+90°C
Fixed Cable Temp.-40°C to +80°C
Moving Cable Temp.-30°C to +80°C
Operating Speed240 m/min
Max. Conductor Tensile Stress30 N/mm²
Flame RetardantIEC 60332-1-2
UV ResistanceYes
Oil ResistanceIEC 60811-404
Ozone ResistanceYes
Minimum Bending Radii
Free Movement5 × D
Reeling Operation6 × D
Multi-Roller Systems7.5 × D
S-Shaped Track Curves≥ 20 × D
Typical Applications
Motor-Driven Cable Reels
Spring-Operated Cable Reels
Industrial Hoisting Systems
Heavy-Duty Reeling Systems
Mobile Equipment Power Supplies
Combined Tensile and Torsional Loads
Applicable Standards
VDE 0250-814 – Reference cable construction standard.
DIN EN IEC 60228 / VDE 0295 – Class 5 copper conductors.
VDE 0293 / HD 308 – Core identification.
IEC 60332-1-2 – Flame propagation test.
DIN EN 60811-404 / IEC 60811-404 / VDE 0473-811-404 – Oil resistance test.
Installation & Application Note:
Cable selection must take into account the actual operating speed, tensile forces, torsional loads, reel geometry and bending radii. D represents the outer cable diameter. Technical values refer to the reference cable construction and must be confirmed for the supplied product. CPR classification is not specified.
UNIMA CABLE | TECHNICAL DIMENSIONS
(N)SHTOEU-J – Cable Sizes & Technical Data
Heavy-duty reeling cable reference configuration with electrical resistance, current rating, short-circuit current, outer diameter range, tensile forces, copper weight and total cable weight.
621 ACurrent Rating in Air
44.7 kAShort-Circuit Current (1 s)
73–76 mmOuter Diameter
13,385 kg/kmCable Weight
Available Cable Sizes
| Size (mm²) |
Resistance (Ω/km) |
Current Air 30°C (A) |
Short-Circuit Current 1 s (kA) |
Min. Outer Diameter (mm) |
Max. Outer Diameter (mm) |
Permanent Tensile Force (N) |
Dynamic Tensile Force (N) |
Copper Weight (kg/km) |
Cable Weight (kg/km) |
| 3x300+3x150/3 |
0.0641 |
621 |
44.7 |
73 |
76 |
13500 |
27000 |
10080 |
13385 |
Technical Note:
Current rating refers to installation in air at 30°C. Short-circuit current refers to a duration of 1 second. Outer diameters are approximate. Copper weight follows the German Cu GER convention. Cable weight is expressed in kg/km, excluding drums and packaging. Conductor resistance reference temperature is not explicitly stated. The permissible tensile forces must be evaluated for the actual installation and operating conditions.