FG16OR16 Flexible Copper Power Cable 0.6/1 kV
FG16OR16 is a low-voltage power cable featuring flexible Class 5 copper conductors, G16 rubber insulation and a grey R16 PVC outer sheath.
Designed for fixed electrical installations in industrial facilities, construction projects and building infrastructure. Suitable for indoor and outdoor installations, including wet environments and direct or indirect underground installation.
Construction
CU / G16 / BEDDING / R16 PVC
Flexible copper conductors, Class 5 according to EN 60228.
G16 rubber insulation compound.
Colour-coded insulated cores according to HD 308 S2.
Extruded elastomeric or plastomeric compound.
Grey R16 PVC compound. Other colours on request.
Unscreened flexible copper power cable for fixed installation.
Technical Data
Electrical and installation characteristics
Standardi
Applicable cable standards
Primjene
Fixed low-voltage electrical installations
FG16OR16 Cable Sizes & Technical Data
Select a conductor configuration to view electrical characteristics, cable dimensions and approximate weights.
Technical Size Table 25 sizes
| Cable Size | Resistance 20°C Ω/km |
Insulation mm |
Sheath mm |
Current A |
Outer Ø mm |
Weight kg/km |
|---|---|---|---|---|---|---|
| 2x1.5 | 13.30 | 0.7 | 1.8 | 26 | 12.0 | 130 |
| 2x2.5 | 7.98 | 0.7 | 1.8 | 36 | 13.0 | 165 |
| 2x4 | 4.95 | 0.7 | 1.8 | 49 | 14.2 | 210 |
| 2x6 | 3.30 | 0.7 | 1.8 | 63 | 15.4 | 270 |
| 2x10 | 1.91 | 0.7 | 1.8 | 86 | 17.3 | 390 |
| 2x16 | 1.21 | 0.7 | 1.8 | 115 | 19.4 | 520 |
| 2x25 | 0.780 | 0.9 | 1.8 | 149 | 23.0 | 765 |
| 2x35 | 0.554 | 0.9 | 1.8 | 185 | 25.7 | 1020 |
| 2x50 | 0.386 | 1.0 | 1.8 | 225 | 29.3 | 1400 |
| 3x1.5 | 13.30 | 0.7 | 1.8 | 23 | 12.5 | 150 |
| 3x2.5 | 7.98 | 0.7 | 1.8 | 32 | 13.6 | 190 |
| 3x4 | 4.95 | 0.7 | 1.8 | 42 | 14.9 | 250 |
| 3x6 | 3.30 | 0.7 | 1.8 | 54 | 16.2 | 320 |
| 3x10 | 1.91 | 0.7 | 1.8 | 75 | 18.2 | 470 |
| 3x16 | 1.21 | 0.7 | 1.8 | 100 | 20.6 | 640 |
| 3x25 | 0.780 | 0.9 | 1.8 | 127 | 24.5 | 960 |
| 3x35 | 0.554 | 0.9 | 1.8 | 158 | 27.3 | 1290 |
| 3x50 | 0.386 | 1.0 | 1.8 | 192 | 31.2 | 1785 |
| 3x70 | 0.272 | 1.1 | 1.9 | 246 | 35.6 | 2700 |
| 3x95 | 0.206 | 1.1 | 2.0 | 298 | 40.0 | 3410 |
| 3x120 | 0.161 | 1.2 | 2.1 | 346 | 44.4 | 4340 |
| 3x150 | 0.129 | 1.4 | 2.3 | 399 | 49.5 | 5404 |
| 3x185 | 0.106 | 1.6 | 2.4 | 456 | 55.2 | 6550 |
| 3x240 | 0.0801 | 1.7 | 2.6 | 538 | 61.9 | 8475 |
| 3x300 | 0.0641 | 1.8 | 2.8 | 621 | 68.0 | 10440 |
No cable sizes match your search.
DC conductor resistance is specified at 20°C. Cable dimensions and weights are approximate. Current-carrying capacity depends on installation conditions and applicable correction factors. Verify the selected cable size against the corresponding technical datasheet.