XRUHKXS / 2XS(FL)2Y / N2XS(FL)2Y – 36/60 (72.5) kV

Find Your Cable

Select a cable or enter another designation.


UNIMA CABLE | HIGH VOLTAGE POWER CABLES

XRUHKXS / 2XS(FL)2Y / N2XS(FL)2Y – 36/60 (72.5) kV

Single-core copper conductor high-voltage power cable with XLPE insulation, metallic screen and protective polyethylene outer sheath for high-voltage electricity transmission and distribution.

36/60 (72.5) kV Copper Conductor XLPE Insulation 10.0 mm Insulation Metallic Screen IEC 60840 DIN VDE 0276-632

Product Overview

XRUHKXS / 2XS(FL)2Y / N2XS(FL)2Y is a single-core copper conductor high-voltage power cable rated 36/60 (72.5) kV.

The reference construction features a stranded copper conductor, semiconductive conductor screen, XLPE insulation, semiconductive insulation screen, metallic screen and protective outer sheath.

The reference cable range covers conductor cross-sections from 120 to 3000 mm². Electrical and mechanical characteristics depend on conductor size and installation configuration.

Key Technical Features

36/60 (72.5)Rated Voltage (kV)
120–3000Conductor Size (mm²)
17Reference Sizes
10.0 mmNominal Insulation Thickness

Construction & Technical Properties

Cable Construction

Number of Cores1
Conductor MaterialCopper
Conductor DesignationRM / RMS
Conductor ScreenSemiconductive Layer
InsulationXLPE
Nominal Insulation Thickness10.0 mm
Insulation ScreenSemiconductive Layer
Metallic Screen35 or 50 mm²
Outer SheathPolyethylene (PE)

Reference Technical Data

Rated Voltage36/60 (72.5) kV
Conductor Size Range120–3000 mm²
Insulation Thickness10.0 mm
Conductor ResistanceAt 90°C
Metallic Screen35 / 50 mm²
Maximum Pulling ForceSize Dependent
Minimum Bending RadiusSize Dependent
Electrical ParametersSize Dependent

Typical Applications

High-Voltage Power Distribution
Utility Power Networks
Substation Connections
Industrial Power Infrastructure

Referenced Standards

IEC 60840 – Referenced for XRUHKXS and 2XS(FL)2Y.
DIN VDE 0276-632 – Referenced for N2XS(FL)2Y.
Technical Note: Values are based on the supplied reference catalogue. Dimensions, cable weights, electrical parameters and mechanical characteristics depend on the selected conductor size. Final construction and compliance must be confirmed with the supplying manufacturer. CPR classification is not specified in the supplied excerpt.
UNIMA CABLE | TECHNICAL DIMENSIONS

XRUHKXS / 2XS(FL)2Y / N2XS(FL)2Y – Cable Sizes

36/60 (72.5) kV copper conductor high-voltage cable. Reference dimensions, metallic screen sizes and cable weights per kilometre.

17Reference Sizes
120–3000Conductor Size (mm²)
44–109Outer Diameter (mm)
2670–33750Cable Weight (kg/km)

Available Cable Sizes

Conductor (mm²) Conductor Diameter (mm) Insulation Thickness (mm) Metallic Screen (mm²) Outer Diameter (mm) Cable Weight (kg/km) Max. Pulling Force (kN) Min. Bending Radius (m)
120 RM12.810.0354426706.01.1
150 RM14.410.0354629807.51.1
185 RM15.810.0354733709.31.2
240 RM18.510.03550390012.01.3
300 RM20.510.03552465015.01.3
400 RM23.810.03558588020.01.4
500 RM26.410.03560678025.01.5
630 RM30.310.03564822031.51.6
800 RM34.710.03568998040.01.7
1000 RM38.310.035731214050.01.8
1200 RMS41.810.050791450060.02.0
1400 RMS45.810.050831638070.02.1
1600 RMS49.810.050871858080.02.2
1800 RMS53.210.050912093090.02.3
2000 RMS54.810.0509322490100.02.3
2500 RMS60.010.05010027450100.02.5
3000 RMS68.410.05010933750100.02.7
Technical Note: Values are based on the supplied reference catalogue. Cable weights are in kg/km and exclude drums and packaging. Metallic screen cross-sections are 35 or 50 mm². Separate copper weight is not provided in the source table. Confirm all technical parameters with the supplying manufacturer.