(N)TMCWOEU – Flexible Medium Voltage Cable

Flexible single-core screened power cable with fine-stranded tinned copper conductors, rubber insulation and a robust red rubber outer sheath, designed for short-distance switchgear and mobile transformer substation connections.

6/10 kV 12/20 kV 18/30 kV 26/45 kV Tinned Copper Class 5 Rubber 3GI3 Rubber 5GM5 UV Resistant Oil Resistant

Product Overview

(N)TMCWOEU is a flexible single-core screened power cable designed for short-length connections in switchgear installations and mobile transformer substations.

The cable incorporates a fine-stranded tinned copper conductor, rubber 3GI3 insulation, inner and outer semiconducting rubber layers for electrical field control, a spiral tinned copper wire screen and a red rubber 5GM5 outer sheath.

Four rated voltage configurations are included in the reference range: 6/10 kV, 12/20 kV, 18/30 kV and 26/45 kV.

The cable combines flexible construction with resistance to UV radiation and oil. Flame retardancy is specified according to IEC 60332-1-2.

Key Technical Features

6/10–26/45 kVRated Voltage Range
25–630 mm²Conductor Range
Class 5Tinned Copper Conductor
+90°CMax. Conductor Temperature

Construction & Technical Properties

Cable Construction

ConductorTinned Copper
Conductor ClassClass 5, Fine Stranded
Conductor StandardEN IEC 60228
Number of Cores1
InsulationRubber 3GI3
Electrical Field ControlInner and Outer Semiconducting Rubber Layers
ScreenSpiral Tinned Copper Wires
Screen Cross-Section16–50 mm²
Outer SheathRubber 5GM5
Sheath ColourRed

Electrical & Mechanical Data

Rated Voltage6/10, 12/20, 18/30, 26/45 kV
Max. Conductor Temp.+90°C
Short-Circuit Temp.+200°C
Fixed Cable Temp.-40°C to +80°C
Moving Cable Temp.-25°C to +60°C
Fixed Bending Radius6 × D
Moving Bending Radius10 × D
Max. Tensile Stress15 N/mm²
Flame RetardantIEC 60332-1-2
UV ResistanceDIN EN 50289-4-17
Oil ResistanceEN 60811-2-1

Voltage Configurations

Rated Voltage / Test Voltage

6/10 kV17 kV
12/20 kV29 kV
18/30 kV43 kV
26/45 kV87 kV
Max. Operating Voltage (6/10 kV)12 kV, Three-Phase

Typical Applications

Medium Voltage Switchgear Connections
Switchgear Cubicle Interconnections
Mobile Transformer Substations
Short-Length Flexible Power Connections

Applicable Standards

DIN VDE 0250-813 – Reference cable construction standard.
DIN EN IEC 60228 / VDE 0295 – Flexible Class 5 conductors.
VDE 0298-4 – Current carrying capacity.
IEC 60332-1-2 / VDE 0482-332-1-2 – Flame propagation test.
DIN EN 50289-4-17 / VDE 0819-289-4-17 – UV resistance.
EN 60811-2-1 – Oil resistance reference test.
Installation & Application Note: Designed for short-length flexible power connections. Cable selection must consider the actual system voltage, installation conditions, bending radius, tensile stress and termination requirements. D represents the outer cable diameter. CPR classification is not specified. All technical data must be confirmed for the supplied product.
UNIMA CABLE | TECHNICAL DIMENSIONS

(N)TMCWOEU – Cable Sizes & Technical Data

23 reference cable configurations across four voltage classes, including conductor resistance, current ratings, outer diameter ranges, copper weight and total cable weight.

23Reference Configurations
25–630 mm²Conductor Range
4Voltage Classes
Cu Class 5 Tinned Copper

Available Cable Sizes

Size (mm²) Resistance (Ω/km) Current Air 30°C (A) Min. Diameter (mm) Max. Diameter (mm) Approx. Diameter (mm) Copper Weight (kg/km) Cable Weight (kg/km)
(N)TMCWOEU 6/10 kV – Test Voltage 17 kV
1x95/160.2130127332910901492
1x300/250.06546203946.541.631753803
(N)TMCWOEU 12/20 kV – Test Voltage 29 kV
1x35/160.56517224.53126.9514999
1x70/160.2772652834.530.38501485
1x120/160.16437132.539.535.113302081
1x240/250.081757439.54742.325813454
1x240/500.081757440.54843.227983682
1x300/250.0654660425044.831754444
(N)TMCWOEU 18/30 kV – Test Voltage 43 kV
1x25/160.7951392733.529.34281203
1x120/160.1643713744.539.713352341
1x240/250.081757442.55145.825813703
1x300/250.06546604553.548.331474450
1x630/350.0292–––64.364448653
(N)TMCWOEU 26/45 kV – Test Voltage 87 kV
1x35/160.56517234.54237.65141441
1x50/160.393216374540.36581730
1x70/160.27726538.547428502150
1x95/160.2131940.548.543.710902415
1x120/160.1643714250.545.413302850
1x150/250.13242843.55247.117173240
1x185/250.10848845.55448.820533600
1x240/250.0817574495852.625814300
1x300/25*0.065466051.560.555.12699*5113
1x400/350.0495790556157.742356326
Technical Note: Current ratings refer to installation in air at 30°C, with ampacity according to VDE 0298-4. Outer diameters are approximate. Copper weight follows the German Cu GER convention. Cable weights are expressed in kg/km and exclude drums and packaging. Missing values are shown as a dash. The reference temperature for conductor resistance is not explicitly specified.
Data Verification: The current rating and minimum/maximum outer diameters for 1x630/35 at 18/30 kV are not specified. *The stated copper weight of 2699 kg/km for 1x300/25 at 26/45 kV requires manufacturer confirmation. All technical data must be confirmed for the supplied product.

Technical Documentation

Technical Data Sheet

EU declaration of conformity

Core Identification

Send Us email - RFQ


UNIMA CABLE COLLECTION

Explore Our Cable Range

Discover cable types, technical specifications and solutions for your projects.

80 Cable Types Available