Find Your Cable

Select a cable or enter another designation.


UNIMA CABLE | OVERHEAD POWER CABLES

NFA2X – Aerial Bundled Aluminium Cable (ABC)

Low voltage aerial bundled power cable with stranded aluminium conductors and PE TIX 2 insulation, designed for overhead electricity distribution and above-ground service connections.

0.6/1 kV Aluminium Class 2 PE TIX 2 Aerial Bundled Cable Overhead Distribution HD 626 S1 CPR Fca

Product Overview

NFA2X is a low voltage aerial bundled cable designed for overhead electrical distribution networks in urban, suburban and rural areas.

Both phase and neutral conductors are manufactured from Class 2 stranded aluminium according to EN 60228 and individually insulated with PE TIX 2 compound.

The cable is suitable for supplying remote facilities, villages and temporary or permanent installations, including above-ground connections to residential buildings.

The product range includes two-core, three-core, four-core and five-core configurations, as well as variants with additional conductors.

Key Technical Features

0.6/1 kVRated Voltage
+80°CMax. Conductor Temperature
+130°CShort-Circuit Temperature
18 × DMinimum Bending Radius

Construction & Technical Properties

Cable Construction

Phase ConductorsAluminium, Class 2
Neutral ConductorsAluminium, Class 2
InsulationPE Compound TIX 2
Insulation ColourBlack
Core IdentificationBy Ridges
Identification MethodHD 626-1, Method A
Cable ConfigurationAerial Bundled Conductors
Conductor Range16–185 mm²

Electrical & Mechanical Data

Rated Voltage0.6/1 kV
Test Voltage4 kV
Max. Conductor Temp.+80°C
Short-Circuit Temp.+130°C
Operating Temperature-40°C to +50°C
Min. Laying Temperature-10°C
Min. Bending Radius18 × D
CPR ClassFca

Typical Applications

Low Voltage Overhead Distribution
Urban Electricity Networks
Suburban Electricity Networks
Rural Electrification
Above-Ground House Connections
Remote Facility Power Supply
Temporary Overhead Installations
Permanent Overhead Installations

Applicable Standards

VDE 0276-626 – Low voltage overhead distribution cables.
HD 626 S1 – Overhead distribution cables of rated voltage 0.6/1 kV.
EN 60228 – Conductors of insulated cables.
HD 626-1, Method A – Core identification by ridges.
Technical & Installation Note: NFA2X is intended for overhead power distribution. Installation must comply with applicable electrical and mechanical requirements. CPR class Fca is stated in the reference technical specification and must be confirmed for the supplied product. Cable dimensions, packing and technical characteristics are subject to manufacturing tolerances.
UNIMA CABLE | TECHNICAL DIMENSIONS

NFA2X – Cable Sizes & Technical Data

46 reference cable configurations with conductor resistance, current capacity in air, aluminium weight, total cable weight and standard packing information.

46Reference Configurations
16–185 mm²Conductor Range
0.6/1 kVRated Voltage
500–1000 mReference Drum Length

Available Cable Sizes

Size (mm²) Resistance 20°C (Ω/km) Current Air (A) Aluminium Weight (kg/km) Cable Weight (kg/km) Drum Type Drum Length (m)
2-Core Cables
2x161.918392.8131N91000
2x251.20107145192N121000
2x350.868132203261N121000
2x500.641165290346N131000
2x700.443213406530N151000
2x950.320258551691N161000
2x1200.253300696847N161000
2x1500.2063448701030N15500
3-Core Cables
3x161.9183139.2196N111000
3x251.20107217.5288N121000
4-Core Cables and Additional Conductor Configurations
4x161.9183185.6261N111000
4x251.200107290384N131000
4x25+161.200/1.910107336.4449N131000
4x25+2x161.200/1.910107382.8514N131000
4x350.868132406523N12500
4x35+160.868/1.910132452.4589N12500
4x35+2x160.868/1.910132498.8654N12500
4x35+250.868/1.200132478.5595N12500
4x500.641165580692N13500
4x50+250.641/1.200165652.5788N13500
4x50+350.641/0.868165681.5823N13500
4x50+2x160.614/1.910*165672.8860N14500
4x50+2x250.641/1.200165725884N14500
4x50+2x350.641/0.868165783954N14500
4x700.443205812935N14500
4x70+160.443/1.910205858.41000N14500
4x70+2x160.443/1.910205904.81066N14500
4x70+250.443/1.200205884.51031N13500
4x70+2x250.443/1.2002059571066N14500
4x70+350.443/0.868205913.51127N15500
4x70+2x350.443/0.86820510151197N15500
4x950.32025811021296N15500
4x95+250.320/1.2002581174.51392N15500
4x95+350.320/0.8682581203.51427N15500
4x95+2x160.320/1.9102581194.81455N15500
4x95+2x250.320/1.20025812471488N15500
4x95+2x350.320/0.86825813051558N15500
4x1200.25330013921635N16500
4x120+250.253/1.2003001464.51731N16500
4x120+350.253/0.8683001493.51766N16500
4x120+2x250.253/1.20030015371827N16500
4x120+2x350.253/0.86830015951896N16500
4x1500.20634417401867N18500
4x1850.16439521462362N20500
5-Core Cables
5x161.91083232311N121000
5x251.200107362.5362.5*N121000
Technical Note: Aluminium weight and approximate net cable weight are expressed in kg/km. Cable weight excludes drums and packaging. Resistance values are maximum DC conductor resistance values at 20°C. Where two resistance values are stated, they refer to the different conductor cross-sections. Current capacities and packing information are reference values and must be confirmed for the supplied product.

*Values requiring confirmation: The reference resistance for 4x50+2x16 and the total cable weight for 5x25 require technical confirmation before use in engineering or logistics calculations.

Technical Documentation

Technical Data Sheet

EU declaration of conformity

Core Identification

UNIMA CABLE

NFA2X Cable Calculator

Calculate cable weight, copper content and approximate cable length.

m
Cable Weight 0 kg
Cable Length 0 m
Copper Content 0 kg
Copper Share 0 %
Cable weight: 0 kg/km
Copper: 0 kg/km
Approximate values based on technical cable data. Actual values may vary due to manufacturing tolerances.

Send Us email - RFQ


UNIMA CABLE COLLECTION

Explore Our Cable Range

Discover cable types, technical specifications and solutions for your projects.

80 Cable Types Available