(N)2XY FR (IEC) 0.6/1 kV – Flame Retardant Copper Power Cable

Low-voltage power cable with bare copper conductors, XLPE DIX3 insulation and a black, UV-resistant PVC ST2 outer sheath. Flame retardant according to IEC 60332-3-24, Category C.

0.6/1 kV Copper XLPE DIX3 PVC ST2 Flame Retardant IEC 60502 UV Resistant

Product Overview

(N)2XY FR (IEC) is a low-voltage power cable designed for fixed electrical installations in buildings, outdoors, underground and in water.

The cable features bare copper conductors with cross-linked polyethylene (XLPE DIX3) insulation and a black PVC ST2 outer sheath providing UV resistance and flame-retardant properties.

The maximum permissible conductor temperature is +90°C. Resistance to vertical flame propagation is specified according to IEC 60332-3-24, Category C.

Key Technical Features

0.6/1 kVRated Voltage
+90°CMax. Conductor Temperature
4 kVTest Voltage
Cat. CFlame Propagation Test

Construction & Technical Properties

Cable Construction

ConductorBare Copper
Conductor ClassClass 1; Class 2 from 25 mm²
InsulationXLPE DIX3
Outer SheathPVC ST2
Sheath ColourBlack
Core IdentificationVDE 0293 / HD 308
UV ResistanceYes
Reference Configuration(N)2XY-O 1x240 RMv

Electrical & Mechanical Data

Rated Voltage0.6/1 kV
Max. System Voltage1.2 kV (Three-Phase)
Test Voltage4 kV
Max. Conductor Temp.+90°C
Fixed Cable Temp.-35°C to +70°C
Moved Cable Temp.-5°C to +70°C
Min. Bending Radius15 × D (Fixed)
Flame RetardancyIEC 60332-3-24, Cat. C

Typical Applications

Low-Voltage Power Distribution
Fixed Building Installations
Outdoor Electrical Installations
Underground Cable Installations
Installation in Water
Fixed Industrial Power Installations

Applicable Standards

IEC 60502 – Power cables with extruded insulation.
IEC 60332-3-24 (Category C) – Vertical flame propagation test for bunched cables.
VDE 0482-266-2-4 – Flame propagation testing.
VDE 0293 / HD 308 – Core identification.
Technical Note: The FR designation refers to flame-retardant properties and does not indicate fire-resistant circuit integrity or halogen-free construction. CPR classification is subject to confirmation by the applicable Declaration of Performance. Dimensions and weights are reference values and may vary by manufacturer.
UNIMA CABLE | TECHNICAL DIMENSIONS

(N)2XY FR (IEC) – Cable Sizes & Technical Data

Reference cable dimensions, conductor resistance, current ratings, insulation thickness, copper weight and total cable weight per kilometre.

Cable Sizes

Size (mm²) Resistance (Ω/km) Insulation Thickness (mm) Current Air 30°C (A) Current Ground 20°C (A) Outer Diameter (mm) Copper Weight (kg/km) Cable Weight (kg/km)
(N)2XY-O FR – Single-Core Cable
1x240 RMv 0.0754 1.7 604 517 27.7 2304 2560
Technical Note: Current ratings refer to air at 30°C and ground at 20°C. Outer diameter is approximate. Copper weight is the reference copper weight (GER), while cable weight represents the net cable weight per 1,000 metres. Actual dimensions, weights and permissible current ratings may vary depending on manufacturing tolerances and installation conditions. Availability is subject to confirmation.