(N)2XCY 0.6/1 kV – Copper Power Cable

XLPE insulated power cable with bare copper conductors, concentric copper conductor and black PVC outer sheath. Designed for fixed low-voltage power distribution installations.

0.6/1 kV Copper Conductor XLPE Insulation Concentric Copper PVC Sheath CPR Eca

Product Overview

(N)2XCY 0.6/1 kV is a low-voltage power cable featuring bare copper conductors insulated with cross-linked polyethylene (XLPE DIX3).

A concentric copper conductor surrounds the insulated cable core assembly and is protected by a black PVC DMV5 outer sheath.

The cable is intended for fixed power distribution installations where a concentric copper conductor is required. Its XLPE insulation provides a robust construction for electrical installations.

Key Technical Features

0.6/1 kV Rated Voltage
Cu + Cu Conductor Materials
21.1 mm Reference Outer Diameter
Eca Reference CPR Class

Construction & Technical Properties

Cable Construction

Main Conductor Bare Copper (Cu)
Conductor Shape RE – Round Solid
Insulation XLPE DIX3
Concentric Conductor Copper (Cu)
Outer Sheath PVC DMV5
Sheath Colour Black
Reference Size 4x16 RE/16 mm²

Electrical & Mechanical Data

Rated Voltage 0.6/1 kV
Insulation Material Cross-Linked Polyethylene
Reference Diameter 21.1 mm
Copper Weight 796 kg/km
Total Cable Weight 1,039 kg/km
CPR Classification Eca – Reference
Cable Standard VDE 0276-603 (Reference)

Typical Applications

Low-Voltage Power Distribution
Fixed Electrical Installations
Industrial Power Supply
Building Electrical Infrastructure
Installations Requiring a Concentric Copper Conductor
Permanent Power Cable Networks

Applicable Standards

VDE 0276-603 – Referenced cable construction standard.
EN 50575 – CPR reaction-to-fire classification (reference class Eca).
Technical Note: The listed dimensional and weight values refer to the 4x16 RE/16 mm² configuration. Copper weight includes the copper components of the cable. Dimensions and weights are approximate manufacturer reference values. CPR classification must be verified against the Declaration of Performance (DoP) for the cable actually supplied.
UNIMA CABLE | TECHNICAL DIMENSIONS

(N)2XCY – Cable Dimensions & Weight Calculator

Technical dimensions and copper weight for the (N)2XCY 0.6/1 kV cable. Calculate the total cable and copper weight for your required length.

Technical Size Table

Cable Size Outer Diameter (mm) Copper Weight (kg/km) Cable Weight (kg/km)
4x16 RE/16 21.1 796 1,039
Showing 1 cable configuration

Cable Weight Calculator

Selected Cable: 4x16 RE/16 mm²
1,039 Total Cable Weight (kg)
796 Copper Weight (kg)
1,000 Selected Length (m)
Technical Note: Copper weight includes the copper conductors and concentric copper conductor. Weight values are calculated from reference weights per 1,000 metres. Actual dimensions and weights may vary according to manufacturer tolerances.

Technical Documentation

Technical Data Sheet

EU declaration of conformity