H07V-U – Solid PVC Insulated Single Core Wire


Technical Specifications

  • H07V-U
  • Cable Type
  • Building wiring, Electrical installations, Distribution boards, Switchboards
  • Application
  • EN 50525-2-31, IEC 60227-3, IEC 60228 Class 1
  • Standard

Details

  • Insulation Material PVC (TI1)
  • Packaging 100 m & 200 m coils, 500 m drums
  • Availability Stock
  • Number of cores: 1
  • Cross sections: 1.5mm² to 10mm²
  • Available Colours: Black, Brown, Blue, Grey, Green/Yellow, Red, White, Orange, Violet
  • Conductor: Class 1 solid bare copper
  • Conductor Material Solid Bare Copper (Class 1)
  • Cable Group Building wires
  • Insulation Material PVC (TI1)
  • Rated Voltage 450/750 V
  • CPR Class Eca (where applicable)
  • Standard EN 50525-2-31, IEC 60227-3, IEC 60228 Class 1

The H07V-U is a harmonised single-core electrical wire with a Class 1 solid bare copper conductor and PVC insulation. It is intended for fixed installation inside conduits, closed cable ducts, electrical panels and distribution boards in residential, commercial and industrial buildings. The cable is suitable for laying in pipes installed on or under plaster and for internal wiring of machinery, switchgear and distribution systems.

H07V-U is commonly used for protected fixed wiring in residential buildings, commercial facilities and industrial electrical installations. Typical applications include electrical cabinets, switchboards, distribution boards, control panels, machinery wiring and wiring installed inside conduits or closed cable ducts.

The cable has a rated voltage of 450/750 V and PVC TI1 insulation. It is flame-retardant according to IEC 60332-1-2 and classified Eca according to EN 50575. The maximum conductor operating temperature is 70°C, while the minimum bending radius for fixed installation is four times the cable outer diameter. H07V-U is not intended for direct laying under plaster.

450/750 V
Rated Voltage
Class 1
Solid Copper
1.5–16 mm²
Cross Sections
EN 50525-2-31
Standard
CPR Eca
Fire Classification
H07V-U Technical Data
Cross-section
mm²
Conductor Ø
mm
Conductor
Resistance
Ω/km @ 20°C
Insulation
Thickness
mm
Ampacity
in Air
A @ 30°C
Min. Bending
Radius
mm
Outer
Diameter
approx. mm
Copper
Weight
kg/km
Cable
Weight
kg/km
1 × 1.5 1.5 12.1 0.7 24 10.8 2.7 14.4 20
1 × 2.5 1.9 7.41 0.8 32 13.2 3.3 24 31
1 × 4 2.4 4.61 0.8 42 15.2 3.8 38 46
1 × 6 2.9 3.08 0.8 54 17.2 4.3 58 65
1 × 10 3.7 1.83 1.0 73 22.0 5.5 96 110
1 × 16* 4.6 1.15 1.0 98 25.6 6.4 154 170
* 1 × 16 mm² listed with reference to VDE. Ampacity values apply to installation in air at 30°C. Dimensions and weights are approximate.

Technical Documentation

Maximum 2 cross-sections per Data Sheet. 1 selected
UNIMA CABLE

H07V-U Cable Calculator

Solid PVC Insulated Single Core Wire

Calculate cable weight, copper content and approximate cable length.

m
Cable Weight 0 kg
Cable Length 0 m
Copper Content 0 kg
Copper Share 0 %
Cable weight: 0 kg/km
Copper: 0 kg/km
Approximate values based on technical cable data. Actual values may vary due to manufacturing tolerances.
distributor wire and cable 35kv sourcing
Unima d.d.

Why Unima Cable?

B2B partner for cable distribution across Europe and global industrial projects

Years of Experience
0 +
Fast Delivery
0 +h
Technical Documentation Files
0 +
Markets Served
0 +