The Cat. 7 S/FTP cable is a high-performance 4-pair data cable designed for structured Class F networks and high-speed voice and data transmission. Each twisted pair is individually screened with aluminium-laminated foil, while the complete cable is protected by a tinned copper braid for enhanced electromagnetic interference protection.
UNIMA CABLE | DATA & COMMUNICATION
Cat. 7 S/FTP – HF1 Violet
High-performance Category 7 shielded data cable designed for structured cabling systems, high-speed data transmission and demanding network installations. The cable features four individually foil-screened twisted pairs with an overall braided screen for enhanced electromagnetic interference protection.
Category 7
S/FTP
4 × 2 × AWG23
100 Ω
600 MHz Specified
1000 MHz Rated
CPR Eca
Violet Sheath
Cat. 7
Cable Category
600 MHz
Specified Frequency
100 Ω
Nominal Impedance
7.0 mm
Nominal Outer Diameter
50.2 kg/km
Approximate Cable Weight
Eca
Reaction to Fire
Construction
- Conductor: Copper, AWG23
- Pair configuration: 4 twisted pairs / 8 conductors
- Individual screening: Foil screen around each pair
- Overall screening: Braided screen
- Screening type: S/FTP
- Outer sheath colour: Violet / Purple
- Nominal outer diameter: 7.0 mm
Applications
- Structured cabling systems
- High-speed Ethernet networks
- Commercial and office buildings
- Data centres and server rooms
- Industrial data communication
- Telecommunications infrastructure
- Shielded network installations
Technical Characteristics
Cable Designation
Cat. 7 S/FTP HF1
Conductor Configuration
4 × 2 × AWG23
Nominal Impedance
100 Ω
Impedance at 100 MHz
100 Ω ± 5 Ω
Specified Frequency
600 MHz
Rated Frequency
1000 MHz
Operating Temperature
-20°C to +75°C
Installation Temperature
0°C to +50°C
Minimum Bending Radius – Installed
4 × D
Minimum Bending Radius – Installation
8 × D
Outer Diameter
7.0 mm
Cable Weight
50.2 kg/km
CPR Classification
Eca
Outer Sheath Colour
Violet
Electrical Performance
Conductor Loop Resistance
Max. 19 Ω/100 m
Resistance Unbalance
Max. 2%
Insulation Resistance
> 5 GΩ·km
Dielectric Strength
2500 V DC / 2 s
Propagation Delay at 100 MHz
413 ns/100 m
Delay Skew at 100 MHz
4 ns/100 m
Nominal Velocity of Propagation
0.80
Coupling Attenuation
90 dB
Transfer Impedance at 10 MHz
8 mΩ/m
Installation Guidelines
- Suitable for fixed structured cabling installations.
- Maintain the specified bending radius during installation and in the final installed position.
- Use compatible shielded connectivity components and maintain screening continuity.
- Avoid excessive tensile force, crushing and mechanical damage during installation.
- Verify the complete channel performance according to the applicable network requirements.
Product Information:
Technical characteristics refer to the selected
Cat. 7 S/FTP HF1 violet cable variant.
UNIMA CABLE acts as distributor.
Product-specific declarations and certificates
must correspond to the actual supplied cable.
Values are subject to the manufacturer's
technical documentation.
05
Nominal Transmission Characteristics
Cat. 7 S/FTP HF1 Violet | Typical performance at 20°C
Category 7 S/FTP cable specified to 600 MHz and
rated to 1000 MHz. The tables below distinguish
standard performance limits from typical
manufacturer performance.
Standard: IEC/TIA/EN limits
Typical: Manufacturer performance at 20°C
N/A: No standard limit stated
| FrequencyMHz | Insertion LossdB/100 m · Typical | NEXTdB · Typical | PSNEXTdB · Typical | ACR-FdB · Typical | PSACR-FdB · Typical | Return LossdB · Typical | PSANEXTdB · Typical | PSAACR-FdB · Typical |
|---|---|---|---|---|---|---|---|---|
| 1 | 1.9 | 100.0 | 97.0 | 103.9 | 100.9 | 27.0 | 100.0 | 98.0 |
| 4 | 3.5 | 100.0 | 97.0 | 103.9 | 100.9 | 33.1 | 100.0 | 96.4 |
| 10 | 5.5 | 100.0 | 97.0 | 102.8 | 99.8 | 34.0 | 100.0 | 94.3 |
| 100 | 18.0 | 100.0 | 97.0 | 89.4 | 86.4 | 39.3 | 100.0 | 81.5 |
| 200 | 25.7 | 100.0 | 97.0 | 78.2 | 75.2 | 38.4 | 100.0 | 73.2 |
| 250 | 28.7 | 100.0 | 97.0 | 74.6 | 71.6 | 34.4 | 100.0 | 68.8 |
| 500 | 41.1 | 100.0 | 97.0 | 65.2 | 62.2 | 28.7 | 100.0 | 55.9 |
| 600 | 45.5 | 95.0 | 92.0 | 55.2 | 52.2 | 27.1 | 100.0 | 51.1 |
| 1000 | 60.9 | 89.0 | 86.0 | 50.8 | 47.8 | 24.6 | 100.0 | 34.7 |
Standard Performance Limits
| FrequencyMHz | Insertion LossMax. dB/100 m | NEXTMin. dB | PSNEXTMin. dB | ACR-FMin. dB | PSACR-FMin. dB | Return LossMin. dB |
|---|---|---|---|---|---|---|
| 1 | 2.0 | 80.0 | 77.0 | 80.0 | 77.0 | 20.0 |
| 4 | 3.7 | 80.0 | 77.0 | 80.0 | 77.0 | 23.0 |
| 10 | 5.9 | 80.0 | 77.0 | 74.0 | 71.0 | 25.0 |
| 100 | 19.0 | 72.4 | 69.4 | 54.0 | 51.0 | 20.1 |
| 200 | 27.5 | 67.9 | 64.9 | 48.0 | 45.0 | 18.0 |
| 250 | 31.0 | 66.5 | 63.5 | 46.0 | 43.0 | 17.3 |
| 500 | 45.3 | 61.9 | 58.9 | 40.0 | 37.0 | 17.3 |
| 600 | 50.1 | 60.8 | 57.8 | 38.4 | 35.4 | 17.3 |
| 1000 | N/A | N/A | N/A | N/A | N/A | N/A |
Additional Electrical Parameters
Conductor Loop Resistance
Max. 19 Ω/100 m
Conductor Resistance Unbalance
Max. 2%
Insulation Resistance
> 5 GΩ·km
Dielectric Strength
2500 V DC / 2 s
Typical Propagation Delay at 100 MHz
413 ns/100 m
Typical Delay Skew at 100 MHz
4 ns/100 m
Typical Coupling Attenuation
90 dB
Typical Transfer Impedance at 10 MHz
8 mΩ/m
Technical Notes:
Typical values are manufacturer reference measurements
at 20°C. Standard values represent applicable
performance limits. At 1000 MHz, the source
does not specify standard limits (N/A).
Actual installed channel performance depends on
installation conditions, connectors and testing.
Product variant: Cat. 7 S/FTP HF1 Violet, 4 × 2 × AWG23, nominal outer diameter 7.0 mm, approximate weight 50.2 kg/km.
Product variant: Cat. 7 S/FTP HF1 Violet, 4 × 2 × AWG23, nominal outer diameter 7.0 mm, approximate weight 50.2 kg/km.