U-1000 AR2V Aluminium Power Cable

Unima Cable


Technical Specifications

  • Aluminium Power Cable
  • Cable Type
  • Power Distribution, Industrial, Infrastructure, Buildings, Underground Installation
  • Application
  • NF C 32-321, IEC 60502-1
  • Standard

Details

  • Property ID U-1000 AR2V
  • Insulation Material XLPE
  • Packaging Wooden Drums
  • Availability On Request
  • Available Cross Sections 10 mm² to 630 mm², depending on core configuration
  • Number of Cores 1 to 5 cores, including reduced neutral configurations
  • Conductor Class Class 2 – EN 60228
  • Test Voltage 4 kV
  • Maximum Conductor Temperature +90°C
  • Minimum Laying Temperature -5°C
  • Outer Sheath Black PVC
  • Core Identification According to HD 308 S2
  • Property ID U-1000 AR2V
  • Conductor Material Aluminium, Class 2 Stranded
  • Cable Group Power cables 1 - 30 kV
  • Insulation Material XLPE
  • Rated Voltage 0.6/1 kV
  • CPR Class Eca – EN 50575
  • Standard NF C 32-321, IEC 60502-1

The U-1000 AR2V cable is a 0.6/1 kV power cable with Class 2 aluminium conductors, XLPE insulation and a PVC outer sheath. It is designed for low-voltage energy distribution in industrial installations, urban networks, buildings and infrastructure applications.

Suitable for fixed indoor and outdoor installation, including installation in raceways and cable constructions. The cable can also be laid underground when appropriate mechanical protection is provided. It offers good resistance to solar radiation, atmospheric conditions, low temperatures and chemical agents.

0.6/1 kV
RATED VOLTAGE
Class 2
ALUMINIUM
10–630 mm²
CONDUCTOR SIZES
XLPE
INSULATION
Eca
CPR CLASS
TECHNICAL SPECIFICATIONS

U-1000 AR2V Technical Data

Cable Construction

Conductor
Aluminium
Class 2 stranded
Insulation
XLPE compound
Bedding
Extruded elastomer or plastomer compound
Outer Sheath
Black PVC compound
Core Identification
HD 308 S2
Bending Radius
15 × Ø single-core
12 × Ø multi-core
Test Voltage
4 kV
Water Protection
AD7

Cable Configurations and Dimensions

Cable Formation
n × mm²
Conductor
Shape
Max. Resistance
Ω/km @ 20°C
Insulation
Thickness
mm
Insulated Core
Diameter
mm
Max. Outer
Diameter
mm
Aluminium
Weight
kg/km
Approx. Cable
Weight
kg/km
1 CORE
1 × 16RM1.9100.76.18.346.4114
1 × 25RM1.2000.97.69.872.5161
1 × 35RM0.8680.98.810.9101.5202
1 × 50RM0.6411.010.012.4145.0266
1 × 70RM0.4431.111.814.0203.0347
1 × 95RM0.3201.113.615.6275.5439
1 × 120RM0.2531.215.217.4348.0547
1 × 150RM0.2061.416.719.2435.0671
1 × 185RM0.1641.619.021.3536.5826
1 × 240RE0.1251.720.323.3696.01035
1 × 240RM0.1251.721.323.9696.01045
1 × 300RM0.10001.824.126.3870.01280
1 × 400RM0.07782.026.630.01160.01671
1 × 500RM0.06052.230.333.21450.02062
1 × 630RM0.04692.434.137.11827.02581
2 CORE
2 × 10RM3.0800.75.116.059.2290
2 × 16RM1.9100.76.118.594.7330
2 × 25RM1.2000.97.622.0148.0520
2 × 35RM0.8680.98.824.5207.2649
3 CORE
3 × 10RM3.0800.75.117.088.8266
3 × 16RM1.9100.76.119.5142.1410
3 × 25RM1.2000.97.623.5222.0602
3 × 35RM0.8680.98.826.0310.8740
3 × 50RM0.6411.010.029.0444.0940
3 × 70RM0.4431.111.834.0621.61322
3 × 95RM0.3201.113.638.5843.61681
3 × 120RM0.2531.215.242.51065.62144
3 × 150RM0.2061.416.747.51332.02622
3 × 185RM0.1641.619.053.01642.83249
3 × 240RM0.1251.721.359.52131.24154
3 × 300RM0.1001.824.166.02664.05070
3 CORE + REDUCED CONDUCTOR
3 × 50 + 35RM0.6411.0 / 0.910 / 8.828.9536.51096
3 × 70 + 50RM0.4431.1 / 1.011.8 / 1033.5754.01490
3 × 95 + 50RM0.3201.1 / 1.013.6 / 1036.6971.51867
3 × 120 + 70RM0.2531.2 / 1.115.2 / 11.840.71247.02313
3 × 150 + 70RM0.2061.4 / 1.116.7 / 11.844.61508.02841
3 × 185 + 70RM0.1641.6 / 1.119 / 11.848.41812.53444
3 × 240 + 95RM0.1251.7 / 1.121.3 / 13.654.52363.54395
4 CORE
4 × 10RM3.0800.75.118.5118.4370
4 × 16RM1.9100.76.121.0189.4485
4 × 25RM1.2000.97.625.5296.0710
4 × 35RM0.8680.98.828.5414.4890
4 × 50RM0.6411.010.032.5592.01115
4 × 70RM0.4431.111.837.5828.91576
4 × 95RM0.3201.113.642.51124.82039
4 × 120RM0.2531.215.247.51420.82402
4 × 150RM0.2061.416.752.51776.03010
4 × 185RM0.1641.619.059.02190.43932
4 × 240RM0.1251.721.366.52841.64901
4 × 300RM0.1001.824.173.53552.06124
5 CORE
5 × 10RM3.0800.75.120.0148.0366
5 × 16RM1.9100.76.123.0236.8577
5 × 25RM1.2000.97.628.0370.0850
5 × 35RM0.8680.98.829.416802236
5 × 50RM0.6411.010.031.624003116
5 × 70RM0.4431.111.836.433604287
5 × 95RM0.3201.113.640.645605661
Technical data: Dimensions, aluminium content and cable weights are nominal or approximate values and may vary within normal manufacturing tolerances.

Installation Conditions

U-1000 AR2V is suitable for fixed indoor and outdoor installation, installation in raceways and cable constructions, and for low-voltage energy distribution in industrial, urban and building installations. Underground installation is permitted when suitable mechanical protection is provided. The cable offers good resistance to solar radiation, atmospheric conditions, low temperatures and chemical agents.

Electrical & Temperature Characteristics

Rated Voltage U₀/U 0.6/1 kV
Test Voltage 4 kV
Minimum Laying Temperature -5°C
Maximum Operating Temperature +90°C
Maximum Short-Circuit Temperature +250°C
Water Protection AD7

Standards & Compliance

Product Standard: NF C32-321
Low Voltage Power Cable: IEC 60502-1
Conductor: EN 60228, Class 2
Core Identification: HD 308 S2
CPR Classification: Eca

Technical dimensions, conductor weights and cable weights are nominal or approximate values and may be subject to manufacturing tolerances. Product specifications may be updated without prior notice.

Technical Documentation

Technical Data Sheet

EU declaration of conformity

Core Identification

distributor wire and cable 35kv sourcing
Unima d.d.

Why Unima Cable?

B2B partner for cable distribution across Europe and global industrial projects

Years of Experience
0 +
Fast Delivery
0 +h
Technical Documentation Files
0 +
Markets Served
0 +