H07RN-F – Heavy Duty Rubber Flexible Cable

Unima Cable


Technical Specifications

  • Heavy Duty Rubber Flexible Cable
  • Cable Type
  • Construction, Industrial Machinery, Mobile Equipment, Pumps, Outdoor Use
  • Application
  • DIN EN 50525-2-21 (VDE 0285-525-2-21)
  • Standard

Details

  • Property ID H07RN-F
  • Insulation Material EPR Rubber EI4
  • Availability Stock
  • Number of Cores: 1 to 7, Multiple corse available
  • Available Cross Sections: 1.0 mm² to 630 mm², depending on core configuration
  • Number of Cores 1 to 25 cores, depending on cross section
  • Test Voltage 2.5 kV
  • Temperature Range -25°C to +55°C
  • Max. Conductor Temperature +85°C
  • Oil Resistance Yes – DIN EN 60811-404
  • UV Resistance and Ozone Resistance Yes
  • Outdoor Use Yes
  • Flame Retardant IEC 60332-1-2
  • Core Identification VDE 0293 (HD 308)
  • Bending Radius 3–4 × Ø fixed / 5–6 × Ø flexible
  • Property ID H07RN-F
  • Conductor Material Bare Copper, Class 5 Fine Stranded
  • Cable Group Flexible wires
  • Insulation Material EPR Rubber EI4
  • Rated Voltage 450/750 V
  • CPR Class Eca – EN 50575
  • Standard DIN EN 50525-2-21 (VDE 0285-525-2-21)
450/750 V
RATED VOLTAGE
Class 5
FLEXIBLE COPPER
EPR EI4
INSULATION
CR EM2
OUTER SHEATH
Eca
CPR CLASS

H07RN-F Cable Technical Data

H07RN-F is a heavy-duty flexible rubber cable designed for medium mechanical stress in dry, damp and wet locations as well as outdoor applications. The cable features flexible Class 5 bare copper conductors, EPR EI4 rubber insulation and a CR EM2 rubber outer sheath.

Application

Suitable for medium mechanical stress in dry, wet and damp locations and for outdoor use. H07RN-F can also be used for fixed installation on plaster or machinery. The cable is resistant to oil, UV radiation and ozone.

Construction & Properties

Conductor
Bare copper, Class 5 fine stranded
Insulation
EPR rubber, EI4
Outer Sheath
CR rubber, EM2
Test Voltage
2.5 kV
Conductor Temperature
Max. +85°C
Cable Temperature
-25°C to +55°C
Oil Resistant
Yes
UV & Ozone Resistant
Yes

H07RN-F Sizes & Technical Characteristics

Formation Resistance
Ω/km
Ampacity
A
Outer Ø
mm
Tensile
N
Copper
kg/km
Cable Weight
kg/km
1 CORE
1 X 1.513.316.55.92314.448
1 X 2.57.98226.6382464
1 X 44.95307.4603888
1 X 63.3388.19058113
1 X 101.91539.715096184
1 X 161.217111.0240154250
1 X 250.789412.9375240364
1 X 350.55411714.6525336472
1 X 500.38614816.8750480660
1 X 700.27218518.91050672876
1 X 950.20622221.114259121131
1 X 1200.16126023.1180011521408
1 X 1500.12930025.6225014401738
1 X 1850.10634127.9277517762087
1 X 2400.080140731.0360023042705
1 X 3000.064146834.1450028803314
1 X 4000.048655338.5600038404264
1 X 5000.038463443.5750048005431
1 X 6300.028774248.5945060486849
2 CORE
2 X 119.5157.8301991
2 X 1.513.318.58.74529113
2 X 2.57.982510.47548159
2 X 44.953412.012077220
2 X 63.34313.3180115276
3 CORE
3 X 119.512.58.4452990
3 G 119.515.58.44529111
3 X 1.513.315.59.46843155
3 G 1.513.319.59.46843139
3 X 2.57.982111.111372139
3 G 2.57.982611.111372199
3 G 44.953512.9180115277
3 X 63.33614.3270173354
3 G 63.34414.3270173354
3 X 101.915119.3450288654
3 G 101.916219.3450288654
3 X 161.216722.1720461903
3 G 161.218222.1720461903
3 X 250.788927.011257201250
3 G 250.7810927.011257201250
3 X 350.55411029.6157510081733
3 G 350.55413529.6157510081755
3 G 500.38616936.0225014403790
4 CORE
4 G 119.5139.56038129
4 G 1.513.31610.49058170
4 G 2.57.982212.315096246
4 G 44.953014.2240154338
4 G 63.33715.9360230450
4 X 101.915221.3600384817
4 G 101.915221.3600384817
4 X 161.216924.2960614.41122
4 G 161.216924.29606141122
4 X 250.789229.315009601660
4 G 250.789229.315009601660
4 G 350.55411433.0210013442181
4 G 500.38614338.2300019203034
4 G 700.27217843.2420026884062
4 G 950.20621049.0570036485263
4 G 1200.16124653.6720046086447
4 G 1500.12928258.7900057607857
4 G 1850.10631965.01110071049504
4 G 2400.080137774.014400921612434
5 CORE
5 G 1.513.316.511.511372208
5 G 2.57.982313.5188120300
5 X 2.57.981713.5188120340
5 G 44.953015.9300192428
5 G 63.33817.9450288563
5 G 101.915422.3750480994
5 G 161.217126.912007681378
5 G 250.789432.5187512002041
5 G 350.55411738.0262516802660
5 G 500.38614844.5375024003768
5 G 700.27218547.0525033604893
5 G 950.20622258.0712545606463
5 G 120*0.16124661.0900057608025
5 G 150*0.12928273.011250720010017
5 G 185*0.10631974.813875888012080
5 G 240*0.080137781.9180001152015230
MULTICORE
7 G 1.513.315.514.5158101338
7 G 2.57.982117.0263168478
7 G 44.952925.8420269697
7 G 6*3.33622.5630403.2915
10 G 1.513.315.517.2225144457
12 G 1.513.315.518.3270175450
12 G 2.57.982119.0450288695
18 G 2.57.982126.06754321032
19 G 1.513.315.523.5428274715
19 G 2.57.982126.67134561020
24 G 1.513.315.525.5540346905
24 G 2.57.982131.59005761302
25 G 1.513.315.526.0563360889
Technical data: Rl = conductor resistance; Ampacity = current carrying capacity in air; Ø = approximate outer diameter; Tensile = tensile strength during installation; Copper = copper weight; Cable Weight = net cable weight per 1000 m.

* Configurations marked with an asterisk are listed by the manufacturer as “with reference to”. Outer diameters are approximate.

Standards & Compliance

Product Standard: DIN EN 50525-2-21 (VDE 0285-525-2-21)
Conductor: DIN EN IEC 60228 (VDE 0295), Class 5
CPR Classification: EN 50575 – Eca
Flame Retardant: VDE 0482-332-1-2 / IEC 60332-1-2
Oil Resistance: DIN EN 60811-404 / VDE 0473-811-404 / IEC 60811-404
Core Identification: VDE 0293 (HD 308)

Technical Documentation

UNIMA CABLE

H07RN-F Cable Calculator

Heavy Duty Rubber Flexible Cable

Calculate cable weight, copper content and approximate cable length.

m
Cable Weight 0 kg
Cable Length 0 m
Copper Content 0 kg
Copper Share 0 %
Cable weight: 0 kg/km
Copper: 0 kg/km
Approximate values based on technical cable data. Actual values may vary due to manufacturing tolerances.
distributor wire and cable 35kv sourcing
Unima d.d.

Why Unima Cable?

B2B partner for cable distribution across Europe and global industrial projects

Years of Experience
0 +
Fast Delivery
0 +h
Technical Documentation Files
0 +
Markets Served
0 +