Tehnički podaci

  • U-1000 R2V
  • Tip kabela
  • Low Voltage Power Distribution
  • Područje primjene
  • NF C 32-321 / IEC 60502-1
  • Standard

Detaljnije

  • Izolacijski materijal XLPE
  • Pakiranje Wooden Drums / On Request
  • Dostupnost Stock
  • Test Voltage 4 kV
  • Maximum Operating Temperature +90°C
  • Maximum Short-Circuit Temperature +250°C
  • Outer Sheath PVC, Black
  • Core Identification HD 308 S2
  • Materijal vodiča Copper, Class 1 or Class 2
  • Grupa kabela Energetski kablovi 1 - 30 kV
  • Izolacijski materijal XLPE
  • Radni napon 0.6/1 kV
  • CPR razred Eca
  • Standard NF C 32-321 / IEC 60502-1
UNIMA CABLE | POWER CABLES

U-1000 R2V

Low Voltage Power Cable | XLPE Insulation | PVC Outer Sheath | 0.6/1 kV

U-1000 R2V is a low-voltage power cable designed for electrical energy distribution in industrial facilities, buildings, urban networks and fixed installations. Its copper conductors, XLPE insulation and PVC outer sheath provide reliable operation at conductor temperatures up to 90°C, with resistance to sunlight and atmospheric conditions.

0.6/1 kV Radni napon
90°C Max. Operating Temperature
250°C Short-Circuit Temperature
Eca CPR Classification

Cable Construction

ConductorCopper, Class 1 or Class 2
Conductor StandardEN 60228
InsulationXLPE Compound
BeddingExtruded elastomeric or plastomeric compound, or plastic tape
Outer SheathPVC Compound
Sheath ColourCrna
Core IdentificationHD 308 S2

Technical Characteristics

Radni napon0.6/1 kV
Test Voltage4 kV
Operating TemperatureUp to +90°C
Short-Circuit TemperatureUp to +250°C
Minimum Laying Temperature-5°C
Bending Radius – Multicore12 × D
Bending Radius – Single-Core15 × D
StandardiNF C 32-321 / IEC 60502-1
CPR razredEca

Typical Applications

Low-voltage power distribution
Industrial electrical installations
Commercial and residential buildings
Urban distribution networks
Outdoor fixed installations
Cable trays, walls and raceways
Protected underground installations
Installations requiring resistance to sunlight and weather
Installation Note: Direct underground installation requires suitable mechanical protection. Prolonged installation in waterlogged ground is not recommended. Cable dimensions, conductor resistance and weights depend on the selected configuration.
UNIMA CABLE | TECHNICAL DIMENSIONS

U-1000 R2V – Available Cable Dimensions

Nominal cross-sections, maximum conductor resistance at 20°C, maximum outer diameter, copper weight and approximate cable weight.

0.6/1 kV Radni napon
Cu / XLPE Conductor / Insulation
77 Cable Configurations
Cable Size
(mm²)
Max. Resistance
at 20°C (Ω/km)
Max. Outer
Diameter (mm)
Copper Weight
(kg/km)
Approx. Cable
Weight (kg/km)
Technical Note: Outer diameters are maximum values. Cable weights are approximate. Electrical characteristics and installation conditions must be verified for the selected cable configuration.

Technical Documentation

Technical Data Sheet

EU declaration of conformity

Core Identification

UNIMA CABLE

U-1000 R2V Cable Calculator

Calculate cable weight, copper content and approximate cable length.

m
Cable Weight 0 kg
Cable Length 0 m
Copper Content 0 kg
Copper Share 0 %
Cable weight: 0 kg/km
Copper: 0 kg/km
Approximate values based on technical cable data. Actual values may vary due to manufacturing tolerances.
distributor wire and cable 35kv sourcing