N2XS(F)2Y
TECHNICAL DATA SHEET
N2XS(F)2Y | Copper XLPE Medium Voltage Cable | 6/10–18/30 kV | Longitudinally Watertight

N2XS(F)2Y is a copper medium voltage power cable with XLPE insulation, a copper wire metallic screen and a black polyethylene outer sheath.
The cable features a Class 2 stranded bare copper conductor, inner and outer semiconducting layers for electrical field control, and longitudinal water blocking.
Designed for fixed installation in the ground, in water, outdoors, indoors and in cable ducts for power stations, industrial applications and distribution networks.
Available voltage classes are 6/10 kV, 12/20 kV and 18/30 kV. The maximum conductor operating temperature is 90°C.
The polyethylene outer sheath is UV-resistant but is not flame-retardant. Applicable standard: VDE 0276-620.
| Conductor | Bare Copper, Class 2 Stranded |
|---|---|
| Conductor Screen | Inner Semiconducting Layer |
| Insulation | XLPE DIX8 |
| Insulation Screen | Outer Semiconducting Layer |
| Electrical Field Control | Triple Extrusion |
| Metallic Screen | Copper Wires with Counter Helix |
| Water Blocking | Longitudinally Watertight Construction |
| Outer Sheath | Polyethylene DMP2 |
| Sheath Colour | Black |
| Cable Designation | N2XS(F)2Y |
|---|---|
| Cable Type | Copper Medium Voltage Power Cable |
| Rated Voltage | 6/10 kV, 12/20 kV, 18/30 kV |
| Maximum System Voltage | 12 / 24 / 36 kV |
| Test Voltage | 21 / 42 / 63 kV |
| Conductor Material | Bare Copper |
| Conductor Construction | Class 2 Stranded |
| Insulation | XLPE DIX8 |
| Conductor Screen | Semiconducting Layer |
| Insulation Screen | Semiconducting Layer |
| Electrical Field Control | Triple Extrusion |
| Metallic Screen | Copper Wires with Counter Helix |
| Longitudinal Water Blocking | Yes |
| Outer Sheath | Polyethylene DMP2 |
| Sheath Colour | Black |
| Maximum Conductor Temperature | 90°C |
| Maximum Outer Cable Temperature, Fixed | +70°C |
| Permitted Outer Cable Temperature, Moved | -20°C to +70°C |
| Minimum Bending Radius | 15 x Outer Diameter |
| Partial Discharge | 2 pC |
| UV Resistance | Yes |
| Outdoor Installation | Yes |
| Flame Retardance | Not Flame-Retardant |
| CPR Classification | Refer to Manufacturer DoP |
| Product Standard | VDE 0276-620 |
- VDE 0276-620 – Medium Voltage Power Cable Standard
- DIN VDE 0482-332-1 – Flame Retardance Reference (Cable Is Not Flame-Retardant)
- Medium Voltage Power Distribution
- Electrical Substations
- Power Stations
- Industrial Power Networks
- Underground Cable Installation
- Outdoor Electrical Infrastructure
- Installation in Water
- Cable Duct Installations
- Installations Requiring Longitudinal Water Blocking