UNIMA CABLE | TECHNICAL DOCUMENTATION
H05VV-F
TECHNICAL DATA SHEET
H05VV-F | Flexible PVC Insulated and Sheathed Cord | 300/500 V | Class 5 Copper

PRODUCT DESCRIPTION
H05VV-F is a flexible PVC insulated and sheathed cord rated 300/500 V, designed for medium mechanical stress in household, kitchen and office environments.
The cable features bare copper Class 5 fine-stranded conductors, PVC YI2 core insulation and a PVC YM2 outer sheath.
Suitable for connecting household electrical appliances, including appliances in damp rooms. Cooking and heating devices may be connected provided the cable does not touch hot parts or receive direct heat radiation.
The maximum conductor temperature is 60°C. The cable is flame-retardant according to IEC 60332-1-2 and is not suitable for permanent outdoor use.
CABLE CONSTRUCTION
| Conductor | Bare Copper, Class 5 Fine Stranded |
|---|---|
| Core Insulation | PVC Compound YI2 |
| Core Identification | Colours According to VDE 0293 / HD 308 |
| Outer Sheath | PVC Compound YM2 |
| Available Sheath Colours | Black, White and Grey Depending on Variant |
| Protective Conductor | G = With Protective Conductor / X = Without Protective Conductor |
TECHNICAL DATA
| Cable Designation | H05VV-F |
|---|---|
| Cable Type | Flexible PVC Insulated Cord |
| Rated Voltage | 300/500 V |
| Test Voltage | 2 kV |
| Conductor Material | Bare Copper |
| Conductor Construction | Class 5 Fine Stranded |
| Core Insulation | PVC YI2 |
| Outer Sheath | PVC YM2 |
| Core Identification | VDE 0293 / HD 308 |
| Maximum Conductor Temperature | 60°C |
| Maximum Outer Cable Temperature, Fixed | +50°C |
| Permitted Outer Cable Temperature, Moved | +5°C to +50°C |
| Minimum Bending Radius, Fixed | 3 x Outer Diameter |
| Minimum Bending Radius, Moving | 5 x Outer Diameter |
| Flame Retardance | IEC 60332-1-2 |
| Permanent Outdoor Installation | Not Suitable |
| Product Standard | DIN EN 50525-2-11 |
STANDARDS
- DIN EN 50525-2-11 – PVC Insulated Flexible Cords
- DIN EN IEC 60228 – Class 5 Copper Conductors
- IEC 60332-1-2 – Flame Propagation Test
- VDE 0293 / HD 308 – Core Identification
APPLICATIONS
- Household Electrical Appliances
- Kitchen Appliances
- Office Electrical Equipment
- Indoor Flexible Power Connections
- Electrical Appliances in Damp Rooms
- Cooking and Heating Devices Without Direct Heat Contact
- Connections Subject to Medium Mechanical Stress