{"id":5762,"date":"2026-11-25T17:49:08","date_gmt":"2026-11-25T17:49:08","guid":{"rendered":"https:\/\/unima-cable.com\/?post_type=property&#038;p=5762"},"modified":"2026-11-25T17:49:09","modified_gmt":"2026-11-25T17:49:09","slug":"j-2ysty","status":"publish","type":"property","link":"https:\/\/unima-cable.com\/hr\/property\/j-2ysty\/","title":{"rendered":"J-2Y(St)Y"},"content":{"rendered":"<div id=\"unima-j2ysty-overview\">\n\n<style>\n#unima-j2ysty-overview{font-family:Arial,Helvetica,sans-serif;color:#071a2d;line-height:1.65;margin:24px 0}\n#unima-j2ysty-overview *{box-sizing:border-box}\n#unima-j2ysty-overview .hero{background:linear-gradient(120deg,#071a2d,#164263);color:#fff;padding:30px;border-radius:13px}\n#unima-j2ysty-overview .eyebrow{color:#8bd5ff;letter-spacing:2px;font-weight:bold;font-size:11px}\n#unima-j2ysty-overview .hero h2{color:#fff;font-size:26px;margin:5px 0 12px}\n#unima-j2ysty-overview .hero p{color:#d9eaf5;margin:0;font-size:14px}\n#unima-j2ysty-overview .tags{display:flex;flex-wrap:wrap;gap:8px;margin-top:18px}\n#unima-j2ysty-overview .tags span{border:1px solid #55758c;background:#173d5c;color:#fff;border-radius:20px;padding:6px 12px;font-size:12px}\n#unima-j2ysty-overview h3{color:#071a2d;font-size:19px;border-left:4px solid #0878c9;padding-left:12px;margin:27px 0 15px}\n#unima-j2ysty-overview .panel{border:1px solid #dce7ef;border-radius:10px;overflow:hidden}\n#unima-j2ysty-overview .copy{padding:20px;color:#354b60;font-size:14px}\n#unima-j2ysty-overview .copy p{margin:0 0 12px}\n#unima-j2ysty-overview .copy p:last-child{margin-bottom:0}\n#unima-j2ysty-overview .stats{display:grid;grid-template-columns:repeat(4,1fr);gap:10px}\n#unima-j2ysty-overview .stat{background:#f2f8fc;border:1px solid #dce7ef;border-radius:9px;padding:17px 8px;text-align:center}\n#unima-j2ysty-overview .stat b{display:block;font-size:21px}\n#unima-j2ysty-overview .stat small{color:#607487;font-size:11px}\n#unima-j2ysty-overview .columns{display:grid;grid-template-columns:1fr 1fr;gap:16px}\n#unima-j2ysty-overview h4{background:#102d48;color:#fff;margin:0;padding:13px;font-size:14px}\n#unima-j2ysty-overview .item{display:grid;grid-template-columns:minmax(0,45fr) minmax(0,55fr);padding:10px 13px;border-bottom:1px solid #e5edf3;font-size:12px;gap:6px}\n#unima-j2ysty-overview .item span{color:#607487}\n#unima-j2ysty-overview .item strong{overflow-wrap:anywhere}\n#unima-j2ysty-overview .apps{display:grid;grid-template-columns:1fr 1fr;gap:10px}\n#unima-j2ysty-overview .app{background:#f2f8fc;border:1px solid #dce7ef;border-radius:8px;padding:12px;font-size:13px}\n#unima-j2ysty-overview .app:before{content:\"\u2713\";color:#0878c9;font-weight:bold;margin-right:8px}\n#unima-j2ysty-overview .notice{background:#f2f8fc;border-left:4px solid #0878c9;padding:16px;margin-top:22px;font-size:12px;color:#43586b}\n@media(max-width:700px){\n#unima-j2ysty-overview .stats{grid-template-columns:repeat(2,1fr)}\n#unima-j2ysty-overview .columns,#unima-j2ysty-overview .apps{grid-template-columns:1fr}\n#unima-j2ysty-overview .hero{padding:22px}\n#unima-j2ysty-overview .hero h2{font-size:22px}\n}\n<\/style>\n\n<div class=\"hero\">\n\n<div class=\"eyebrow\">UNIMA CABLE | DATA &amp; COMMUNICATION CABLES<\/div>\n\n<h2>J-2Y(St)Y St III Bd \u2013 Screened ISDN &amp; Telecommunication Cable<\/h2>\n\n<p>Screened indoor telecommunication and ISDN installation cable with solid bare copper conductors, polyethylene insulation, star-quad stranding, foil screening, drain wire and grey PVC outer sheath. Designed for analogue and digital signal transmission at data rates up to 16 Mbit\/s.<\/p>\n\n<div class=\"tags\">\n\n<span>100 Ohm<\/span>\n<span>Up to 16 Mbit\/s<\/span>\n<span>2\u2013100 Pairs<\/span>\n<span>0.6 mm Conductor Diameter<\/span>\n<span>Class 1 Solid Copper<\/span>\n<span>PE Insulation<\/span>\n<span>Foil Screen<\/span>\n<span>Drain Wire<\/span>\n<span>Star-Quad Stranding<\/span>\n<span>PVC Outer Sheath<\/span>\n<span>RAL 7032<\/span>\n<span>IEC 60332-1-2<\/span>\n<span>300 V Peak Operating Voltage<\/span>\n\n<\/div>\n\n<\/div>\n\n<h3>Product Overview<\/h3>\n\n<div class=\"panel copy\">\n\n<p><strong>J-2Y(St)Y St III Bd<\/strong> is a screened telecommunication and ISDN installation cable designed for connecting computer units, ISDN sub-units, communication devices and data transmission equipment.<\/p>\n\n<p>The cable incorporates solid bare copper conductors with a nominal conductor diameter of 0.6 mm and polyethylene core insulation.<\/p>\n\n<p>Four insulated conductors are twisted together to form a star-quad. Five star-quads form one sub-unit, with sub-units arranged in layers according to the cable configuration.<\/p>\n\n<p>The cable construction includes foil screening and a drain wire. The outer sheath is manufactured from grey PVC, colour RAL 7032.<\/p>\n\n<p>The specified characteristic impedance is 100 Ohm, with a maximum operating capacitance of 52 nF\/km and a maximum peak operating voltage of 300 V.<\/p>\n\n<p>J-2Y(St)Y St III Bd is intended for installation in dry and wet rooms, on and under plaster, and supports analogue and digital signal transmission at data rates up to 16 Mbit\/s.<\/p>\n\n<p>The reference range comprises 10 configurations from 2 to 100 pairs.<\/p>\n\n<\/div>\n\n<h3>Key Technical Features<\/h3>\n\n<div class=\"stats\">\n\n<div class=\"stat\"><b>100 \u03a9<\/b><small>Characteristic Impedance<\/small><\/div>\n\n<div class=\"stat\"><b>16 Mbit\/s<\/b><small>Maximum Specified Data Rate<\/small><\/div>\n\n<div class=\"stat\"><b>2\u2013100<\/b><small>Number of Pairs<\/small><\/div>\n\n<div class=\"stat\"><b>0.6 mm<\/b><small>Conductor Diameter<\/small><\/div>\n\n<div class=\"stat\"><b>52 nF\/km<\/b><small>Maximum Operating Capacitance<\/small><\/div>\n\n<div class=\"stat\"><b>300 V<\/b><small>Peak Operating Voltage<\/small><\/div>\n\n<div class=\"stat\"><b>5,000<\/b><small>Insulation Resistance M\u03a9\u00b7km<\/small><\/div>\n\n<div class=\"stat\"><b>10<\/b><small>Reference Configurations<\/small><\/div>\n\n<\/div>\n\n<h3>Cable Construction &amp; Technical Properties<\/h3>\n\n<div class=\"columns\">\n\n<div class=\"panel\">\n\n<h4>Cable Construction<\/h4>\n\n<div class=\"item\"><span>Materijal vodi\u010da<\/span><strong>Bare Copper<\/strong><\/div>\n\n<div class=\"item\"><span>Conductor Construction<\/span><strong>Class 1, Solid<\/strong><\/div>\n\n<div class=\"item\"><span>Nominal Conductor Diameter<\/span><strong>0.6 mm<\/strong><\/div>\n\n<div class=\"item\"><span>Number of Pairs<\/span><strong>2\u2013100<\/strong><\/div>\n\n<div class=\"item\"><span>Core Insulation<\/span><strong>Polyethylene (PE)<\/strong><\/div>\n\n<div class=\"item\"><span>Stranding Unit<\/span><strong>Four-Core Star-Quad<\/strong><\/div>\n\n<div class=\"item\"><span>Sub-Unit Construction<\/span><strong>Five Star-Quads<\/strong><\/div>\n\n<div class=\"item\"><span>Overall Stranding<\/span><strong>Bundled Sub-Units in Layers<\/strong><\/div>\n\n<div class=\"item\"><span>Screening<\/span><strong>Foil Screen<\/strong><\/div>\n\n<div class=\"item\"><span>Drain Wire<\/span><strong>Yes<\/strong><\/div>\n\n<div class=\"item\"><span>Outer Sheath Material<\/span><strong>PVC<\/strong><\/div>\n\n<div class=\"item\"><span>Outer Sheath Colour<\/span><strong>Grey, RAL 7032<\/strong><\/div>\n\n<\/div>\n\n<div class=\"panel\">\n\n<h4>Electrical &amp; Mechanical Properties<\/h4>\n\n<div class=\"item\"><span>Characteristic Impedance<\/span><strong>100 Ohm<\/strong><\/div>\n\n<div class=\"item\"><span>Maximum Operating Capacitance<\/span><strong>52 nF\/km<\/strong><\/div>\n\n<div class=\"item\"><span>Peak Operating Voltage<\/span><strong>300 V<\/strong><\/div>\n\n<div class=\"item\"><span>Maximum Data Rate<\/span><strong>16 Mbit\/s<\/strong><\/div>\n\n<div class=\"item\"><span>Insulation Resistance<\/span><strong>5,000 M\u03a9\u00b7km<\/strong><\/div>\n\n<div class=\"item\"><span>Coupling K1<\/span><strong>400 pF<\/strong><\/div>\n\n<div class=\"item\"><span>Coupling K9\u201312<\/span><strong>100 pF<\/strong><\/div>\n\n<div class=\"item\"><span>Fixed Temperature Range<\/span><strong>-30\u00b0C to +70\u00b0C<\/strong><\/div>\n\n<div class=\"item\"><span>Temperature During Movement<\/span><strong>-5\u00b0C to +50\u00b0C<\/strong><\/div>\n\n<div class=\"item\"><span>Minimum Fixed Bending Radius<\/span><strong>7.5 \u00d7 Outer Diameter<\/strong><\/div>\n\n<div class=\"item\"><span>Flame Retardancy<\/span><strong>IEC 60332-1-2<\/strong><\/div>\n\n<div class=\"item\"><span>Approximate Outer Diameter<\/span><strong>5.5\u201325.0 mm<\/strong><\/div>\n\n<div class=\"item\"><span>Copper Weight (GER)<\/span><strong>13\u2013568 kg\/km<\/strong><\/div>\n\n<div class=\"item\"><span>Approximate Cable Weight<\/span><strong>42\u2013861 kg\/km<\/strong><\/div>\n\n<\/div>\n\n<\/div>\n\n<h3>Star-Quad Stranding Technology<\/h3>\n\n<div class=\"columns\">\n\n<div class=\"panel\">\n\n<h4>Four-Core Star-Quad Construction<\/h4>\n\n<div class=\"copy\">\n\n<p>Four individually insulated solid copper conductors are twisted together into a star-quad configuration.<\/p>\n\n<p>Each star-quad comprises four conductors corresponding to two communication pairs.<\/p>\n\n<p>The symmetrical arrangement is intended to support the electrical transmission and coupling characteristics required for telecommunication applications.<\/p>\n\n<\/div>\n\n<\/div>\n\n<div class=\"panel\">\n\n<h4>Bundled Sub-Unit Construction<\/h4>\n\n<div class=\"copy\">\n\n<p>Five star-quads are stranded together to form one sub-unit in the specified bundle construction.<\/p>\n\n<p>Each complete sub-unit therefore contains 20 individual conductors, corresponding to 10 pairs.<\/p>\n\n<p>Sub-units are arranged in layers for larger cable configurations.<\/p>\n\n<p>Smaller configurations contain fewer star-quads.<\/p>\n\n<\/div>\n\n<\/div>\n\n<\/div>\n\n<h3>Core Identification System<\/h3>\n\n<div class=\"panel copy\">\n\n<p>The star-quads within each complete bunch are identified by the following continuous colours:<\/p>\n\n<div class=\"tags\">\n\n<span style=\"background:#b52d38\">Red<\/span>\n<span style=\"background:#287647\">Green<\/span>\n<span style=\"background:#737b84\">Grey<\/span>\n<span style=\"background:#e3c543;color:#071a2d\">Yellow<\/span>\n<span style=\"background:#ffffff;color:#071a2d\">White<\/span>\n\n<\/div>\n\n<p style=\"margin-top:16px\">The four individual conductors within each star-quad are distinguished by ring markings.<\/p>\n\n<\/div>\n\n<div class=\"panel\" style=\"margin-top:15px\">\n\n<h4>Individual Conductor Identification<\/h4>\n\n<div class=\"item\"><span>a-wire 1<\/span><strong>Without Ring<\/strong><\/div>\n\n<div class=\"item\"><span>b-wire 1<\/span><strong>One Ring, Wide Spacing<\/strong><\/div>\n\n<div class=\"item\"><span>a-wire 2<\/span><strong>Double Ring, Wide Spacing<\/strong><\/div>\n\n<div class=\"item\"><span>b-wire 2<\/span><strong>Double Ring, Narrow Spacing<\/strong><\/div>\n\n<\/div>\n\n<h3>Screening &amp; Signal Transmission<\/h3>\n\n<div class=\"columns\">\n\n<div class=\"panel\">\n\n<h4>Foil Screen and Drain Wire<\/h4>\n\n<div class=\"copy\">\n\n<p>The reference cable construction incorporates a foil screen and a drain wire.<\/p>\n\n<p>The screening arrangement is intended to reduce the influence of external electromagnetic interference on transmitted signals.<\/p>\n\n<p>The drain wire facilitates electrical connection of the screening system during termination.<\/p>\n\n<p>Screen material and drain wire dimensions must be confirmed in the final manufacturer specification.<\/p>\n\n<\/div>\n\n<\/div>\n\n<div class=\"panel\">\n\n<h4>100 Ohm Transmission Characteristics<\/h4>\n\n<div class=\"copy\">\n\n<p>The specified characteristic impedance is 100 Ohm.<\/p>\n\n<p>The cable supports analogue and digital signal transmission at data rates up to 16 Mbit\/s according to the reference documentation.<\/p>\n\n<p>Maximum operating capacitance is specified as 52 nF\/km.<\/p>\n\n<p>Transmission distance, attenuation and system compatibility must be assessed according to the connected equipment and installation conditions.<\/p>\n\n<\/div>\n\n<\/div>\n\n<\/div>\n\n<h3>PE Insulation &amp; PVC Outer Sheath<\/h3>\n\n<div class=\"columns\">\n\n<div class=\"panel\">\n\n<h4>Polyethylene Core Insulation<\/h4>\n\n<div class=\"copy\">\n\n<p>The solid copper conductors are individually insulated with polyethylene.<\/p>\n\n<p>The specified insulation resistance is 5,000 M\u03a9\u00b7km.<\/p>\n\n<p>The dielectric construction supports the documented capacitance and impedance characteristics of the communication cable.<\/p>\n\n<\/div>\n\n<\/div>\n\n<div class=\"panel\">\n\n<h4>Grey PVC Outer Sheath<\/h4>\n\n<div class=\"copy\">\n\n<p>The outer sheath is manufactured from polyvinyl chloride in grey RAL 7032.<\/p>\n\n<p>The reference cable is suitable for installation in dry and wet rooms, on and under plaster.<\/p>\n\n<p>Flame-retardant performance is specified according to VDE 0482-332-1-2 and IEC 60332-1-2.<\/p>\n\n<\/div>\n\n<\/div>\n\n<\/div>\n\n<h3>Typical Applications<\/h3>\n\n<div class=\"apps\">\n\n<div class=\"app\">ISDN Communication Systems<\/div>\n\n<div class=\"app\">ISDN Sub-Unit Connections<\/div>\n\n<div class=\"app\">Telecommunication Devices<\/div>\n\n<div class=\"app\">Computer Unit Connections<\/div>\n\n<div class=\"app\">Analogue Signal Transmission<\/div>\n\n<div class=\"app\">Digital Signal Transmission up to 16 Mbit\/s<\/div>\n\n<div class=\"app\">Indoor Telecommunication Infrastructure<\/div>\n\n<div class=\"app\">Commercial Building Communication Systems<\/div>\n\n<div class=\"app\">Legacy Communication Equipment<\/div>\n\n<div class=\"app\">Indoor Installation On and Under Plaster<\/div>\n\n<\/div>\n\n<h3>Installation Conditions<\/h3>\n\n<div class=\"columns\">\n\n<div class=\"panel\">\n\n<h4>Specified Installation Parameters<\/h4>\n\n<div class=\"item\"><span>Dry Rooms<\/span><strong>Suitable<\/strong><\/div>\n\n<div class=\"item\"><span>Wet Rooms<\/span><strong>Suitable<\/strong><\/div>\n\n<div class=\"item\"><span>Installation on Plaster<\/span><strong>Suitable<\/strong><\/div>\n\n<div class=\"item\"><span>Installation under Plaster<\/span><strong>Suitable<\/strong><\/div>\n\n<div class=\"item\"><span>Fixed Temperature Range<\/span><strong>-30\u00b0C to +70\u00b0C<\/strong><\/div>\n\n<div class=\"item\"><span>Temperature During Movement<\/span><strong>-5\u00b0C to +50\u00b0C<\/strong><\/div>\n\n<div class=\"item\"><span>Minimum Fixed Bending Radius<\/span><strong>7.5 \u00d7 D<\/strong><\/div>\n\n<\/div>\n\n<div class=\"panel\">\n\n<h4>Additional Installation Considerations<\/h4>\n\n<div class=\"item\"><span>Outdoor Installation<\/span><strong>Not Specified<\/strong><\/div>\n\n<div class=\"item\"><span>Direct Burial<\/span><strong>Not Specified<\/strong><\/div>\n\n<div class=\"item\"><span>Permanent Water Immersion<\/span><strong>Not Specified<\/strong><\/div>\n\n<div class=\"item\"><span>UV Resistance<\/span><strong>Not Specified<\/strong><\/div>\n\n<div class=\"item\"><span>Continuous Dynamic Flexing<\/span><strong>Not Specified<\/strong><\/div>\n\n<div class=\"item\"><span>Maximum Installation Tensile Load<\/span><strong>Not Specified<\/strong><\/div>\n\n<div class=\"item\"><span>Ethernet Category Rating<\/span><strong>Not Declared<\/strong><\/div>\n\n<\/div>\n\n<\/div>\n\n<h3>Fire &amp; Environmental Performance<\/h3>\n\n<div class=\"columns\">\n\n<div class=\"panel\">\n\n<h4>Specified Properties<\/h4>\n\n<div class=\"item\"><span>Single-Cable Flame Retardancy<\/span><strong>IEC 60332-1-2<\/strong><\/div>\n\n<div class=\"item\"><span>German Flame Test Reference<\/span><strong>VDE 0482-332-1-2<\/strong><\/div>\n\n<div class=\"item\"><span>Outer Sheath<\/span><strong>PVC<\/strong><\/div>\n\n<div class=\"item\"><span>Indoor Wet Room Installation<\/span><strong>Specified<\/strong><\/div>\n\n<\/div>\n\n<div class=\"panel\">\n\n<h4>Additional Fire Performance Requirements<\/h4>\n\n<div class=\"item\"><span>CPR Classification<\/span><strong>Not Specified<\/strong><\/div>\n\n<div class=\"item\"><span>Halogen-Free Construction<\/span><strong>No \u2013 PVC Sheath<\/strong><\/div>\n\n<div class=\"item\"><span>Low-Smoke Performance<\/span><strong>Not Declared<\/strong><\/div>\n\n<div class=\"item\"><span>Fire-Resistant Circuit Integrity<\/span><strong>Not Declared<\/strong><\/div>\n\n<div class=\"item\"><span>Bunched Cable Flame Retardancy<\/span><strong>Not Declared<\/strong><\/div>\n\n<\/div>\n\n<\/div>\n\n<h3>Applicable Standards<\/h3>\n\n<div class=\"panel copy\">\n\n<p><strong>VDE 0482-332-1-2<\/strong> \u2013 German reference for the vertical flame propagation test on a single insulated wire or cable.<\/p>\n\n<p><strong>IEC 60332-1-2<\/strong> \u2013 Vertical flame propagation test for a single insulated wire or cable.<\/p>\n\n<p>The reference datasheet identifies the conductor construction as Class 1 solid copper. A separate conductor or product design standard is not explicitly stated.<\/p>\n\n<\/div>\n\n<div class=\"notice\">\n\n<strong>Data Transmission Note:<\/strong> J-2Y(St)Y St III Bd is a dedicated ISDN and telecommunication cable. Its 100 Ohm impedance does not constitute a declaration of Cat.5e, Cat.6, Cat.6A or other Ethernet category compliance.\n\n<\/div>\n\n<div class=\"notice\">\n\n<strong>Voltage Note:<\/strong> The specified 300 V value refers to peak operating voltage. It is not a declared power cable voltage rating U0\/U.\n\n<\/div>\n\n<div class=\"notice\">\n\n<strong>Technical Note:<\/strong> Technical characteristics are based on the reference J-2Y(St)Y St III Bd datasheet. Final construction, electrical characteristics, conformity documentation and availability must be confirmed during quotation.\n\n<\/div>\n\n<\/div>","protected":false},"excerpt":{"rendered":"<p>UNIMA CABLE | DATA &amp; COMMUNICATION CABLES J-2Y(St)Y St III Bd \u2013 Screened ISDN &amp; Telecommunication Cable Screened indoor telecommunication and ISDN installation cable with solid bare copper conductors, polyethylene insulation, star-quad stranding, foil screening, drain wire and grey PVC outer sheath. Designed for analogue and digital signal transmission at data rates up to 16 [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"template":"","property_type":[199],"property_status":[],"property_feature":[],"property_label":[66,196,81],"property_country":[],"property_state":[],"property_city":[],"property_area":[],"class_list":["post-5762","property","type-property","status-publish","hentry","property_type-data-communication-cables","property_label-commercial-building","property_label-data-center","property_label-industrial-facilities"],"acf":[],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 4.9.9 - aioseo.com -->\n\t<meta name=\"description\" content=\"J-2Y(St)Y St III Bd screened ISDN cable, 100 Ohm, solid copper 0.6 mm, PE insulation, PVC sheath, 2\u2013100 pairs, data transmission up to 16 Mbit\/s.\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<meta name=\"author\" content=\"admin\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/unima-cable.com\/hr\/property\/j-2ysty\/\" \/>\n\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 4.9.9\" \/>\n\t\t<meta property=\"og:locale\" content=\"hr_HR\" \/>\n\t\t<meta property=\"og:site_name\" content=\"Unima cable - Cable distribution\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"J-2Y(St)Y St III Bd ISDN Cable 100 Ohm | UNIMA CABLE\" \/>\n\t\t<meta property=\"og:description\" content=\"J-2Y(St)Y St III Bd screened ISDN cable, 100 Ohm, solid copper 0.6 mm, PE insulation, PVC sheath, 2\u2013100 pairs, data transmission up to 16 Mbit\/s.\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/unima-cable.com\/hr\/property\/j-2ysty\/\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2026-11-25T17:49:08+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2026-11-25T17:49:09+00:00\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:title\" content=\"J-2Y(St)Y St III Bd ISDN Cable 100 Ohm | UNIMA CABLE\" \/>\n\t\t<meta name=\"twitter:description\" content=\"J-2Y(St)Y St III Bd screened ISDN cable, 100 Ohm, solid copper 0.6 mm, PE insulation, PVC sheath, 2\u2013100 pairs, data transmission up to 16 Mbit\/s.\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property\\\/j-2ysty\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr#listItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/unima-cable.com\\\/hr\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property\\\/#listItem\",\"name\":\"Nekretnine\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property\\\/#listItem\",\"position\":2,\"name\":\"Nekretnine\",\"item\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property-type\\\/data-communication-cables\\\/#listItem\",\"name\":\"Data &amp; Communication Cables\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr#listItem\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property-type\\\/data-communication-cables\\\/#listItem\",\"position\":3,\"name\":\"Data &amp; Communication Cables\",\"item\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property-type\\\/data-communication-cables\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property\\\/j-2ysty\\\/#listItem\",\"name\":\"J-2Y(St)Y\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property\\\/#listItem\",\"name\":\"Nekretnine\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property\\\/j-2ysty\\\/#listItem\",\"position\":4,\"name\":\"J-2Y(St)Y\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property-type\\\/data-communication-cables\\\/#listItem\",\"name\":\"Data &amp; Communication Cables\"}}]},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/#organization\",\"name\":\"Unima cable\",\"description\":\"Cable distribution\",\"url\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/author\\\/admin\\\/#author\",\"url\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/author\\\/admin\\\/\",\"name\":\"admin\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property\\\/j-2ysty\\\/#authorImage\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/c5cd64316e8c316b90636704903a98dab06fc1cbc5559bb333833e1a7005aae2?s=96&d=mm&r=g\",\"width\":96,\"height\":96,\"caption\":\"admin\"}},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property\\\/j-2ysty\\\/#webpage\",\"url\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property\\\/j-2ysty\\\/\",\"name\":\"J-2Y(St)Y St III Bd ISDN Cable 100 Ohm | UNIMA CABLE\",\"description\":\"J-2Y(St)Y St III Bd screened ISDN cable, 100 Ohm, solid copper 0.6 mm, PE insulation, PVC sheath, 2\\u2013100 pairs, data transmission up to 16 Mbit\\\/s.\",\"inLanguage\":\"hr\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property\\\/j-2ysty\\\/#breadcrumblist\"},\"author\":{\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/author\\\/admin\\\/#author\"},\"creator\":{\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/author\\\/admin\\\/#author\"},\"datePublished\":\"2026-11-25T17:49:08+00:00\",\"dateModified\":\"2026-11-25T17:49:09+00:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/#website\",\"url\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/\",\"name\":\"Unima cable\",\"description\":\"Cable distribution\",\"inLanguage\":\"hr\",\"publisher\":{\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/#organization\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"J-2Y(St)Y St III Bd ISDN Cable 100 Ohm | UNIMA CABLE","description":"J-2Y(St)Y St III Bd screened ISDN cable, 100 Ohm, solid copper 0.6 mm, PE insulation, PVC sheath, 2\u2013100 pairs, data transmission up to 16 Mbit\/s.","canonical_url":"https:\/\/unima-cable.com\/hr\/property\/j-2ysty\/","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"BreadcrumbList","@id":"https:\/\/unima-cable.com\/hr\/property\/j-2ysty\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/unima-cable.com\/hr#listItem","position":1,"name":"Home","item":"https:\/\/unima-cable.com\/hr","nextItem":{"@type":"ListItem","@id":"https:\/\/unima-cable.com\/hr\/property\/#listItem","name":"Nekretnine"}},{"@type":"ListItem","@id":"https:\/\/unima-cable.com\/hr\/property\/#listItem","position":2,"name":"Nekretnine","item":"https:\/\/unima-cable.com\/hr\/property\/","nextItem":{"@type":"ListItem","@id":"https:\/\/unima-cable.com\/hr\/property-type\/data-communication-cables\/#listItem","name":"Data &amp; Communication Cables"},"previousItem":{"@type":"ListItem","@id":"https:\/\/unima-cable.com\/hr#listItem","name":"Home"}},{"@type":"ListItem","@id":"https:\/\/unima-cable.com\/hr\/property-type\/data-communication-cables\/#listItem","position":3,"name":"Data &amp; Communication Cables","item":"https:\/\/unima-cable.com\/hr\/property-type\/data-communication-cables\/","nextItem":{"@type":"ListItem","@id":"https:\/\/unima-cable.com\/hr\/property\/j-2ysty\/#listItem","name":"J-2Y(St)Y"},"previousItem":{"@type":"ListItem","@id":"https:\/\/unima-cable.com\/hr\/property\/#listItem","name":"Nekretnine"}},{"@type":"ListItem","@id":"https:\/\/unima-cable.com\/hr\/property\/j-2ysty\/#listItem","position":4,"name":"J-2Y(St)Y","previousItem":{"@type":"ListItem","@id":"https:\/\/unima-cable.com\/hr\/property-type\/data-communication-cables\/#listItem","name":"Data &amp; Communication Cables"}}]},{"@type":"Organization","@id":"https:\/\/unima-cable.com\/hr\/#organization","name":"Unima cable","description":"Cable distribution","url":"https:\/\/unima-cable.com\/hr\/"},{"@type":"Person","@id":"https:\/\/unima-cable.com\/hr\/author\/admin\/#author","url":"https:\/\/unima-cable.com\/hr\/author\/admin\/","name":"admin","image":{"@type":"ImageObject","@id":"https:\/\/unima-cable.com\/hr\/property\/j-2ysty\/#authorImage","url":"https:\/\/secure.gravatar.com\/avatar\/c5cd64316e8c316b90636704903a98dab06fc1cbc5559bb333833e1a7005aae2?s=96&d=mm&r=g","width":96,"height":96,"caption":"admin"}},{"@type":"WebPage","@id":"https:\/\/unima-cable.com\/hr\/property\/j-2ysty\/#webpage","url":"https:\/\/unima-cable.com\/hr\/property\/j-2ysty\/","name":"J-2Y(St)Y St III Bd ISDN Cable 100 Ohm | UNIMA CABLE","description":"J-2Y(St)Y St III Bd screened ISDN cable, 100 Ohm, solid copper 0.6 mm, PE insulation, PVC sheath, 2\u2013100 pairs, data transmission up to 16 Mbit\/s.","inLanguage":"hr","isPartOf":{"@id":"https:\/\/unima-cable.com\/hr\/#website"},"breadcrumb":{"@id":"https:\/\/unima-cable.com\/hr\/property\/j-2ysty\/#breadcrumblist"},"author":{"@id":"https:\/\/unima-cable.com\/hr\/author\/admin\/#author"},"creator":{"@id":"https:\/\/unima-cable.com\/hr\/author\/admin\/#author"},"datePublished":"2026-11-25T17:49:08+00:00","dateModified":"2026-11-25T17:49:09+00:00"},{"@type":"WebSite","@id":"https:\/\/unima-cable.com\/hr\/#website","url":"https:\/\/unima-cable.com\/hr\/","name":"Unima cable","description":"Cable distribution","inLanguage":"hr","publisher":{"@id":"https:\/\/unima-cable.com\/hr\/#organization"}}]},"og:locale":"hr_HR","og:site_name":"Unima cable - Cable distribution","og:type":"article","og:title":"J-2Y(St)Y St III Bd ISDN Cable 100 Ohm | UNIMA CABLE","og:description":"J-2Y(St)Y St III Bd screened ISDN cable, 100 Ohm, solid copper 0.6 mm, PE insulation, PVC sheath, 2\u2013100 pairs, data transmission up to 16 Mbit\/s.","og:url":"https:\/\/unima-cable.com\/hr\/property\/j-2ysty\/","article:published_time":"2026-11-25T17:49:08+00:00","article:modified_time":"2026-11-25T17:49:09+00:00","twitter:card":"summary_large_image","twitter:title":"J-2Y(St)Y St III Bd ISDN Cable 100 Ohm | UNIMA CABLE","twitter:description":"J-2Y(St)Y St III Bd screened ISDN cable, 100 Ohm, solid copper 0.6 mm, PE insulation, PVC sheath, 2\u2013100 pairs, data transmission up to 16 Mbit\/s."},"aioseo_meta_data":{"post_id":"5762","title":"J-2Y(St)Y St III Bd ISDN Cable 100 Ohm | UNIMA CABLE","description":"J-2Y(St)Y St III Bd screened ISDN cable, 100 Ohm, solid copper 0.6 mm, PE insulation, PVC sheath, 2\u2013100 pairs, data transmission up to 16 Mbit\/s.","keywords":null,"keyphrases":{"focus":{"keyphrase":"","score":0,"analysis":{"keyphraseInTitle":{"score":0,"maxScore":9,"error":1}}},"additional":[]},"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_custom_url":null,"og_image_custom_fields":null,"og_image_url":null,"og_image_width":null,"og_image_height":null,"og_video":"","og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_image_url":null,"twitter_title":null,"twitter_description":null,"schema_type":"default","schema_type_options":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"WebPage","isEnabled":true},"graphs":[]},"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":"-1","robots_max_videopreview":"-1","robots_max_imagepreview":"large","priority":null,"frequency":"default","local_seo":null,"limit_modified_date":false,"ai":{"faqs":[],"keyPoints":[],"schemas":[],"titles":[],"descriptions":[],"socialPosts":{"email":{"subject":"","preview":"","content":""},"linkedin":[],"twitter":[],"facebook":[],"instagram":[]}},"breadcrumb_settings":null,"seo_analyzer_scan_date":null,"created":"2026-11-25 17:49:09","updated":"2026-11-25 17:50:40"},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/unima-cable.com\/hr\" title=\"Home\">Home<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/unima-cable.com\/hr\/property\/\" title=\"Nekretnine\">Nekretnine<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/unima-cable.com\/hr\/property-type\/data-communication-cables\/\" title=\"Data &amp; Communication Cables\">Data &amp; Communication Cables<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\tJ-2Y(St)Y\n\t\t<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"Home","link":"https:\/\/unima-cable.com\/hr"},{"label":"Nekretnine","link":"https:\/\/unima-cable.com\/hr\/property\/"},{"label":"Data &amp; Communication Cables","link":"https:\/\/unima-cable.com\/hr\/property-type\/data-communication-cables\/"},{"label":"J-2Y(St)Y","link":"https:\/\/unima-cable.com\/hr\/property\/j-2ysty\/"}],"property_meta":{"_edit_lock":["1795681268:1"],"_edit_last":["1"],"fave_show_price_placeholder":["0"],"fave_availability":["Stock"],"fave_property_map":["1"],"fave_property_location":["25.68654,-80.431345,15"],"houzez_geolocation_lat":["25.68654"],"houzez_geolocation_long":["-80.431345"],"fave_property_map_street_view":["hide"],"fave_featured":["0"],"houzez_featured_listing_date":[""],"fave_loggedintoview":["0"],"fave_agent_display_option":["author_info"],"fave_prop_homeslider":["no"],"fave_single_top_area":["global"],"fave_single_content_area":["global"],"technical_datasheet":[""],"_technical_datasheet":["field_6a8040c7beb2c"],"dop":[""],"_dop":["field_6a8041aba97aa"],"cpr_certificate":[""],"_cpr_certificate":["field_6a8041ebd3dd6"],"installation_guide":[""],"_installation_guide":["field_6a80420faf22d"],"cable_calculator_data":[""],"_cable_calculator_data":["field_6a816609a8215"],"datasheet_product_subtitle":[""],"_datasheet_product_subtitle":["field_6ab7857caa586"],"datasheet_description":[""],"_datasheet_description":["field_6ab785aaaa587"],"datasheet_construction":[""],"_datasheet_construction":["field_6ab7866c910b7"],"datasheet_standards":[""],"_datasheet_standards":["field_6ab7869f81536"],"datasheet_applications":[""],"_datasheet_applications":["field_6ab786d7788a3"],"datasheet_technical_data":[""],"_datasheet_technical_data":["field_6ab7870017566"],"datasheet_size_data":[""],"_datasheet_size_data":["field_6ab787279d659"],"datasheet_highlights":[""],"_datasheet_highlights":["field_6ad9232e89762"],"datasheet_category":[""],"_datasheet_category":["field_6ad929e8ec019"],"datasheet_technical_notes":[""],"_datasheet_technical_notes":["field_6ad92a005051a"],"datasheet_cpr_class":[""],"_datasheet_cpr_class":["field_6ad92a1bdd6aa"],"_aioseo_title":["J-2Y(St)Y St III Bd ISDN Cable 100 Ohm | UNIMA CABLE"],"_aioseo_description":["J-2Y(St)Y St III Bd screened ISDN cable, 100 Ohm, solid copper 0.6 mm, PE insulation, PVC sheath, 2\u2013100 pairs, data transmission up to 16 Mbit\/s."],"_aioseo_og_title":[""],"_aioseo_og_description":[""],"_aioseo_og_article_section":[""],"_aioseo_twitter_title":[""],"_aioseo_twitter_description":[""],"_aioseo_keywords":["a:0:{}"],"_aioseo_og_article_tags":["a:0:{}"],"unima_cable_designation":[""],"unima_cable_aliases":[""],"houzez_manual_expire":["0"],"_houzez_expiration_date_status":["saved"],"houzez_total_property_views":["30"],"houzez_views_by_date":["a:5:{s:10:\"11-25-2026\";i:6;s:10:\"11-26-2026\";i:14;s:10:\"11-27-2026\";i:4;s:10:\"11-28-2026\";i:2;s:10:\"11-29-2026\";i:4;}"],"houzez_recently_viewed":["2026-11-29 15:11:37"],"_elementor_page_assets":["a:0:{}"]},"_links":{"self":[{"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/properties\/5762","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/properties"}],"about":[{"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/types\/property"}],"author":[{"embeddable":true,"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/users\/1"}],"version-history":[{"count":1,"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/properties\/5762\/revisions"}],"predecessor-version":[{"id":5763,"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/properties\/5762\/revisions\/5763"}],"wp:attachment":[{"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/media?parent=5762"}],"wp:term":[{"taxonomy":"property_type","embeddable":true,"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/property_type?post=5762"},{"taxonomy":"property_status","embeddable":true,"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/property_status?post=5762"},{"taxonomy":"property_feature","embeddable":true,"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/property_feature?post=5762"},{"taxonomy":"property_label","embeddable":true,"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/property_label?post=5762"},{"taxonomy":"property_country","embeddable":true,"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/property_country?post=5762"},{"taxonomy":"property_state","embeddable":true,"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/property_state?post=5762"},{"taxonomy":"property_city","embeddable":true,"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/property_city?post=5762"},{"taxonomy":"property_area","embeddable":true,"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/property_area?post=5762"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}