{"id":5738,"date":"2026-11-25T14:31:35","date_gmt":"2026-11-25T14:31:35","guid":{"rendered":"https:\/\/unima-cable.com\/?post_type=property&#038;p=5738"},"modified":"2026-11-25T14:31:36","modified_gmt":"2026-11-25T14:31:36","slug":"n2xs2y","status":"publish","type":"property","link":"https:\/\/unima-cable.com\/hr\/property\/n2xs2y\/","title":{"rendered":"N2XS2Y"},"content":{"rendered":"<div id=\"unima-n2xs2y-overview\">\n<style>\n#unima-n2xs2y-overview{font-family:Arial,Helvetica,sans-serif;color:#071a2d;line-height:1.65;margin:24px 0}\n#unima-n2xs2y-overview *{box-sizing:border-box}\n#unima-n2xs2y-overview .hero{background:linear-gradient(120deg,#071a2d,#164263);color:#fff;padding:30px;border-radius:13px}\n#unima-n2xs2y-overview .eyebrow{color:#8bd5ff;letter-spacing:2px;font-weight:bold;font-size:11px}\n#unima-n2xs2y-overview .hero h2{color:#fff;font-size:26px;margin:5px 0 12px}\n#unima-n2xs2y-overview .hero p{color:#d9eaf5;margin:0;font-size:14px}\n#unima-n2xs2y-overview .tags{display:flex;flex-wrap:wrap;gap:8px;margin-top:18px}\n#unima-n2xs2y-overview .tags span{border:1px solid #55758c;background:#173d5c;color:#fff;border-radius:20px;padding:6px 12px;font-size:12px}\n#unima-n2xs2y-overview h3{color:#071a2d;font-size:19px;border-left:4px solid #0878c9;padding-left:12px;margin:27px 0 15px}\n#unima-n2xs2y-overview .panel{border:1px solid #dce7ef;border-radius:10px;overflow:hidden}\n#unima-n2xs2y-overview .copy{padding:20px;color:#354b60;font-size:14px}\n#unima-n2xs2y-overview .copy p{margin:0 0 12px}\n#unima-n2xs2y-overview .copy p:last-child{margin-bottom:0}\n#unima-n2xs2y-overview .stats{display:grid;grid-template-columns:repeat(4,1fr);gap:10px}\n#unima-n2xs2y-overview .stat{background:#f2f8fc;border:1px solid #dce7ef;border-radius:9px;padding:17px 8px;text-align:center}\n#unima-n2xs2y-overview .stat b{display:block;font-size:21px}\n#unima-n2xs2y-overview .stat small{color:#607487;font-size:11px}\n#unima-n2xs2y-overview .columns{display:grid;grid-template-columns:1fr 1fr;gap:16px}\n#unima-n2xs2y-overview .voltage{display:grid;grid-template-columns:repeat(3,1fr);gap:12px}\n#unima-n2xs2y-overview h4{background:#102d48;color:#fff;margin:0;padding:13px;font-size:14px}\n#unima-n2xs2y-overview .item{display:grid;grid-template-columns:minmax(0,45fr) minmax(0,55fr);padding:10px 13px;border-bottom:1px solid #e5edf3;font-size:12px;gap:6px}\n#unima-n2xs2y-overview .item span{color:#607487}\n#unima-n2xs2y-overview .item strong{overflow-wrap:anywhere}\n#unima-n2xs2y-overview .apps{display:grid;grid-template-columns:1fr 1fr;gap:10px}\n#unima-n2xs2y-overview .app{background:#f2f8fc;border:1px solid #dce7ef;border-radius:8px;padding:12px;font-size:13px}\n#unima-n2xs2y-overview .app:before{content:\"\u2713\";color:#0878c9;font-weight:bold;margin-right:8px}\n#unima-n2xs2y-overview .notice{background:#f2f8fc;border-left:4px solid #0878c9;padding:16px;margin-top:22px;font-size:12px;color:#43586b}\n@media(max-width:700px){\n#unima-n2xs2y-overview .stats{grid-template-columns:repeat(2,1fr)}\n#unima-n2xs2y-overview .columns,#unima-n2xs2y-overview .apps,#unima-n2xs2y-overview .voltage{grid-template-columns:1fr}\n#unima-n2xs2y-overview .hero{padding:22px}\n#unima-n2xs2y-overview .hero h2{font-size:22px}\n}\n<\/style>\n\n<div class=\"hero\">\n\n<div class=\"eyebrow\">UNIMA CABLE | MEDIUM VOLTAGE POWER CABLES<\/div>\n\n<h2>N2XS2Y \u2013 Copper Medium Voltage Power Cable<\/h2>\n\n<p>Single-core medium voltage power cable with stranded copper conductor, XLPE insulation, copper wire screen and black polyethylene outer sheath. Designed for underground power distribution, industrial installations and medium voltage electrical infrastructure.<\/p>\n\n<div class=\"tags\">\n<span>6\/10 kV<\/span>\n<span>12\/20 kV<\/span>\n<span>18\/30 kV<\/span>\n<span>35\u2013500 mm\u00b2<\/span>\n<span>Class 2 Copper<\/span>\n<span>XLPE Insulation<\/span>\n<span>Copper Wire Screen<\/span>\n<span>PE Outer Sheath<\/span>\n<span>Direct Burial<\/span>\n<span>DIN VDE 0276-620<\/span>\n<span>HD 620<\/span>\n<\/div>\n\n<\/div>\n\n<h3>Product Overview<\/h3>\n\n<div class=\"panel copy\">\n\n<p><strong>N2XS2Y<\/strong> is a single-core copper medium voltage power cable designed for electrical energy transmission and distribution in underground, outdoor and indoor installations.<\/p>\n\n<p>The cable incorporates a round stranded bare copper conductor (RM), manufactured according to DIN EN 60228 Class 2.<\/p>\n\n<p>The conductor is surrounded by an inner semiconducting layer, cross-linked polyethylene (XLPE) insulation and an outer semiconducting layer.<\/p>\n\n<p>A metallic screen consisting of copper wires surrounds the insulated cable core. The screen forms part of the electrical protection and earthing arrangement of the medium voltage cable system.<\/p>\n\n<p>The black polyethylene outer sheath provides external protection for the cable during installation and service.<\/p>\n\n<p>N2XS2Y is suitable for direct burial, outdoor installations, indoor installations and installation in cable channels.<\/p>\n\n<p>The reference product range includes rated voltages of 6\/10 kV, 12\/20 kV and 18\/30 kV, with copper conductor cross-sections ranging from 35 to 500 mm\u00b2 depending on the selected voltage rating.<\/p>\n\n<\/div>\n\n<h3>Key Technical Features<\/h3>\n\n<div class=\"stats\">\n\n<div class=\"stat\"><b>6\u201330 kV<\/b><small>Rated Voltage Range U<\/small><\/div>\n\n<div class=\"stat\"><b>35\u2013500 mm\u00b2<\/b><small>Conductor Range<\/small><\/div>\n\n<div class=\"stat\"><b>Class 2<\/b><small>Stranded Copper<\/small><\/div>\n\n<div class=\"stat\"><b>+90\u00b0C<\/b><small>Maximum Specified Temperature<\/small><\/div>\n\n<\/div>\n\n<h3>Voltage Classes<\/h3>\n\n<div class=\"voltage\">\n\n<div class=\"panel\">\n\n<h4>N2XS2Y 6\/10 kV<\/h4>\n\n<div class=\"copy\">\n\n<p><strong>35\u2013500 mm\u00b2<\/strong><\/p>\n\n<p>11 reference configurations.<\/p>\n\n<p>Test voltage: 21 kV for 5 minutes.<\/p>\n\n<\/div>\n\n<\/div>\n\n<div class=\"panel\">\n\n<h4>N2XS2Y 12\/20 kV<\/h4>\n\n<div class=\"copy\">\n\n<p><strong>35\u2013500 mm\u00b2<\/strong><\/p>\n\n<p>11 reference configurations.<\/p>\n\n<p>Test voltage: 42 kV for 5 minutes.<\/p>\n\n<\/div>\n\n<\/div>\n\n<div class=\"panel\">\n\n<h4>N2XS2Y 18\/30 kV<\/h4>\n\n<div class=\"copy\">\n\n<p><strong>50\u2013500 mm\u00b2<\/strong><\/p>\n\n<p>10 reference configurations.<\/p>\n\n<p>Test voltage: 63 kV for 5 minutes.<\/p>\n\n<\/div>\n\n<\/div>\n\n<\/div>\n\n<h3>Construction &amp; Technical Properties<\/h3>\n\n<div class=\"columns\">\n\n<div class=\"panel\">\n\n<h4>Cable Construction<\/h4>\n\n<div class=\"item\"><span>Materijal vodi\u010da<\/span><strong>Bare Copper<\/strong><\/div>\n\n<div class=\"item\"><span>Conductor Construction<\/span><strong>Round Stranded (RM)<\/strong><\/div>\n\n<div class=\"item\"><span>Conductor Class<\/span><strong>Class 2<\/strong><\/div>\n\n<div class=\"item\"><span>Conductor Standard<\/span><strong>DIN EN 60228<\/strong><\/div>\n\n<div class=\"item\"><span>Number of Cores<\/span><strong>1<\/strong><\/div>\n\n<div class=\"item\"><span>Conductor Cross-Section<\/span><strong>35\u2013500 mm\u00b2<\/strong><\/div>\n\n<div class=\"item\"><span>Conductor Screen<\/span><strong>Inner Semiconducting Layer<\/strong><\/div>\n\n<div class=\"item\"><span>Core Insulation<\/span><strong>Cross-Linked Polyethylene (XLPE)<\/strong><\/div>\n\n<div class=\"item\"><span>Insulation Screen<\/span><strong>Outer Semiconducting Layer<\/strong><\/div>\n\n<div class=\"item\"><span>Metallic Screen<\/span><strong>Copper Wires<\/strong><\/div>\n\n<div class=\"item\"><span>Screen Cross-Section<\/span><strong>16 \/ 25 \/ 35 mm\u00b2<\/strong><\/div>\n\n<div class=\"item\"><span>Armour<\/span><strong>None<\/strong><\/div>\n\n<div class=\"item\"><span>Outer Sheath<\/span><strong>Polyethylene (PE)<\/strong><\/div>\n\n<div class=\"item\"><span>Sheath Colour<\/span><strong>Crna<\/strong><\/div>\n\n<div class=\"item\"><span>Water-Blocking Layers<\/span><strong>Not Specified<\/strong><\/div>\n\n<\/div>\n\n<div class=\"panel\">\n\n<h4>Electrical &amp; Mechanical Data<\/h4>\n\n<div class=\"item\"><span>Rated Voltage U0\/U<\/span><strong>6\/10, 12\/20, 18\/30 kV<\/strong><\/div>\n\n<div class=\"item\"><span>Test Voltage 6\/10 kV<\/span><strong>21 kV \/ 5 min<\/strong><\/div>\n\n<div class=\"item\"><span>Test Voltage 12\/20 kV<\/span><strong>42 kV \/ 5 min<\/strong><\/div>\n\n<div class=\"item\"><span>Test Voltage 18\/30 kV<\/span><strong>63 kV \/ 5 min<\/strong><\/div>\n\n<div class=\"item\"><span>Temperature During Bending<\/span><strong>-20\u00b0C to +90\u00b0C<\/strong><\/div>\n\n<div class=\"item\"><span>Fixed Installation Temperature<\/span><strong>-20\u00b0C to +90\u00b0C<\/strong><\/div>\n\n<div class=\"item\"><span>Short-Circuit Temperature<\/span><strong>+250\u00b0C<\/strong><\/div>\n\n<div class=\"item\"><span>Maximum Short-Circuit Duration<\/span><strong>5 Seconds<\/strong><\/div>\n\n<div class=\"item\"><span>Minimum Bending Radius<\/span><strong>15 x Cable Diameter<\/strong><\/div>\n\n<div class=\"item\"><span>Approx. Outer Diameter<\/span><strong>23\u201352 mm<\/strong><\/div>\n\n<div class=\"item\"><span>Reference Maximum Diameter<\/span><strong>28\u201357 mm<\/strong><\/div>\n\n<div class=\"item\"><span>Approx. Cable Weight<\/span><strong>820\u20136200 kg\/km<\/strong><\/div>\n\n<div class=\"item\"><span>Current Rating in Ground<\/span><strong>187\u2013765 A<\/strong><\/div>\n\n<div class=\"item\"><span>Current Rating in Air<\/span><strong>197\u2013953 A<\/strong><\/div>\n\n<div class=\"item\"><span>Reference Cable Formation<\/span><strong>Trefoil<\/strong><\/div>\n\n<\/div>\n\n<\/div>\n\n<h3>XLPE Insulation &amp; Copper Wire Screen<\/h3>\n\n<div class=\"columns\">\n\n<div class=\"panel\">\n\n<h4>XLPE Insulation System<\/h4>\n\n<div class=\"copy\">\n\n<p>Cross-linked polyethylene insulation provides the dielectric insulation required for medium voltage power distribution.<\/p>\n\n<p>The inner and outer semiconducting layers support controlled electrical field distribution around the conductor and insulation.<\/p>\n\n<p>The reference documentation specifies a short-circuit temperature of +250\u00b0C for a maximum duration of 5 seconds.<\/p>\n\n<\/div>\n\n<\/div>\n\n<div class=\"panel\">\n\n<h4>Metallic Copper Wire Screen<\/h4>\n\n<div class=\"copy\">\n\n<p>The metallic copper wire screen is available in reference cross-sections of 16, 25 and 35 mm\u00b2.<\/p>\n\n<p>The screen cross-section depends on the selected conductor size and must be suitable for the earthing arrangement and anticipated earth-fault current.<\/p>\n\n<p>Screen bonding and earthing must be designed according to the requirements of the complete medium voltage installation.<\/p>\n\n<\/div>\n\n<\/div>\n\n<\/div>\n\n<h3>PE Outer Sheath &amp; Underground Installation<\/h3>\n\n<div class=\"panel copy\">\n\n<p>The black polyethylene outer sheath provides external protection for underground and outdoor installations.<\/p>\n\n<p>N2XS2Y is suitable for direct burial in the ground, installation in cable channels and installation in indoor and outdoor environments.<\/p>\n\n<p>The reference construction does not specify additional longitudinal or transverse water-blocking layers.<\/p>\n\n<p>Where longitudinal or radial watertightness is required, a separately specified water-blocked cable construction must be selected.<\/p>\n\n<\/div>\n\n<h3>Typical Applications<\/h3>\n\n<div class=\"apps\">\n\n<div class=\"app\">Medium Voltage Distribution Networks<\/div>\n\n<div class=\"app\">Utility Power Infrastructure<\/div>\n\n<div class=\"app\">Underground Power Distribution<\/div>\n\n<div class=\"app\">Industrial Power Distribution<\/div>\n\n<div class=\"app\">Transformer and Substation Connections<\/div>\n\n<div class=\"app\">Medium Voltage Switchgear Connections<\/div>\n\n<div class=\"app\">Solar Farm Medium Voltage Networks<\/div>\n\n<div class=\"app\">Wind Farm Power Collection Networks<\/div>\n\n<div class=\"app\">Battery Energy Storage Systems \u2013 MV Connections<\/div>\n\n<div class=\"app\">Data Center Medium Voltage Infrastructure<\/div>\n\n<div class=\"app\">Commercial Building Power Infrastructure<\/div>\n\n<div class=\"app\">Indoor and Outdoor Cable Channels<\/div>\n\n<\/div>\n\n<h3>Installation Conditions<\/h3>\n\n<div class=\"panel copy\">\n\n<p>N2XS2Y cables are intended for fixed medium voltage installations.<\/p>\n\n<p>The reference documentation permits direct burial, outdoor installation, indoor installation and installation in cable channels.<\/p>\n\n<p>The specified temperature range during bending and for fixed installation is -20\u00b0C to +90\u00b0C.<\/p>\n\n<p>The minimum bending radius is 15 times the cable outer diameter.<\/p>\n\n<p>The published current-carrying capacities are based on trefoil cable formation. Actual current ratings depend on installation conditions, ambient temperature, soil thermal resistivity, burial depth, cable spacing and screen bonding.<\/p>\n\n<p>Installation design must be verified for the actual project conditions.<\/p>\n\n<\/div>\n\n<h3>Applicable Standards<\/h3>\n\n<div class=\"panel copy\">\n\n<p><strong>DIN VDE 0276-620<\/strong> \u2013 Reference standard for medium voltage power cables with extruded insulation.<\/p>\n\n<p><strong>HD 620 S1:1996<\/strong> \u2013 Reference harmonisation document for medium voltage distribution cables, as stated in the original technical documentation.<\/p>\n\n<p><strong>DIN EN 60228, Class 2<\/strong> \u2013 Stranded copper conductor construction.<\/p>\n\n<\/div>\n\n<h3>Related Medium Voltage Cable Constructions<\/h3>\n\n<div class=\"columns\">\n\n<div class=\"panel\">\n\n<h4>Copper Conductor Versions<\/h4>\n\n<div class=\"copy\">\n\n<p><strong>N2XS2Y<\/strong> \u2013 Copper conductor, XLPE insulation, copper wire screen and PE sheath.<\/p>\n\n<p><strong>N2XS(F)2Y<\/strong> \u2013 Related copper conductor construction with longitudinal water blocking.<\/p>\n\n<p><strong>N2XS(FL)2Y<\/strong> \u2013 Related copper conductor construction with longitudinal and transverse water blocking.<\/p>\n\n<\/div>\n\n<\/div>\n\n<div class=\"panel\">\n\n<h4>Aluminium Conductor Versions<\/h4>\n\n<div class=\"copy\">\n\n<p><strong>NA2XS2Y<\/strong> \u2013 Related aluminium conductor construction with XLPE insulation and PE sheath.<\/p>\n\n<p><strong>NA2XS(F)2Y<\/strong> \u2013 Related aluminium conductor construction with longitudinal water blocking.<\/p>\n\n<p><strong>NA2XS(FL)2Y<\/strong> \u2013 Related aluminium conductor construction with longitudinal and transverse water blocking.<\/p>\n\n<\/div>\n\n<\/div>\n\n<\/div>\n\n<div class=\"notice\">\n\n<strong>Technical Note:<\/strong>\n\nRelated cable designations are provided for product orientation and are not declarations of technical equivalence or interchangeability. The reference documentation specifies HD 620 S1:1996. Compliance with current standard editions must be confirmed for the supplied cable. CPR classification, flame retardancy, water-blocking performance and detailed current-rating calculation conditions are not specified. Final technical characteristics and conformity documentation must be confirmed for each project.\n\n<\/div>\n\n<\/div>\n\n\n\n<div id=\"unima-n2xs2y-sizes\">\n\n<style>\n#unima-n2xs2y-sizes{font-family:Arial,Helvetica,sans-serif;color:#071a2d;line-height:1.6;margin:24px 0 35px}\n#unima-n2xs2y-sizes *{box-sizing:border-box}\n#unima-n2xs2y-sizes .hero{background:linear-gradient(120deg,#071a2d,#164263);color:#fff;padding:30px;border-radius:13px}\n#unima-n2xs2y-sizes .eyebrow{color:#8bd5ff;letter-spacing:2px;font-weight:bold;font-size:11px}\n#unima-n2xs2y-sizes .hero h2{color:#fff;font-size:26px;margin:6px 0 12px}\n#unima-n2xs2y-sizes .hero p{color:#d9eaf5;margin:0;font-size:14px}\n#unima-n2xs2y-sizes h3{color:#071a2d;font-size:19px;border-left:4px solid #0878c9;padding-left:12px;margin:27px 0 15px}\n#unima-n2xs2y-sizes .table-wrap{overflow-x:auto;border:1px solid #dce7ef;border-radius:10px}\n#unima-n2xs2y-sizes table{width:100%;min-width:500px;border-collapse:collapse;font-size:12px}\n#unima-n2xs2y-sizes .wide table{min-width:900px}\n#unima-n2xs2y-sizes th{background:#102d48;color:#fff;padding:12px 9px;text-align:left;vertical-align:middle}\n#unima-n2xs2y-sizes td{padding:10px 9px;border-bottom:1px solid #e5edf3;vertical-align:middle}\n#unima-n2xs2y-sizes tbody tr:nth-child(even){background:#f2f8fc}\n#unima-n2xs2y-sizes td:first-child{font-weight:bold;color:#0878c9}\n#unima-n2xs2y-sizes .group-row td{background:#dcebf5!important;color:#102d48!important;font-size:13px;font-weight:bold;padding:12px}\n#unima-n2xs2y-sizes .stats{display:grid;grid-template-columns:repeat(4,1fr);gap:10px;margin-top:20px}\n#unima-n2xs2y-sizes .stat{background:#f2f8fc;border:1px solid #dce7ef;border-radius:9px;padding:17px 8px;text-align:center}\n#unima-n2xs2y-sizes .stat b{display:block;font-size:19px}\n#unima-n2xs2y-sizes .stat small{color:#607487;font-size:11px}\n#unima-n2xs2y-sizes .notice{background:#f2f8fc;border-left:4px solid #0878c9;padding:16px;margin-top:22px;font-size:12px;color:#43586b}\n#unima-n2xs2y-sizes .description{font-size:13px;color:#43586b;margin:12px 0}\n@media(max-width:700px){\n#unima-n2xs2y-sizes .hero{padding:22px}\n#unima-n2xs2y-sizes .hero h2{font-size:22px}\n#unima-n2xs2y-sizes .stats{grid-template-columns:repeat(2,1fr)}\n}\n<\/style>\n\n<div class=\"hero\">\n\n<div class=\"eyebrow\">UNIMA CABLE | TECHNICAL DIMENSIONS<\/div>\n\n<h2>N2XS2Y \u2013 Cable Sizes &amp; Technical Data<\/h2>\n\n<p>Complete reference range of single-core copper medium voltage power cables rated 6\/10 kV, 12\/20 kV and 18\/30 kV, including conductor and screen cross-sections, copper content, cable dimensions, approximate weights and current-carrying capacities.<\/p>\n\n<\/div>\n\n<div class=\"stats\">\n\n<div class=\"stat\"><b>32<\/b><small>Reference Configurations<\/small><\/div>\n\n<div class=\"stat\"><b>35\u2013500 mm\u00b2<\/b><small>Conductor Cross-Section<\/small><\/div>\n\n<div class=\"stat\"><b>16\u201335 mm\u00b2<\/b><small>Copper Wire Screen<\/small><\/div>\n\n<div class=\"stat\"><b>3<\/b><small>Voltage Classes<\/small><\/div>\n\n<\/div>\n\n<h3>N2XS2Y 6\/10 kV \u2013 Cable Sizes &amp; Current Ratings<\/h3>\n\n<div class=\"table-wrap wide\">\n\n<table>\n\n<thead>\n\n<tr>\n<th>Cable Size (mm\u00b2)<\/th>\n<th>Copper Content (kg\/km)<\/th>\n<th>Approx. Outer Diameter (mm)<\/th>\n<th>Max. Outer Diameter (mm)<\/th>\n<th>Approx. Weight (kg\/km)<\/th>\n<th>Current in Ground (A)*<\/th>\n<th>Current in Air (A)*<\/th>\n<\/tr>\n\n<\/thead>\n\n<tbody>\n\n<tr><td>1&#215;35 RM\/16<\/td><td>518.4<\/td><td>23<\/td><td>28<\/td><td>820<\/td><td>187<\/td><td>197<\/td><\/tr>\n\n<tr><td>1&#215;50 RM\/16<\/td><td>662.4<\/td><td>24<\/td><td>29<\/td><td>960<\/td><td>220<\/td><td>236<\/td><\/tr>\n\n<tr><td>1&#215;70 RM\/16<\/td><td>854.4<\/td><td>26<\/td><td>31<\/td><td>1150<\/td><td>269<\/td><td>292<\/td><\/tr>\n\n<tr><td>1&#215;95 RM\/16<\/td><td>1094.4<\/td><td>27<\/td><td>32<\/td><td>1450<\/td><td>320<\/td><td>358<\/td><\/tr>\n\n<tr><td>1&#215;120 RM\/16<\/td><td>1334.4<\/td><td>29<\/td><td>34<\/td><td>1700<\/td><td>363<\/td><td>413<\/td><\/tr>\n\n<tr><td>1&#215;150 RM\/25<\/td><td>1723.2<\/td><td>30<\/td><td>35<\/td><td>2000<\/td><td>405<\/td><td>468<\/td><\/tr>\n\n<tr><td>1&#215;185 RM\/25<\/td><td>2059.2<\/td><td>32<\/td><td>37<\/td><td>2350<\/td><td>456<\/td><td>535<\/td><\/tr>\n\n<tr><td>1&#215;240 RM\/25<\/td><td>2587.2<\/td><td>34<\/td><td>39<\/td><td>2900<\/td><td>526<\/td><td>631<\/td><\/tr>\n\n<tr><td>1&#215;300 RM\/25<\/td><td>3163.2<\/td><td>36<\/td><td>41<\/td><td>3550<\/td><td>591<\/td><td>722<\/td><\/tr>\n\n<tr><td>1&#215;400 RM\/35<\/td><td>4233.6<\/td><td>40<\/td><td>45<\/td><td>4500<\/td><td>662<\/td><td>827<\/td><\/tr>\n\n<tr><td>1&#215;500 RM\/35<\/td><td>5193.6<\/td><td>43<\/td><td>48<\/td><td>5550<\/td><td>744<\/td><td>949<\/td><\/tr>\n\n<\/tbody>\n\n<\/table>\n\n<\/div>\n\n<h3>N2XS2Y 12\/20 kV \u2013 Cable Sizes &amp; Current Ratings<\/h3>\n\n<div class=\"table-wrap wide\">\n\n<table>\n\n<thead>\n\n<tr>\n<th>Cable Size (mm\u00b2)<\/th>\n<th>Copper Content (kg\/km)<\/th>\n<th>Approx. Outer Diameter (mm)<\/th>\n<th>Max. Outer Diameter (mm)<\/th>\n<th>Approx. Weight (kg\/km)<\/th>\n<th>Current in Ground (A)*<\/th>\n<th>Current in Air (A)*<\/th>\n<\/tr>\n\n<\/thead>\n\n<tbody>\n\n<tr><td>1&#215;35 RM\/16<\/td><td>518.4<\/td><td>27<\/td><td>32<\/td><td>1000<\/td><td>189<\/td><td>200<\/td><\/tr>\n\n<tr><td>1&#215;50 RM\/16<\/td><td>662.4<\/td><td>28<\/td><td>33<\/td><td>1150<\/td><td>222<\/td><td>239<\/td><\/tr>\n\n<tr><td>1&#215;70 RM\/16<\/td><td>854.4<\/td><td>30<\/td><td>35<\/td><td>1350<\/td><td>271<\/td><td>297<\/td><\/tr>\n\n<tr><td>1&#215;95 RM\/16<\/td><td>1094.4<\/td><td>31<\/td><td>36<\/td><td>1600<\/td><td>323<\/td><td>361<\/td><\/tr>\n\n<tr><td>1&#215;120 RM\/16<\/td><td>1334.4<\/td><td>33<\/td><td>38<\/td><td>1850<\/td><td>367<\/td><td>416<\/td><\/tr>\n\n<tr><td>1&#215;150 RM\/25<\/td><td>1723.2<\/td><td>34<\/td><td>39<\/td><td>2250<\/td><td>409<\/td><td>470<\/td><\/tr>\n\n<tr><td>1&#215;185 RM\/25<\/td><td>2059.2<\/td><td>36<\/td><td>41<\/td><td>2600<\/td><td>461<\/td><td>538<\/td><\/tr>\n\n<tr><td>1&#215;240 RM\/25<\/td><td>2587.2<\/td><td>39<\/td><td>44<\/td><td>3150<\/td><td>532<\/td><td>634<\/td><\/tr>\n\n<tr><td>1&#215;300 RM\/25<\/td><td>3163.2<\/td><td>41<\/td><td>46<\/td><td>3800<\/td><td>599<\/td><td>724<\/td><\/tr>\n\n<tr><td>1&#215;400 RM\/35<\/td><td>4233.6<\/td><td>44<\/td><td>49<\/td><td>4750<\/td><td>671<\/td><td>829<\/td><\/tr>\n\n<tr><td>1&#215;500 RM\/35<\/td><td>5193.6<\/td><td>47<\/td><td>52<\/td><td>5800<\/td><td>754<\/td><td>953<\/td><\/tr>\n\n<\/tbody>\n\n<\/table>\n\n<\/div>\n\n<h3>N2XS2Y 18\/30 kV \u2013 Cable Sizes &amp; Current Ratings<\/h3>\n\n<div class=\"table-wrap wide\">\n\n<table>\n\n<thead>\n\n<tr>\n<th>Cable Size (mm\u00b2)<\/th>\n<th>Copper Content (kg\/km)<\/th>\n<th>Approx. Outer Diameter (mm)<\/th>\n<th>Max. Outer Diameter (mm)<\/th>\n<th>Approx. Weight (kg\/km)<\/th>\n<th>Current in Ground (A)*<\/th>\n<th>Current in Air (A)*<\/th>\n<\/tr>\n\n<\/thead>\n\n<tbody>\n\n<tr><td>1&#215;50 RM\/16<\/td><td>662.4<\/td><td>33<\/td><td>38<\/td><td>1350<\/td><td>225<\/td><td>241<\/td><\/tr>\n\n<tr><td>1&#215;70 RM\/16<\/td><td>854.4<\/td><td>35<\/td><td>40<\/td><td>1600<\/td><td>274<\/td><td>299<\/td><\/tr>\n\n<tr><td>1&#215;95 RM\/16<\/td><td>1094.4<\/td><td>36<\/td><td>41<\/td><td>1900<\/td><td>327<\/td><td>363<\/td><\/tr>\n\n<tr><td>1&#215;120 RM\/16<\/td><td>1334.4<\/td><td>38<\/td><td>43<\/td><td>2200<\/td><td>371<\/td><td>418<\/td><\/tr>\n\n<tr><td>1&#215;150 RM\/25<\/td><td>1723.2<\/td><td>39<\/td><td>44<\/td><td>2550<\/td><td>414<\/td><td>472<\/td><\/tr>\n\n<tr><td>1&#215;185 RM\/25<\/td><td>2059.2<\/td><td>41<\/td><td>46<\/td><td>2950<\/td><td>466<\/td><td>539<\/td><\/tr>\n\n<tr><td>1&#215;240 RM\/25<\/td><td>2587.2<\/td><td>43<\/td><td>48<\/td><td>3500<\/td><td>539<\/td><td>635<\/td><\/tr>\n\n<tr><td>1&#215;300 RM\/25<\/td><td>3163.2<\/td><td>46<\/td><td>51<\/td><td>4150<\/td><td>606<\/td><td>725<\/td><\/tr>\n\n<tr><td>1&#215;400 RM\/35<\/td><td>4233.6<\/td><td>49<\/td><td>54<\/td><td>5150<\/td><td>680<\/td><td>831<\/td><\/tr>\n\n<tr><td>1&#215;500 RM\/35<\/td><td>5193.6<\/td><td>52<\/td><td>57<\/td><td>6200<\/td><td>765<\/td><td>953<\/td><\/tr>\n\n<\/tbody>\n\n<\/table>\n\n<\/div>\n\n<p class=\"description\">\n\n<strong>* Current-carrying capacities:<\/strong> Reference values for cables installed in trefoil formation. The original documentation does not specify detailed calculation conditions such as ambient temperature, soil thermal resistivity, burial depth or screen bonding arrangement. Actual permissible current must be determined for the project-specific installation.\n\n<\/p>\n\n<p class=\"description\">\n\nCopper content values are reproduced from the reference documentation and must not be interpreted as independently verified recoverable copper mass. Cable dimensions and weights are approximate.\n\n<\/p>\n\n<h3>Voltage Class Comparison<\/h3>\n\n<div class=\"table-wrap wide\">\n\n<table>\n\n<thead>\n\n<tr>\n<th>Parameter<\/th>\n<th>6\/10 kV<\/th>\n<th>12\/20 kV<\/th>\n<th>18\/30 kV<\/th>\n<\/tr>\n\n<\/thead>\n\n<tbody>\n\n<tr><td>Rated Voltage U0\/U<\/td><td>6\/10 kV<\/td><td>12\/20 kV<\/td><td>18\/30 kV<\/td><\/tr>\n\n<tr><td>Conductor Range<\/td><td>35\u2013500 mm\u00b2<\/td><td>35\u2013500 mm\u00b2<\/td><td>50\u2013500 mm\u00b2<\/td><\/tr>\n\n<tr><td>Screen Cross-Section<\/td><td>16\u201335 mm\u00b2<\/td><td>16\u201335 mm\u00b2<\/td><td>16\u201335 mm\u00b2<\/td><\/tr>\n\n<tr><td>Reference Configurations<\/td><td>11<\/td><td>11<\/td><td>10<\/td><\/tr>\n\n<tr><td>Test Voltage<\/td><td>21 kV<\/td><td>42 kV<\/td><td>63 kV<\/td><\/tr>\n\n<tr><td>Test Duration<\/td><td>5 min<\/td><td>5 min<\/td><td>5 min<\/td><\/tr>\n\n<tr><td>Approx. Outer Diameter<\/td><td>23\u201343 mm<\/td><td>27\u201347 mm<\/td><td>33\u201352 mm<\/td><\/tr>\n\n<tr><td>Max. Outer Diameter<\/td><td>28\u201348 mm<\/td><td>32\u201352 mm<\/td><td>38\u201357 mm<\/td><\/tr>\n\n<tr><td>Approx. Cable Weight<\/td><td>820\u20135550 kg\/km<\/td><td>1000\u20135800 kg\/km<\/td><td>1350\u20136200 kg\/km<\/td><\/tr>\n\n<tr><td>Current in Ground*<\/td><td>187\u2013744 A<\/td><td>189\u2013754 A<\/td><td>225\u2013765 A<\/td><\/tr>\n\n<tr><td>Current in Air*<\/td><td>197\u2013949 A<\/td><td>200\u2013953 A<\/td><td>241\u2013953 A<\/td><\/tr>\n\n<\/tbody>\n\n<\/table>\n\n<\/div>\n\n<h3>Conductor &amp; Copper Screen Configuration<\/h3>\n\n<div class=\"table-wrap\">\n\n<table>\n\n<thead>\n\n<tr>\n<th>Conductor Cross-Section (mm\u00b2)<\/th>\n<th>Copper Screen (mm\u00b2)<\/th>\n<th>Conductor Construction<\/th>\n<th>Copper Content (kg\/km)<\/th>\n<\/tr>\n\n<\/thead>\n\n<tbody>\n\n<tr><td>35<\/td><td>16<\/td><td>RM, Class 2<\/td><td>518.4<\/td><\/tr>\n\n<tr><td>50<\/td><td>16<\/td><td>RM, Class 2<\/td><td>662.4<\/td><\/tr>\n\n<tr><td>70<\/td><td>16<\/td><td>RM, Class 2<\/td><td>854.4<\/td><\/tr>\n\n<tr><td>95<\/td><td>16<\/td><td>RM, Class 2<\/td><td>1094.4<\/td><\/tr>\n\n<tr><td>120<\/td><td>16<\/td><td>RM, Class 2<\/td><td>1334.4<\/td><\/tr>\n\n<tr><td>150<\/td><td>25<\/td><td>RM, Class 2<\/td><td>1723.2<\/td><\/tr>\n\n<tr><td>185<\/td><td>25<\/td><td>RM, Class 2<\/td><td>2059.2<\/td><\/tr>\n\n<tr><td>240<\/td><td>25<\/td><td>RM, Class 2<\/td><td>2587.2<\/td><\/tr>\n\n<tr><td>300<\/td><td>25<\/td><td>RM, Class 2<\/td><td>3163.2<\/td><\/tr>\n\n<tr><td>400<\/td><td>35<\/td><td>RM, Class 2<\/td><td>4233.6<\/td><\/tr>\n\n<tr><td>500<\/td><td>35<\/td><td>RM, Class 2<\/td><td>5193.6<\/td><\/tr>\n\n<\/tbody>\n\n<\/table>\n\n<\/div>\n\n<p class=\"description\">\n\nExample: 1&#215;240 RM\/25 identifies a single-core cable with a 240 mm\u00b2 round stranded copper conductor and a 25 mm\u00b2 metallic copper screen.\n\n<\/p>\n\n<h3>Electrical Characteristics<\/h3>\n\n<div class=\"table-wrap\">\n\n<table>\n\n<thead>\n\n<tr><th>Parameter<\/th><th>Reference Value<\/th><\/tr>\n\n<\/thead>\n\n<tbody>\n\n<tr><td>Rated Voltage U0\/U<\/td><td>6\/10, 12\/20 and 18\/30 kV<\/td><\/tr>\n\n<tr><td>Test Voltage 6\/10 kV<\/td><td>21 kV \/ 5 minutes<\/td><\/tr>\n\n<tr><td>Test Voltage 12\/20 kV<\/td><td>42 kV \/ 5 minutes<\/td><\/tr>\n\n<tr><td>Test Voltage 18\/30 kV<\/td><td>63 kV \/ 5 minutes<\/td><\/tr>\n\n<tr><td>Materijal vodi\u010da<\/td><td>Bare Copper<\/td><\/tr>\n\n<tr><td>Conductor Construction<\/td><td>Round Stranded (RM)<\/td><\/tr>\n\n<tr><td>Conductor Class<\/td><td>Class 2<\/td><\/tr>\n\n<tr><td>Conductor Standard<\/td><td>DIN EN 60228<\/td><\/tr>\n\n<tr><td>Izolacijski materijal<\/td><td>XLPE<\/td><\/tr>\n\n<tr><td>Metallic Screen<\/td><td>Copper Wires<\/td><\/tr>\n\n<tr><td>Conductor DC Resistance<\/td><td>Not Specified<\/td><\/tr>\n\n<tr><td>Inductance<\/td><td>Not Specified<\/td><\/tr>\n\n<tr><td>Capacitance<\/td><td>Not Specified<\/td><\/tr>\n\n<tr><td>Screen Short-Circuit Rating<\/td><td>Not Specified<\/td><\/tr>\n\n<tr><td>Reference Current-Rating Formation<\/td><td>Trefoil<\/td><\/tr>\n\n<\/tbody>\n\n<\/table>\n\n<\/div>\n\n<h3>Temperature Characteristics<\/h3>\n\n<div class=\"table-wrap\">\n\n<table>\n\n<thead>\n\n<tr>\n<th>Installation \/ Operating Condition<\/th>\n<th>Minimum Temperature<\/th>\n<th>Maximum Temperature<\/th>\n<\/tr>\n\n<\/thead>\n\n<tbody>\n\n<tr><td>During Bending<\/td><td>-20\u00b0C<\/td><td>+90\u00b0C<\/td><\/tr>\n\n<tr><td>Fixed Installation<\/td><td>-20\u00b0C<\/td><td>+90\u00b0C<\/td><\/tr>\n\n<tr><td>Short-Circuit Condition<\/td><td>Not Specified<\/td><td>+250\u00b0C<\/td><\/tr>\n\n<\/tbody>\n\n<\/table>\n\n<\/div>\n\n<p class=\"description\">\n\nMaximum short-circuit duration: 5 seconds.\n\n<\/p>\n\n<h3>Minimum Cable Bending Radius<\/h3>\n\n<div class=\"table-wrap\">\n\n<table>\n\n<thead>\n\n<tr>\n<th>Cable Size (mm\u00b2)<\/th>\n<th>6\/10 kV (mm)<\/th>\n<th>12\/20 kV (mm)<\/th>\n<th>18\/30 kV (mm)<\/th>\n<\/tr>\n\n<\/thead>\n\n<tbody>\n\n<tr><td>1&#215;35\/16<\/td><td>345<\/td><td>405<\/td><td>\u2014<\/td><\/tr>\n\n<tr><td>1&#215;50\/16<\/td><td>360<\/td><td>420<\/td><td>495<\/td><\/tr>\n\n<tr><td>1&#215;70\/16<\/td><td>390<\/td><td>450<\/td><td>525<\/td><\/tr>\n\n<tr><td>1&#215;95\/16<\/td><td>405<\/td><td>465<\/td><td>540<\/td><\/tr>\n\n<tr><td>1&#215;120\/16<\/td><td>435<\/td><td>495<\/td><td>570<\/td><\/tr>\n\n<tr><td>1&#215;150\/25<\/td><td>450<\/td><td>510<\/td><td>585<\/td><\/tr>\n\n<tr><td>1&#215;185\/25<\/td><td>480<\/td><td>540<\/td><td>615<\/td><\/tr>\n\n<tr><td>1&#215;240\/25<\/td><td>510<\/td><td>585<\/td><td>645<\/td><\/tr>\n\n<tr><td>1&#215;300\/25<\/td><td>540<\/td><td>615<\/td><td>690<\/td><\/tr>\n\n<tr><td>1&#215;400\/35<\/td><td>600<\/td><td>660<\/td><td>735<\/td><\/tr>\n\n<tr><td>1&#215;500\/35<\/td><td>645<\/td><td>705<\/td><td>780<\/td><\/tr>\n\n<\/tbody>\n\n<\/table>\n\n<\/div>\n\n<p class=\"description\">\n\nThe listed bending radii are indicative calculated values based on the approximate outer diameter multiplied by the specified bending factor of 15. For installation planning, the actual supplied cable diameter must be used. Where only the maximum reference diameter is available, a conservative planning radius may be calculated from that value.\n\n<\/p>\n\n<h3>Conservative Bending Radius Based on Maximum Diameter<\/h3>\n\n<div class=\"table-wrap\">\n\n<table>\n\n<thead>\n\n<tr>\n<th>Cable Size (mm\u00b2)<\/th>\n<th>6\/10 kV (mm)<\/th>\n<th>12\/20 kV (mm)<\/th>\n<th>18\/30 kV (mm)<\/th>\n<\/tr>\n\n<\/thead>\n\n<tbody>\n\n<tr><td>1&#215;35\/16<\/td><td>420<\/td><td>480<\/td><td>\u2014<\/td><\/tr>\n\n<tr><td>1&#215;50\/16<\/td><td>435<\/td><td>495<\/td><td>570<\/td><\/tr>\n\n<tr><td>1&#215;70\/16<\/td><td>465<\/td><td>525<\/td><td>600<\/td><\/tr>\n\n<tr><td>1&#215;95\/16<\/td><td>480<\/td><td>540<\/td><td>615<\/td><\/tr>\n\n<tr><td>1&#215;120\/16<\/td><td>510<\/td><td>570<\/td><td>645<\/td><\/tr>\n\n<tr><td>1&#215;150\/25<\/td><td>525<\/td><td>585<\/td><td>660<\/td><\/tr>\n\n<tr><td>1&#215;185\/25<\/td><td>555<\/td><td>615<\/td><td>690<\/td><\/tr>\n\n<tr><td>1&#215;240\/25<\/td><td>585<\/td><td>660<\/td><td>720<\/td><\/tr>\n\n<tr><td>1&#215;300\/25<\/td><td>615<\/td><td>690<\/td><td>765<\/td><\/tr>\n\n<tr><td>1&#215;400\/35<\/td><td>675<\/td><td>735<\/td><td>810<\/td><\/tr>\n\n<tr><td>1&#215;500\/35<\/td><td>720<\/td><td>780<\/td><td>855<\/td><\/tr>\n\n<\/tbody>\n\n<\/table>\n\n<\/div>\n\n<p class=\"description\">\n\nCalculated planning values based on 15 times the maximum reference outer diameter. These values are not separately declared manufacturer installation parameters.\n\n<\/p>\n\n<h3>Cable Construction Layers<\/h3>\n\n<div class=\"table-wrap\">\n\n<table>\n\n<thead>\n\n<tr>\n<th>Layer<\/th>\n<th>Component<\/th>\n<th>Material \/ Construction<\/th>\n<\/tr>\n\n<\/thead>\n\n<tbody>\n\n<tr><td>1<\/td><td>Conductor<\/td><td>Round Stranded Bare Copper, RM, Class 2<\/td><\/tr>\n\n<tr><td>2<\/td><td>Conductor Screen<\/td><td>Inner Semiconducting Layer<\/td><\/tr>\n\n<tr><td>3<\/td><td>Core Insulation<\/td><td>Cross-Linked Polyethylene (XLPE)<\/td><\/tr>\n\n<tr><td>4<\/td><td>Insulation Screen<\/td><td>Outer Semiconducting Layer<\/td><\/tr>\n\n<tr><td>5<\/td><td>Metallic Screen<\/td><td>Copper Wires<\/td><\/tr>\n\n<tr><td>6<\/td><td>Outer Sheath<\/td><td>Black Polyethylene (PE)<\/td><\/tr>\n\n<\/tbody>\n\n<\/table>\n\n<\/div>\n\n<h3>Installation &amp; Environmental Characteristics<\/h3>\n\n<div class=\"table-wrap\">\n\n<table>\n\n<thead>\n\n<tr>\n<th>Parameter<\/th>\n<th>Reference Value<\/th>\n<\/tr>\n\n<\/thead>\n\n<tbody>\n\n<tr><td>Direct Burial<\/td><td>Suitable<\/td><\/tr>\n\n<tr><td>Outdoor Installation<\/td><td>Suitable<\/td><\/tr>\n\n<tr><td>Indoor Installation<\/td><td>Suitable<\/td><\/tr>\n\n<tr><td>Cable Channels<\/td><td>Suitable<\/td><\/tr>\n\n<tr><td>Fixed Installation<\/td><td>Suitable<\/td><\/tr>\n\n<tr><td>Outer Sheath Material<\/td><td>Polyethylene (PE)<\/td><\/tr>\n\n<tr><td>Outer Sheath Colour<\/td><td>Crna<\/td><\/tr>\n\n<tr><td>Minimum Bending Radius<\/td><td>15 x Cable Diameter<\/td><\/tr>\n\n<tr><td>Longitudinal Water Blocking<\/td><td>Not Specified<\/td><\/tr>\n\n<tr><td>Transverse Water Blocking<\/td><td>Not Specified<\/td><\/tr>\n\n<tr><td>Permanent Water Immersion<\/td><td>Not Specified<\/td><\/tr>\n\n<tr><td>UV Resistance Test<\/td><td>Not Specified<\/td><\/tr>\n\n<tr><td>Maximum Pulling Force<\/td><td>Not Specified<\/td><\/tr>\n\n<tr><td>Flame Retardancy<\/td><td>Not Specified<\/td><\/tr>\n\n<tr><td>CPR Classification<\/td><td>Not Specified<\/td><\/tr>\n\n<\/tbody>\n\n<\/table>\n\n<\/div>\n\n<h3>Applicable Standards<\/h3>\n\n<div class=\"table-wrap\">\n\n<table>\n\n<thead>\n\n<tr>\n<th>Standard<\/th>\n<th>Reference Application<\/th>\n<\/tr>\n\n<\/thead>\n\n<tbody>\n\n<tr><td>DIN VDE 0276-620<\/td><td>Medium Voltage Power Cable Construction<\/td><\/tr>\n\n<tr><td>HD 620 S1:1996<\/td><td>Reference Harmonisation Document for Medium Voltage Distribution Cables<\/td><\/tr>\n\n<tr><td>DIN EN 60228<\/td><td>Stranded Copper Conductors, Class 2<\/td><\/tr>\n\n<\/tbody>\n\n<\/table>\n\n<\/div>\n\n<div class=\"notice\">\n\n<strong>Technical Note:<\/strong>\n\nAll cable dimensions, copper content, cable weights and current-carrying capacities are indicative reference values. Published configurations do not constitute a declaration of stock availability. Final dimensions, screen cross-section, electrical characteristics and conformity documentation must be confirmed for the supplied product.\n\n<\/div>\n\n<div class=\"notice\">\n\n<strong>Current-Carrying Capacity:<\/strong>\n\nReference current ratings are reproduced for trefoil cable formation. Detailed environmental and installation assumptions are not provided in the reference documentation. The published values must not be used as final design ratings without project-specific engineering verification.\n\n<\/div>\n\n<div class=\"notice\">\n\n<strong>Data Verification:<\/strong>\n\nAll 32 reference cable configurations are included. Bending radii are calculated from the specified bending factor and the published approximate or maximum outer diameters. HD 620 S1:1996 is retained as stated in the original documentation and does not establish conformity with the latest edition of HD 620. CPR classification, water-blocking performance and additional electrical parameters must be confirmed separately.\n\n<\/div>\n\n<\/div>","protected":false},"excerpt":{"rendered":"<p>UNIMA CABLE | MEDIUM VOLTAGE POWER CABLES N2XS2Y \u2013 Copper Medium Voltage Power Cable Single-core medium voltage power cable with stranded copper conductor, XLPE insulation, copper wire screen and black polyethylene outer sheath. Designed for underground power distribution, industrial installations and medium voltage electrical infrastructure. 6\/10 kV 12\/20 kV 18\/30 kV 35\u2013500 mm\u00b2 Class 2 [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":5739,"parent":0,"menu_order":0,"template":"","property_type":[226,47],"property_status":[],"property_feature":[],"property_label":[75,66,196,81,62,98,74],"property_country":[],"property_state":[],"property_city":[],"property_area":[],"class_list":["post-5738","property","type-property","status-publish","has-post-thumbnail","hentry","property_type-medium-voltage-power-cables","property_type-power-cables","property_label-batery-storage","property_label-commercial-building","property_label-data-center","property_label-industrial-facilities","property_label-solar-energy","property_label-waterfront","property_label-wind-energy"],"acf":[],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 4.9.9 - aioseo.com -->\n\t<meta name=\"description\" content=\"N2XS2Y medium voltage copper cable 6\/10, 12\/20 and 18\/30 kV with XLPE insulation, copper wire screen and PE sheath for underground power networks.\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<meta name=\"author\" content=\"admin\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/unima-cable.com\/hr\/property\/n2xs2y\/\" \/>\n\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 4.9.9\" \/>\n\t\t<meta property=\"og:locale\" content=\"hr_HR\" \/>\n\t\t<meta property=\"og:site_name\" content=\"Unima cable - Cable distribution\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"N2XS2Y Medium Voltage Copper Cable | UNIMA CABLE\" \/>\n\t\t<meta property=\"og:description\" content=\"N2XS2Y medium voltage copper cable 6\/10, 12\/20 and 18\/30 kV with XLPE insulation, copper wire screen and PE sheath for underground power networks.\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/unima-cable.com\/hr\/property\/n2xs2y\/\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2026-11-25T14:31:35+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2026-11-25T14:31:36+00:00\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:title\" content=\"N2XS2Y Medium Voltage Copper Cable | UNIMA CABLE\" \/>\n\t\t<meta name=\"twitter:description\" content=\"N2XS2Y medium voltage copper cable 6\/10, 12\/20 and 18\/30 kV with XLPE insulation, copper wire screen and PE sheath for underground power networks.\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property\\\/n2xs2y\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr#listItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/unima-cable.com\\\/hr\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property\\\/#listItem\",\"name\":\"Nekretnine\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property\\\/#listItem\",\"position\":2,\"name\":\"Nekretnine\",\"item\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property-type\\\/power-cables\\\/#listItem\",\"name\":\"Power Cables\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr#listItem\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property-type\\\/power-cables\\\/#listItem\",\"position\":3,\"name\":\"Power Cables\",\"item\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property-type\\\/power-cables\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property-type\\\/medium-voltage-power-cables\\\/#listItem\",\"name\":\"Medium Voltage Power Cables \\u2013 1\\u201336 kV\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property\\\/#listItem\",\"name\":\"Nekretnine\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property-type\\\/medium-voltage-power-cables\\\/#listItem\",\"position\":4,\"name\":\"Medium Voltage Power Cables \\u2013 1\\u201336 kV\",\"item\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property-type\\\/medium-voltage-power-cables\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property\\\/n2xs2y\\\/#listItem\",\"name\":\"N2XS2Y\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property-type\\\/power-cables\\\/#listItem\",\"name\":\"Power Cables\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property\\\/n2xs2y\\\/#listItem\",\"position\":5,\"name\":\"N2XS2Y\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property-type\\\/medium-voltage-power-cables\\\/#listItem\",\"name\":\"Medium Voltage Power Cables \\u2013 1\\u201336 kV\"}}]},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/#organization\",\"name\":\"Unima cable\",\"description\":\"Cable distribution\",\"url\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/author\\\/admin\\\/#author\",\"url\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/author\\\/admin\\\/\",\"name\":\"admin\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property\\\/n2xs2y\\\/#authorImage\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/c5cd64316e8c316b90636704903a98dab06fc1cbc5559bb333833e1a7005aae2?s=96&d=mm&r=g\",\"width\":96,\"height\":96,\"caption\":\"admin\"}},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property\\\/n2xs2y\\\/#webpage\",\"url\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property\\\/n2xs2y\\\/\",\"name\":\"N2XS2Y Medium Voltage Copper Cable | UNIMA CABLE\",\"description\":\"N2XS2Y medium voltage copper cable 6\\\/10, 12\\\/20 and 18\\\/30 kV with XLPE insulation, copper wire screen and PE sheath for underground power networks.\",\"inLanguage\":\"hr\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property\\\/n2xs2y\\\/#breadcrumblist\"},\"author\":{\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/author\\\/admin\\\/#author\"},\"creator\":{\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/author\\\/admin\\\/#author\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/unima-cable.com\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/Realisticni-presjek-oklopljenog-kabela.png\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property\\\/n2xs2y\\\/#mainImage\",\"width\":1536,\"height\":1024},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property\\\/n2xs2y\\\/#mainImage\"},\"datePublished\":\"2026-11-25T14:31:35+00:00\",\"dateModified\":\"2026-11-25T14:31:36+00:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/#website\",\"url\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/\",\"name\":\"Unima cable\",\"description\":\"Cable distribution\",\"inLanguage\":\"hr\",\"publisher\":{\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/#organization\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"N2XS2Y Medium Voltage Copper Cable | UNIMA CABLE","description":"N2XS2Y medium voltage copper cable 6\/10, 12\/20 and 18\/30 kV with XLPE insulation, copper wire screen and PE sheath for underground power networks.","canonical_url":"https:\/\/unima-cable.com\/hr\/property\/n2xs2y\/","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"BreadcrumbList","@id":"https:\/\/unima-cable.com\/hr\/property\/n2xs2y\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/unima-cable.com\/hr#listItem","position":1,"name":"Home","item":"https:\/\/unima-cable.com\/hr","nextItem":{"@type":"ListItem","@id":"https:\/\/unima-cable.com\/hr\/property\/#listItem","name":"Nekretnine"}},{"@type":"ListItem","@id":"https:\/\/unima-cable.com\/hr\/property\/#listItem","position":2,"name":"Nekretnine","item":"https:\/\/unima-cable.com\/hr\/property\/","nextItem":{"@type":"ListItem","@id":"https:\/\/unima-cable.com\/hr\/property-type\/power-cables\/#listItem","name":"Power Cables"},"previousItem":{"@type":"ListItem","@id":"https:\/\/unima-cable.com\/hr#listItem","name":"Home"}},{"@type":"ListItem","@id":"https:\/\/unima-cable.com\/hr\/property-type\/power-cables\/#listItem","position":3,"name":"Power Cables","item":"https:\/\/unima-cable.com\/hr\/property-type\/power-cables\/","nextItem":{"@type":"ListItem","@id":"https:\/\/unima-cable.com\/hr\/property-type\/medium-voltage-power-cables\/#listItem","name":"Medium Voltage Power Cables \u2013 1\u201336 kV"},"previousItem":{"@type":"ListItem","@id":"https:\/\/unima-cable.com\/hr\/property\/#listItem","name":"Nekretnine"}},{"@type":"ListItem","@id":"https:\/\/unima-cable.com\/hr\/property-type\/medium-voltage-power-cables\/#listItem","position":4,"name":"Medium Voltage Power Cables \u2013 1\u201336 kV","item":"https:\/\/unima-cable.com\/hr\/property-type\/medium-voltage-power-cables\/","nextItem":{"@type":"ListItem","@id":"https:\/\/unima-cable.com\/hr\/property\/n2xs2y\/#listItem","name":"N2XS2Y"},"previousItem":{"@type":"ListItem","@id":"https:\/\/unima-cable.com\/hr\/property-type\/power-cables\/#listItem","name":"Power Cables"}},{"@type":"ListItem","@id":"https:\/\/unima-cable.com\/hr\/property\/n2xs2y\/#listItem","position":5,"name":"N2XS2Y","previousItem":{"@type":"ListItem","@id":"https:\/\/unima-cable.com\/hr\/property-type\/medium-voltage-power-cables\/#listItem","name":"Medium Voltage Power Cables \u2013 1\u201336 kV"}}]},{"@type":"Organization","@id":"https:\/\/unima-cable.com\/hr\/#organization","name":"Unima cable","description":"Cable distribution","url":"https:\/\/unima-cable.com\/hr\/"},{"@type":"Person","@id":"https:\/\/unima-cable.com\/hr\/author\/admin\/#author","url":"https:\/\/unima-cable.com\/hr\/author\/admin\/","name":"admin","image":{"@type":"ImageObject","@id":"https:\/\/unima-cable.com\/hr\/property\/n2xs2y\/#authorImage","url":"https:\/\/secure.gravatar.com\/avatar\/c5cd64316e8c316b90636704903a98dab06fc1cbc5559bb333833e1a7005aae2?s=96&d=mm&r=g","width":96,"height":96,"caption":"admin"}},{"@type":"WebPage","@id":"https:\/\/unima-cable.com\/hr\/property\/n2xs2y\/#webpage","url":"https:\/\/unima-cable.com\/hr\/property\/n2xs2y\/","name":"N2XS2Y Medium Voltage Copper Cable | UNIMA CABLE","description":"N2XS2Y medium voltage copper cable 6\/10, 12\/20 and 18\/30 kV with XLPE insulation, copper wire screen and PE sheath for underground power networks.","inLanguage":"hr","isPartOf":{"@id":"https:\/\/unima-cable.com\/hr\/#website"},"breadcrumb":{"@id":"https:\/\/unima-cable.com\/hr\/property\/n2xs2y\/#breadcrumblist"},"author":{"@id":"https:\/\/unima-cable.com\/hr\/author\/admin\/#author"},"creator":{"@id":"https:\/\/unima-cable.com\/hr\/author\/admin\/#author"},"image":{"@type":"ImageObject","url":"https:\/\/unima-cable.com\/wp-content\/uploads\/2026\/11\/Realisticni-presjek-oklopljenog-kabela.png","@id":"https:\/\/unima-cable.com\/hr\/property\/n2xs2y\/#mainImage","width":1536,"height":1024},"primaryImageOfPage":{"@id":"https:\/\/unima-cable.com\/hr\/property\/n2xs2y\/#mainImage"},"datePublished":"2026-11-25T14:31:35+00:00","dateModified":"2026-11-25T14:31:36+00:00"},{"@type":"WebSite","@id":"https:\/\/unima-cable.com\/hr\/#website","url":"https:\/\/unima-cable.com\/hr\/","name":"Unima cable","description":"Cable distribution","inLanguage":"hr","publisher":{"@id":"https:\/\/unima-cable.com\/hr\/#organization"}}]},"og:locale":"hr_HR","og:site_name":"Unima cable - Cable distribution","og:type":"article","og:title":"N2XS2Y Medium Voltage Copper Cable | UNIMA CABLE","og:description":"N2XS2Y medium voltage copper cable 6\/10, 12\/20 and 18\/30 kV with XLPE insulation, copper wire screen and PE sheath for underground power networks.","og:url":"https:\/\/unima-cable.com\/hr\/property\/n2xs2y\/","article:published_time":"2026-11-25T14:31:35+00:00","article:modified_time":"2026-11-25T14:31:36+00:00","twitter:card":"summary_large_image","twitter:title":"N2XS2Y Medium Voltage Copper Cable | UNIMA CABLE","twitter:description":"N2XS2Y medium voltage copper cable 6\/10, 12\/20 and 18\/30 kV with XLPE insulation, copper wire screen and PE sheath for underground power networks."},"aioseo_meta_data":{"post_id":"5738","title":"N2XS2Y Medium Voltage Copper Cable | UNIMA CABLE","description":"N2XS2Y medium voltage copper cable 6\/10, 12\/20 and 18\/30 kV with XLPE insulation, copper wire screen and PE sheath for underground power networks.","keywords":null,"keyphrases":{"focus":{"keyphrase":"","score":0,"analysis":{"keyphraseInTitle":{"score":0,"maxScore":9,"error":1}}},"additional":[]},"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_custom_url":null,"og_image_custom_fields":null,"og_image_url":null,"og_image_width":null,"og_image_height":null,"og_video":"","og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_image_url":null,"twitter_title":null,"twitter_description":null,"schema_type":"default","schema_type_options":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"WebPage","isEnabled":true},"graphs":[]},"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":"-1","robots_max_videopreview":"-1","robots_max_imagepreview":"large","priority":null,"frequency":"default","local_seo":null,"limit_modified_date":false,"ai":{"faqs":[],"keyPoints":[],"schemas":[],"titles":[],"descriptions":[],"socialPosts":{"email":{"subject":"","preview":"","content":""},"linkedin":[],"twitter":[],"facebook":[],"instagram":[]}},"breadcrumb_settings":null,"seo_analyzer_scan_date":null,"created":"2026-11-25 14:31:36","updated":"2026-11-25 14:41:35"},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/unima-cable.com\/hr\" title=\"Home\">Home<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/unima-cable.com\/hr\/property\/\" title=\"Nekretnine\">Nekretnine<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/unima-cable.com\/hr\/property-type\/power-cables\/\" title=\"Power Cables\">Power Cables<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/unima-cable.com\/hr\/property-type\/medium-voltage-power-cables\/\" title=\"Medium Voltage Power Cables \u2013 1\u201336 kV\">Medium Voltage Power Cables \u2013 1\u201336 kV<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\tN2XS2Y\n\t\t<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"Home","link":"https:\/\/unima-cable.com\/hr"},{"label":"Nekretnine","link":"https:\/\/unima-cable.com\/hr\/property\/"},{"label":"Power Cables","link":"https:\/\/unima-cable.com\/hr\/property-type\/power-cables\/"},{"label":"Medium Voltage Power Cables \u2013 1\u201336 kV","link":"https:\/\/unima-cable.com\/hr\/property-type\/medium-voltage-power-cables\/"},{"label":"N2XS2Y","link":"https:\/\/unima-cable.com\/hr\/property\/n2xs2y\/"}],"property_meta":{"_edit_lock":["1795626168:1"],"_thumbnail_id":["5739"],"_edit_last":["1"],"fave_show_price_placeholder":["0"],"fave_availability":["Stock"],"fave_property_map":["1"],"fave_property_location":["25.68654,-80.431345,15"],"houzez_geolocation_lat":["25.68654"],"houzez_geolocation_long":["-80.431345"],"fave_property_map_street_view":["hide"],"fave_featured":["0"],"houzez_featured_listing_date":[""],"fave_loggedintoview":["0"],"fave_agent_display_option":["author_info"],"fave_prop_homeslider":["no"],"fave_single_top_area":["global"],"fave_single_content_area":["global"],"technical_datasheet":[""],"_technical_datasheet":["field_6a8040c7beb2c"],"dop":[""],"_dop":["field_6a8041aba97aa"],"cpr_certificate":[""],"_cpr_certificate":["field_6a8041ebd3dd6"],"installation_guide":[""],"_installation_guide":["field_6a80420faf22d"],"cable_calculator_data":[""],"_cable_calculator_data":["field_6a816609a8215"],"datasheet_product_subtitle":[""],"_datasheet_product_subtitle":["field_6ab7857caa586"],"datasheet_description":[""],"_datasheet_description":["field_6ab785aaaa587"],"datasheet_construction":[""],"_datasheet_construction":["field_6ab7866c910b7"],"datasheet_standards":[""],"_datasheet_standards":["field_6ab7869f81536"],"datasheet_applications":[""],"_datasheet_applications":["field_6ab786d7788a3"],"datasheet_technical_data":[""],"_datasheet_technical_data":["field_6ab7870017566"],"datasheet_size_data":[""],"_datasheet_size_data":["field_6ab787279d659"],"datasheet_highlights":[""],"_datasheet_highlights":["field_6ad9232e89762"],"datasheet_category":[""],"_datasheet_category":["field_6ad929e8ec019"],"datasheet_technical_notes":[""],"_datasheet_technical_notes":["field_6ad92a005051a"],"datasheet_cpr_class":[""],"_datasheet_cpr_class":["field_6ad92a1bdd6aa"],"_aioseo_title":["N2XS2Y Medium Voltage Copper Cable | UNIMA CABLE"],"_aioseo_description":["N2XS2Y medium voltage copper cable 6\/10, 12\/20 and 18\/30 kV with XLPE insulation, copper wire screen and PE sheath for underground power networks."],"_aioseo_og_title":[""],"_aioseo_og_description":[""],"_aioseo_og_article_section":[""],"_aioseo_twitter_title":[""],"_aioseo_twitter_description":[""],"_aioseo_keywords":["a:0:{}"],"_aioseo_og_article_tags":["a:0:{}"],"unima_cable_designation":[""],"unima_cable_aliases":[""],"houzez_manual_expire":["0"],"_houzez_expiration_date_status":["saved"],"houzez_total_property_views":["36"],"houzez_views_by_date":["a:5:{s:10:\"11-25-2026\";i:9;s:10:\"11-26-2026\";i:13;s:10:\"11-27-2026\";i:6;s:10:\"11-28-2026\";i:2;s:10:\"11-29-2026\";i:6;}"],"houzez_recently_viewed":["2026-11-29 15:11:40"],"_elementor_page_assets":["a:0:{}"]},"_links":{"self":[{"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/properties\/5738","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/properties"}],"about":[{"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/types\/property"}],"author":[{"embeddable":true,"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/users\/1"}],"version-history":[{"count":1,"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/properties\/5738\/revisions"}],"predecessor-version":[{"id":5740,"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/properties\/5738\/revisions\/5740"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/media\/5739"}],"wp:attachment":[{"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/media?parent=5738"}],"wp:term":[{"taxonomy":"property_type","embeddable":true,"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/property_type?post=5738"},{"taxonomy":"property_status","embeddable":true,"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/property_status?post=5738"},{"taxonomy":"property_feature","embeddable":true,"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/property_feature?post=5738"},{"taxonomy":"property_label","embeddable":true,"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/property_label?post=5738"},{"taxonomy":"property_country","embeddable":true,"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/property_country?post=5738"},{"taxonomy":"property_state","embeddable":true,"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/property_state?post=5738"},{"taxonomy":"property_city","embeddable":true,"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/property_city?post=5738"},{"taxonomy":"property_area","embeddable":true,"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/property_area?post=5738"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}