{"id":5726,"date":"2026-11-25T14:05:19","date_gmt":"2026-11-25T14:05:19","guid":{"rendered":"https:\/\/unima-cable.com\/?post_type=property&#038;p=5726"},"modified":"2026-11-25T14:05:19","modified_gmt":"2026-11-25T14:05:19","slug":"a-2yfl2y","status":"publish","type":"property","link":"https:\/\/unima-cable.com\/hr\/property\/a-2yfl2y\/","title":{"rendered":"A-2YF(L)2Y"},"content":{"rendered":"<div id=\"unima-a2yfl2y-overview\">\n<style>\n#unima-a2yfl2y-overview{font-family:Arial,Helvetica,sans-serif;color:#071a2d;line-height:1.65;margin:24px 0}\n#unima-a2yfl2y-overview *{box-sizing:border-box}\n#unima-a2yfl2y-overview .hero{background:linear-gradient(120deg,#071a2d,#164263);color:#fff;padding:30px;border-radius:13px}\n#unima-a2yfl2y-overview .eyebrow{color:#8bd5ff;letter-spacing:2px;font-weight:bold;font-size:11px}\n#unima-a2yfl2y-overview .hero h2{color:#fff;font-size:26px;margin:5px 0 12px}\n#unima-a2yfl2y-overview .hero p{color:#d9eaf5;margin:0;font-size:14px}\n#unima-a2yfl2y-overview .tags{display:flex;flex-wrap:wrap;gap:8px;margin-top:18px}\n#unima-a2yfl2y-overview .tags span{border:1px solid #55758c;background:#173d5c;color:#fff;border-radius:20px;padding:6px 12px;font-size:12px}\n#unima-a2yfl2y-overview h3{color:#071a2d;font-size:19px;border-left:4px solid #0878c9;padding-left:12px;margin:27px 0 15px}\n#unima-a2yfl2y-overview .panel{border:1px solid #dce7ef;border-radius:10px;overflow:hidden}\n#unima-a2yfl2y-overview .copy{padding:20px;color:#354b60;font-size:14px}\n#unima-a2yfl2y-overview .copy p{margin:0 0 12px}\n#unima-a2yfl2y-overview .copy p:last-child{margin-bottom:0}\n#unima-a2yfl2y-overview .stats{display:grid;grid-template-columns:repeat(4,1fr);gap:10px}\n#unima-a2yfl2y-overview .stat{background:#f2f8fc;border:1px solid #dce7ef;border-radius:9px;padding:17px 8px;text-align:center}\n#unima-a2yfl2y-overview .stat b{display:block;font-size:21px}\n#unima-a2yfl2y-overview .stat small{color:#607487;font-size:11px}\n#unima-a2yfl2y-overview .columns{display:grid;grid-template-columns:1fr 1fr;gap:16px}\n#unima-a2yfl2y-overview h4{background:#102d48;color:#fff;margin:0;padding:13px;font-size:14px}\n#unima-a2yfl2y-overview .item{display:grid;grid-template-columns:minmax(0,45fr) minmax(0,55fr);padding:10px 13px;border-bottom:1px solid #e5edf3;font-size:12px;gap:6px}\n#unima-a2yfl2y-overview .item span{color:#607487}\n#unima-a2yfl2y-overview .item strong{overflow-wrap:anywhere}\n#unima-a2yfl2y-overview .apps{display:grid;grid-template-columns:1fr 1fr;gap:10px}\n#unima-a2yfl2y-overview .app{background:#f2f8fc;border:1px solid #dce7ef;border-radius:8px;padding:12px;font-size:13px}\n#unima-a2yfl2y-overview .app:before{content:\"\u2713\";color:#0878c9;font-weight:bold;margin-right:8px}\n#unima-a2yfl2y-overview .notice{background:#f2f8fc;border-left:4px solid #0878c9;padding:16px;margin-top:22px;font-size:12px;color:#43586b}\n@media(max-width:700px){\n#unima-a2yfl2y-overview .stats{grid-template-columns:repeat(2,1fr)}\n#unima-a2yfl2y-overview .columns,#unima-a2yfl2y-overview .apps{grid-template-columns:1fr}\n#unima-a2yfl2y-overview .hero{padding:22px}\n#unima-a2yfl2y-overview .hero h2{font-size:22px}\n}\n<\/style>\n\n<div class=\"hero\">\n\n<div class=\"eyebrow\">UNIMA CABLE | DATA &amp; COMMUNICATION CABLES<\/div>\n\n<h2>A-2YF(L)2Y \u2013 Water-Blocked Telecommunications Cable<\/h2>\n\n<p>PE-insulated copper telecommunications cable with star-quad construction, petrolatum gel filling, laminated aluminium screen and black polyethylene outer sheath. Designed for local communication networks, underground installations and low-frequency industrial communication systems.<\/p>\n\n<div class=\"tags\">\n<span>2\u2013150 Pairs<\/span>\n<span>Solid Copper<\/span>\n<span>0.6 \/ 0.8 mm<\/span>\n<span>PE Insulation<\/span>\n<span>Gel Filled<\/span>\n<span>Star-Quad Construction<\/span>\n<span>Aluminium Screen<\/span>\n<span>PE Sheath<\/span>\n<span>Water Blocking<\/span>\n<span>DIN VDE 0816<\/span>\n<\/div>\n\n<\/div>\n\n<h3>Product Overview<\/h3>\n\n<div class=\"panel copy\">\n\n<p><strong>A-2YF(L)2Y<\/strong> is a screened, polyethylene-insulated telecommunications cable designed for local communication networks and predominantly low-frequency installations.<\/p>\n\n<p>The cable incorporates solid bare copper conductors with nominal diameters of 0.6 mm or 0.8 mm. Individual conductors are insulated with polyethylene and arranged in star quads.<\/p>\n\n<p>The interstices of the cable core are continuously filled with petrolatum gel to provide longitudinal protection against water penetration.<\/p>\n\n<p>A plastic-coated aluminium tape forms the electrostatic screen and contributes to transverse moisture protection. The outer sheath consists of black polyethylene.<\/p>\n\n<p>The longitudinally and transversely water-blocked construction is suitable for underground installations, cable ducts, conduits and communication networks within industrial and operational facilities.<\/p>\n\n<\/div>\n\n<h3>Key Technical Features<\/h3>\n\n<div class=\"stats\">\n\n<div class=\"stat\"><b>2\u2013150<\/b><small>Number of Pairs<\/small><\/div>\n\n<div class=\"stat\"><b>0.6 \/ 0.8 mm<\/b><small>Conductor Diameter<\/small><\/div>\n\n<div class=\"stat\"><b>225 V<\/b><small>Peak Operating Voltage<\/small><\/div>\n\n<div class=\"stat\"><b>+70\u00b0C<\/b><small>Max. Fixed Installation Temperature<\/small><\/div>\n\n<\/div>\n\n<h3>Cable Variants<\/h3>\n\n<div class=\"columns\">\n\n<div class=\"panel\">\n<h4>0.6 mm Copper Conductor<\/h4>\n\n<div class=\"copy\">\n\n<p><strong>2\u2013100 pairs<\/strong><\/p>\n\n<p>Solid bare copper conductors with a nominal diameter of 0.6 mm.<\/p>\n\n<p>Conductor loop resistance: 130.0 \u03a9\/km.<\/p>\n\n<p>Approximate outer diameter: 8.3\u201330.3 mm.<\/p>\n\n<p>Eight reference configurations.<\/p>\n\n<\/div>\n<\/div>\n\n<div class=\"panel\">\n<h4>0.8 mm Copper Conductor<\/h4>\n\n<div class=\"copy\">\n\n<p><strong>2\u2013150 pairs<\/strong><\/p>\n\n<p>Solid bare copper conductors with a nominal diameter of 0.8 mm.<\/p>\n\n<p>Conductor loop resistance: 73.2 \u03a9\/km.<\/p>\n\n<p>Approximate outer diameter: 8.8\u201342.2 mm.<\/p>\n\n<p>Ten reference configurations.<\/p>\n\n<\/div>\n<\/div>\n\n<\/div>\n\n<h3>Construction &amp; Technical Properties<\/h3>\n\n<div class=\"columns\">\n\n<div class=\"panel\">\n\n<h4>Cable Construction<\/h4>\n\n<div class=\"item\"><span>Materijal vodi\u010da<\/span><strong>Bare Copper<\/strong><\/div>\n\n<div class=\"item\"><span>Conductor Construction<\/span><strong>Solid, Class 1<\/strong><\/div>\n\n<div class=\"item\"><span>Conductor Diameter<\/span><strong>0.6 \/ 0.8 mm<\/strong><\/div>\n\n<div class=\"item\"><span>Number of Pairs<\/span><strong>2\u2013150<\/strong><\/div>\n\n<div class=\"item\"><span>Core Insulation<\/span><strong>Polyethylene (PE)<\/strong><\/div>\n\n<div class=\"item\"><span>Core Arrangement<\/span><strong>Star Quads<\/strong><\/div>\n\n<div class=\"item\"><span>Core Filling<\/span><strong>Petrolatum Gel<\/strong><\/div>\n\n<div class=\"item\"><span>Wrapping Layer<\/span><strong>Plastic Foil<\/strong><\/div>\n\n<div class=\"item\"><span>Electrostatic Screen<\/span><strong>Plastic-Coated Aluminium Tape<\/strong><\/div>\n\n<div class=\"item\"><span>Longitudinal Water Blocking<\/span><strong>Yes<\/strong><\/div>\n\n<div class=\"item\"><span>Transverse Water Blocking<\/span><strong>Yes<\/strong><\/div>\n\n<div class=\"item\"><span>Outer Sheath<\/span><strong>Polyethylene (PE)<\/strong><\/div>\n\n<div class=\"item\"><span>Sheath Colour<\/span><strong>Crna<\/strong><\/div>\n\n<\/div>\n\n<div class=\"panel\">\n\n<h4>Electrical &amp; Mechanical Data<\/h4>\n\n<div class=\"item\"><span>Peak Operating Voltage<\/span><strong>225 V<\/strong><\/div>\n\n<div class=\"item\"><span>Test Voltage Core\/Core<\/span><strong>500 V AC, 50 Hz<\/strong><\/div>\n\n<div class=\"item\"><span>Test Voltage Core\/Screen<\/span><strong>2000 V AC, 50 Hz<\/strong><\/div>\n\n<div class=\"item\"><span>Loop Resistance \u00d8 0.6 mm<\/span><strong>130.0 \u03a9\/km<\/strong><\/div>\n\n<div class=\"item\"><span>Loop Resistance \u00d8 0.8 mm<\/span><strong>73.2 \u03a9\/km<\/strong><\/div>\n\n<div class=\"item\"><span>Min. Insulation Resistance<\/span><strong>1500 M\u03a9\/km<\/strong><\/div>\n\n<div class=\"item\"><span>Max. Operating Capacitance<\/span><strong>52 nF\/km<\/strong><\/div>\n\n<div class=\"item\"><span>Max. Capacitance Unbalance<\/span><strong>800 pF \/ 100 m<\/strong><\/div>\n\n<div class=\"item\"><span>Temperature During Bending<\/span><strong>-20\u00b0C to +50\u00b0C<\/strong><\/div>\n\n<div class=\"item\"><span>Fixed Installation Temperature<\/span><strong>-20\u00b0C to +70\u00b0C<\/strong><\/div>\n\n<div class=\"item\"><span>Minimum Bending Radius<\/span><strong>15 x Cable Diameter<\/strong><\/div>\n\n<div class=\"item\"><span>Approx. Outer Diameter<\/span><strong>8.3\u201342.2 mm<\/strong><\/div>\n\n<div class=\"item\"><span>Approx. Cable Weight<\/span><strong>67\u20132553 kg\/km<\/strong><\/div>\n\n<\/div>\n\n<\/div>\n\n<h3>Water-Blocking Construction<\/h3>\n\n<div class=\"columns\">\n\n<div class=\"panel\">\n\n<h4>Longitudinal Water Protection<\/h4>\n\n<div class=\"copy\">\n\n<p>The cable core interstices are continuously filled with petrolatum gel to restrict longitudinal water migration within the cable.<\/p>\n\n<\/div>\n\n<\/div>\n\n<div class=\"panel\">\n\n<h4>Transverse Water Protection<\/h4>\n\n<div class=\"copy\">\n\n<p>The plastic-coated aluminium tape and polyethylene outer sheath provide the transverse moisture-protection construction specified for this cable type.<\/p>\n\n<\/div>\n\n<\/div>\n\n<\/div>\n\n<h3>Typical Applications<\/h3>\n\n<div class=\"apps\">\n\n<div class=\"app\">Local Telecommunications Networks<\/div>\n\n<div class=\"app\">Underground Communication Networks<\/div>\n\n<div class=\"app\">Industrial Communication Infrastructure<\/div>\n\n<div class=\"app\">Low-Frequency Communication Systems<\/div>\n\n<div class=\"app\">Cable Duct Installations<\/div>\n\n<div class=\"app\">Conduit Installations<\/div>\n\n<div class=\"app\">Operational Facility Networks<\/div>\n\n<div class=\"app\">Utility Communication Infrastructure<\/div>\n\n<\/div>\n\n<h3>Installation Methods<\/h3>\n\n<div class=\"panel copy\">\n\n<p>A-2YF(L)2Y telecommunications cables are suitable for installation directly in the ground, in conduits and in cable ducts.<\/p>\n\n<p>The specified minimum bending radius during bending is 15 times the overall cable diameter.<\/p>\n\n<p>The permitted temperature range during bending is -20\u00b0C to +50\u00b0C. For fixed installations, the specified temperature range is -20\u00b0C to +70\u00b0C.<\/p>\n\n<p>Installation conditions and mechanical protection requirements must be assessed for the individual project.<\/p>\n\n<\/div>\n\n<h3>Applicable Standards<\/h3>\n\n<div class=\"panel copy\">\n\n<p><strong>DIN VDE 0816<\/strong> \u2013 Reference standard for core identification.<\/p>\n\n<p><strong>DIN EN 60228, Class 1<\/strong> \u2013 Reference standard for solid conductor construction.<\/p>\n\n<\/div>\n\n<div class=\"notice\">\n\n<strong>Technical Note:<\/strong>\n\nCable dimensions, copper content and weights depend on the selected configuration. The nominal conductor dimensions of 0.6 mm and 0.8 mm refer to conductor diameter, not conductor cross-sectional area. CPR classification, flame retardancy, UV resistance and maximum tensile load are not specified in the reference documentation. All technical characteristics must be confirmed for the supplied product.\n\n<\/div>\n\n<\/div>\n\n\n\n<div id=\"unima-a2yfl2y-sizes\">\n\n<style>\n#unima-a2yfl2y-sizes{font-family:Arial,Helvetica,sans-serif;color:#071a2d;line-height:1.6;margin:24px 0 35px}\n#unima-a2yfl2y-sizes *{box-sizing:border-box}\n#unima-a2yfl2y-sizes .hero{background:linear-gradient(120deg,#071a2d,#164263);color:#fff;padding:30px;border-radius:13px}\n#unima-a2yfl2y-sizes .eyebrow{color:#8bd5ff;letter-spacing:2px;font-weight:bold;font-size:11px}\n#unima-a2yfl2y-sizes .hero h2{color:#fff;font-size:26px;margin:6px 0 12px}\n#unima-a2yfl2y-sizes .hero p{color:#d9eaf5;margin:0;font-size:14px}\n#unima-a2yfl2y-sizes h3{color:#071a2d;font-size:19px;border-left:4px solid #0878c9;padding-left:12px;margin:27px 0 15px}\n#unima-a2yfl2y-sizes .table-wrap{overflow-x:auto;border:1px solid #dce7ef;border-radius:10px}\n#unima-a2yfl2y-sizes table{width:100%;min-width:500px;border-collapse:collapse;font-size:12px}\n#unima-a2yfl2y-sizes .wide table{min-width:850px}\n#unima-a2yfl2y-sizes th{background:#102d48;color:#fff;padding:12px 9px;text-align:left;vertical-align:middle}\n#unima-a2yfl2y-sizes td{padding:10px 9px;border-bottom:1px solid #e5edf3;vertical-align:middle}\n#unima-a2yfl2y-sizes tbody tr:nth-child(even){background:#f2f8fc}\n#unima-a2yfl2y-sizes td:first-child{font-weight:bold;color:#0878c9}\n#unima-a2yfl2y-sizes .group-row td{background:#dcebf5!important;color:#102d48!important;font-size:13px;font-weight:bold;padding:12px}\n#unima-a2yfl2y-sizes .stats{display:grid;grid-template-columns:repeat(4,1fr);gap:10px;margin-top:20px}\n#unima-a2yfl2y-sizes .stat{background:#f2f8fc;border:1px solid #dce7ef;border-radius:9px;padding:17px 8px;text-align:center}\n#unima-a2yfl2y-sizes .stat b{display:block;font-size:19px}\n#unima-a2yfl2y-sizes .stat small{color:#607487;font-size:11px}\n#unima-a2yfl2y-sizes .notice{background:#f2f8fc;border-left:4px solid #0878c9;padding:16px;margin-top:22px;font-size:12px;color:#43586b}\n#unima-a2yfl2y-sizes .description{font-size:13px;color:#43586b;margin:12px 0}\n@media(max-width:700px){\n#unima-a2yfl2y-sizes .hero{padding:22px}\n#unima-a2yfl2y-sizes .hero h2{font-size:22px}\n#unima-a2yfl2y-sizes .stats{grid-template-columns:repeat(2,1fr)}\n}\n<\/style>\n\n<div class=\"hero\">\n\n<div class=\"eyebrow\">UNIMA CABLE | TECHNICAL DIMENSIONS<\/div>\n\n<h2>A-2YF(L)2Y \u2013 Cable Sizes &amp; Technical Data<\/h2>\n\n<p>Complete reference range of water-blocked copper telecommunications cables with 0.6 mm and 0.8 mm solid copper conductors, including cable dimensions, copper content, cable weights, electrical characteristics and installation parameters.<\/p>\n\n<\/div>\n\n<div class=\"stats\">\n\n<div class=\"stat\"><b>18<\/b><small>Reference Configurations<\/small><\/div>\n\n<div class=\"stat\"><b>2\u2013150<\/b><small>Number of Pairs<\/small><\/div>\n\n<div class=\"stat\"><b>8.3\u201342.2 mm<\/b><small>Outer Diameter<\/small><\/div>\n\n<div class=\"stat\"><b>67\u20132553 kg\/km<\/b><small>Cable Weight<\/small><\/div>\n\n<\/div>\n\n<h3>Available Cable Sizes &amp; Construction Data<\/h3>\n\n<div class=\"table-wrap wide\">\n\n<table>\n\n<thead>\n<tr>\n<th>Cable Size<\/th>\n<th>Number of Pairs<\/th>\n<th>Conductor Diameter (mm)<\/th>\n<th>Copper Content (kg\/km)<\/th>\n<th>Insulation Thickness* (mm)<\/th>\n<th>Approx. Outer Diameter (mm)<\/th>\n<th>Approx. Weight (kg\/km)<\/th>\n<\/tr>\n<\/thead>\n\n<tbody>\n\n<tr class=\"group-row\">\n<td colspan=\"7\">A-2YF(L)2Y \u2013 0.6 mm Solid Copper Conductors<\/td>\n<\/tr>\n\n<tr>\n<td>2x2x0.6<\/td><td>2<\/td><td>0.6<\/td><td>12.5<\/td><td>1.8<\/td><td>8.3<\/td><td>67<\/td>\n<\/tr>\n\n<tr>\n<td>6x2x0.6<\/td><td>6<\/td><td>0.6<\/td><td>34.6<\/td><td>1.8<\/td><td>11.0<\/td><td>126<\/td>\n<\/tr>\n\n<tr>\n<td>10x2x0.6<\/td><td>10<\/td><td>0.6<\/td><td>56.6<\/td><td>1.8<\/td><td>12.5<\/td><td>171<\/td>\n<\/tr>\n\n<tr>\n<td>20x2x0.6<\/td><td>20<\/td><td>0.6<\/td><td>110.4<\/td><td>1.8<\/td><td>15.8<\/td><td>287<\/td>\n<\/tr>\n\n<tr>\n<td>30x2x0.6<\/td><td>30<\/td><td>0.6<\/td><td>165.1<\/td><td>1.8<\/td><td>19.0<\/td><td>409<\/td>\n<\/tr>\n\n<tr>\n<td>40x2x0.6<\/td><td>40<\/td><td>0.6<\/td><td>218.9<\/td><td>1.8<\/td><td>20.4<\/td><td>503<\/td>\n<\/tr>\n\n<tr>\n<td>50x2x0.6<\/td><td>50<\/td><td>0.6<\/td><td>273.6<\/td><td>1.8<\/td><td>22.2<\/td><td>606<\/td>\n<\/tr>\n\n<tr>\n<td>100x2x0.6<\/td><td>100<\/td><td>0.6<\/td><td>545.3<\/td><td>2.0<\/td><td>30.3<\/td><td>1155<\/td>\n<\/tr>\n\n<tr class=\"group-row\">\n<td colspan=\"7\">A-2YF(L)2Y \u2013 0.8 mm Solid Copper Conductors<\/td>\n<\/tr>\n\n<tr>\n<td>2x2x0.8<\/td><td>2<\/td><td>0.8<\/td><td>21.1<\/td><td>1.8<\/td><td>8.8<\/td><td>83<\/td>\n<\/tr>\n\n<tr>\n<td>4x2x0.8<\/td><td>4<\/td><td>0.8<\/td><td>39.4<\/td><td>1.8<\/td><td>11.2<\/td><td>134<\/td>\n<\/tr>\n\n<tr>\n<td>6x2x0.8<\/td><td>6<\/td><td>0.8<\/td><td>59.5<\/td><td>1.8<\/td><td>12.0<\/td><td>165<\/td>\n<\/tr>\n\n<tr>\n<td>10x2x0.8<\/td><td>10<\/td><td>0.8<\/td><td>98.9<\/td><td>1.8<\/td><td>14.0<\/td><td>232<\/td>\n<\/tr>\n\n<tr>\n<td>20x2x0.8<\/td><td>20<\/td><td>0.8<\/td><td>194.9<\/td><td>1.8<\/td><td>19.1<\/td><td>445<\/td>\n<\/tr>\n\n<tr>\n<td>30x2x0.8<\/td><td>30<\/td><td>0.8<\/td><td>291.8<\/td><td>1.8<\/td><td>22.0<\/td><td>588<\/td>\n<\/tr>\n\n<tr>\n<td>40x2x0.8<\/td><td>40<\/td><td>0.8<\/td><td>387.8<\/td><td>2.0<\/td><td>24.0<\/td><td>748<\/td>\n<\/tr>\n\n<tr>\n<td>50x2x0.8<\/td><td>50<\/td><td>0.8<\/td><td>484.8<\/td><td>2.0<\/td><td>26.0<\/td><td>910<\/td>\n<\/tr>\n\n<tr>\n<td>100x2x0.8<\/td><td>100<\/td><td>0.8<\/td><td>967.7<\/td><td>2.2<\/td><td>36.0<\/td><td>1787<\/td>\n<\/tr>\n\n<tr>\n<td>150x2x0.8<\/td><td>150<\/td><td>0.8<\/td><td>1451.5<\/td><td>2.2<\/td><td>42.2<\/td><td>2553<\/td>\n<\/tr>\n\n<\/tbody>\n\n<\/table>\n\n<\/div>\n\n<p class=\"description\">\n\nCable sizes are expressed as number of pairs x two conductors x nominal conductor diameter in millimetres. Cable diameters and weights are approximate.\n\n<\/p>\n\n<p class=\"description\">\n\n*The thickness values of 1.8\u20132.2 mm are reproduced under the insulation thickness heading used in the reference documentation. The specific cable layer to which these values apply must be confirmed before technical approval.\n\n<\/p>\n\n<h3>Conductor Characteristics<\/h3>\n\n<div class=\"table-wrap\">\n\n<table>\n\n<thead>\n<tr>\n<th>Parameter<\/th>\n<th>0.6 mm Conductor<\/th>\n<th>0.8 mm Conductor<\/th>\n<\/tr>\n<\/thead>\n\n<tbody>\n\n<tr>\n<td>Materijal vodi\u010da<\/td><td>Bare Copper<\/td><td>Bare Copper<\/td>\n<\/tr>\n\n<tr>\n<td>Conductor Construction<\/td><td>Solid, Class 1<\/td><td>Solid, Class 1<\/td>\n<\/tr>\n\n<tr>\n<td>Nominal Conductor Diameter<\/td><td>0.6 mm<\/td><td>0.8 mm<\/td>\n<\/tr>\n\n<tr>\n<td>Calculated Geometric Cross-Section<\/td><td>0.283 mm\u00b2<\/td><td>0.503 mm\u00b2<\/td>\n<\/tr>\n\n<tr>\n<td>Conductor Loop Resistance<\/td><td>130.0 \u03a9\/km<\/td><td>73.2 \u03a9\/km<\/td>\n<\/tr>\n\n<tr>\n<td>Number of Pairs<\/td><td>2\u2013100<\/td><td>2\u2013150<\/td>\n<\/tr>\n\n<tr>\n<td>Reference Configurations<\/td><td>8<\/td><td>10<\/td>\n<\/tr>\n\n<tr>\n<td>Core Arrangement<\/td><td>Star Quads<\/td><td>Star Quads<\/td>\n<\/tr>\n\n<tr>\n<td>Core Insulation<\/td><td>PE<\/td><td>PE<\/td>\n<\/tr>\n\n<\/tbody>\n\n<\/table>\n\n<\/div>\n\n<p class=\"description\">\n\nGeometric conductor cross-sections are calculated from the nominal conductor diameters using the circular area formula. They are not independently declared nominal cross-sections.\n\n<\/p>\n\n<h3>Electrical Characteristics<\/h3>\n\n<div class=\"table-wrap\">\n\n<table>\n\n<thead>\n<tr>\n<th>Parameter<\/th>\n<th>Reference Value<\/th>\n<\/tr>\n<\/thead>\n\n<tbody>\n\n<tr>\n<td>Peak Operating Voltage<\/td><td>225 V<\/td>\n<\/tr>\n\n<tr>\n<td>Test Voltage Core\/Core at 50 Hz<\/td><td>500 V AC<\/td>\n<\/tr>\n\n<tr>\n<td>Test Voltage Core\/Screen at 50 Hz<\/td><td>2000 V AC<\/td>\n<\/tr>\n\n<tr>\n<td>Loop Resistance \u2013 0.6 mm<\/td><td>130.0 \u03a9\/km<\/td>\n<\/tr>\n\n<tr>\n<td>Loop Resistance \u2013 0.8 mm<\/td><td>73.2 \u03a9\/km<\/td>\n<\/tr>\n\n<tr>\n<td>Minimum Insulation Resistance<\/td><td>1500 M\u03a9\/km<\/td>\n<\/tr>\n\n<tr>\n<td>Maximum Operating Capacitance<\/td><td>52 nF\/km<\/td>\n<\/tr>\n\n<tr>\n<td>Maximum Capacitance Unbalance per 100 m<\/td><td>800 pF<\/td>\n<\/tr>\n\n<\/tbody>\n\n<\/table>\n\n<\/div>\n\n<h3>Temperature &amp; Mechanical Characteristics<\/h3>\n\n<div class=\"table-wrap\">\n\n<table>\n\n<thead>\n<tr>\n<th>Parameter<\/th>\n<th>Reference Value<\/th>\n<\/tr>\n<\/thead>\n\n<tbody>\n\n<tr>\n<td>Temperature During Bending<\/td><td>-20\u00b0C to +50\u00b0C<\/td>\n<\/tr>\n\n<tr>\n<td>Fixed Installation Temperature<\/td><td>-20\u00b0C to +70\u00b0C<\/td>\n<\/tr>\n\n<tr>\n<td>Minimum Bending Radius During Bending<\/td><td>15 x D<\/td>\n<\/tr>\n\n<tr>\n<td>Longitudinal Water Blocking<\/td><td>Yes<\/td>\n<\/tr>\n\n<tr>\n<td>Transverse Water Blocking<\/td><td>Yes<\/td>\n<\/tr>\n\n<tr>\n<td>Underground Installation<\/td><td>Suitable<\/td>\n<\/tr>\n\n<tr>\n<td>Conduit Installation<\/td><td>Suitable<\/td>\n<\/tr>\n\n<tr>\n<td>Cable Duct Installation<\/td><td>Suitable<\/td>\n<\/tr>\n\n<\/tbody>\n\n<\/table>\n\n<\/div>\n\n<h3>Minimum Cable Bending Radius<\/h3>\n\n<div class=\"table-wrap\">\n\n<table>\n\n<thead>\n<tr>\n<th>Cable Size<\/th>\n<th>Approx. Outer Diameter (mm)<\/th>\n<th>Calculated Minimum Bending Radius \u2013 15 x D (mm)<\/th>\n<\/tr>\n<\/thead>\n\n<tbody>\n\n<tr class=\"group-row\">\n<td colspan=\"3\">0.6 mm Conductor Diameter<\/td>\n<\/tr>\n\n<tr><td>2x2x0.6<\/td><td>8.3<\/td><td>124.5<\/td><\/tr>\n\n<tr><td>6x2x0.6<\/td><td>11.0<\/td><td>165<\/td><\/tr>\n\n<tr><td>10x2x0.6<\/td><td>12.5<\/td><td>187.5<\/td><\/tr>\n\n<tr><td>20x2x0.6<\/td><td>15.8<\/td><td>237<\/td><\/tr>\n\n<tr><td>30x2x0.6<\/td><td>19.0<\/td><td>285<\/td><\/tr>\n\n<tr><td>40x2x0.6<\/td><td>20.4<\/td><td>306<\/td><\/tr>\n\n<tr><td>50x2x0.6<\/td><td>22.2<\/td><td>333<\/td><\/tr>\n\n<tr><td>100x2x0.6<\/td><td>30.3<\/td><td>454.5<\/td><\/tr>\n\n<tr class=\"group-row\">\n<td colspan=\"3\">0.8 mm Conductor Diameter<\/td>\n<\/tr>\n\n<tr><td>2x2x0.8<\/td><td>8.8<\/td><td>132<\/td><\/tr>\n\n<tr><td>4x2x0.8<\/td><td>11.2<\/td><td>168<\/td><\/tr>\n\n<tr><td>6x2x0.8<\/td><td>12.0<\/td><td>180<\/td><\/tr>\n\n<tr><td>10x2x0.8<\/td><td>14.0<\/td><td>210<\/td><\/tr>\n\n<tr><td>20x2x0.8<\/td><td>19.1<\/td><td>286.5<\/td><\/tr>\n\n<tr><td>30x2x0.8<\/td><td>22.0<\/td><td>330<\/td><\/tr>\n\n<tr><td>40x2x0.8<\/td><td>24.0<\/td><td>360<\/td><\/tr>\n\n<tr><td>50x2x0.8<\/td><td>26.0<\/td><td>390<\/td><\/tr>\n\n<tr><td>100x2x0.8<\/td><td>36.0<\/td><td>540<\/td><\/tr>\n\n<tr><td>150x2x0.8<\/td><td>42.2<\/td><td>633<\/td><\/tr>\n\n<\/tbody>\n\n<\/table>\n\n<\/div>\n\n<p class=\"description\">\n\nThe minimum bending radii are calculated using the approximate outer diameters and the specified bending factor of 15 x D. Actual installation limits must be confirmed using the supplied cable dimensions.\n\n<\/p>\n\n<h3>Cable Construction Layers<\/h3>\n\n<div class=\"table-wrap\">\n\n<table>\n\n<thead>\n<tr>\n<th>Layer<\/th>\n<th>Component<\/th>\n<th>Material \/ Construction<\/th>\n<\/tr>\n<\/thead>\n\n<tbody>\n\n<tr>\n<td>1<\/td><td>Conductor<\/td><td>Solid Bare Copper, \u00d8 0.6 or 0.8 mm<\/td>\n<\/tr>\n\n<tr>\n<td>2<\/td><td>Core Insulation<\/td><td>Polyethylene (PE)<\/td>\n<\/tr>\n\n<tr>\n<td>3<\/td><td>Core Filling and Wrapping<\/td><td>Continuous Petrolatum Gel Filling and Plastic Foil<\/td>\n<\/tr>\n\n<tr>\n<td>4<\/td><td>Electrostatic Screen<\/td><td>Plastic-Coated Aluminium Tape<\/td>\n<\/tr>\n\n<tr>\n<td>5<\/td><td>Outer Sheath<\/td><td>Black Polyethylene (PE)<\/td>\n<\/tr>\n\n<\/tbody>\n\n<\/table>\n\n<\/div>\n\n<h3>Applicable Standards<\/h3>\n\n<div class=\"table-wrap\">\n\n<table>\n\n<thead>\n<tr>\n<th>Standard<\/th>\n<th>Reference Application<\/th>\n<\/tr>\n<\/thead>\n\n<tbody>\n\n<tr>\n<td>DIN VDE 0816<\/td><td>Core Identification<\/td>\n<\/tr>\n\n<tr>\n<td>DIN EN 60228, Class 1<\/td><td>Solid Conductor Construction<\/td>\n<\/tr>\n\n<\/tbody>\n\n<\/table>\n\n<\/div>\n\n<div class=\"notice\">\n\n<strong>Technical Note:<\/strong>\n\nAll cable dimensions, copper content and cable weights are indicative reference values. Cable sizes and technical configurations do not constitute a declaration of stock availability. Final technical specifications, installation conditions and applicable conformity documentation must be confirmed for the supplied product.\n\n<\/div>\n\n<div class=\"notice\">\n\n<strong>Data Verification:<\/strong>\n\nConductor diameters are expressed in millimetres, not square millimetres. Geometric conductor cross-sections and minimum bending radii are calculated values. The thickness column and insulation resistance unit are reproduced as stated in the reference documentation and require confirmation for engineering calculations. CPR classification, UV resistance, maximum tensile load and detailed core colour sequences are not specified.\n\n<\/div>\n\n<\/div>","protected":false},"excerpt":{"rendered":"<p>UNIMA CABLE | DATA &amp; COMMUNICATION CABLES A-2YF(L)2Y \u2013 Water-Blocked Telecommunications Cable PE-insulated copper telecommunications cable with star-quad construction, petrolatum gel filling, laminated aluminium screen and black polyethylene outer sheath. Designed for local communication networks, underground installations and low-frequency industrial communication systems. 2\u2013150 Pairs Solid Copper 0.6 \/ 0.8 mm PE Insulation Gel Filled Star-Quad [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":5727,"parent":0,"menu_order":0,"template":"","property_type":[199],"property_status":[],"property_feature":[],"property_label":[66,81,98],"property_country":[],"property_state":[],"property_city":[],"property_area":[],"class_list":["post-5726","property","type-property","status-publish","has-post-thumbnail","hentry","property_type-data-communication-cables","property_label-commercial-building","property_label-industrial-facilities","property_label-waterfront"],"acf":[],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 4.9.9 - aioseo.com -->\n\t<meta name=\"description\" content=\"A-2YF(L)2Y water-blocked telecommunications cable with copper conductors, PE insulation, aluminium screen and gel filling. DIN VDE 0816.\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<meta name=\"author\" content=\"admin\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/unima-cable.com\/hr\/property\/a-2yfl2y\/\" \/>\n\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 4.9.9\" \/>\n\t\t<meta property=\"og:locale\" content=\"hr_HR\" \/>\n\t\t<meta property=\"og:site_name\" content=\"Unima cable - Cable distribution\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"A-2YF(L)2Y Telecommunications Cable | UNIMA CABLE\" \/>\n\t\t<meta property=\"og:description\" content=\"A-2YF(L)2Y water-blocked telecommunications cable with copper conductors, PE insulation, aluminium screen and gel filling. DIN VDE 0816.\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/unima-cable.com\/hr\/property\/a-2yfl2y\/\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2026-11-25T14:05:19+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2026-11-25T14:05:19+00:00\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:title\" content=\"A-2YF(L)2Y Telecommunications Cable | UNIMA CABLE\" \/>\n\t\t<meta name=\"twitter:description\" content=\"A-2YF(L)2Y water-blocked telecommunications cable with copper conductors, PE insulation, aluminium screen and gel filling. DIN VDE 0816.\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property\\\/a-2yfl2y\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr#listItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/unima-cable.com\\\/hr\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property\\\/#listItem\",\"name\":\"Nekretnine\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property\\\/#listItem\",\"position\":2,\"name\":\"Nekretnine\",\"item\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property-type\\\/data-communication-cables\\\/#listItem\",\"name\":\"Data &amp; Communication Cables\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr#listItem\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property-type\\\/data-communication-cables\\\/#listItem\",\"position\":3,\"name\":\"Data &amp; Communication Cables\",\"item\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property-type\\\/data-communication-cables\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property\\\/a-2yfl2y\\\/#listItem\",\"name\":\"A-2YF(L)2Y\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property\\\/#listItem\",\"name\":\"Nekretnine\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property\\\/a-2yfl2y\\\/#listItem\",\"position\":4,\"name\":\"A-2YF(L)2Y\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property-type\\\/data-communication-cables\\\/#listItem\",\"name\":\"Data &amp; Communication Cables\"}}]},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/#organization\",\"name\":\"Unima cable\",\"description\":\"Cable distribution\",\"url\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/author\\\/admin\\\/#author\",\"url\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/author\\\/admin\\\/\",\"name\":\"admin\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property\\\/a-2yfl2y\\\/#authorImage\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/c5cd64316e8c316b90636704903a98dab06fc1cbc5559bb333833e1a7005aae2?s=96&d=mm&r=g\",\"width\":96,\"height\":96,\"caption\":\"admin\"}},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property\\\/a-2yfl2y\\\/#webpage\",\"url\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property\\\/a-2yfl2y\\\/\",\"name\":\"A-2YF(L)2Y Telecommunications Cable | UNIMA CABLE\",\"description\":\"A-2YF(L)2Y water-blocked telecommunications cable with copper conductors, PE insulation, aluminium screen and gel filling. DIN VDE 0816.\",\"inLanguage\":\"hr\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property\\\/a-2yfl2y\\\/#breadcrumblist\"},\"author\":{\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/author\\\/admin\\\/#author\"},\"creator\":{\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/author\\\/admin\\\/#author\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/unima-cable.com\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/Detaljan-presjek-viseslojnog-kabela.png\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property\\\/a-2yfl2y\\\/#mainImage\",\"width\":1536,\"height\":1024},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property\\\/a-2yfl2y\\\/#mainImage\"},\"datePublished\":\"2026-11-25T14:05:19+00:00\",\"dateModified\":\"2026-11-25T14:05:19+00:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/#website\",\"url\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/\",\"name\":\"Unima cable\",\"description\":\"Cable distribution\",\"inLanguage\":\"hr\",\"publisher\":{\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/#organization\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"A-2YF(L)2Y Telecommunications Cable | UNIMA CABLE","description":"A-2YF(L)2Y water-blocked telecommunications cable with copper conductors, PE insulation, aluminium screen and gel filling. DIN VDE 0816.","canonical_url":"https:\/\/unima-cable.com\/hr\/property\/a-2yfl2y\/","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"BreadcrumbList","@id":"https:\/\/unima-cable.com\/hr\/property\/a-2yfl2y\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/unima-cable.com\/hr#listItem","position":1,"name":"Home","item":"https:\/\/unima-cable.com\/hr","nextItem":{"@type":"ListItem","@id":"https:\/\/unima-cable.com\/hr\/property\/#listItem","name":"Nekretnine"}},{"@type":"ListItem","@id":"https:\/\/unima-cable.com\/hr\/property\/#listItem","position":2,"name":"Nekretnine","item":"https:\/\/unima-cable.com\/hr\/property\/","nextItem":{"@type":"ListItem","@id":"https:\/\/unima-cable.com\/hr\/property-type\/data-communication-cables\/#listItem","name":"Data &amp; Communication Cables"},"previousItem":{"@type":"ListItem","@id":"https:\/\/unima-cable.com\/hr#listItem","name":"Home"}},{"@type":"ListItem","@id":"https:\/\/unima-cable.com\/hr\/property-type\/data-communication-cables\/#listItem","position":3,"name":"Data &amp; Communication Cables","item":"https:\/\/unima-cable.com\/hr\/property-type\/data-communication-cables\/","nextItem":{"@type":"ListItem","@id":"https:\/\/unima-cable.com\/hr\/property\/a-2yfl2y\/#listItem","name":"A-2YF(L)2Y"},"previousItem":{"@type":"ListItem","@id":"https:\/\/unima-cable.com\/hr\/property\/#listItem","name":"Nekretnine"}},{"@type":"ListItem","@id":"https:\/\/unima-cable.com\/hr\/property\/a-2yfl2y\/#listItem","position":4,"name":"A-2YF(L)2Y","previousItem":{"@type":"ListItem","@id":"https:\/\/unima-cable.com\/hr\/property-type\/data-communication-cables\/#listItem","name":"Data &amp; Communication Cables"}}]},{"@type":"Organization","@id":"https:\/\/unima-cable.com\/hr\/#organization","name":"Unima cable","description":"Cable distribution","url":"https:\/\/unima-cable.com\/hr\/"},{"@type":"Person","@id":"https:\/\/unima-cable.com\/hr\/author\/admin\/#author","url":"https:\/\/unima-cable.com\/hr\/author\/admin\/","name":"admin","image":{"@type":"ImageObject","@id":"https:\/\/unima-cable.com\/hr\/property\/a-2yfl2y\/#authorImage","url":"https:\/\/secure.gravatar.com\/avatar\/c5cd64316e8c316b90636704903a98dab06fc1cbc5559bb333833e1a7005aae2?s=96&d=mm&r=g","width":96,"height":96,"caption":"admin"}},{"@type":"WebPage","@id":"https:\/\/unima-cable.com\/hr\/property\/a-2yfl2y\/#webpage","url":"https:\/\/unima-cable.com\/hr\/property\/a-2yfl2y\/","name":"A-2YF(L)2Y Telecommunications Cable | UNIMA CABLE","description":"A-2YF(L)2Y water-blocked telecommunications cable with copper conductors, PE insulation, aluminium screen and gel filling. DIN VDE 0816.","inLanguage":"hr","isPartOf":{"@id":"https:\/\/unima-cable.com\/hr\/#website"},"breadcrumb":{"@id":"https:\/\/unima-cable.com\/hr\/property\/a-2yfl2y\/#breadcrumblist"},"author":{"@id":"https:\/\/unima-cable.com\/hr\/author\/admin\/#author"},"creator":{"@id":"https:\/\/unima-cable.com\/hr\/author\/admin\/#author"},"image":{"@type":"ImageObject","url":"https:\/\/unima-cable.com\/wp-content\/uploads\/2026\/11\/Detaljan-presjek-viseslojnog-kabela.png","@id":"https:\/\/unima-cable.com\/hr\/property\/a-2yfl2y\/#mainImage","width":1536,"height":1024},"primaryImageOfPage":{"@id":"https:\/\/unima-cable.com\/hr\/property\/a-2yfl2y\/#mainImage"},"datePublished":"2026-11-25T14:05:19+00:00","dateModified":"2026-11-25T14:05:19+00:00"},{"@type":"WebSite","@id":"https:\/\/unima-cable.com\/hr\/#website","url":"https:\/\/unima-cable.com\/hr\/","name":"Unima cable","description":"Cable distribution","inLanguage":"hr","publisher":{"@id":"https:\/\/unima-cable.com\/hr\/#organization"}}]},"og:locale":"hr_HR","og:site_name":"Unima cable - Cable distribution","og:type":"article","og:title":"A-2YF(L)2Y Telecommunications Cable | UNIMA CABLE","og:description":"A-2YF(L)2Y water-blocked telecommunications cable with copper conductors, PE insulation, aluminium screen and gel filling. DIN VDE 0816.","og:url":"https:\/\/unima-cable.com\/hr\/property\/a-2yfl2y\/","article:published_time":"2026-11-25T14:05:19+00:00","article:modified_time":"2026-11-25T14:05:19+00:00","twitter:card":"summary_large_image","twitter:title":"A-2YF(L)2Y Telecommunications Cable | UNIMA CABLE","twitter:description":"A-2YF(L)2Y water-blocked telecommunications cable with copper conductors, PE insulation, aluminium screen and gel filling. DIN VDE 0816."},"aioseo_meta_data":{"post_id":"5726","title":"A-2YF(L)2Y Telecommunications Cable | UNIMA CABLE","description":"A-2YF(L)2Y water-blocked telecommunications cable with copper conductors, PE insulation, aluminium screen and gel filling. DIN VDE 0816.","keywords":null,"keyphrases":{"focus":{"keyphrase":"","score":0,"analysis":{"keyphraseInTitle":{"score":0,"maxScore":9,"error":1}}},"additional":[]},"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_custom_url":null,"og_image_custom_fields":null,"og_image_url":null,"og_image_width":null,"og_image_height":null,"og_video":"","og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_image_url":null,"twitter_title":null,"twitter_description":null,"schema_type":"default","schema_type_options":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"WebPage","isEnabled":true},"graphs":[]},"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":"-1","robots_max_videopreview":"-1","robots_max_imagepreview":"large","priority":null,"frequency":"default","local_seo":null,"limit_modified_date":false,"ai":{"faqs":[],"keyPoints":[],"schemas":[],"titles":[],"descriptions":[],"socialPosts":{"email":{"subject":"","preview":"","content":""},"linkedin":[],"twitter":[],"facebook":[],"instagram":[]}},"breadcrumb_settings":null,"seo_analyzer_scan_date":null,"created":"2026-11-25 14:05:19","updated":"2026-11-25 14:39:51"},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/unima-cable.com\/hr\" title=\"Home\">Home<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/unima-cable.com\/hr\/property\/\" title=\"Nekretnine\">Nekretnine<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/unima-cable.com\/hr\/property-type\/data-communication-cables\/\" title=\"Data &amp; Communication Cables\">Data &amp; Communication Cables<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\tA-2YF(L)2Y\n\t\t<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"Home","link":"https:\/\/unima-cable.com\/hr"},{"label":"Nekretnine","link":"https:\/\/unima-cable.com\/hr\/property\/"},{"label":"Data &amp; Communication Cables","link":"https:\/\/unima-cable.com\/hr\/property-type\/data-communication-cables\/"},{"label":"A-2YF(L)2Y","link":"https:\/\/unima-cable.com\/hr\/property\/a-2yfl2y\/"}],"property_meta":{"_edit_lock":["1795615526:1"],"_thumbnail_id":["5727"],"_edit_last":["1"],"fave_show_price_placeholder":["0"],"fave_availability":["Stock"],"fave_property_map":["1"],"fave_property_location":["25.68654,-80.431345,15"],"houzez_geolocation_lat":["25.68654"],"houzez_geolocation_long":["-80.431345"],"fave_property_map_street_view":["hide"],"fave_featured":["0"],"houzez_featured_listing_date":[""],"fave_loggedintoview":["0"],"fave_agent_display_option":["author_info"],"fave_prop_homeslider":["no"],"fave_single_top_area":["global"],"fave_single_content_area":["global"],"technical_datasheet":[""],"_technical_datasheet":["field_6a8040c7beb2c"],"dop":[""],"_dop":["field_6a8041aba97aa"],"cpr_certificate":[""],"_cpr_certificate":["field_6a8041ebd3dd6"],"installation_guide":[""],"_installation_guide":["field_6a80420faf22d"],"cable_calculator_data":[""],"_cable_calculator_data":["field_6a816609a8215"],"datasheet_product_subtitle":[""],"_datasheet_product_subtitle":["field_6ab7857caa586"],"datasheet_description":[""],"_datasheet_description":["field_6ab785aaaa587"],"datasheet_construction":[""],"_datasheet_construction":["field_6ab7866c910b7"],"datasheet_standards":[""],"_datasheet_standards":["field_6ab7869f81536"],"datasheet_applications":[""],"_datasheet_applications":["field_6ab786d7788a3"],"datasheet_technical_data":[""],"_datasheet_technical_data":["field_6ab7870017566"],"datasheet_size_data":[""],"_datasheet_size_data":["field_6ab787279d659"],"datasheet_highlights":[""],"_datasheet_highlights":["field_6ad9232e89762"],"datasheet_category":[""],"_datasheet_category":["field_6ad929e8ec019"],"datasheet_technical_notes":[""],"_datasheet_technical_notes":["field_6ad92a005051a"],"datasheet_cpr_class":[""],"_datasheet_cpr_class":["field_6ad92a1bdd6aa"],"_aioseo_title":["A-2YF(L)2Y Telecommunications Cable | UNIMA CABLE"],"_aioseo_description":["A-2YF(L)2Y water-blocked telecommunications cable with copper conductors, PE insulation, aluminium screen and gel filling. DIN VDE 0816."],"_aioseo_og_title":[""],"_aioseo_og_description":[""],"_aioseo_og_article_section":[""],"_aioseo_twitter_title":[""],"_aioseo_twitter_description":[""],"_aioseo_keywords":["a:0:{}"],"_aioseo_og_article_tags":["a:0:{}"],"unima_cable_designation":[""],"unima_cable_aliases":[""],"houzez_manual_expire":["0"],"_houzez_expiration_date_status":["saved"],"houzez_total_property_views":["34"],"houzez_views_by_date":["a:5:{s:10:\"11-25-2026\";i:7;s:10:\"11-26-2026\";i:14;s:10:\"11-27-2026\";i:6;s:10:\"11-28-2026\";i:4;s:10:\"11-29-2026\";i:3;}"],"houzez_recently_viewed":["2026-11-29 15:11:40"],"_elementor_page_assets":["a:0:{}"]},"_links":{"self":[{"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/properties\/5726","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/properties"}],"about":[{"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/types\/property"}],"author":[{"embeddable":true,"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/users\/1"}],"version-history":[{"count":1,"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/properties\/5726\/revisions"}],"predecessor-version":[{"id":5728,"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/properties\/5726\/revisions\/5728"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/media\/5727"}],"wp:attachment":[{"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/media?parent=5726"}],"wp:term":[{"taxonomy":"property_type","embeddable":true,"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/property_type?post=5726"},{"taxonomy":"property_status","embeddable":true,"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/property_status?post=5726"},{"taxonomy":"property_feature","embeddable":true,"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/property_feature?post=5726"},{"taxonomy":"property_label","embeddable":true,"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/property_label?post=5726"},{"taxonomy":"property_country","embeddable":true,"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/property_country?post=5726"},{"taxonomy":"property_state","embeddable":true,"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/property_state?post=5726"},{"taxonomy":"property_city","embeddable":true,"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/property_city?post=5726"},{"taxonomy":"property_area","embeddable":true,"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/property_area?post=5726"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}