{"id":5713,"date":"2026-11-25T10:49:04","date_gmt":"2026-11-25T10:49:04","guid":{"rendered":"https:\/\/unima-cable.com\/?post_type=property&#038;p=5713"},"modified":"2026-11-25T10:49:05","modified_gmt":"2026-11-25T10:49:05","slug":"j-ysty","status":"publish","type":"property","link":"https:\/\/unima-cable.com\/hr\/property\/j-ysty\/","title":{"rendered":"J-Y(ST)Y"},"content":{"rendered":"<div id=\"unima-jysty-overview\">\n\n<style>\n#unima-jysty-overview{font-family:Arial,Helvetica,sans-serif;color:#071a2d;line-height:1.65;margin:24px 0}\n#unima-jysty-overview *{box-sizing:border-box}\n#unima-jysty-overview .hero{background:linear-gradient(120deg,#071a2d,#164263);color:#fff;padding:30px;border-radius:13px}\n#unima-jysty-overview .eyebrow{color:#8bd5ff;letter-spacing:2px;font-weight:bold;font-size:11px}\n#unima-jysty-overview .hero h2{color:#fff;font-size:26px;margin:5px 0 12px}\n#unima-jysty-overview .hero p{color:#d9eaf5;margin:0;font-size:14px}\n#unima-jysty-overview .tags{display:flex;flex-wrap:wrap;gap:8px;margin-top:18px}\n#unima-jysty-overview .tags span{border:1px solid #55758c;background:#173d5c;color:#fff;border-radius:20px;padding:6px 12px;font-size:12px}\n#unima-jysty-overview h3{color:#071a2d;font-size:19px;border-left:4px solid #0878c9;padding-left:12px;margin:27px 0 15px}\n#unima-jysty-overview .panel{border:1px solid #dce7ef;border-radius:10px;overflow:hidden}\n#unima-jysty-overview .copy{padding:20px;color:#354b60;font-size:14px}\n#unima-jysty-overview .copy p{margin:0 0 12px}\n#unima-jysty-overview .copy p:last-child{margin-bottom:0}\n#unima-jysty-overview .stats{display:grid;grid-template-columns:repeat(4,1fr);gap:10px}\n#unima-jysty-overview .stat{background:#f2f8fc;border:1px solid #dce7ef;border-radius:9px;padding:17px 8px;text-align:center}\n#unima-jysty-overview .stat b{display:block;font-size:21px}\n#unima-jysty-overview .stat small{color:#607487;font-size:11px}\n#unima-jysty-overview .columns{display:grid;grid-template-columns:1fr 1fr;gap:16px}\n#unima-jysty-overview h4{background:#102d48;color:#fff;margin:0;padding:13px;font-size:14px}\n#unima-jysty-overview .item{display:grid;grid-template-columns:minmax(0,45fr) minmax(0,55fr);padding:10px 13px;border-bottom:1px solid #e5edf3;font-size:12px;gap:6px}\n#unima-jysty-overview .item span{color:#607487}\n#unima-jysty-overview .item strong{overflow-wrap:anywhere}\n#unima-jysty-overview .apps{display:grid;grid-template-columns:1fr 1fr;gap:10px}\n#unima-jysty-overview .app{background:#f2f8fc;border:1px solid #dce7ef;border-radius:8px;padding:12px;font-size:13px}\n#unima-jysty-overview .app:before{content:\"\u2713\";color:#0878c9;font-weight:bold;margin-right:8px}\n#unima-jysty-overview .notice{background:#f2f8fc;border-left:4px solid #0878c9;padding:16px;margin-top:22px;font-size:12px;color:#43586b}\n@media(max-width:700px){\n#unima-jysty-overview .stats{grid-template-columns:repeat(2,1fr)}\n#unima-jysty-overview .columns,#unima-jysty-overview .apps{grid-template-columns:1fr}\n#unima-jysty-overview .hero{padding:22px}\n#unima-jysty-overview .hero h2{font-size:22px}\n}\n<\/style>\n\n<div class=\"hero\">\n\n<div class=\"eyebrow\">UNIMA CABLE | DATA &amp; COMMUNICATION CABLES<\/div>\n\n<h2>J-Y(ST)Y \u2013 Shielded Telecommunication Installation Cable<\/h2>\n\n<p>Shielded indoor telecommunication installation cable with solid bare copper conductors, PVC core insulation, aluminium foil static screen with drain wire and a grey PVC outer sheath. Designed for fixed indoor telecommunication installations.<\/p>\n\n<div class=\"tags\">\n<span>300 V Peak<\/span>\n<span>Solid Copper Class 1<\/span>\n<span>0.6 \/ 0.8 mm<\/span>\n<span>PVC Insulation<\/span>\n<span>Aluminium Foil Screen<\/span>\n<span>PVC Sheath<\/span>\n<span>DIN VDE 0815<\/span>\n<span>Indoor Installation<\/span>\n<\/div>\n\n<\/div>\n\n<h3>Product Overview<\/h3>\n\n<div class=\"panel copy\">\n\n<p><strong>J-Y(ST)Y<\/strong> is a shielded telecommunication installation cable designed for permanent fixed installation in indoor communication systems.<\/p>\n\n<p>The cable incorporates solid bare copper conductors with nominal conductor diameters of 0.6 mm or 0.8 mm. Each conductor is insulated with polyvinyl chloride (PVC).<\/p>\n\n<p>A static screen consisting of plastic-coated aluminium foil with a drain wire provides electrostatic shielding for the communication circuits.<\/p>\n\n<p>The cable construction is completed with a grey PVC outer sheath suitable for the specified indoor installation conditions.<\/p>\n\n<p>The reference product range includes configurations from 1 to 100 pairs, depending on the selected conductor diameter.<\/p>\n\n<\/div>\n\n<h3>Key Technical Features<\/h3>\n\n<div class=\"stats\">\n\n<div class=\"stat\">\n<b>300 V<\/b>\n<small>Peak Operating Voltage<\/small>\n<\/div>\n\n<div class=\"stat\">\n<b>1\u2013100<\/b>\n<small>Number of Pairs<\/small>\n<\/div>\n\n<div class=\"stat\">\n<b>0.6 \/ 0.8 mm<\/b>\n<small>Conductor Diameter<\/small>\n<\/div>\n\n<div class=\"stat\">\n<b>+70\u00b0C<\/b>\n<small>Maximum Fixed Installation Temperature<\/small>\n<\/div>\n\n<\/div>\n\n<h3>Cable Variants<\/h3>\n\n<div class=\"columns\">\n\n<div class=\"panel\">\n<h4>J-Y(ST)Y \u2013 0.6 mm<\/h4>\n\n<div class=\"copy\">\n<p><strong>Solid Copper Conductor Diameter: 0.6 mm<\/strong><\/p>\n\n<p>Reference configurations from 1 to 100 pairs, with a conductor loop resistance of 130.0 \u03a9\/km.<\/p>\n\n<p>Approximate cable diameters range from 4.5 to 22.1 mm.<\/p>\n<\/div>\n<\/div>\n\n<div class=\"panel\">\n<h4>J-Y(ST)Y \u2013 0.8 mm<\/h4>\n\n<div class=\"copy\">\n<p><strong>Solid Copper Conductor Diameter: 0.8 mm<\/strong><\/p>\n\n<p>Reference configurations from 1 to 60 pairs, with a conductor loop resistance of 73.2 \u03a9\/km.<\/p>\n\n<p>Approximate cable diameters range from 5.5 to 25.8 mm.<\/p>\n<\/div>\n<\/div>\n\n<\/div>\n\n<h3>Cable Designation<\/h3>\n\n<div class=\"panel\">\n\n<div class=\"item\">\n<span>J<\/span>\n<strong>Indoor Installation Cable<\/strong>\n<\/div>\n\n<div class=\"item\">\n<span>Y<\/span>\n<strong>PVC Core Insulation<\/strong>\n<\/div>\n\n<div class=\"item\">\n<span>(ST)<\/span>\n<strong>Static Screen<\/strong>\n<\/div>\n\n<div class=\"item\">\n<span>Y<\/span>\n<strong>PVC Outer Sheath<\/strong>\n<\/div>\n\n<\/div>\n\n<h3>Construction &amp; Technical Properties<\/h3>\n\n<div class=\"columns\">\n\n<div class=\"panel\">\n\n<h4>Cable Construction<\/h4>\n\n<div class=\"item\">\n<span>Materijal vodi\u010da<\/span>\n<strong>Bare Copper<\/strong>\n<\/div>\n\n<div class=\"item\">\n<span>Conductor Class<\/span>\n<strong>Class 1, Solid<\/strong>\n<\/div>\n\n<div class=\"item\">\n<span>Conductor Diameter<\/span>\n<strong>0.6 mm \/ 0.8 mm<\/strong>\n<\/div>\n\n<div class=\"item\">\n<span>Core Insulation<\/span>\n<strong>PVC<\/strong>\n<\/div>\n\n<div class=\"item\">\n<span>Core Identification<\/span>\n<strong>DIN VDE 0815<\/strong>\n<\/div>\n\n<div class=\"item\">\n<span>Static Screen<\/span>\n<strong>Plastic-Coated Aluminium Foil<\/strong>\n<\/div>\n\n<div class=\"item\">\n<span>Drain Wire<\/span>\n<strong>Yes<\/strong>\n<\/div>\n\n<div class=\"item\">\n<span>Outer Sheath<\/span>\n<strong>PVC<\/strong>\n<\/div>\n\n<div class=\"item\">\n<span>Sheath Colour<\/span>\n<strong>Grey<\/strong>\n<\/div>\n\n<div class=\"item\">\n<span>Number of Pairs \u2013 0.6 mm<\/span>\n<strong>1\u2013100<\/strong>\n<\/div>\n\n<div class=\"item\">\n<span>Number of Pairs \u2013 0.8 mm<\/span>\n<strong>1\u201360<\/strong>\n<\/div>\n\n<div class=\"item\">\n<span>Installation Type<\/span>\n<strong>Fixed Indoor Installation<\/strong>\n<\/div>\n\n<\/div>\n\n<div class=\"panel\">\n\n<h4>Electrical &amp; Mechanical Data<\/h4>\n\n<div class=\"item\">\n<span>Peak Operating Voltage<\/span>\n<strong>300 V<\/strong>\n<\/div>\n\n<div class=\"item\">\n<span>Test Voltage \u2013 Core\/Core<\/span>\n<strong>800 V AC, 50 Hz<\/strong>\n<\/div>\n\n<div class=\"item\">\n<span>Test Voltage \u2013 Core\/Screen<\/span>\n<strong>800 V AC, 50 Hz<\/strong>\n<\/div>\n\n<div class=\"item\">\n<span>Loop Resistance \u2013 0.6 mm<\/span>\n<strong>130.0 \u03a9\/km<\/strong>\n<\/div>\n\n<div class=\"item\">\n<span>Loop Resistance \u2013 0.8 mm<\/span>\n<strong>73.2 \u03a9\/km<\/strong>\n<\/div>\n\n<div class=\"item\">\n<span>Minimum Insulation Resistance<\/span>\n<strong>100 M\u03a9\/km (as stated)<\/strong>\n<\/div>\n\n<div class=\"item\">\n<span>Maximum Operating Capacitance<\/span>\n<strong>10 nF\/km \u2013 To Be Confirmed<\/strong>\n<\/div>\n\n<div class=\"item\">\n<span>Capacitance Unbalance<\/span>\n<strong>Max. 300 pF \/ 100 m<\/strong>\n<\/div>\n\n<div class=\"item\">\n<span>Temperature During Bending<\/span>\n<strong>-5\u00b0C to +50\u00b0C<\/strong>\n<\/div>\n\n<div class=\"item\">\n<span>Fixed Installation Temperature<\/span>\n<strong>-30\u00b0C to +70\u00b0C<\/strong>\n<\/div>\n\n<div class=\"item\">\n<span>Minimum Bending Radius<\/span>\n<strong>15 x Cable Diameter<\/strong>\n<\/div>\n\n<div class=\"item\">\n<span>Flame Test References<\/span>\n<strong>EN 60332-1-2 \/ EN 60332-2-2<\/strong>\n<\/div>\n\n<\/div>\n\n<\/div>\n\n<h3>Typical Applications<\/h3>\n\n<div class=\"apps\">\n\n<div class=\"app\">Indoor Telecommunication Systems<\/div>\n\n<div class=\"app\">Telephone Installation Networks<\/div>\n\n<div class=\"app\">Fixed Communication Wiring<\/div>\n\n<div class=\"app\">Commercial Building Communications<\/div>\n\n<div class=\"app\">Industrial Facility Communication Systems<\/div>\n\n<div class=\"app\">Indoor Utility Communication Infrastructure<\/div>\n\n<\/div>\n\n<h3>Applicable Standards<\/h3>\n\n<div class=\"panel copy\">\n\n<p><strong>DIN VDE 0815<\/strong> \u2013 Reference standard for core identification of telecommunication installation cables.<\/p>\n\n<p><strong>DIN EN 60228, Class 1<\/strong> \u2013 Solid conductor construction, as referenced in the technical documentation.<\/p>\n\n<p><strong>EN 60332-1-2<\/strong> \u2013 Vertical flame propagation test for a single insulated wire or cable.<\/p>\n\n<p><strong>EN 60332-2-2<\/strong> \u2013 Vertical flame propagation test for small insulated wires or cables.<\/p>\n\n<\/div>\n\n<h3>Installation Conditions<\/h3>\n\n<div class=\"panel copy\">\n\n<p>J-Y(ST)Y is intended for fixed telecommunication installations inside buildings.<\/p>\n\n<p>The permitted temperature range during bending is -5\u00b0C to +50\u00b0C. Once installed in a fixed position, the specified temperature range is -30\u00b0C to +70\u00b0C.<\/p>\n\n<p>A minimum bending radius of 15 times the cable outer diameter must be maintained during bending.<\/p>\n\n<p>The cable is intended for communication applications and is not specified as a general-purpose power distribution cable.<\/p>\n\n<\/div>\n\n<div class=\"notice\">\n\n<strong>Technical Note:<\/strong>\n\nThe 300 V value represents the peak operating voltage and must not be interpreted as a rated power cable voltage. Conductor sizes of 0.6 mm and 0.8 mm refer to conductor diameter, not cross-sectional area in mm\u00b2. The operating capacitance of 10 nF\/km and the insulation resistance unit are reproduced from the reference documentation and require confirmation. CPR classification, outdoor installation, direct burial suitability and circuit integrity performance are not specified. All technical characteristics must be confirmed for the supplied product.\n\n<\/div>\n\n<\/div>\n\n\n\n<div id=\"unima-jysty-sizes\">\n\n<style>\n#unima-jysty-sizes{font-family:Arial,Helvetica,sans-serif;color:#071a2d;line-height:1.6;margin:24px 0 35px}\n#unima-jysty-sizes *{box-sizing:border-box}\n#unima-jysty-sizes .hero{background:linear-gradient(120deg,#071a2d,#164263);color:#fff;padding:30px;border-radius:13px}\n#unima-jysty-sizes .eyebrow{color:#8bd5ff;letter-spacing:2px;font-weight:bold;font-size:11px}\n#unima-jysty-sizes .hero h2{color:#fff;font-size:26px;margin:6px 0 12px}\n#unima-jysty-sizes .hero p{color:#d9eaf5;margin:0;font-size:14px}\n#unima-jysty-sizes h3{color:#071a2d;font-size:19px;border-left:4px solid #0878c9;padding-left:12px;margin:27px 0 15px}\n#unima-jysty-sizes .table-wrap{overflow-x:auto;border:1px solid #dce7ef;border-radius:10px}\n#unima-jysty-sizes table{width:100%;min-width:600px;border-collapse:collapse;font-size:12px}\n#unima-jysty-sizes .wide table{min-width:900px}\n#unima-jysty-sizes th{background:#102d48;color:#fff;padding:12px 9px;text-align:left;vertical-align:middle}\n#unima-jysty-sizes td{padding:10px 9px;border-bottom:1px solid #e5edf3;vertical-align:middle}\n#unima-jysty-sizes tbody tr:nth-child(even){background:#f2f8fc}\n#unima-jysty-sizes td:first-child{font-weight:bold;color:#0878c9}\n#unima-jysty-sizes td:last-child{font-weight:bold;color:#0878c9}\n#unima-jysty-sizes .group-row td{background:#dcebf5!important;color:#102d48!important;font-size:13px;font-weight:bold;padding:12px}\n#unima-jysty-sizes .stats{display:grid;grid-template-columns:repeat(4,1fr);gap:10px;margin-top:20px}\n#unima-jysty-sizes .stat{background:#f2f8fc;border:1px solid #dce7ef;border-radius:9px;padding:17px 8px;text-align:center}\n#unima-jysty-sizes .stat b{display:block;font-size:19px}\n#unima-jysty-sizes .stat small{color:#607487;font-size:11px}\n#unima-jysty-sizes .notice{background:#f2f8fc;border-left:4px solid #0878c9;padding:16px;margin-top:22px;font-size:12px;color:#43586b}\n#unima-jysty-sizes .description{font-size:13px;color:#43586b;margin:12px 0}\n@media(max-width:700px){\n#unima-jysty-sizes .hero{padding:22px}\n#unima-jysty-sizes .hero h2{font-size:22px}\n#unima-jysty-sizes .stats{grid-template-columns:repeat(2,1fr)}\n}\n<\/style>\n\n<div class=\"hero\">\n\n<div class=\"eyebrow\">UNIMA CABLE | TECHNICAL DIMENSIONS<\/div>\n\n<h2>J-Y(ST)Y \u2013 Cable Sizes &amp; Technical Data<\/h2>\n\n<p>28 reference configurations of shielded telecommunication installation cables with solid copper conductors, nominal conductor diameters of 0.6 mm and 0.8 mm, copper content, insulation thickness, outer diameter and approximate cable weight.<\/p>\n\n<\/div>\n\n<div class=\"stats\">\n\n<div class=\"stat\">\n<b>28<\/b>\n<small>Reference Configurations<\/small>\n<\/div>\n\n<div class=\"stat\">\n<b>1\u2013100<\/b>\n<small>Number of Pairs<\/small>\n<\/div>\n\n<div class=\"stat\">\n<b>0.6 \/ 0.8 mm<\/b>\n<small>Conductor Diameter<\/small>\n<\/div>\n\n<div class=\"stat\">\n<b>26\u2013978 kg\/km<\/b>\n<small>Cable Weight<\/small>\n<\/div>\n\n<\/div>\n\n<h3>Available Cable Sizes &amp; Dimensions<\/h3>\n\n<div class=\"table-wrap wide\">\n\n<table>\n\n<thead>\n\n<tr>\n<th>Tip kabela<\/th>\n<th>Configuration<\/th>\n<th>Number of Pairs<\/th>\n<th>Conductor Diameter (mm)<\/th>\n<th>Copper Content (kg\/km)<\/th>\n<th>Insulation Thickness (mm)<\/th>\n<th>Approx. Outer Diameter (mm)<\/th>\n<th>Approx. Cable Weight (kg\/km)<\/th>\n<\/tr>\n\n<\/thead>\n\n<tbody>\n\n<tr class=\"group-row\">\n<td colspan=\"8\">J-Y(ST)Y \u2013 Solid Copper Conductor \u00d8 0.6 mm<\/td>\n<\/tr>\n\n<tr><td>J-Y(ST)Y<\/td><td>1x2x0.6<\/td><td>1<\/td><td>0.6<\/td><td>6.7<\/td><td>1.1<\/td><td>4.5<\/td><td>26<\/td><\/tr>\n\n<tr><td>J-Y(ST)Y<\/td><td>2x2x0.6<\/td><td>2<\/td><td>0.6<\/td><td>12.5<\/td><td>1.1<\/td><td>4.9<\/td><td>35<\/td><\/tr>\n\n<tr><td>J-Y(ST)Y<\/td><td>3x2x0.6<\/td><td>3<\/td><td>0.6<\/td><td>18.2<\/td><td>1.1<\/td><td>6.2<\/td><td>49<\/td><\/tr>\n\n<tr><td>J-Y(ST)Y<\/td><td>4x2x0.6<\/td><td>4<\/td><td>0.6<\/td><td>23.0<\/td><td>1.1<\/td><td>6.6<\/td><td>58<\/td><\/tr>\n\n<tr><td>J-Y(ST)Y<\/td><td>5x2x0.6<\/td><td>5<\/td><td>0.6<\/td><td>28.8<\/td><td>1.1<\/td><td>7.1<\/td><td>59<\/td><\/tr>\n\n<tr><td>J-Y(ST)Y<\/td><td>6x2x0.6<\/td><td>6<\/td><td>0.6<\/td><td>34.6<\/td><td>1.1<\/td><td>7.6<\/td><td>61<\/td><\/tr>\n\n<tr><td>J-Y(ST)Y<\/td><td>10x2x0.6<\/td><td>10<\/td><td>0.6<\/td><td>56.6<\/td><td>1.1<\/td><td>9.3<\/td><td>113<\/td><\/tr>\n\n<tr><td>J-Y(ST)Y<\/td><td>12x2x0.6<\/td><td>12<\/td><td>0.6<\/td><td>69.1<\/td><td>1.1<\/td><td>9.5<\/td><td>129<\/td><\/tr>\n\n<tr><td>J-Y(ST)Y<\/td><td>20x2x0.6<\/td><td>20<\/td><td>0.6<\/td><td>111.4<\/td><td>1.1<\/td><td>10.9<\/td><td>191<\/td><\/tr>\n\n<tr><td>J-Y(ST)Y<\/td><td>30x2x0.6<\/td><td>30<\/td><td>0.6<\/td><td>165.1<\/td><td>1.3<\/td><td>13.7<\/td><td>284<\/td><\/tr>\n\n<tr><td>J-Y(ST)Y<\/td><td>40x2x0.6<\/td><td>40<\/td><td>0.6<\/td><td>218.9<\/td><td>1.3<\/td><td>14.5<\/td><td>358<\/td><\/tr>\n\n<tr><td>J-Y(ST)Y<\/td><td>50x2x0.6<\/td><td>50<\/td><td>0.6<\/td><td>273.6<\/td><td>1.3<\/td><td>16.5<\/td><td>438<\/td><\/tr>\n\n<tr><td>J-Y(ST)Y<\/td><td>60x2x0.6<\/td><td>60<\/td><td>0.6<\/td><td>328.3<\/td><td>1.3<\/td><td>17.5<\/td><td>512<\/td><\/tr>\n\n<tr><td>J-Y(ST)Y<\/td><td>100x2x0.6<\/td><td>100<\/td><td>0.6<\/td><td>545.3<\/td><td>1.5<\/td><td>22.1<\/td><td>829<\/td><\/tr>\n\n\n<tr class=\"group-row\">\n<td colspan=\"8\">J-Y(ST)Y \u2013 Solid Copper Conductor \u00d8 0.8 mm<\/td>\n<\/tr>\n\n<tr><td>J-Y(ST)Y<\/td><td>1x2x0.8<\/td><td>1<\/td><td>0.8<\/td><td>10.6<\/td><td>1.1<\/td><td>5.5<\/td><td>38<\/td><\/tr>\n\n<tr><td>J-Y(ST)Y<\/td><td>2x2x0.8<\/td><td>2<\/td><td>0.8<\/td><td>20.2<\/td><td>1.1<\/td><td>6.1<\/td><td>54<\/td><\/tr>\n\n<tr><td>J-Y(ST)Y<\/td><td>3x2x0.8<\/td><td>3<\/td><td>0.8<\/td><td>29.8<\/td><td>1.1<\/td><td>8.0<\/td><td>77<\/td><\/tr>\n\n<tr><td>J-Y(ST)Y<\/td><td>4x2x0.8<\/td><td>4<\/td><td>0.8<\/td><td>39.4<\/td><td>1.1<\/td><td>8.7<\/td><td>94<\/td><\/tr>\n\n<tr><td>J-Y(ST)Y<\/td><td>5x2x0.8<\/td><td>5<\/td><td>0.8<\/td><td>49.9<\/td><td>1.1<\/td><td>9.4<\/td><td>114<\/td><\/tr>\n\n<tr><td>J-Y(ST)Y<\/td><td>6x2x0.8<\/td><td>6<\/td><td>0.8<\/td><td>59.5<\/td><td>1.1<\/td><td>10.1<\/td><td>135<\/td><\/tr>\n\n<tr><td>J-Y(ST)Y<\/td><td>10x2x0.8<\/td><td>10<\/td><td>0.8<\/td><td>98.9<\/td><td>1.3<\/td><td>13.1<\/td><td>205<\/td><\/tr>\n\n<tr><td>J-Y(ST)Y<\/td><td>12x2x0.8<\/td><td>12<\/td><td>0.8<\/td><td>118.1<\/td><td>1.3<\/td><td>13.5<\/td><td>235<\/td><\/tr>\n\n<tr><td>J-Y(ST)Y<\/td><td>16x2x0.8<\/td><td>16<\/td><td>0.8<\/td><td>157.4<\/td><td>1.3<\/td><td>14.8<\/td><td>299<\/td><\/tr>\n\n<tr><td>J-Y(ST)Y<\/td><td>20x2x0.8<\/td><td>20<\/td><td>0.8<\/td><td>194.9<\/td><td>1.3<\/td><td>15.6<\/td><td>352<\/td><\/tr>\n\n<tr><td>J-Y(ST)Y<\/td><td>30x2x0.8<\/td><td>30<\/td><td>0.8<\/td><td>291.8<\/td><td>1.5<\/td><td>19.4<\/td><td>522<\/td><\/tr>\n\n<tr><td>J-Y(ST)Y<\/td><td>40x2x0.8<\/td><td>40<\/td><td>0.8<\/td><td>387.8<\/td><td>1.5<\/td><td>20.9<\/td><td>663<\/td><\/tr>\n\n<tr><td>J-Y(ST)Y<\/td><td>50x2x0.8<\/td><td>50<\/td><td>0.8<\/td><td>484.8<\/td><td>1.7<\/td><td>23.7<\/td><td>832<\/td><\/tr>\n\n<tr><td>J-Y(ST)Y<\/td><td>60x2x0.8<\/td><td>60<\/td><td>0.8<\/td><td>581.8<\/td><td>1.7<\/td><td>25.8<\/td><td>978<\/td><\/tr>\n\n<\/tbody>\n\n<\/table>\n\n<\/div>\n\n<p class=\"description\">\nCable configuration is expressed as number of pairs x two conductors x nominal conductor diameter in millimetres. All 28 configurations are reproduced from the reference technical documentation.\n<\/p>\n\n<h3>Conductor Characteristics<\/h3>\n\n<div class=\"table-wrap\">\n\n<table>\n\n<thead>\n<tr>\n<th>Parameter<\/th>\n<th>0.6 mm Conductor<\/th>\n<th>0.8 mm Conductor<\/th>\n<\/tr>\n<\/thead>\n\n<tbody>\n\n<tr>\n<td>Materijal vodi\u010da<\/td>\n<td>Bare Copper<\/td>\n<td>Bare Copper<\/td>\n<\/tr>\n\n<tr>\n<td>Conductor Class<\/td>\n<td>Class 1<\/td>\n<td>Class 1<\/td>\n<\/tr>\n\n<tr>\n<td>Nominal Conductor Diameter<\/td>\n<td>0.6 mm<\/td>\n<td>0.8 mm<\/td>\n<\/tr>\n\n<tr>\n<td>Calculated Geometric Cross-Section<\/td>\n<td>0.283 mm\u00b2<\/td>\n<td>0.503 mm\u00b2<\/td>\n<\/tr>\n\n<tr>\n<td>Conductor Loop Resistance<\/td>\n<td>130.0 \u03a9\/km<\/td>\n<td>73.2 \u03a9\/km<\/td>\n<\/tr>\n\n<tr>\n<td>Reference Pair Range<\/td>\n<td>1\u2013100 Pairs<\/td>\n<td>1\u201360 Pairs<\/td>\n<\/tr>\n\n<tr>\n<td>Approximate Outer Diameter Range<\/td>\n<td>4.5\u201322.1 mm<\/td>\n<td>5.5\u201325.8 mm<\/td>\n<\/tr>\n\n<tr>\n<td>Copper Content Range<\/td>\n<td>6.7\u2013545.3 kg\/km<\/td>\n<td>10.6\u2013581.8 kg\/km<\/td>\n<\/tr>\n\n<tr>\n<td>Approximate Cable Weight Range<\/td>\n<td>26\u2013829 kg\/km<\/td>\n<td>38\u2013978 kg\/km<\/td>\n<\/tr>\n\n<\/tbody>\n\n<\/table>\n\n<\/div>\n\n<p class=\"description\">\nGeometric conductor cross-sections are calculated from the nominal conductor diameters using the circular area formula. They are provided for reference only and do not replace the original diameter-based cable designation.\n<\/p>\n\n<h3>Electrical Characteristics<\/h3>\n\n<div class=\"table-wrap\">\n\n<table>\n\n<thead>\n<tr>\n<th>Parameter<\/th>\n<th>Reference Value<\/th>\n<th>Condition<\/th>\n<\/tr>\n<\/thead>\n\n<tbody>\n\n<tr>\n<td>Peak Operating Voltage<\/td>\n<td>300 V<\/td>\n<td>Telecommunication Applications<\/td>\n<\/tr>\n\n<tr>\n<td>Test Voltage \u2013 Core\/Core<\/td>\n<td>800 V AC<\/td>\n<td>50 Hz<\/td>\n<\/tr>\n\n<tr>\n<td>Test Voltage \u2013 Core\/Screen<\/td>\n<td>800 V AC<\/td>\n<td>50 Hz<\/td>\n<\/tr>\n\n<tr>\n<td>Conductor Loop Resistance<\/td>\n<td>130.0 \u03a9\/km<\/td>\n<td>0.6 mm Conductor<\/td>\n<\/tr>\n\n<tr>\n<td>Conductor Loop Resistance<\/td>\n<td>73.2 \u03a9\/km<\/td>\n<td>0.8 mm Conductor<\/td>\n<\/tr>\n\n<tr>\n<td>Minimum Insulation Resistance<\/td>\n<td>100 M\u03a9\/km<\/td>\n<td>Unit as Stated in Reference<\/td>\n<\/tr>\n\n<tr>\n<td>Maximum Operating Capacitance<\/td>\n<td>10 nF\/km<\/td>\n<td>To Be Confirmed<\/td>\n<\/tr>\n\n<tr>\n<td>Maximum Capacitance Unbalance<\/td>\n<td>300 pF<\/td>\n<td>Per 100 m<\/td>\n<\/tr>\n\n<\/tbody>\n\n<\/table>\n\n<\/div>\n\n<h3>Mechanical &amp; Installation Characteristics<\/h3>\n\n<div class=\"table-wrap\">\n\n<table>\n\n<thead>\n<tr>\n<th>Parameter<\/th>\n<th>Reference Value<\/th>\n<\/tr>\n<\/thead>\n\n<tbody>\n\n<tr>\n<td>Minimum Bending Radius<\/td>\n<td>15 x Cable Outer Diameter<\/td>\n<\/tr>\n\n<tr>\n<td>Installation Environment<\/td>\n<td>Indoor<\/td>\n<\/tr>\n\n<tr>\n<td>Installation Type<\/td>\n<td>Fixed Installation<\/td>\n<\/tr>\n\n<tr>\n<td>Conductor Construction<\/td>\n<td>Solid Copper, Class 1<\/td>\n<\/tr>\n\n<tr>\n<td>Izolacijski materijal<\/td>\n<td>PVC<\/td>\n<\/tr>\n\n<tr>\n<td>Insulation Thickness Range<\/td>\n<td>1.1\u20131.7 mm (as labelled in reference)<\/td>\n<\/tr>\n\n<tr>\n<td>Screen Construction<\/td>\n<td>Plastic-Coated Aluminium Foil with Drain Wire<\/td>\n<\/tr>\n\n<tr>\n<td>Outer Sheath Material<\/td>\n<td>PVC<\/td>\n<\/tr>\n\n<tr>\n<td>Outer Sheath Colour<\/td>\n<td>Grey<\/td>\n<\/tr>\n\n<tr>\n<td>Approximate Outer Diameter Range<\/td>\n<td>4.5\u201325.8 mm<\/td>\n<\/tr>\n\n<tr>\n<td>Approximate Cable Weight Range<\/td>\n<td>26\u2013978 kg\/km<\/td>\n<\/tr>\n\n<\/tbody>\n\n<\/table>\n\n<\/div>\n\n<h3>Temperature Characteristics<\/h3>\n\n<div class=\"table-wrap\">\n\n<table>\n\n<thead>\n<tr>\n<th>Condition<\/th>\n<th>Minimum Temperature<\/th>\n<th>Maximum Temperature<\/th>\n<\/tr>\n<\/thead>\n\n<tbody>\n\n<tr>\n<td>During Bending<\/td>\n<td>-5\u00b0C<\/td>\n<td>+50\u00b0C<\/td>\n<\/tr>\n\n<tr>\n<td>Fixed Installation<\/td>\n<td>-30\u00b0C<\/td>\n<td>+70\u00b0C<\/td>\n<\/tr>\n\n<\/tbody>\n\n<\/table>\n\n<\/div>\n\n<h3>Minimum Bending Radius \u2013 Calculated Values<\/h3>\n\n<div class=\"table-wrap\">\n\n<table>\n\n<thead>\n<tr>\n<th>Configuration<\/th>\n<th>Approx. Outer Diameter (mm)<\/th>\n<th>Minimum Bending Radius \u2013 15 x D (mm)<\/th>\n<\/tr>\n<\/thead>\n\n<tbody>\n\n<tr class=\"group-row\">\n<td colspan=\"3\">Conductor Diameter 0.6 mm<\/td>\n<\/tr>\n\n<tr><td>1x2x0.6<\/td><td>4.5<\/td><td>67.5<\/td><\/tr>\n<tr><td>2x2x0.6<\/td><td>4.9<\/td><td>73.5<\/td><\/tr>\n<tr><td>3x2x0.6<\/td><td>6.2<\/td><td>93.0<\/td><\/tr>\n<tr><td>4x2x0.6<\/td><td>6.6<\/td><td>99.0<\/td><\/tr>\n<tr><td>5x2x0.6<\/td><td>7.1<\/td><td>106.5<\/td><\/tr>\n<tr><td>6x2x0.6<\/td><td>7.6<\/td><td>114.0<\/td><\/tr>\n<tr><td>10x2x0.6<\/td><td>9.3<\/td><td>139.5<\/td><\/tr>\n<tr><td>12x2x0.6<\/td><td>9.5<\/td><td>142.5<\/td><\/tr>\n<tr><td>20x2x0.6<\/td><td>10.9<\/td><td>163.5<\/td><\/tr>\n<tr><td>30x2x0.6<\/td><td>13.7<\/td><td>205.5<\/td><\/tr>\n<tr><td>40x2x0.6<\/td><td>14.5<\/td><td>217.5<\/td><\/tr>\n<tr><td>50x2x0.6<\/td><td>16.5<\/td><td>247.5<\/td><\/tr>\n<tr><td>60x2x0.6<\/td><td>17.5<\/td><td>262.5<\/td><\/tr>\n<tr><td>100x2x0.6<\/td><td>22.1<\/td><td>331.5<\/td><\/tr>\n\n<tr class=\"group-row\">\n<td colspan=\"3\">Conductor Diameter 0.8 mm<\/td>\n<\/tr>\n\n<tr><td>1x2x0.8<\/td><td>5.5<\/td><td>82.5<\/td><\/tr>\n<tr><td>2x2x0.8<\/td><td>6.1<\/td><td>91.5<\/td><\/tr>\n<tr><td>3x2x0.8<\/td><td>8.0<\/td><td>120.0<\/td><\/tr>\n<tr><td>4x2x0.8<\/td><td>8.7<\/td><td>130.5<\/td><\/tr>\n<tr><td>5x2x0.8<\/td><td>9.4<\/td><td>141.0<\/td><\/tr>\n<tr><td>6x2x0.8<\/td><td>10.1<\/td><td>151.5<\/td><\/tr>\n<tr><td>10x2x0.8<\/td><td>13.1<\/td><td>196.5<\/td><\/tr>\n<tr><td>12x2x0.8<\/td><td>13.5<\/td><td>202.5<\/td><\/tr>\n<tr><td>16x2x0.8<\/td><td>14.8<\/td><td>222.0<\/td><\/tr>\n<tr><td>20x2x0.8<\/td><td>15.6<\/td><td>234.0<\/td><\/tr>\n<tr><td>30x2x0.8<\/td><td>19.4<\/td><td>291.0<\/td><\/tr>\n<tr><td>40x2x0.8<\/td><td>20.9<\/td><td>313.5<\/td><\/tr>\n<tr><td>50x2x0.8<\/td><td>23.7<\/td><td>355.5<\/td><\/tr>\n<tr><td>60x2x0.8<\/td><td>25.8<\/td><td>387.0<\/td><\/tr>\n\n<\/tbody>\n\n<\/table>\n\n<\/div>\n\n<p class=\"description\">\nMinimum bending radii are calculated using the approximate outer diameters and the specified factor of 15 x D. Actual installation requirements must be based on the supplied cable dimensions.\n<\/p>\n\n<h3>Applicable Technical Standards<\/h3>\n\n<div class=\"table-wrap\">\n\n<table>\n\n<thead>\n<tr>\n<th>Standard<\/th>\n<th>Reference Application<\/th>\n<\/tr>\n<\/thead>\n\n<tbody>\n\n<tr>\n<td>DIN VDE 0815<\/td>\n<td>Core Identification<\/td>\n<\/tr>\n\n<tr>\n<td>DIN EN 60228<\/td>\n<td>Class 1 Conductor Construction<\/td>\n<\/tr>\n\n<tr>\n<td>EN 60332-1-2<\/td>\n<td>Vertical Flame Propagation Test for a Single Insulated Wire or Cable<\/td>\n<\/tr>\n\n<tr>\n<td>EN 60332-2-2<\/td>\n<td>Vertical Flame Propagation Test for Small Insulated Wires or Cables<\/td>\n<\/tr>\n\n<\/tbody>\n\n<\/table>\n\n<\/div>\n\n<div class=\"notice\">\n\n<strong>Technical Note:<\/strong>\n\nAll cable dimensions, copper contents and cable weights are indicative. Conductor diameters are expressed in millimetres and must not be confused with conductor cross-sectional areas in mm\u00b2. Cable weights are expressed in kg\/km. Drum and packaging weights are not specified in the reference documentation. Reference configurations do not constitute a declaration of current stock availability.\n\n<\/div>\n\n<div class=\"notice\">\n\n<strong>Data Verification:<\/strong>\n\nThe maximum operating capacitance of 10 nF\/km, minimum insulation resistance of 100 M\u03a9\/km and insulation thickness values of 1.1\u20131.7 mm are reproduced as stated in the reference documentation. These parameters and their units require confirmation before technical approval. The 300 V peak operating voltage is not a rated power cable voltage. CPR classification is not specified. All technical specifications, applicable standards and delivery conditions must be confirmed for the supplied product.\n\n<\/div>\n\n<\/div>","protected":false},"excerpt":{"rendered":"<p>UNIMA CABLE | DATA &amp; COMMUNICATION CABLES J-Y(ST)Y \u2013 Shielded Telecommunication Installation Cable Shielded indoor telecommunication installation cable with solid bare copper conductors, PVC core insulation, aluminium foil static screen with drain wire and a grey PVC outer sheath. Designed for fixed indoor telecommunication installations. 300 V Peak Solid Copper Class 1 0.6 \/ 0.8 [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":5714,"parent":0,"menu_order":0,"template":"","property_type":[199],"property_status":[],"property_feature":[],"property_label":[66,81,98],"property_country":[],"property_state":[],"property_city":[],"property_area":[],"class_list":["post-5713","property","type-property","status-publish","has-post-thumbnail","hentry","property_type-data-communication-cables","property_label-commercial-building","property_label-industrial-facilities","property_label-waterfront"],"acf":[],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 4.9.9 - aioseo.com -->\n\t<meta name=\"description\" content=\"J-Y(ST)Y shielded telecommunication cable with solid copper conductors, PVC insulation and aluminium foil screen for fixed indoor installations.\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<meta name=\"author\" content=\"admin\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/unima-cable.com\/hr\/property\/j-ysty\/\" \/>\n\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 4.9.9\" \/>\n\t\t<meta property=\"og:locale\" content=\"hr_HR\" \/>\n\t\t<meta property=\"og:site_name\" content=\"Unima cable - Cable distribution\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"J-Y(ST)Y Shielded Telecommunication Cable | UNIMA CABLE\" \/>\n\t\t<meta property=\"og:description\" content=\"J-Y(ST)Y shielded telecommunication cable with solid copper conductors, PVC insulation and aluminium foil screen for fixed indoor installations.\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/unima-cable.com\/hr\/property\/j-ysty\/\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2026-11-25T10:49:04+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2026-11-25T10:49:05+00:00\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:title\" content=\"J-Y(ST)Y Shielded Telecommunication Cable | UNIMA CABLE\" \/>\n\t\t<meta name=\"twitter:description\" content=\"J-Y(ST)Y shielded telecommunication cable with solid copper conductors, PVC insulation and aluminium foil screen for fixed indoor installations.\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property\\\/j-ysty\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr#listItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/unima-cable.com\\\/hr\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property\\\/#listItem\",\"name\":\"Nekretnine\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property\\\/#listItem\",\"position\":2,\"name\":\"Nekretnine\",\"item\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property-type\\\/data-communication-cables\\\/#listItem\",\"name\":\"Data &amp; Communication Cables\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr#listItem\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property-type\\\/data-communication-cables\\\/#listItem\",\"position\":3,\"name\":\"Data &amp; Communication Cables\",\"item\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property-type\\\/data-communication-cables\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property\\\/j-ysty\\\/#listItem\",\"name\":\"J-Y(ST)Y\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property\\\/#listItem\",\"name\":\"Nekretnine\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property\\\/j-ysty\\\/#listItem\",\"position\":4,\"name\":\"J-Y(ST)Y\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property-type\\\/data-communication-cables\\\/#listItem\",\"name\":\"Data &amp; Communication Cables\"}}]},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/#organization\",\"name\":\"Unima cable\",\"description\":\"Cable distribution\",\"url\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/author\\\/admin\\\/#author\",\"url\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/author\\\/admin\\\/\",\"name\":\"admin\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property\\\/j-ysty\\\/#authorImage\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/c5cd64316e8c316b90636704903a98dab06fc1cbc5559bb333833e1a7005aae2?s=96&d=mm&r=g\",\"width\":96,\"height\":96,\"caption\":\"admin\"}},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property\\\/j-ysty\\\/#webpage\",\"url\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property\\\/j-ysty\\\/\",\"name\":\"J-Y(ST)Y Shielded Telecommunication Cable | UNIMA CABLE\",\"description\":\"J-Y(ST)Y shielded telecommunication cable with solid copper conductors, PVC insulation and aluminium foil screen for fixed indoor installations.\",\"inLanguage\":\"hr\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property\\\/j-ysty\\\/#breadcrumblist\"},\"author\":{\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/author\\\/admin\\\/#author\"},\"creator\":{\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/author\\\/admin\\\/#author\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/unima-cable.com\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/Detaljni-presjek-visebojnog-kabela.png\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property\\\/j-ysty\\\/#mainImage\",\"width\":1536,\"height\":1024},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/property\\\/j-ysty\\\/#mainImage\"},\"datePublished\":\"2026-11-25T10:49:04+00:00\",\"dateModified\":\"2026-11-25T10:49:05+00:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/#website\",\"url\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/\",\"name\":\"Unima cable\",\"description\":\"Cable distribution\",\"inLanguage\":\"hr\",\"publisher\":{\"@id\":\"https:\\\/\\\/unima-cable.com\\\/hr\\\/#organization\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"J-Y(ST)Y Shielded Telecommunication Cable | UNIMA CABLE","description":"J-Y(ST)Y shielded telecommunication cable with solid copper conductors, PVC insulation and aluminium foil screen for fixed indoor installations.","canonical_url":"https:\/\/unima-cable.com\/hr\/property\/j-ysty\/","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"BreadcrumbList","@id":"https:\/\/unima-cable.com\/hr\/property\/j-ysty\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/unima-cable.com\/hr#listItem","position":1,"name":"Home","item":"https:\/\/unima-cable.com\/hr","nextItem":{"@type":"ListItem","@id":"https:\/\/unima-cable.com\/hr\/property\/#listItem","name":"Nekretnine"}},{"@type":"ListItem","@id":"https:\/\/unima-cable.com\/hr\/property\/#listItem","position":2,"name":"Nekretnine","item":"https:\/\/unima-cable.com\/hr\/property\/","nextItem":{"@type":"ListItem","@id":"https:\/\/unima-cable.com\/hr\/property-type\/data-communication-cables\/#listItem","name":"Data &amp; Communication Cables"},"previousItem":{"@type":"ListItem","@id":"https:\/\/unima-cable.com\/hr#listItem","name":"Home"}},{"@type":"ListItem","@id":"https:\/\/unima-cable.com\/hr\/property-type\/data-communication-cables\/#listItem","position":3,"name":"Data &amp; Communication Cables","item":"https:\/\/unima-cable.com\/hr\/property-type\/data-communication-cables\/","nextItem":{"@type":"ListItem","@id":"https:\/\/unima-cable.com\/hr\/property\/j-ysty\/#listItem","name":"J-Y(ST)Y"},"previousItem":{"@type":"ListItem","@id":"https:\/\/unima-cable.com\/hr\/property\/#listItem","name":"Nekretnine"}},{"@type":"ListItem","@id":"https:\/\/unima-cable.com\/hr\/property\/j-ysty\/#listItem","position":4,"name":"J-Y(ST)Y","previousItem":{"@type":"ListItem","@id":"https:\/\/unima-cable.com\/hr\/property-type\/data-communication-cables\/#listItem","name":"Data &amp; Communication Cables"}}]},{"@type":"Organization","@id":"https:\/\/unima-cable.com\/hr\/#organization","name":"Unima cable","description":"Cable distribution","url":"https:\/\/unima-cable.com\/hr\/"},{"@type":"Person","@id":"https:\/\/unima-cable.com\/hr\/author\/admin\/#author","url":"https:\/\/unima-cable.com\/hr\/author\/admin\/","name":"admin","image":{"@type":"ImageObject","@id":"https:\/\/unima-cable.com\/hr\/property\/j-ysty\/#authorImage","url":"https:\/\/secure.gravatar.com\/avatar\/c5cd64316e8c316b90636704903a98dab06fc1cbc5559bb333833e1a7005aae2?s=96&d=mm&r=g","width":96,"height":96,"caption":"admin"}},{"@type":"WebPage","@id":"https:\/\/unima-cable.com\/hr\/property\/j-ysty\/#webpage","url":"https:\/\/unima-cable.com\/hr\/property\/j-ysty\/","name":"J-Y(ST)Y Shielded Telecommunication Cable | UNIMA CABLE","description":"J-Y(ST)Y shielded telecommunication cable with solid copper conductors, PVC insulation and aluminium foil screen for fixed indoor installations.","inLanguage":"hr","isPartOf":{"@id":"https:\/\/unima-cable.com\/hr\/#website"},"breadcrumb":{"@id":"https:\/\/unima-cable.com\/hr\/property\/j-ysty\/#breadcrumblist"},"author":{"@id":"https:\/\/unima-cable.com\/hr\/author\/admin\/#author"},"creator":{"@id":"https:\/\/unima-cable.com\/hr\/author\/admin\/#author"},"image":{"@type":"ImageObject","url":"https:\/\/unima-cable.com\/wp-content\/uploads\/2026\/11\/Detaljni-presjek-visebojnog-kabela.png","@id":"https:\/\/unima-cable.com\/hr\/property\/j-ysty\/#mainImage","width":1536,"height":1024},"primaryImageOfPage":{"@id":"https:\/\/unima-cable.com\/hr\/property\/j-ysty\/#mainImage"},"datePublished":"2026-11-25T10:49:04+00:00","dateModified":"2026-11-25T10:49:05+00:00"},{"@type":"WebSite","@id":"https:\/\/unima-cable.com\/hr\/#website","url":"https:\/\/unima-cable.com\/hr\/","name":"Unima cable","description":"Cable distribution","inLanguage":"hr","publisher":{"@id":"https:\/\/unima-cable.com\/hr\/#organization"}}]},"og:locale":"hr_HR","og:site_name":"Unima cable - Cable distribution","og:type":"article","og:title":"J-Y(ST)Y Shielded Telecommunication Cable | UNIMA CABLE","og:description":"J-Y(ST)Y shielded telecommunication cable with solid copper conductors, PVC insulation and aluminium foil screen for fixed indoor installations.","og:url":"https:\/\/unima-cable.com\/hr\/property\/j-ysty\/","article:published_time":"2026-11-25T10:49:04+00:00","article:modified_time":"2026-11-25T10:49:05+00:00","twitter:card":"summary_large_image","twitter:title":"J-Y(ST)Y Shielded Telecommunication Cable | UNIMA CABLE","twitter:description":"J-Y(ST)Y shielded telecommunication cable with solid copper conductors, PVC insulation and aluminium foil screen for fixed indoor installations."},"aioseo_meta_data":{"post_id":"5713","title":"J-Y(ST)Y Shielded Telecommunication Cable | UNIMA CABLE","description":"J-Y(ST)Y shielded telecommunication cable with solid copper conductors, PVC insulation and aluminium foil screen for fixed indoor installations.","keywords":null,"keyphrases":{"focus":{"keyphrase":"","score":0,"analysis":{"keyphraseInTitle":{"score":0,"maxScore":9,"error":1}}},"additional":[]},"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_custom_url":null,"og_image_custom_fields":null,"og_image_url":null,"og_image_width":null,"og_image_height":null,"og_video":"","og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_image_url":null,"twitter_title":null,"twitter_description":null,"schema_type":"default","schema_type_options":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"WebPage","isEnabled":true},"graphs":[]},"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":"-1","robots_max_videopreview":"-1","robots_max_imagepreview":"large","priority":null,"frequency":"default","local_seo":null,"limit_modified_date":false,"ai":{"faqs":[],"keyPoints":[],"schemas":[],"titles":[],"descriptions":[],"socialPosts":{"email":{"subject":"","preview":"","content":""},"linkedin":[],"twitter":[],"facebook":[],"instagram":[]}},"breadcrumb_settings":null,"seo_analyzer_scan_date":null,"created":"2026-11-25 10:49:05","updated":"2026-11-25 10:59:10"},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/unima-cable.com\/hr\" title=\"Home\">Home<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/unima-cable.com\/hr\/property\/\" title=\"Nekretnine\">Nekretnine<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/unima-cable.com\/hr\/property-type\/data-communication-cables\/\" title=\"Data &amp; Communication Cables\">Data &amp; Communication Cables<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\tJ-Y(ST)Y\n\t\t<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"Home","link":"https:\/\/unima-cable.com\/hr"},{"label":"Nekretnine","link":"https:\/\/unima-cable.com\/hr\/property\/"},{"label":"Data &amp; Communication Cables","link":"https:\/\/unima-cable.com\/hr\/property-type\/data-communication-cables\/"},{"label":"J-Y(ST)Y","link":"https:\/\/unima-cable.com\/hr\/property\/j-ysty\/"}],"property_meta":{"_edit_lock":["1795610088:1"],"_thumbnail_id":["5714"],"_edit_last":["1"],"fave_show_price_placeholder":["0"],"fave_availability":["Stock"],"fave_property_map":["1"],"fave_property_location":["25.68654,-80.431345,15"],"houzez_geolocation_lat":["25.68654"],"houzez_geolocation_long":["-80.431345"],"fave_property_map_street_view":["hide"],"fave_featured":["0"],"houzez_featured_listing_date":[""],"fave_loggedintoview":["0"],"fave_agent_display_option":["author_info"],"fave_prop_homeslider":["no"],"fave_single_top_area":["global"],"fave_single_content_area":["global"],"technical_datasheet":[""],"_technical_datasheet":["field_6a8040c7beb2c"],"dop":[""],"_dop":["field_6a8041aba97aa"],"cpr_certificate":[""],"_cpr_certificate":["field_6a8041ebd3dd6"],"installation_guide":[""],"_installation_guide":["field_6a80420faf22d"],"cable_calculator_data":[""],"_cable_calculator_data":["field_6a816609a8215"],"datasheet_product_subtitle":[""],"_datasheet_product_subtitle":["field_6ab7857caa586"],"datasheet_description":[""],"_datasheet_description":["field_6ab785aaaa587"],"datasheet_construction":[""],"_datasheet_construction":["field_6ab7866c910b7"],"datasheet_standards":[""],"_datasheet_standards":["field_6ab7869f81536"],"datasheet_applications":[""],"_datasheet_applications":["field_6ab786d7788a3"],"datasheet_technical_data":[""],"_datasheet_technical_data":["field_6ab7870017566"],"datasheet_size_data":[""],"_datasheet_size_data":["field_6ab787279d659"],"datasheet_highlights":[""],"_datasheet_highlights":["field_6ad9232e89762"],"datasheet_category":[""],"_datasheet_category":["field_6ad929e8ec019"],"datasheet_technical_notes":[""],"_datasheet_technical_notes":["field_6ad92a005051a"],"datasheet_cpr_class":[""],"_datasheet_cpr_class":["field_6ad92a1bdd6aa"],"_aioseo_title":["J-Y(ST)Y Shielded Telecommunication Cable | UNIMA CABLE"],"_aioseo_description":["J-Y(ST)Y shielded telecommunication cable with solid copper conductors, PVC insulation and aluminium foil screen for fixed indoor installations."],"_aioseo_og_title":[""],"_aioseo_og_description":[""],"_aioseo_og_article_section":[""],"_aioseo_twitter_title":[""],"_aioseo_twitter_description":[""],"_aioseo_keywords":["a:0:{}"],"_aioseo_og_article_tags":["a:0:{}"],"unima_cable_designation":[""],"unima_cable_aliases":[""],"houzez_manual_expire":["0"],"_houzez_expiration_date_status":["saved"],"houzez_total_property_views":["27"],"houzez_views_by_date":["a:5:{s:10:\"11-25-2026\";i:7;s:10:\"11-26-2026\";i:13;s:10:\"11-27-2026\";i:2;s:10:\"11-28-2026\";i:2;s:10:\"11-29-2026\";i:3;}"],"houzez_recently_viewed":["2026-11-29 15:11:37"],"_elementor_page_assets":["a:0:{}"]},"_links":{"self":[{"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/properties\/5713","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/properties"}],"about":[{"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/types\/property"}],"author":[{"embeddable":true,"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/users\/1"}],"version-history":[{"count":1,"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/properties\/5713\/revisions"}],"predecessor-version":[{"id":5715,"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/properties\/5713\/revisions\/5715"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/media\/5714"}],"wp:attachment":[{"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/media?parent=5713"}],"wp:term":[{"taxonomy":"property_type","embeddable":true,"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/property_type?post=5713"},{"taxonomy":"property_status","embeddable":true,"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/property_status?post=5713"},{"taxonomy":"property_feature","embeddable":true,"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/property_feature?post=5713"},{"taxonomy":"property_label","embeddable":true,"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/property_label?post=5713"},{"taxonomy":"property_country","embeddable":true,"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/property_country?post=5713"},{"taxonomy":"property_state","embeddable":true,"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/property_state?post=5713"},{"taxonomy":"property_city","embeddable":true,"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/property_city?post=5713"},{"taxonomy":"property_area","embeddable":true,"href":"https:\/\/unima-cable.com\/hr\/wp-json\/wp\/v2\/property_area?post=5713"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}